ENTES MCB-7, MCB-8, MCB-9 User manual [ml]

ÇOK FONKSiYONLU ZAMAN RÖLELERÝ (MCB-7 MCB-8 MCB-9)
MCB-7, MCB-8, MCB-9
Mikroiþlemci tabanlý elektronik zaman röleleridir. 0,1 sn.’den 30 saate kadar hassas olarak ayarlanabilen zaman skalasý, dört farklý çalýþma modu (MCB-9) ince ve dar boyutuyla çok amaçlý kullanýma uygun olarak tasarlanmýþlardýr.
MCB-7
MCB-7
ER MODU
MCB-7, ER fonksiyonunda çalýþan bir
zaman rölesidir.0.1 saniyeden 30 saate kadar ayarlanabilir.
MCB-8
2
t
0
1s
30h
MCB-8
ON
OUT
6
4
8
10
10 s
30s
60s
10m
60m
10h
ER MODU
EM MODU
MCB-8, kullanýcýnýn isteðine göre ER ya
da EM fonksiyonunda çalýþan bir zaman rölesidir. 0.1 saniyeden 30 saate kadar ayarlanabilir.
MCB-9
2
t
ON
0
2
t
OFF
0
10 s
1s
30h
MCB-9
6
4
8
ON
10
OUT
6
4
8
10
30s
60s
10m
60m
10h
ER MODU
EM MODU FLAÞÖR
AÇIK FLAÞÖR
KAPALI FLAÞÖR
MCB-9, kullanýcýnýn isteðine göre ER,
EM, Kapalý Flaþör ya da Açýk Flaþör olarak çalýþabilen bir zaman rölesidir. 0.1 saniyeden 30 saate kadar ayarlanabilir.
6
4
8
2
t
ON
2
t
OFF
0
1s
30h
ON
0
10
OUT
6
4
8
10
10 s
30s
60s
10m
60m
10h
Mod seçimi (Fonksiyon Tablosu)
MCB8
MCB9
1-ER Fonksiyonu
2-EM Fonksiyonu
3-Kapalý Flaþör
4-Açýk Flaþör
U
T off
U
T on
U
U
T off
T on
T on
T off
Þekil-4
ZAMAN TABLOSU
ZAMAN
BÖLGESÝ
MCB-7/8/9
0.1-1 sn.
0.1-10 sn.
0.2-30 sn.
0.3-60 sn. 3 sn.-10 dk.
15 sn.-60 dk.
3 dk.-10 saat 9 dk.-30 saat
AYARLANABÝLÝR ZAMAN ARALIÐI
MCB-7/8/9
1 sn. 10 sn. 30 sn.
60 sn. 10 dk.
60 dk. 10 saat 30 saat
A2952/Rev.5
Sürelerin Ayarlanmasý
ON ve OFF Süresinin Ayarlanmasý
Zaman bölgesi seçim trimpotunu ve t kullanarak þu formül uyarýnca hesaplanýr: a, seçilen zaman bölgesinin sýnýrý; t, istenen zaman; x, trimpotun konumu olmak üzere;
X=
10.t a
ve
t=
ya da ton trimpotunu
off
x
.a
10
Örnek olarak;
ton yada t
10s
1s
30h
10h
5 saate ayarlamak isteniyorsa;
10s
1s
30h
trimpotu 3’ü gösteriyorsa
off
30s
60s
10m
=30s
60m
2
Ýstenen zaman
30s
60s
10m
=10h
60m
10h
zaman bölgesi
üst deðeri
t
rimpotun konumu
6
4
8
0
10
x=
3
t=
10
10.5
t
= 5
10h rimpotun konumu
= 9 s
.30s
zaman bölgesi
üst deðeri
6
4
8
2
0
10
Boyutlar
23
12
(Þekil 5)
35
28
48
58
45
19
(TÝP PK 22)
90
61
19
Baðlantý Þekli
MCB 7-8-9
2
1
3
A1-A2 : 115/127/220/230 VAC
A2
A1
A3-A2 : 12 VAC/DC
24 VAC/DC
A3
Teknik Bilgi
Ýþletme Gerilimi (Un) : 220 VAC, 230 VAC, 240 VAC, 24 VAC/DC Ýþletme Aralýðý : (0.9-1.1) x Un
Ýþletme Frekansý : 50/60 Hz. Çýkýþ Kontaðý : 1 Enversör 8A/2000 VA (NO: 8A, NC: 6A)Cosϕ =1 Tekrarlama Hatasý : +/-%0.1 Reset Süresi : <=150 msn. Ortam Sýcaklýðý : -5°C ; +50°C Boyutlar : Tip PK22 Koruma Sýnýfý : IP 20 Baðlantý Þekli : Klemensli, klemens rayýna montaj, (panoya
Koli Aðýrlýðý : 2.5kg. (Bir kolide 24 adet)
(115,127 V AC ve12 VAC/DC istek üzerine yapýlýr.)
vida ile montaj adaptör parçasý ile mümkündür. Bakýnýz Þekil 5)
Önemli Uyarý:
1) Ýþletme gerilimi 1 sn.den kýsa bir sürede belirtilen deðerlere yükseltilmelidir.
2) Jeneratörle kullanmayýnýz.
Doðru Kullaným ve Güvenlik Þartlarý:
Aþagýdaki þartlara uyulmamasý halinde ölüm ve ciddi yaralanmalar olabilir.
- Cihaz baðlanýrken bütün enerjiyi kesiniz.
- Cihaz þebekeye baðlandýðýnda ön paneli çýkartmayýnýz.
- Cihazý solvent yada benzeri bir madde ile temizlemeye çalýþmayýnýz. Sadece kuru bez kullanýnýz.
- Baðlantýlarý kontrol ediniz.
- Elektriksel cihazlar sadece bayiniz tarafýndan tamir edilmelidir.
- Cihaz sadece pano tipi montaj içindir.
- Kullanýlacak sigorta F tipi olmalý ve akým sýnýr deðeri 1A olmalýdýr.
Yukarýdaki önlemlerin uygulanmamasý sonucu doðabilecek istenmeyen durumlardan üretici firma hiç bir þekilde sorumlu tutulamaz.
MULTI-FUNCTIONAL TIMER (MCB-7 MCB-8 MCB-9)
MCB-7, MCB-8, MCB-9 multifunctional microprocessor based timer
relay. It designed with the fine adjustable scale from 0.1 sec. to 30 h with different programming modes (MCB-9) and with the slim case.
MCB-7
MCB-7
ER MODE
MCB-7, is a time relay that works at ER function
It can be adjusted from 0.1 seconds to 30 hours.
OUT
6
4
8
2
t
0
10
10 s
30s
1s
60s
10m
60m
30h
10h
MCB-8
MCB-8
ER MODE
EM MODE
MCB-8, is a time relay that works at ER or
EM function. It can be adjusted from 0.1 seconds to 30 hours.
MCB-9
2
t
ON
0
2
t
OFF
0
10 s
1s
30h
MCB-9
6
4
8
10
OUT
6
4
8
10
30s
60s
10m
60m
10h
ER MODE
EM MODE FLASHER
ON FLASHER
OFF FLASHER
MCB-9, is a time relay that works as ER,EM,
Off Flasher or On Flasher according to user’s require. It can be adjusted from 0.1 seconds to 30 hours.
6
4
8
2
t
ON
0
10
OUT
6
4
8
2
t
OFF
0
10
10 s
30s
1s
60s
10m
60m
30h
10h
Mode selection (Function Table)
MCB8
MCB9
1-ER Function
2-EM Function
3-On Flasher
4-Off Flasher
U
T off
U
T on
U
U
T off
T on
T on
T off
Figure-4
TIME TABLE
TIME
INTERVAL
MCB-7/8/9
0.1-1 s.
0.1-10 s.
0.2-30 s.
0.3-60 s. 3 s.-10 min.
15 s.-60 min. 3 min.-10 hour 9 min.-30 hour
ADJUSTABLE
TIME VALUE
MCB-7/8/9
1 s. 10 s. 30 s.
60 s. 10 min.
60 min. 10 hour 30 hour
A2951/Rev.3
Time Settings
Adjusting ON and OFF Time
It is calculated by selecting time region knob and using t as the formula: a, limit of time region; t, required time; x, position of knob;
X=
10.t
ve
a
ON
t=
x
10
.a
For example;
if ton or t
10s
1s
30h
10h
if required to adjust 5 hours;
10s
1s
ON
30h
off
30s
60s
10m
60m
30s
60s
10m
60m
10h
knob shows 3;
4
Required time
=10h
maximum value
2
0
time region
=30s
Position of knob
6
8
10
10.5
x=
3
t=
10
= 5
10h
Position of knob
= 9 s
.30s
time region
maximum value
Dimensions
23
19
35
61
45
12
28
ON
(Figure 5)
48
58
(TÝP PK 22)
19
Connection Diagram
MCB 7-8-9
2
A2
1
3
A1
A1-A2 : 115/127/220/230 VAC A3-A2 : 12 VAC/DC
24 VAC/DC
A3
Technical Data
Rated Voltage (Un) : 220 VAC, 230 VAC, 240 VAC, 24 VAC/DC Operating Range
Operating Frequency : 50/60 Hz. Output Contact : 1 Changeover 8A/2000 VA (NO: 8A, NC: 6A)Cosϕ =1 Repetition Error : +/-%0.1 Reset Time : <=150 msec. Ambient Temperature : -5°C ; +50°C Dimensions : Tip PK22 Protection Class : IP 20
Connection : Slimline,Terminal (Panel mount is available
with the plastic adapter part. Package Weight : 2.5 kg. (24 pcs. per package)
(115,127 V AC and 12 VAC/DC available upon request) : (0.9-1.1) x Un
Refer to fig. 5
Caution:
1) Rated voltage must raise to the indicated value in less than 1s.
2) Do not use with generator.
PRECAUTIONS FOR INSTALLATION AND SAFE USE
Failure to follow those instructions will result in death or serious injury.
- Disconnect all power before working on equipment..
- When the device is connected to the network, do not remove the front panel.
- Do not try to clean the device with solvent or the like.Only clean with dry cloth.
- Verify correct terminal connections when wiring.
- Electrical equipment should be serviced only by your component seller.
- Mount device to the panel
No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material.
Vertrieb durch TDE Instruments GmbH
or ton knob
off
2
0
90
6
4
8
10