Entrelec ML 10/13.SF, ML 10/13.SN Catalog Page

T01082 001229
Fuse holder terminal blocks
for 6,35 x 25,4 mm 1/4 x 1 in. and 6,35 x 32 mm 1/4 x 1 1/4 in. fuses
Compression clamp
DIN 1 - DIN 3
End stop End stop
th. 9,1 mm th. 9,1 mm
Other end stops : See Accessories section
Rail PR30 Rail Rail PR5 Rail
35 x 7,5 x 1 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 32 x 15 PR1Z2 0163 050.04
Other rails : See Accessories section
Notes
The use of some accessories may decrease the block's voltage rating. For more information, consult us.
Accessories
1
2
3
4
5
6-7
8
BADL V0 0199 408.02 BAM 0103 002.26
prepunched
0173 220.05
prepunched
0101 598.26
1 End section black 2 Test plug
3 Test socket
4 Standard jumper bar
screw for BJS washer for BJS
5 Comb-type jumper bar 70 A 6 Assembly rod
7 Assembly ring 8 Fuse 6,35x32 mm (
1/4
1/4
x 1
") BPC quick-blow fuse cartridge as per IEC 127-2
HPC time delay fuse cartridge as per UL 198G
ML 10/13.SF
Spacing 13 mm (.512")Spacing 13 mm (.512")
ML 10/13.SN
13 mm block with disconnect link bar locked on blue lever.
13 mm standard block.
Color Type Part numbers Color Type Part numbers
Black V0
ML 10/13.SF 0199 095.13
Black / Blue V0
ML 10/13.SN 0199 105.22
Characteristics Characteristics
Wire size
NFC DIN
Compression clamp
0,5-16 mm² 22-10 AWG 22-8 AWG
Solid wire
0,5-10 mm² 22-10 AWG 22-8 AWG
Stranded wire
Voltage
Rated Pulse Pollution degree
800 V (1) 600 V (1) 600 V (1)
8 kV
3
Current
Rated
16 A 25 A 25 A
Wire size
Rated / Gauge
Wire stripping Recomm. Recomm. Protection
length screwdriver torque
12 mm 5,5 mm 1,2-1,4 Nm
.472" .217" 10.6-12.3 Ib.in
10 mm² / A6 10 AWG 8 AWG
Type Part numbers FEM13U V0 1,5 mm 0199 635.24
FC2 2 mm 0007 865.26 FC4 4 mm 0167 860.01 AL2 2 mm 0163 043.21 AL3 3 mm 0163 261.00 AL4 4 mm 0163 262.01 BJS131 (2) 10 0175 991.11
th. DIA. DIA. DIA. DIA. DIA.
poles
VJS11 0163 394.26 RDJ11 0168 783.01 PC13 10 0173 510.20 TGA13 2 0168 564.05 TGA13 3 0168 565.06 TGA13 4 0168 566.07
poles poles poles poles
ANT 0168 675.14 FU633 6,35 x 32
0,25 A 0168 554.03 0,63 A 0168 555.04
1A 0168 556.05 1,6 A 0168 557.06 2,5 A 0168 558.17
4A 0168 559.10
6,3 A 0168 560.15
10 A 0168 561.02
16 A 0168 562.03
Wire size
IEC UL CSA
NFC DIN
Compression clamp
0,5-16 mm² 22-10 AWG 22-8 AWG
Solid wire
0,5-10 mm² 22-10 AWG 22-8 AWG
Stranded wire
Voltage
Rated Pulse Pollution degree
800 V 600 V 600 V
8 kV
3
Current
Rated
16 A 25 A 25 A
Wire size
Rated / Gauge
Wire stripping Recomm. Recomm. Protection
length screwdriver torque
12 mm 5,5 mm 1,2-1,4 Nm
.472" .217" 10.6-12.3 Ib.in
10 mm² / A6 10 AWG 8 AWG
Type Part numbers FEM13U V0 1,5 mm 0199 635.24
FC2 2 mm 0007 865.26 FC4 4 mm 0167 860.01 AL2 2 mm 0163 043.21 AL3 3 mm 0163 261.00 AL4 4 mm 0163 262.01 BJS131 (2) 10 0175 991.11
th. DIA. DIA. DIA. DIA. DIA.
poles
VJS11 0163 394.26 RDJ11 0168 783.01 PC13 10 0173 510.20 TGA13 2 0168 564.05 TGA13 3 0168 565.06 TGA13 4 0168 566.07
poles poles poles poles
ANT 0168 675.14
Installation of jumper bar not assembled
R
R See section on markers
marking method
6 17 26
RC610 on top of block RC810 on sides of bock
6 17 26
RC610 on top of block RC810 on sides of block
Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating.
(2) Use of these accessories require the user to cut out the partition.
145