Enterasys Networks VH-2402-L3 User Manual

VERTICAL HORIZON
VH-2402-L3
FAST ETHERNET SWITCH
USER GUIDE
9033693-01
Notice
9033693-01 ii
Only qualified personnel should perform installation procedures.

NOTICE

Enterasys Networks reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL Enterasys Networks BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN THEM, EVEN IF Enterasys Networks HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Enterasys Networks, Inc. 500 Spaulding Turnpike Portsmouth, NH 03801
2002 Enterasys Networks, Inc. All Rights Reserved Printed in the United States of America
Order Number: 9033693-01 April 2002
LANVIEW is a registered trademark of Enterasys Networks. ENTERASYS NETWORKS, NETSIGHT, MATRIX, WEBVIEW, and any logos associated therewith, are trademarks of Enterasys Networks.
SPECTRUM is a registered trademark of Aprisma Management Technologies, Inc.
All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
iii 9033693-01
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
9033693-01 iv
Notice
VCCI NOTICE
This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
CLASS A ITE NOTICE
WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
The VH-2402-L3 24-port switch uses Class 1 Laser transceivers. Read the following safety information before installing or operating these modules.
Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser transceivers comply with the following safety standards:
21 CFR 1040.10 and 1040.11 U.S. Department of Health and
Human Services (FDA).
IEC Publication 825 (International Electrotechnical Commission).
CENELEC EN 60825 (European Committee for Electrotechnical
Standardization).
9033693-01 v
When operating within their performance limitations, laser
transceiver output meets the Class 1 accessible emission limit of all three standards. Class 1 levels of laser radiation are not considered hazardous.
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
LASER RADIATION AND CONNECTORS
When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10
Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The maximum radiance from the optical port (under worst case conditions) is 0.8 W
–2
or 8 x 10 3 W m 2 sr -1 .
cm
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the switch.
-6
watts.
WARNING: FIBER OPTIC PORT SAFETY
When using a fiber optic port, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.
AVERTISSMENT: PORTS POUR FIBRES OPTIQUES -
SÉCURITÉ SUR LE PLAN OPTIQUE
Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.
9033693-01 vi
Notice
WARNHINWEIS: FASEROPTIKANSCHLÜSSE -
OPTISCHE SICHERHEIT
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.
SAFETY INFORMATION
WICHTIGE SICHERHEITSHINWEISE (GERMANY)
1. Bitte lesen Sie diese Hinweise sorgfältig durch.
2. Heben Sie diese Anleitung für den späteren Gebrauch auf.
3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung.
4. Die Netzanschlu ßsteckdose soll nahe dem Gerät angebracht und leicht zugänglich sein.
5. Das Gerät ist vor Feuchtigkeit zu schützen.
6. Bei der Aufstellung des Gerätes ist auf sicheren Stand zu achten. Ein Kippen oder Fallen könnte Beschädigungen hervorrufen.
7. Die Belüftungsöffnungen dienen der Luftzirkulation, die das Gerät vor Überhitzung schützt. Sorgen Sie dafür, daß diese Öffnungen nicht abgedeckt werden.
8. Beachten Sie beim Anschluß an das Stromnetz die Anschlußwerte.
9. Verlegen Sie die Netzanschlußleitung so, daß niemand darüber fallen kann. Es sollte auch nichts auf der Leitung abgestellt werden.
10. Alle Hinweise und Warnungen, die sich am Gerät befinden, sind zu beachten.
11. Wird das Gerät über einen längeren Zeitraum nicht benutzt, sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer Überspannung eine Beschädigung vermieden.
12. Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerätgelangen. Dies könnte einen Brand bzw. elektrischen Schlag auslösen.
13. Öffnen sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden.
14. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einerqualifizierten Servicestelle zu überprüfen:
a.Netzkabel oder Netzstecker sind beschädigt. b. Flüssigkeit ist in das Gerät eingedrungen. c. Das Gerät war Feuchtigkeit ausgesetzt. d. Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder
Sie mit Hilfe
dieser Anleitung keine Verbesserung erzielen. e. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt. f. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.
15. Zum Netzanschluß dieses Gerätes ist eine geprüfte Leitung zu verwenden. Für einen Nennstrom bis 6A und einem Gerätegewicht größer 3kg ist eine Leitung nicht leichter als H05VV-F, 3G, 0.75mm 2 einzusetzen.
Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70dB(A) oder weniger.
9033693-01 vii
ENTERASYS NETWORKS, INC.
PROGRAM LICENSE AGREEMENT
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
CAREFULLY READ THIS LICENSE AGREEMENT.
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT.
This document is an agreement (“ Agreement” ) between You, the end user, and Enterasys Networks, Inc. (“ Enterasys” ) that sets forth your rights and obligations with respect to the Enterasys software program (“Program” ) in the package. The Program may be contained in firmware, chips or other media. UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, RETURN THE UNOPENED PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS (603) 332-9400. Attn: Legal Department.
1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as permitted by
the Copyright Act of the United States or as authorized in writing by Enterasys.
2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program.
3. APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
4. EXPORT REQUIREMENTS. You understand that Enterasys and its Affiliates are subject to regulation by agencies of the U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain technical products to certain countries, unless a license to export the product is obtained from the U.S. Government or an exception from obtaining such license may be relied upon by the exporting party.
If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes.
9033693-01 viii
Notice
If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export Administration Regulations, in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement, You agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Bulgaria, Cambodia, Cuba, Estonia, Georgia, Iraq, Kazakhstan, Kyrgyzstan, Laos, Lat via, Libya, Lithuania, Moldova, North Korea, the People’s Republic of China, Romania, Russia, Rwanda, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as ma y be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Cont rol List, or (iii) if the direct product of the technology is a complete plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was developed solely at private expense; (ii) contains ‘‘restricted computer software’’ submitted with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Product is considered commercial computer software in accordance with DFARS section 227.7202-3 and its successors, and use, duplication, or disclosure by the Government is subject to restrictions set forth herein.
6. EXCLUSION OF WARRANTY. Except as may be specifically provided by Enterasys in writing, Enterasys makes no warranty, expressed or implied, concerning the Program (including its documentation and media).
ENTERASYS DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY ENTERASYS IN WRITING, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
7. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL
ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THIS ENTERASYS PRODUCT, EVEN IF ENTERASYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU.
9033693-01 ix
DECLARATION OF CONFORMITY
Application of Council Directive(s): 89/336/EEC 73/23/EEC
Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’s Address: 500 Spaulding Turnpike
PO Box 3060 Portsmouth, NH 03801
European Representative Address: Enterasys Networks Ltd. Nexus House, Newbury Business
Park London Road, Newbury Berkshire RG14 2PZ,
England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC
EC Directive 73/23/EEC EN 55022 EN 55024 EN 60950 EN 60825
Equipment Type/Environment: Networking Equipment, for
use in a Commercial
or Light Industrial
Environment.
Enterasys Networks, Inc. declares that the equipment packaged with this notice
conforms to the above directives.
9033693-01 10

Table of Contents

PREFACE ............................................................................. 13
Purpose...................................................................... 13
Audience.................................................................... 13
Conventions.............................................................. 13
Organization................................................................ 15
PRODUCT OVERVIEW...................................................... 16
Description................................................................. 16
Layer 3 Switching..................................................... 16
The Functions of a Layer 3 Switch........................ 18
Features..................................................................... 19
Ports........................................................................... 19
Performance Features............................................. 20
Layer 2 Features...................................................... 20
Layer 3 Switch Features ......................................... 22
Traffic Classification and Prioritization...................... 22
Management................................................................ 23
Optional Redundant Power Supply....................... 24
Fast Ethernet Technology....................................... 24
Gigabit Ethernet Technology...................................... 24
Front Panel.................................................................. 25
Rear Panel.................................................................. 26
Side Panels ................................................................. 26
Optional Plug-in Modules........................................ 27
1000BASE-T Module............................................... 27
1000BASE-SX Fiber Module.................................. 28
GBIC Two-Port Module........................................... 28
LED Indicators.......................................................... 29
Feature Summaries ................................................. 29
Factory Defaults ....................................................... 33
2. INSTALLATION.............................................................. 35
9033693-01 11
Inspecting Your Shipment....................................... 35
Installation ................................................................. 36
Desktop or Shelf Installation................................... 36
Rack Installation....................................................... 37
Power on.................................................................... 38
Power Failure............................................................ 39
3. CONNECTING THE SWITCH ...................................... 40
Switch to End Node .................................................... 40
Switch to Hub or Switch............................................. 41
10BASE-T Device.................................................... 42
100BASE-TX Device ............................................... 42
APPENDIX A. TECHNICAL SPECIFICATIONS............ 43
APPENDIX B. FLOW CONTROL..................................... 46
APPENDIX C. ACRONYMS AND ABBREVIATIONS .. 48
INDEX.................................................................................... 50
9033693-01 12

Preface

Purpose

This guide provides information about the features and applications of the Enterasys Networks Vertical Horizon VH-2402-L3 layer 3 switch.

Audience

This guide is intended for Ethernet Local Area Network (LAN) administrators and Management Information Systems (MIS) personnel with the following background:
Working knowledge of Ethernet LANs
Familiarity with Transmission Control
Protocol/Internet Protocol (TCP/IP) and Simple Network Management Protocol (SNMP)

Conventions

This section describes the conventions used in this guide.
Message Formats
Two types of messages, identified by icons, appear in the text
9033693-01 13
A note informs you of special circumstances.
A caution indicates the possibility of equipment damage
Keyboard Entries
This guide uses the following conventions for keyboard entries:
When you read “enter”, type the text and press the [Enter] key.
Example: Enter the Gateway IP address and press the [Enter] key.
When you read “select”, highlight the menu item and press the [Enter] key.
Other Conventions
This guide uses the following typographical conventions:
Initial Caps Menu titles and console selections.
[Enter] Used to designate the Enter or
Return key.
Courier font Screen messages and user
prompts.
Selection Describes a user-configurable
interface item.
Field Describes a read-only
information item.
9033693-01 14

Organization

Chapter 1. Product Overview: Describes the features of the switch, front and rear panel components and application examples.
Chapter 2. Installation: Describes the content of your switch shipment, lists site requirements, and provides mounting instructions. Instructions for making connections and powering up the switch are provided as well.
Appendix A. Technical Specifications: Provides a list of standards compliance and certifications as well as physical and operational specifications.
Appendix B. Flow Control: Describes how the flow control features are used to provide a mechanism for protecting the switch from overload conditions and to keep additional traffic off the network.
Appendix C. Acronyms and Abbreviations: Provides definitions for a list of common acronyms and abbreviations used within the installation guide and the networking industry.
9033693-01 15

Product Overview

This chapter provides the following information:
Product Description
Features
Front and Rear Panel Component Descriptions
Feature Summaries
Application Example

Description

This installation guide describes Enterasys Networks’ Vertical Horizon VH-2402-L3 Fast Ethernet switch. The switch provides 24 10Base-T/100Base-TX ports, plus one slot for optional slide-in 1000Base-SX 1000Base-T and GBIC modules. The switch features a built in SNMP-based Management agent. The VH-2402-L3 support both Layer 2 as well as Layer 3 functionality.

Layer 3 Switching

Layer 3 switching is an integration of two proven technologies: switching and routing. In fact, Layer 3 switches are running the same routing routines and protocols as traditional routers. The main difference between traditional routing and Layer 3 switching is the addition of a group of Layer 2 switching domains and the execution of routing routines for most packets via an ASIC – in hardware instead of software.
16 9033693-01
Loading...