Enterasys VHIM1000-S1GM Quick Installation Manual

SAFETY WARNING
Before installing or removing the VHIM1000-S1GM, first disconnect the switch from the main power supply. For full safety instructions, please refer to the user guide that accompanies the switch.
Warning:
Optical Safety for Fiber Optic Modules
When using a fiber optic media expansion module, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.
Avertissment:
Ports pour fibres optiques ­sécurité sur le plan optique
Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.
Warnhinweis:
Faseroptikanschlüsse ­Optische Sicherheit
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.
SPECIFICATIONS
Slots
1 slot for GBIC transceivers
Communication Mode
Can support half or full duplex, and auto-negotiation for duplex mode and flow control (depending on the GBIC transceiver)
Network Interface
GBIC connector, hot swappable
Queue Buffer
2 Mbytes
Size
4.82 x 3.57 x 1.08 in. (12.25 x 90.70.5 x 2.74 cm)
Power Consumption
2.4W maximum
Temperature
Operating: 32° to 122° F (0° to 50° C) Storage: -40° to 158° F (-40° to 70° C)
Humidity
Operating: 5% to 95%
Compliances
CE Mark Emissions
FCC Class A EN55022 (CISPR 22) Class A VCCI Class A C-Tick
Immunity
IEC 1000-4-2/3/4/6
Standards
802.3z Gigabit Ethernet ISO/IEC 8802-3
CONNECTIVITY GUIDELINES
snoitacificepSdnasepyTelbaC
elbaCepyThtgneL.xaMrotcennoC
T-esaB01PTUmho-0015,4,3.taC).tf823(m00154-JR
XT-esaB001PTUmho-0015.taC).tf823(m00154-JR
XF-esaB001norcim521/5.26ro521/05
rebifedomitlumeroc
xelpudflaH).tf4.153,1(m214TSroCS
xelpudlluF)selim42.1(mk2TSroCS
rebifedom-elgnis521/01)selim12.6(mk01TSroCS
XS-esaB0001norcim521/5.26ro521/05
rebifedomitlumeroc
gniwollofehteeS
elbat
TSroCS
XL-esaB0001FMSroFMMgniwollofehteeS
elbat
TSroCS
snoitacificepSrebiFXS-esaB0001
retemaiDrebiF htdiwdnaBladoM egnaR
norcim521/5.26
mk/zHM061)m022-2(tf227-7
mk/zHM002)m572-2(tf209-7
norcim521/05
mk/zHM004)m005-2(tf1461-7
mk/zHM005)m055-2(tf5081-7
snoitacificepSrebiFXL-esaB0001
retemaiDrebiF htdiwdnaBladoM egnaR
FMM521/5.26
mk/zHM005)tf5081-7(m055-2
FMM521/05
mk/zHM004)tf5081-7(m055-2
mk/zHM005)tf5081-7(m055-2
FMS521/01A/N)tf404,61-7(mk5-m2
retemaiDkrowteNtenrehtEtsaFmumixaM
epyTretaepeR
rebmuNdna
riaPdetsiwT XT-ESAB001
rebiF/riaPdetsiwT
XFdnaXT-ESAB001
IssalC1)tf656(m002)tf4.558(m8.062
IIssalC1)tf656(m002)tf6.2101(m8.803
IIssalC2)tf4.276(m502)tf1.907(m2.612
Note: Network diameter is defined as the wire distance between two end stations in the same collision domain.
VHIM1000-S1GM
GIGABIT INTERFACE
CONVERTER MODULE (GBIC)
QUICK INSTALLATION GUIDE
9033660
E112000-R01
150583-102
NOTICE
Enterasys Networks reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
2000 by Enterasys Networks, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved Printed in Taiwan, R.O.C.
Order Number: 9033660 November 2000
Enterasys, Enterasys Networks, and Vertical Horizon are trademarks or registered trademarks of Enterasys Networks, Inc.
Microsoft, Windows, Windows 95, Windows 98, Windows NT, and Windows 2000 are either trademarks or registered trademarks of Microsoft Corporation.
Netscape and Netscape Navigator are trademarks of Netscape Communications Corporation.
All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communica­tions. Operation of this equipment in a residential area is likely to cause interfer­ence in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communica­tions du Canada.
VCCI NOTICE
EC CONFORMANCE DECLARATION
European contact: Enterasys Networks Limited
Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England
This information technology product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications:
EN55022(1988)/CISPR-22(1985) Class A
EN50082-1: IEC 1000-4-2, 3, 4, 6 This information technology product complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE Mark accordingly.
Only qualified personnel should perform installation procedures.
VERTICAL HORIZON GIGABIT ETHERNET CONVERTER MODULE (GBIC)
Enterasys Networks VHIM1000-S1GM Gigabit Ethernet Converter Module provides one slot for a fiber-optic GBIC transceiver. Enterasys currently sells the following transceivers:
1000Base-SX (Aglient HFBR5601 or Finisar FTR-8519P)
1000Base-LX (Aglient HFCT5611)
The 1000Base-SX GBIC transceivers provide one short-wavelength (850 nm) Gigabit port that can be used for a high-speed backbone or server connection. This port can be connected to a site up to 550 m (1805 ft) away with multimode fiber cable.
The 1000Base-LX GBIC transceivers provide one long-wavelength (1300 nm) Gigabit port that can be used for a high-speed backbone or server connection. This port can be connected to a site up to 10 km (6.21 miles) away with single-mode fiber cable.
Gigabit Port LEDs
Port LEDs for the module are located on the front panel of the switch. These LEDs provide por t status for at-a-glance network monitoring. The following table details the indicator functions provided by the Ver tical Horizon switch:
sDELeludoMnoisnapxE
sDEL noitidnoC sutatS
kniLnOnodehsilbatseneebsahknildilavA
.tropeht
gnihsalFro,delbasidyllaunamneebsahtroP
oteudmetsysehtybdenoititrap
.srorreevissecxe
sutatSnO.tolssihtnidellatsnisieludomA
ytivitcAgnihsalF.tropehthguorhtgnissapsiciffarT
INSTALLING THE MODULE
CAUTION: This module is designed to be used with
the Vertical Horizon Series products only. Do not try to install this module in any other units.
Be sure to install the VHIM1000-S1GM GBIC module into the appropriate slot on the switch. Refer to the product User Guide for detailed information.
Equipment Checklist
After unpacking the VHIM1000-S1GM module, check the contents of the box to be sure youve received the following items:
One VHIM1000-S1GM module
This document
Handling the Module
CAUTION: The VHIM1000-S1GM module can easily
be damaged by electrostatic discharge.
To prevent electrostatic damage, observe the following guidelines:
Do not remove the module from its packaging until you are ready to install it.
Do not touch any of the modules pins, connectors or components.
Hold the module only by its edges or front panel.
Wear an anti-static wristband connected to a
suitable earth ground whenever handling the module.
Store or transport this module only in appropriate anti-static packaging.
Instructions
CAUTION: The switch must be powered off before
installing or replacing any module.
1. Power off the switch: Disconnect the AC power cord from the switch. If a redundant power unit (RPU) is present, disconnect its DC cable connection to the switch.
2. Remove network cables: If you are replacing a module, remove the cable attached to the port on the module.
3. Loosen the screws on the installed module or slot faceplate: Using your fingers or a flathead
screwdriver, turn the screws securing the module (or faceplate on the slot) in a counter-clockwise direction until they are free of the chassis. Be sure not to completely remove the screws from the module or faceplate.
4. Remove the installed module or faceplate:
Firmly pull on the screws until the module is free of the switch. Carefully slide the module straight out of the slot.
Keep the original faceplate for future use. If you should remove the module, replace the faceplate to prevent dust and debris from entering the unit and to maintain proper air flow.
5. Insert the new module into the switch: Holding the new module with the text on the front panel upright, carefully slide the module into the switch slot and press gently until it snaps into place. Be sure the new modules front panel is flush with the switch panel.
6. Secure the new module: Secure the new module in place by screwing the attached screws clockwise into the switchs chassis. Tighten them enough to secure the module, but not so tight as to prevent them from being unscrewed by hand.
7. Insert the GBIC transceiver: Insert the tranceiver with the SC connector facing out toward you. Press in on the transceivers side tabs, and gently slide it into the GBIC interface slot until it clicks into place. Note that the transceiver is keyed so that it can only be installed in one orientation.
8. Connect the network cable: Connect fiber cable to the SC-type port on the GBIC transceiver. See Connectivity Guidelines in this guide for further information.
9. Power on the switch: Reconnect the previously removed power sources to the switch. The switch’s front-panel LEDs should indicate the status of the new connection. Check the LED indicators for the fiber port on the GBIC transceiver to ensure that they are operating correctly. Refer to the table of LEDs in this guide for a description of the LED indications. If the module does not respond, see Troubleshooting below.
Note: If you need to replace a GBIC transceiver,
remove it from the slot by pressing in on the side tabs, and gently sliding the transceiver out.
More details concerning connection options and network applications can be found in the product’s User Guide. Information on the modules configuration options can be found in the Management Guide that is included with the base unit.
TROUBLESHOOTING
If you experience any problems with the module, check the following items before contacting Enterasys Technical Support:
Ensure the switch with the GBIC converter module and installed GBIC transceiver is powered up.
Ensure that the device attached to the GBIC transceiver is powered up and operating correctly.
Ensure that the GBIC converter module is properly seated in the interface slot on the switch, and that the GBIC transceiver is properly inserted in the module.
Verify that the attached device is configured to match the communication mode used by the transceiver (1 Gbps, and half or full duplex).
Check the connectors on both ends of the cable to be sure they are properly engaged. When attaching fiber cable to an SC-type port, be sure the plug clicks into place to ensure that it is properly seated.
Be sure the fiber terminators are clean. You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol. Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable.
Loading...