PDU Safety Guidelines
This document is intended for installers, maintenance professionals, and qualied users of Enlogic power distribuon units
(PDUs). Keep this safety informaon for operaon, installaon, and maintenance of the PDU and accessory equipment. This
product complies with the latest safety requirements for equipment and accessories for use in a rack mounng environment.
Read and follow all safety informaon. Failure to do so may result in death or serious injury.
• Electrical Hazard: this PDU contains high voltages. Repairs and service to this PDU should only be performed by
authorized service providers. This includes installation, testing, and maintenance of internal and external parts.
• There is a risk of electrical shock from ground conductor leakage. If the total leakage current exceeds 3.5 mA or
if leakage current of the connected load is unknown, connect the ground terminal of the PDU to a dependable
ground/earth connection. The ground terminal on the PDU is an M5 screw hole with a maximum depth of 9mm.
• This equipment must be connected to an electrical supply with protected ground outlets and a branch circuit
breaker with the same current rating as the equipment. Test all outlets for proper polarity and grounding.
Failure to comply with this requirement may result in serious injury.
• This power distribution unit is intended for providing power to ITE equipment only. Do not connect secondary
power units to the outlets of the PDU.
• Make sure the utility power outlet is in good condition.
• Make sure the PDU power cord and plug are in good condition.
• Make sure the power input is disconnected before physically mounting or moving the location of this product. If
the PDU has detachable input power cords, only use power cords supplied by Enlogic.
• Internal parts of the PDU may get extremely hot during operation. Use care before handling.
• Changes and modifications to this equipment could void the warranty. Enlogic is not responsible for damage to
this product resulting from accident, disaster, or misuse. Note: If the product is a switched model, power may
be present at a receptacle even when it is switched off.
Follow all local and naonal codes when installing the PDU. The PDU should be connected to a dedicated circuit protected by a
branch circuit breaker matching the PDU input plug type for your region:
Regions PDU Input Plug Type Branch Circuit Breaker Required
Europe, International
IEC60320 C20 Inlet (Removable Power Cord) 16A single-pole
CEE 7/4, CEE 7/5, CEE 7/7 Plugs 16A single-pole
IEC60309 316P6 or 316P6W 16A single-pole
IEC60309 332P6 or 332P6W 32A single-pole
IEC60309 363P6 or 363P6W 63A single-pole
IEC60309 516P6 or 516P6W 16A three-pole
IEC60309 532P6 or 532P6W 32A three-pole
IEC60309 563P6 or 563P6W 63A single-pole
Australia
3-pin (2P+G) 20A single-pole
3-pin (2P+G) 32A single-pole
5-pin (3P+N+G) 20A three-poles
5-pin (3P+N+G) 32A three-poles
North America/Japan
IEC60320 C20 Inlet (Removable Power Cord) 20A single-pole
NEMA 5-20P or NEMA L5-20P 20A single-pole
NEMA 6-20P or NEMA L6-20P 20A double-pole
NEMA 6-30P or NEMA L6-30P 30A double-pole
NEMA 5-30P or NEMA L5-30P 30A single-pole
IEC60309 330P9 or 330P9W 30A double-pole
NEMA L21-20P or NEMA L15-20P 20A three-pole
NEMA L21-30P or NEMA L15-30P 30A three-pole
CS8365 50A three-pole
IEC60309 460P9 or 460P9W 60A three-pole
IEC60309 520P6 or 520P6W 20A three-pole
IEC60309 530P6 or 530P6W or NEMA L22-30 30A three-pole