Entrelec M 4/8.D2 Catalog Page

T01108 001229
Fuse holder terminal blocks
Double-deck
for 5 x 20 and 5 x 25 mm fuses Compression clamp
DIN 1 - DIN 3
With or without blown fuse indicator.
Note: For terminal block with matching profile to fuse block M 4/8.D2.SF, use M 4/8.D2 shown here.
End stop
Other end stops : See Accessories section
Rail PR30 Rail Rail PR5 Rail
Other rails : See Accessories section
th. 9,1 mm
35 x 7,5 x 1 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 32 x 15 PR1Z2 0163 050.04
Notes
The use of some accessories may decrease the block's voltage rating. For more information, consult us.
* Blocks with LED indicator are labeled "+" on the outside of the lever. The indicator can be reversed in the field if required.
Accessories
1
2
4
9
12, 13
3
5
6
7, 8
10
11
R
BAMH 0114 836.00
prepunched
0173 220.05
prepunched
0101 598.26
1 End section grey 2 Test socket
3 Test plug
4 Assembled
jumper bar (without IP 20 protection)
5 Connector plate 6 Comb-type jumper bar 7 Assembly rod
8 Assembly ring 9 Fuse 5 x 20 mm 250 V
Fuse 5 x 25 mm 250 V Fast acting HPC 1500 A
10 Disconnect link bar 11 Shield connector 12 Jumper bar not assembled
13 Screw for BJS
M 4/8.D2.SF...
Spacing 8 mm (.315")
M 4/8.D2.SF with* or without blown fuse indicator. Internal jumpering option. Grey body.
Color Type Part numbers
Grey Blocks with blown fuse indicator : Neon lamp 110-220 V* (5) LED 24 V* (6) LED 48 V* (6)
M 4/8.D2.SFJ 0115 692.11
M 4/8.D2.SFLJ 0115 649.05 M 4/8.D2.SFDJ 0115 650.02 M 4/8.D2.SFDJ1 0115 651.27
Characteristics
Wire size
Compression clamp
Voltage
Rated Pulse Pollution degree
Current
Rated
Wire size
Rated / Gauge
Wire stripping Recommended Recommended Protection
Type Part numbers FEM8D2S 0116 913.07
AL2 (1) 2 mm 0163 043.21 AL3 (1) 3 mm 0163 261.00 AL4 (1) 4 mm 0163 262.01 FC2 (3) 2 mm 0007 865.26 FC4 (4) 4 mm 0167 860.01 BJM8 (1) 41 A 0168 520.05 BJM8 (1) 41 A 0168 521.22 BJM8 (1) 41 A 0168 522.23 BJM8 (1) 41 A 0168 523.24 BJM8 (1) 41 A 0168 974.00 EL6 35 A 0173 627.21 PC81 35 A 10 0173 523.11 TGA8 2 0168 672.11
ANT 0168 675.14 FU520 0,5 A 0008 288.15
FU525 1,6 A 0167 546.22
CN5 0168 804.07 CBD2S 0178 408.14 BJS8 (2) 41 A 20 0174 789.05 EV6 0168 604.16 VJS11 (2) 0163 394.26
Solid wire Stranded wire
length screwdriver torque
9,5 mm 4 mm 0,5-0,8 Nm IP 20
.374" .157" 4.4-7 Ib.in
IEC UL CSA
0,5-4 mm² 24-12 AWG 24-12 AWG 0,5-4 mm² 24-12 AWG 24-12 AWG
500 V (7) 300 V (7) 250 V
6 kV
3
6,3 A 10 A 10 A
4 mm² / A4 12 AWG 12 AWG
DIA. DIA. DIA. DIA. DIA.
poles poles
3 0168 673.12
poles
4 0168 674.13
poles
1A 0008 290.13 2A 0008 291.00
3,15 A 0008 289.16
5A 0008 292.01
2A 0167 547.23
2,5 A 0167 548.04
4A 0167 549.05
6,3 A 0167 550.02
poles
M 4/8.D2
Spacing 8 mm (.315")
Terminal block compatible with fuse block M 4/8.D2.SF
Color Type Part numbers
Grey
All characteristics are equal to the M 4/8.D2.SF
M 4/8.D2 0360 004.05
Characteristics
IEC UL CSA
NFC DIN
Wire stripping Recommended Recommended Protection
length screwdriver torque
Type Part numbers
R See markers section method
Note : (1) These accessories can be used on the lower connection only. (2) These accessories can be used on the upper connection only. Use of these accessories requires the user to cut out the
partition. (3) For block equipped with test socket AL2. (4) For block equipped with test socket AL4. (5) Leakage current with neon lamp: < 0,5 mA (110 VAC), < 0,7 mA (230 VAC). (6) Leakage current with LED 24 or 48 VDC : < 4,5 mA. (7) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating.
617
RC 610 on lever RC 810 on side
139
Loading...