Transport and storage environmental conditions (not to exceed 15 days)
Ambient temperature range of -40°C to +70°C (-40°F to +159°F)
Relative humidity range of 10% to 95%, non-condensing
Atmospheric pressure range of 50kPa to 106kPa
Operational environmental conditions
The appliance must acclimate to the room temperature in the environment it will be placed—24 hours
is recommended.
The recommended environmental temperature range is 15°C to 32°C (60°F to 90°F).
The recommended relative humidity is above 20%, non-condensing.
Receipt of Appliance
The appliance has been thoroughly tested and
inspected to ensure only the highest quality appliance is
provided. Upon receipt, inspect for any possible shipping
damage and report it at once to the delivering carrier.
See Transportation Damage and Claims section.
This appliance, complete with unattached items and
accessories, may be delivered in one or more packages.
Con rm that all standard items and options have been
received with each appliance as ordered. Save all the
information packed with the appliance.
Indicates that the package contents should
not be used if the package has been
damaged or opened.
Register the appliance online to assure prompt service in
the event of a warranty parts and labor claim.
http://www.enthermics.com/warranty-registration
The serial number is required for all inquiries.
Always include both model and serial number(s) in any
correspondence regarding the appliance.
Date installed: ____________________ Voltage: _____________
Delivery
Transportation Damage and Claims
All Enthermics Medical Systems appliances
are sold Free on Board (F.O.B.) shipping
point, and when accepted by the carrier,
such shipments become the property of the
consignee.
Should damage occur in shipment, do not put the
appliance into service until the damage has been
inspected by an authorized service provider.
Should damage occur in shipment, it is a matter between
the carrier and the consignee. In such cases, the carrier
is assumed to be responsible for the safe delivery of the
merchandise, unless negligence can be established on the
part of the shipper.
1. Conduct an immediate inspection while the appliance
is still in the truck or immediately a er it is moved
to the receiving area. Do not wait until a er the
appliance is moved to a storage area.
2. Do not sign a delivery receipt or a freight bill until
a proper count has been made and inspection of all
appliances are received.
3. Note all damage to packages directly on the carrier’s
4. Have the driver sign the delivery receipt. If the
driverrefuses to sign, make a notation of this refusal
on the receipt.
5. If the driver refuses to allow inspection, write the
following on the delivery receipt: Driver refuses to
allow inspection of containers for visible damage.
6. Contact the carrier’s of ce immediately upon nding
damage and request an inspection. Mail a written
con rmation to the carrier’s of ce with the time,
date, and the person called.
7. Save any packages and packing material for further
inspection by the carrier.
8. Promptly le a written claim with the carrier and
attach copies of all supporting paperwork.
Enthermics will continue our policy of assisting our
customers in collecting claims which have been properly
led and actively pursued. Enthermics cannot, however,
le any damage claims, assume the responsibility of any
claims, or accept deductions in payment for such claims.
To prevent injury or property damage:
Always apply both caster brakes on mobile carts,
appliances, or accessories when stationary.
Appliances on casters can move or roll on uneven floors.
Dimensions
Weight**
**Domestic ground shipping information. Contact the manufacturer for export weight and dimensions.
1. Carefully remove the appliance from the carton or crate.
NOTE: Do not discard the carton and other packaging material
until the appliance has been inspected for hidden damage
and tested for proper operation.
Do not discard this manual. This manual is considered to
be part of the appliance and is to be provided to the owner
or manager of the business or to the person responsible for
training operators. Additional manuals are available from
the service department.
2. Read all instructions in this manual carefully before initiating the
installation of this appliance, using the appliance or performing routine
maintenance. Following procedures other than those indicated in this
manual to use and clean the appliance is considered inappropriate and
may cause damage, injury or fatal accidents, in addition to invalidating
the warranty and relieving the manufacturer of all liability.
3. Remove all protective plastic lm, packaging materials, and accessories
from the appliance before connecting electrical power. Store any
accessories in a convenient place for future use.
(HxWxD)
EC1540:72.7" x 23.9" x 33.0" (1846mm x 607mm x 838mm)
EC2060:70.9" x 31.9" x 32.8" (1801mm x 811mm x 833mm)
EC2060 with passthrough
EC1540:Net: 344 lbs (156 kg)Ship: 400 lbs (181 kg)
EC2060:Net: 347 lbs (157 kg)Ship: 404 lbs (183 kg)
(optional):
73.4" x 31.9" x 29.1" (1864mm x 811mm x 739mm)
Shipping dimensions:37" L x 29" W x 79" H
Shipping dimensions:39" L x 35" W x 79" H
Attention:
Due to the size and weight of
the warming cabinet, additional
moving equipment (fork li,
dolly, etc.) will be needed to li
and move the warming cabinet
and packaging materials. Make
appropriate plans when moving
the warming cabinet.
The door may swing during transport. Only
transport the appliance when the door is
closed and secure.
Appliance and accessories may be
heavy. To prevent serious injury, always
4
use a su icient number of trained and
experienced workers when moving or
leveling appliance and handling accessories.
• This blanket warmer is intended for warming dry, cotton
Knowledge of proper procedures is essential to the
blankets or towels only. The blanket warmer is designed
to elevate blanket temperatures to a level which will
increase patient comfort. Any other use for this appliance
is not authorized or recommended.
• The blanket warmer is intended for use in commercial
establishments where all operators are familiar with
the purpose, limitations, and associated hazards of this
appliance. The blanket warmer can be used wherever
there is appropriate space and electrical source including
patient support areas, ER, ICU, PACU, surgical suites,
patient rooms, and nursing stations. Do not use the
blanket warmer in the presence of ammable anesthetic
mixtures (with air, oxygen, or nitrous oxide).
• Operating instructions and warnings must be read and
understood by all operators and users.
• Any troubleshooting guides, component views, and
partslists included in this manual are for general
reference only and are intended for use by quali ed and
trained technicians.
• This manual should be considered a permanent part of
this appliance. This manual and all supplied instructions,
diagrams, schematics, parts lists, notices, and labels must
remain with the appliance if the item is sold or moved to
another location.
safe operation of electrically and/or gas energized
equipment. The following signal words and symbols
may be used throughout this manual.
DANGER
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, could
result in minor or moderate injury.
NOTICE: Indicates information considered important,
but not hazard-related (e.g., messages relating
to property damage).
Indicates that referral to operating
instructions is a mandatory action. If
not followed the operator could su er
personalinjury.
Indicates that referral to operating
instructions is recommended to understand
operation of equipment.
NOTICE: For equipment delivered for use in any
location regulated by the following directive:
2012/95/EC WEEE
The design and operational characteristics of the chamber
eliminate the need for a heat circulating fan.
The controller has an adjustable temperature range of
37°C to 93°C (98°F to 200°F).
The timer feature allows the user to program the controller
to automatically switch on and switch off once during a
24-hour period at selected times. This enables the chamber to
be turned off automatically at night to save energy, but turned
on again in the early morning to ensure warm blankets are
available.
The appliance is equipped with one (1) epoxy-coated
blanket support assembly and one (1) center shelf per
door opening. The appliance is furnished with one (1) set
of 5" (127mm) heavy-duty casters – two (2) rigid and two (2)
swivel with locking brake.
The appliance is equipped with one (1) epoxy-coated
blanket support assembly and one (1) center shelf per
chamber. The appliance is furnished with one (1) set of
5" (127mm) heavy-duty casters – two (2) rigid and two (2)
swivel with locking brake.
This blanket warmer is designed to elevate blanket
temperatures to a level which will increase patient comfort.
The appliance is constructed with stainless steel exterior
casing and door with handle and hinges designed to
withstand heavy usage. A door with window allows
observation of inventory with the door closed. The appliance
is warmed using a low-heat-density electrothermal cable
array. The electrothermal cable is positioned in the oor and
two sides of the warming appliance, providing even heating
of the interior chamber.
The temperature of each chamber is regulated by an
electronic controller consisting of an LED display, ON/OFF
button, increase and decrease buttons, integrated controller
lock-out feature, timer, and a series of prompt sequence
indicators. The design and operational characteristics of the
appliance eliminate the need for a heat circulating fan.
The controller can be set to operate in Fahrenheit or
Celsius. A er a power failure, the appliance remembers its
programming and begins to operate as before. The on/off
indicator ashes to indicate that a failure occurred; pressing
the ON/OFF button once eliminates the ashing. A thermal
shut-off system, separate from the controller, is included as
an additional safety feature.
The controller displays the temperature in whole degrees.
To prevent serious personal injury, death, or
property damage:
Do not steam clean, hose down or flood the
interior or exterior with water or liquid solution
of any kind. Do not use water jet toclean. Failure
to observe this precaution will void the warranty.
To prevent serious personal injury, death,
or property damage:
Do not use this warming appliance in
the presence of flammable anesthetic
mixtures (with air or with oxygen or
nitrous oxide).
NOTICE: Due to the energy e icient design of the
appliance and tight seal around the door, water
vapor from moist or damp blankets placed in the
appliance may cause condensation to collect on
interior surfaces. To avoid this accumulation, use
dry blankets or towels.
A temporary odor may be noticeable upon initial
start-up of the appliance. Contact manufacturer
if the odor persists a er a day or more of
continuous use.