ENFORCER KX25LR-WE User Manual

RINS1594-2
KX25LR-WE 25m Internal detector
WHITE
3mmABS, 0.4mm HDPE in lens area
868MHz, FM Transceiver Narrow Band
Fully Encrypted Rolling Code
300m Free Space
High, Low
Advanced Automatic
25m
46
0.3 - 3.0 m/s
90
CR123A Lithium Battery
Greater than 2 years
2.4m
Front and RearTamper
-20°C to 50°C
-10°C to 40°C
-10°C to 50°C
Wall and ceiling mounting brackets optional
EN55022 Class B / EN50130-4
Model:
Colour:
Casing:
Transmission Frequency:
Tranmission Method:
Transmission Range:
Detection Method:
Sensitivity:
Temperature Compensation:
Detection Range:
Detection Zones:
Detection Speed:
Detection Angle:
Battery:
Battery Life:
Mounting Height:
Tamper Switch:
Accessories:
Emissions / Immunity:
Pyronix Limited, Secure House, Braithwell Way,
Hellaby, Rotherham, S66 8QY. UK
Customer Support Line : +44(0)845 6434 999
or telephone +44(0)1709 535225
E-mail: customer.support@pyronix.com
website: www.pyronix.com
WARRANTY
This product is sold subject to our standard warranty
conditions and is warranted against defects in
workmanship for a period of two years
In the interest of continuing improvement of quality,
customer care and design, Pyronix Ltd reserves the
right to amend specifications, without giving prior
notice.
(batteries
excluded)
This product is approved for use in the Residential,
Commercial and Light Industrial Environment.
.
Coverage Pattern
®
EN50131-2-2:2008 EN50131-5-3:2005+A1:2008
Security Grade 2 Environmental Class II
Suitable for use in systems installed
to conform to PD6662:2010
NOTE: Only the KX25LRHT-WE has
been certified by IMQ.
2
®
KX25LR-WE Specifications
®
KX25LR-WE
25m Two Way Wireless Long
Range Corridor PIR Detector
Storage Temperature:
Certified Operating Temp:
Nominal Working Temp:
2.5V +/- 5% at 25
°C
Low Battery Threshold:
0.8m
1.3m
2.3m
3.8m
6
.0
m
6.
6m
10.5m
11
.
0M
17.0m
2.4m
5m
15m
25m
25m
18m
0m
17m
16m
15m
14m
13m
12m
11m
10m
9m
8m
7m
6m
5m
4m
3m
2m
1m
1m
2m
3m
4m
5m
6m
7m
8m
9m
10m
11m
12m
13m
14m
15m
16m
17m
18m
1m
10m
20m
O
90 46 z ones 6 plane s
VERTICAL COVERAGE
HORIZONTAL COVERAGE
CASE LID
SCREW FITTING
NOTE: When mounting the
Part number: FPKXBRACKET
WallCeiling
detector, ensure that it is not tilting backwards.
Installation Wall Mounting
The KX25LR-WE Printed Circuit Board
Learning the KX25LR-WE onto the Enforcer 32-WE Control Panel
Changing The Battery
Optional Bracket Fitting Dimensions Avoiding False Alarms
69mm (2.72”)
3mm (0.12")
50mm (2.2”)
117mm (4.61”)
Kg
= 105g (3.4 oz) without bracket
RINS1594-2
Header On
= HIGH)
Header Off
= LOW
SENSITIVITY
DIGITAL SIGNAL PROCESSING SELECT
Header On
LED ON
LED OFF
Header Off
ALARM LED
To prevent possible damage to components,
any static charge on your body needs to be eliminated before touching the inside of the unit. This can be accomplished by touching some grounded/earthed metallic conductor
such as a radiator/pipework immediately
before replacing the batteries.
The batteries supplied have been chosen to
provide long service life whilst, for safety
reasons, having limited output current.
Replace only with approved batteries.
Tamper Spring
Alarm LED ON/OFF
Sensitivity Settings
Piro Sensor
DO NOT TOUCH
Learn Button
Battery
Header for Rear Tamper
+
-
When you are ready to learn the device to the control panel receiving equipment, and when the equipment is in the learn mode follow the procedure below:
1. Make sure the battery is installed correctly and the plastic wrapping removed.
2. Press and Hold the Learn button until the 3 LEDs start cycling through the different colours, then release the Learn button.
3. The device is correctly learnt when the Green LED flashes.
The three coloured LEDs give a visual indication of the signal strength.
Green indicates good signal strength and is a good location to install.
Red indicates poor signal strength and the device should not be installed in that position.
If no LED illuminates then the device is completely out of range.
RED BLUE GREEN
The blue LED will illuminate when the device is activated.
For electrical products sold
within the European
Community. At the end of the
electrical products life, it
should not be disposed of
with household waste. Please
recycle where facilities exist.
Check with your Local
Authority or retailer for
recycling advice in your
country.
RED BLUE GREEN
RED BLUE GREEN
RED BLUE GREEN
RED BLUE GREEN
mralA
CR123A LITHIUM BATTERY
+
-
REAR TAMPER
NVM RESET
CR123A LITHIUM BATTERY
+
-
1. Avoid placing the detector in direct sunlight.
2. Do not let pets and other animals wander freely whilst the alarm system is armed.
3. Do not mount the detector near heaters or
radiators.
4. Do not mount the detector near open windows or air vents.
5. Mount the detector on a stable surface.
6. Do not partially or completely obscure the detectors field of vision with large objects.
When disposing of the
product, the battery must be
removed and disposed of
separately in accordance
with the local regulations
Please see the control panel user, programming and quick set up manuals for further information