Enterasys ER16-SERC-04-AA Quick Start Manual

12
NOTICE
Enterasys Networks and its licensors reserve the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF ENTERASYS NETWORKS AND ITS LICENSORS HAVE BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
Enterasys Networks, Inc. 35 Industrial Way Rochester, NH 03866-5005
2001 by Enterasys Networks,Inc . All Rights Reserved Printed in the United States of America
Order Number: 9033749 September 2001
X-Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors. All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accord ance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense. WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
VCCI NOTICE
This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
CLASS A ITE NOTICE
WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
DECLARATION OF CONFORMITY
Application of Council Directive(s): 89/336/EEC
73/23/EEC
Manufacturer’s Name: Enterasys Networks, Inc.
Manufacturer’s Address: 35 Industrial Way
PO Box 5005 Rochester, NH 03867
European Representative Name: Mr. Jim Sims
European Representative Address: Enterasys Networks Ltd.
Nexus House, Newbury Business Park London Road, Newbury Berkshire RG14 2PZ, England
Conformance to Directive(s)/
Product Standards: EC Directive 89/336/EEC
EC Directive 73/23/EEC EN 55022 EN 55024 EN 60950 EN 60825
Equipment Type/Environment: Networking Equipment, for use in a
Commercial or Light Industrial Environment.
Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above directives.
AGENCY STANDARDS
Safety
Meets the requirements of UL 1950, CSA C22.2 No. 950, EN 6095 0, IEC 950, 73/23/EEC, and EN 60825.
Electromagnetic Compatibility
Compliant with the requirements of FCC Part 15, CSA C108.8, EN 55022, EN 61000-3-2, EN 61000-3-3, VCCI V-3, EN 55024, 89/336/EEC, and AS/NZS 3548.
ER16-SERC-04-AA
The ER16-SERC-04-AA Serial card provides wide area connectivity via 4 T1/E1 ports with compression. These ports have the same switching and routing capabilities as those provided by the ethernet line cards. The ports can switch at Layer-2, Layer-3, and Layer-4, and perform both destination-based and flow-based switching. All ports are capable of bridging at Layer-2, switching IP/IPX frames at Layer-3, and switching on Layer-4 flows.
SPECIFICATIONS
Ports
4 Serial ports with compression (up to 8MB per port)
ASIC Type
-AA (Advanced ASIC) DMAC, IPP, OPP
Network Interfaces
60-Pin D-shell supporting 2 serial ports per connector
Physical Dimensions
Size: 52.9 cm H x 2.9 W x 40.1 D (20.9 in. H x 1.15 W x 15.8 D) Weight: 2.72 kg (6.0 lbs)
Power Consumption
BTU/hr = 146.35 AC Volt Amps = 43.31
Temperature
Operating: 32° to 104° F (0° to 40° C) Storage: -22° to 194° F (-30° to 90° C)
Humidity
5% to 95% (non-condensing)
CONNECTIVITY GUIDELINES
LEDs
Table 1 Recommended Cable Types and Specifications
Cable Type Max. Length Connector
Serial V.35, EIA-530, EIA-449, X.21 60-Pin D-Shell
Table 2 LED Indicators
LED Condition Status
Online (2) Green The unit is operational and functioning properly. Offline (2) Amber The unit is not operational. You may remove the
unit from the chassis. Tx (4) Amber A frame was transmitted. Rx (4) Amber A frame was received. Link (4) Green A valid link is established on the port.
345
INSTALLING THE MODULE
Handling the Module
To prevent electrostatic damage, observe the following guidelines:
Do not remove the module from its packaging until you are ready to
install it.
Do not touch any of the modules pins, connectors or components.
Hold the module only by its edges or front panel.
Wear an anti-static wristband connected to a suitable earth ground whenever handling
the module.
Store or transport this module only in appropriate anti-static packaging.
Equipment Checklist
After unpacking the ER16-SERC-04-AA, check the contents of the box to be sure you received the following items:
One ER16-SERC-04-AA module in anti-static bag
One disposable anti-static wristband
Tools
This installation requires the following tool:
Preliminary Setup
Firmware Image Requirements
Version 8.3.0.0 or later.
CLI Setup
Enter the following command at the CLI before implementing any configur ations.
1. Type the following from Enable mode to enter Configuration mode Enable -> Configure #
2. You may now begin configuring ports on the ER16-SERC-04-AA. Refer to the
Enterasys X-Pedition Command Line Interface Reference Manual for details.
Hotswap
You may install this module into a live system without powering off the device. However, you may not remov e an active module from a live system except under the following conditions:
Press the Hotswap button. The Online LED will turn off and the Offline LED will
turn on.
OR...
Enter the following from the CLI and click enter: Enable -> System -> Hotswap ->
Out -> Slot -> #. The Online LED will turn off and the Offline LED will turn on.
Instructions
1. If a coverplate is installed in the slot where you will install the ER16-SERC-04-AA, remove the coverplate: loosen the screws on the ejectors until the screws pop out,
then open the ejectors and pull out the plate.
2. Open the ejectors at the top and bottom of the ER16-SERC-04-AA.
3. Align the metal backpanel with the card guides at the top and the bottom of the slot
opening, as shown in Figure 1.
4. Slide the ER16-SERC-04-AA all the way into the slot, firmly but gently pressing to ensure that the pins on the back of the module are completely seated in the backplane.
5. To lock the ER16-SERC-04-AA into the slot, close the ejectors. Usin g a flathead screwdriver, tighten the screw on each ejector.
Figure 1 Install the ER16-SERC-04-AA
TROUBLESHOOTING
Proper Boot Sequence
Firmwar e loads .
The control module for the chassis should indicate that the ER16-SERC-04-AA was
detected and is operating correctly.
The Online LED will turn on and remain lit (no other LEDs should illuminate during
module power-up).
Common Errors
The ER16-SERC-04-AA is not inserted properly or seated completely in the chassis
Connectors for the connected lines are not seated properly.
Helpful CLI Commands for Debugging
Syst em show hardware
System show version
Port show port status se.x.y (where x is the chassis slot that contains the line card
and y is a specific port number on the card).
System show bootlog
ADDITIONAL INFORMATION
For additional information about installing this module or to learn more about what capabilities are included in the firmware release you are using, visit the Enterasys Networks web site.
Getting Help
For additional support related to the Common CLI syntax or this document, contact Enterasys Networks using one of the following methods:
Before contacting Enterasys Networks for technical support, have the following information ready:
Your Enterasys Networks service contract number
A description of the failure
A description of any action(s) taken to resolve the problem (e.g., changing mode
switches, rebooting the unit)
The serial and revision numbers of all involved Enterasys Networks products in the
network
A description of your network environment (layout, cable type, etc.)
Network load and frame size at the time of tro uble (if known)
ELECTRICAL HAZARD: Only qualified personnel should perform installation procedures.
CAUTION: The ER16-SERC-0 4-AA is eas ily dam ag ed by electrostatic discharge.
Anti-static wristband Flathead screwdriver
CAUTION: Before performing any upgrade or installation, ensure
that you are properly “grounded” to avoid electrostatic discharge. The switch must be powered off before installing or replacing any module.
NOTE: Make sure that the metal backpanel of the ER16-SERC-04-AA— not the circuit card—is between the card guides. Check both the upper and lower tracks.
Rotate ejector to lock in place
Metal
Backpanel
Card
Guides
Circuit Card
TX RX LINK
1 2
ONLINE
OFFLINE
HOT SWAP
World Wide Web http://www.enterasys.com/ Phone (603) 332-9400 Internet mail support@enterasys.com
FTP
Login Password
ftp://ftp.enterasys.com anonymous your email address
To acquire the latest image for this product and any available release notes
http://www.enterasys.com/download
Additional documentation http://www.enterasys.com/support/manuals
To send comments or suggestions concerning this document, contact the Technical Writing Department via the following email address:
TechWriting@enterasys.com
Please include the document Part Number in the email message.
ER16-SERC-04-AA
Quick Start
Web Site: http://www.enterasys.com/
9033749
Loading...