Audience
This manual is intended for use by professional installat io n and maint enance perso nnel.
2 2015 © Enphase Energy 140-00067- 02
Installa tion Guide
Contents
Safety Warnings 4
Microinvert er Safety 4 Engage Cable and Accessory Safety 5 Pho tovoltaic (PV) Safet y 6
About the Enphase Frame Mount and Connector Clip 7
Installing the Frame Mount and Connector Clip 8
Enphase Frame Mount Kit Part s List 8 Other Part s 8 Tools Needed 8 Where to Place the Microinverter and Dro p Connector 8 How to Inst all the Frame Mount and Connector Clip 9
3 2015 © Enphase Energy 140-00067- 02
Installa tion Guide Saf ety W a rnings
Safety Warnings
To reduce t he risk of electrical shock or injury , and to ensure the safe inst allation of the Enphase Frame Mount and Co nnect or Clip, follow these instructions. The following safety symbols and information indicate dangerous conditions and important safety instruct io ns.
Safety and Advisory Symbols
NOTE: This indicates info rmat io n part icularly import ant for opt imal system operation. Follow inst ructions carefully
DANGER! This indicat es a hazardo us situation, which if not av o ided, will result in death or serio us injury.
WARNING! This indicates a sit uat ion where failure to follow inst ructions may be a safety hazard o r cause equipment malfunction. Use extreme caution and follow instructions carefully.
WARNING! This indicates a sit uat ion where failure to follow inst ructions may result in burn injury.
Microinverter Safety
WARNING: To reduce the risk of electrical shock, and to ensure the safe install­ation and operation of the Enphase Microinverter, read and follow the all instructions in the Enphase Microinverter Installation and Operation and the photovoltaic (PV) equipment manuals before installing or using the Enphase Microinverter.
WARNING: Risk o f skin burn. The body of the micr oinverter is t he heat sink. Under normal operating co nditions, the temperature is 15°C above ambient, but under extreme co nditions t he micro inv erter can reach a t em­perature of 80°C. To reduce r isk of burns, use caution when working with microinvert ers.
WARNING: Risk of electric shock. Risk of fire. If the AC cable on the microin­verter is damaged, do not install it.
DANGER: Risk of Electrical Shock. Be aware that installationof this equipment includes risk of electric shock. Do not install the AC junction box without first removing AC power from the Enphase System.
WARNING: Risk o f equipment damage. The microinvert er must be inst alled under the module, out of rain and sun. Do not mount the microin­vert er in a position that allows long-term exposure to direct sunlig ht or in a v ertical o rientation that allows water t o collect in the DC connector recess. Do not inst all the microinvert er black side up or v ertically, with t he DC connectors facing up.
4 2015 © Enphase Energy 140-0 0067-02
Sa fety Warnings Installa tion Guide
Engage Cable and Accessory Safety
WARNING: Risk of electric shock. Always remove power from the Enphase Microinverter System before servicing. Never disconnect or remove the termin­ator cap.
CAUT ION: When installing the Engage Cable, secure any lo ose cable to minimize tripping haz ard.
WARNING: T ripping Hazard. Lo ose cables can become a t ripping hazard. Dres s the Engage Cable to minimize this po t ent ial.
NOTE: When you dress the Engage Cable, adher e to the following r equire­ments:
l Do not expose the cable connectio ns to cont inuous immersion. l Use t he cable and co nnect ors only when all p ar t s are present
and int act .
l Do not expose the t erminator cap or cable connections to
continuous tens ion (e.g., t ension due t o pulling or bend ing the cable near the connectio n) .
l Use o nly t he co nnect o rs and cables provided. l Do not allow cont am inatio n o r debr is in t he co nnect o rs. l Do not ins t all o r use in po t entially exp lo s ive env iro nm ents. l Do not allow the t erminator t o co me int o cont act wit h open
flame.
l Do not expose the t erminator cap or cable connections to
direct ed, pres suriz ed liquid ( like a water jet fr o m a hose nozz le).
NOTE: There are two release-holes in the Engage Cableconnector. These are not for mounting but are used to disconnect the connector. Keep these release holes clear andaccessible.
NOTE: When looping t he Engage Cable, do no t form loops smaller than
4.75 inches (12 cm) in diameter.
NOTE: Do not use the shipping cap t o cover unused connect ors. The ship­ping cap does not prov ide an adequate environmental seal. Enphase sealing caps are requir ed to prot ect against moisture ingress.
140-00067- 02 2015 © Enphase Ener gy 5
Installa tion Guide Saf ety W a rnings
Photovoltaic (PV) Safety
DANGER: Risk of injury. PV module connectors, when energized, may cause fire,spark or lethal shocks even when the modules are not connected.
DANGER: Risk of electric s hock. Mo dules generate electricity when the modules ar e exposed to sunlight, even if t hey are not connected. I t is dan­gerous to touch 3 0V DC or higher, s o never open t he electrical con­nectors or unplug t he elect rical connectors while the circuit is under load, and do not to uch the connector ends.
NOTE: Wear gloves when handling the module.
NOTE: Do not lift or move t he mo dule by holding the frame mount.
NOTE: Do not place anything on the module or press on the module surface.
NOTE: Do not drop the module o r allo w object s t o fall on the module.
NOTE: Do not handle the modules in wet or strong windy co nditions.
6 2015 © Enphase Energy 140-0 0067-02
About the En ph ase F ra me Mou nt a nd Conne c tor Clip Installa tion Guide
About the Enphase Frame Mount and Connector Clip
The Enphase Frame Mount and Connector Clip Kit allows y o u to att ach an Enphase Microinvert er easily and rapidly t o the PVmodule frame whether you are on the ground or on the ro of.
You can use t he Frame Mount in rail-free or ballast ed solar installations.
The Connector Clip secures t he Engage drop connecto r directly to the module frame.
The Frame Mount co mes in two siz es, 35 mm and 40 mm, depending upon t he thickness (depth) o f t he PV module frame.
WARNING! If you att ach t he microinverters to PV module frames while on the ground, use caution when moving t he PV module/microinvert er units to the roof. Adhere to t he follo wing guidelines when moving PV modules with attached microinverters:
l Secur e all cables wit h tape or cable ties t o pr event a trip hazar d. l Do not stack P V module/micr o inverter units on the r o o f. l Handle t he PV module/micronver t er unit s carefully t o av o id
damaging t he micr o invert er , bracket , or connect or clip.
140-00067- 02 2015 © Enphase Ener gy 7
Installa tion Guide Installing th e Fra me Mou nt a nd Connec tor Clip
Installing the Frame Mount and Connector Clip
Enphase Frame Mount Kit Parts List
l Frame mo unt br acket l Frame mo unt br acket clamp, 3 5 mm or 4 0 mm l Hex head set bolt l Connect or Clip
Other Parts
l Enphas e Microinver t er l Engag e Cable l PV Mo d ule
Tools Needed
13mm (1 /2-in) so cket wrench
Where to Place the Microinverter and Drop Con­nector
In a standard array, place the:
l Microinv ert er w ith the Fr ame Mount app roximat ely 18cm (7in) in from
the edg e o f t he PV module.
l Engag e connect or dro p using t he Connector Clip appro x imately 3 0 cm
(1 2 in) from the corner of the PV mo dule. Yo u may need to adjust the dist ance if it inter feres w ith m ount ing t he PV module on the r acking.
8 2015 © Enphase Energy 140-0 0067-02
Installing th e Fra me Mount a nd Con nec to r Clip Insta lla tion Guide
How to Install the Frame Mount and Connector Clip
WARNING: DO NOT connect Enphase Micro inv erters to the utility grid or energ iz e t he AC circuit(s) until you have completed all of the installation procedures described in the Enphase Microinvert er Inst allation and Oper­ations Manual.
1. Place t he bracket clamp over t he edge of t he mo d ule frame.
2. Thread t he cap bolt int o the t hreaded insert o n t he br acket, then slide mid dle channel of t he microinv ert er o nt o the bo lt .
3. Slide the micr o invert er unit o nt o t he br acket clamp, t hen mov e it slight ly t o the left. T he bo lt now holds the frame mount t o the br acket clamp. The micro inver t er mount ing flang e should be on the o ut sid e o f the module fr ame.
140-00067- 02 2015 © Enphase Ener gy 9
Installa tion Guide Installing th e Fra me Mou nt a nd Connec tor Clip
4. With a 1 3mm or 1 /2 inch socket w rench, t ighten t he cap screw unt il you reach a torque o f 1 8 Nm ( 1 3 ft-lbs ).
5. Neat ly coil t he mo dule wir es and secur e wit h a wire clip.
NOTE: When looping t he Engage Cable, do no t form lo ops smaller than 12 cm (4 .75 inches) in diameter.
6. Connect the micro inver t er DC connectors to the P V mo dule.
CAUT ION: When installing t he Engage Cable, s ecure any loose cable to minimize tr ipping hazard.
Dres s the Engage Cable so that it does not co ntact the roof. Refer to t he Enphase Microinverter Installat io n and Operation Manual for det ails.
7. Aft er yo u hav e installed the module, connect t he Eng age drop connector to t he micr o inverter . Listen fo r t w o clicks as the connectors engag e.
8. Clip the Engag e Cable drop co nnect o r into t he co nnect o r clip.
10 2015 © Enphase Energy 140-0 0067-02
Installing th e Fra me Mount a nd Con nec to r Clip Insta lla tion Guide
9. Attach t he co nnect or clip o nt o the underside of t he module frame.
10 . Secure the Engag e Cab le t o the module frame with wire clips as
needed .
140-00067- 02 2015 © Enphase Ener gy 11