ENFORCER IP Surge Protector
4 SECO-LARM U.S.A., Inc.
to an image processor (e.g., multiplexer
or DVR), but not if connected directly to
the monitor.
• Move the cable away from possible sources of interference.
• Replace the cable with a new cable.
• Ensure that the protected cable is as short as possible
Video image background flutters
between dark and light.
• Remove a local power source, or adjust the monitor’s
brightness and contrast.
Video image is weak or faded.
• Reduce the cable length.
• Replace with a higher-grade cable. Cat5 cable meets the
specifications in the manual. Cat6 cable allows longer
range.
No video image.
• Double-check that the cables were connected properly.
• Run a continuity test on all wires in the cable.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
E-mail: sales@seco-larm.com
: The information and specifications printed in this manual are current at the time of publication. However, the SECO-
one of continual development and improvement. For this reason, SECO-LARM reserves the rig ht to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-
LARM U.S.A., Inc. All rights reserved. This material may not be reprod uced or copied, in whole or in part, without the
written permission of SECO
: Users and installers of this product are responsible for ensuring this product complies with all national, st ate, and local
laws and statutes related to monitoring and recording audio and video signals. SECO-LA RM will not be held responsible for the use of this
product in violation of any current laws or statutes.
: Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause a d angerous electric shock,
damage the device, and void the warranty. Do not open the case of this device, as there are no field-serviceable components inside.
: This SECO-LARM product is warranted against defects in material and workmanship while used in n ormal service for a
period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’ s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SE CO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical m isuse or abuse, neglect, repair, or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating
properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limi ted to replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or co nsequential personal or property damages of any
kind to the purchaser or anyone else.
Helps prevent damage to sensitive computer or CCTV equipment
such as cameras, monitors, digital video recorders, video splitters,
PCs, servers or networking hubs
• Intercepts repeated surges and spikes that could damage network
equipment
• Installs on Cat5e/6 4-pair UTP cable with RJ45 jacks
• Passive operation – no external power required
• Includes a grounding post

ENFORCER IP Surge Protector
2 SECO-LARM U.S.A., Inc.
Protector is a passive device that helps protect sensitive networking
equipment from power surges. The device can be deployed in new installations or added to
existing ones.
The IPV-PD88Q IP Surge Protector should be installed between devices connected by Cat5e/6
4-pair UTP cable to protect against surges that could damage computer or video equipment.
NOTE
: For the best protection, installing two surge protectors is recommended: one at each end of
10,000MΩ Maximum surge voltage
100A Surge protection time
Signal passing
capability
In RJ45 Out RJ45 Impedance
37/16”x25/8”x11/16” (87x67x27 mm)
25/8” (67mm)
25/8” (67mm)
11/16”
(27mm)
ENFORCER IP Surge Protector
SECO-LARM U.S.A., Inc. 3
Protecting Multiple Devices:
1. Mount the IP Surge Protector as close as possible to the device to be protected.
2. Detach the Cat5e/6 cable from the device to be protected and attach to the “Unprotected” port
of the IP Surge Protector.
3. Attach an additional short Cat5e/6 cable between the device to be protected and the
“Protected” port of the IP Surge Protector. This cable should be as short as possible to connect
the two devices. In addition the protected cables should not cross unprotected cables.
4. Use supplied ground cable to connect the ground (GND) terminal to earth ground. The system
should use a single ground point and the protected device should be isolated from ground.
Protecting a Single Device:
End
To ground
Original Cat5e/6 cable
(Protected)
Unprotected End
1. Mount the two IP Surge Protectors as close as possible to each device to be protected.
2. Detach the Cat5e/6 cable from each device to be protected (such as an IP switch
and attach to the “Unprotected” port on its respective IP Surge Protector.
3. Using additional short Cat5e/6 cables, connect each device to be protected to the “Protected”
end of its respective IP Surge Protector. These cables should be as short as possible to
connect each device to its respective surge protector. In addition the protected cables should
not cross unprotected cables.
4. Use supplied ground cable to connect each IP Surge Protector’s ground (GND) terminal to
earth ground. The system should use a single ground point and the protected device should be
isolated from ground.