QUICK INSTALL GUIDE
(Models QD-CONN-10F and QD-CONN-10M)
Install the Enphase Three-Phase
Field Wireable Connectors
Use Enphase Three-Phase Field Wireable QD Connectors with an Enphase QD Cable or a 10AWG or a 12AWG eld extension cable to:
• Easily connect QD Cables on the roof without complex wiring
• Use a mated pair of connectors to end-feed the branch circuit with an AC connection
• Use a Male connector along with a QD-LINKFW-10 center tap adapter cable to center-feed the branch circuit with an AC connection
• Use mated pairs of connectors to connect with a remote part of the array
PREPARATION
For full installation instructions for the Enphase IQ8D Microinverters, read and follow
all warnings and instructions in this guide and in the Enphase IQ8D Commercial PV
Design Guide and IQ8D Microinverter System manual at: enphase.com/support.
Check that you have Enphase Three-Phase Field Wireable QD Connectors as needed
for your installation. Both female and male connectors are sold in packs of ten:
• Three-Phase Field Wireable QD Connector (female): (QD-CONN-10F)
• Three-Phase Field Wireable QD Connector (male): (QD-CONN-10M)
Make sure you have the following recommended tools:
• Screwdriver blade width 4mm to 3.2mm (1/8”) (recommended tool to torque
the screw on contact carrier and to disconnect eld wireable connector).
• 30mm wrench
PARTS
FEMALE CONNECTOR PARTS
3
2
1
MALE CONNECTOR PARTS
4
1. Cable gland
2. Seal
3. Housing
4. Contact carriers
1. Cable gland
2. Seal
3. Housing
4. Contact carriers
WARNING: Risk of equipment failure. Do not mix
*
male and female connector parts when assembling connectors.
Corporate Headquarters Contact Information
Enphase Energy Inc.
47281 Bayside Parkway
Fremont, CA 94538 USA
© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase
logo, Enphase Field Wireable Connector, Enphase IQ8D Microinverters, and other trademarks or service names are the trademarks of
Enphase Energy, Inc. Data subject to change. Rev02-05-27-2022.
Enphase Customer Support: enphase.com/en-us/support/contact

ASSEMBLY
Follow the steps to assemble Enphase Field Wireable QD Connectors for three-phase.
FEMALE
A) Prepare the cable:
• Push the cable gland over the cable.
• If there are multiple seals, select a seal that ts your cable
diameter. Seal ranges are: 8-12mm / 12-16mm / 16-21mm.
• Push the housing with seal over the cable.
• Strip 42mm from the cable.
• Strip 12mm from the conductors.
NOTE : Do not use PE pin when using connector with 4 core QD
Cable.
B) Connect the conductors to the contact carrier. Match the assign-
ment according to the label on the contact carrier.
WARNING: Ensure that the correct connection for Line, Neutral,
*
match according to the label on the contact carrier. In case of
mismatch, phase balance of system will be affected.
NOTE: For exible wires, we recommend using ferrules acc. to
DIN 46228 that are crimped with jointing clamp.
C) Torque the contact carrier screws to 1 Nm.
MALE
D) Push the contact carrier into the housing until it snaps in audibly.
E) Tighten the cable gland to a torque of 4.5 Nm.
WARNING: Observe the permitted bending radius during installation.
*
The degree of protection might fail if the bend radius is exceeded.
r
4 xd
min
4.5 Nm
30
d
Loosening the cable
• Loosen the cable gland.
• Use the screwdriver to release the contact carrier on both sides.
• Pull the contact carrier from the housing.
• Loosen the screws on the contact carrier, and loosen the wires.

-
FIELD WIREABLE QD CONNECTORS - THREE-PHASE
DISCONNECT (if needed)
To disconnect Enphase Three-Phase Field Wireable QD Connectors,
release the two connectors by pressing down the snap with a screwdriver. You can then separate the connectors
* WARNING: Never plug in or disconnect the connectors under load.
The connectors are not suitable for interrupting the current.
SAFETY
IMPORTANT SAFETY INSTRUCTIONS.
SAVE THIS INFORMATION.
Follow all safety and assembly instructions when installing Enphase Three-Phase Field Wireable QD Connectors.
Safety Symbols
DANGER: This indicates a hazardous situation, which if
+
not avoided, will result in death or serious injury.
WARNING: This indicates a situation where failure to
*
follow instructions may be a safety hazard or cause
equipment malfunction. Use extreme caution and follow
instructions carefully.
WARNING: Risk of burn. Failure to follow instructions
;
may result in burn injury.
NOTE: This indicates information particularly important
✓
for optimal system operation.
Safety Instructions
DANGER: Risk of electric shock. Do not use Enphase
+
equipment in a manner not specied by the manufacturer.
Doing so may cause death or injury to persons, or damage
to equipment.
DANGER: Risk of electric shock. Be aware that installation
+
of this equipment includes risk of electric shock. Do not use
without rst removing AC power from the Enphase System.
Disconnect the power coming from the photovoltaics
before servicing or installing.
DANGER: Risk of electric shock. Never plug in or disconnect
+
the connectors under load. The connectors are not suitable
for interrupting the current.
DANGER: Risk of electric shock. Risk of re. Before making
+
any connections verify that the circuit breakers are in the off
position. Double check all wiring before applying power.
DANGER: Risk of electric shock. Risk of re. Only use
+
electrical system components approved for wet locations,
including but not limited to conduit ttings.
DANGER: Risk of electric shock. Risk of re. Only qualied
+
personnel should install, troubleshoot, or replace the Enphase Three-Phase Field Wireable QD Connector.
DANGER: Risk of electric shock. Improper use of the Three-
+
Phase Field Wireable QD Connector or its components may
result in a shock, re or explosion. To reduce these risks,
disconnect all wiring before attempting any maintenance.
DANGER: Risk of electric shock. Risk of re. Ensure that all
+
AC and DC wiring is correct and that none of the AC wires
are pinched, shorted, or damaged.
DANGER: Risk of electric shock. Risk of re. Do not attempt
+
to repair or alter the Enphase Three-Phase Field Wireable
QD Connector.
DANGER: Risk of electric shock. Risk of re. Make sure the
+
conductors are not damaged. If the exposed wires are damaged, the system may not function properly.
WARNING: Risk of equipment damage. Enphase male and
*
female connectors must only be mated with the matching
male/female connector.
WARNING: Risk of equipment damage. This product is
*
intended for operation in an environment having a maximum
ambient temperature of 105°C(221°F).
WARNING: When installing the cabling, secure any loose
*
cable to minimize tripping hazard
WARNING: Before installing or using the Enphase Three-
*
Phase Field Wireable QD Connector, read all instructions
and cautionary markings in the technical description, on the
Enphase System, and on the photovoltaic (PV) equipment.
WARNING: For eld connections, use 10 or 12 AWG wires
*
insulated for a minimum of 75°C.
NOTE: Using unapproved attachments or accessories may
✓
result in damage or injury.
NOTE: When looping the Enphase QD Cable, do not form
✓
loops smaller than 3.62 inches (9.2 cm) in diameter.
NOTE: Perform all electrical installations in accordance with
✓
all applicable local electrical codes: the Canadian Electrical Code, part 1; the National Electrical Code (NEC); ANSI
requirements; and NFPA 70.
NOTE: To ensure optimal reliability and to meet warranty re-
✓
quirements, install the Enphase Three-Phase Field Wireable
QD Connectors according to the instructions in this guide.
NOTE: Protection against lightning and resulting voltage
✓
surge must be in accordance with local standards.
NOTE: For exible wires, we recommend using ferrules acc.
✓
to DIN 46228 that are crimped with jointing clamp.
NOTE: Cable used with Enphase Three-Phase Field Wireable
✓
QD Connectors must meet the following requirements:
• Min/max outer insulation diameter (including the
clear second insulator): 8mm / 21mm
• Wire size: 12 AWG to 10 AWG
Enphase Customer Support: enphase.com/en-us/support/contact