Enforcer EWHIK16EA User Manual

SAFETY DATA SHEET
Enforcer(R) Instant Knockdown Wasp & Hornet Killer
Version 2.0
Print Date 08/08/2016
Material name
:
Enforcer(R) Instant Knockdown Wasp & Hornet Killer
EPA ID Number:
40849-77 Material number
:
000000000001045839
Company
:
Zep Commercial Sales & Service, a unit of Zep, Inc.
Address
:
1310 Seaboard Industrial Blvd., NW Atlanta, GA 30318
Telephone
:
404-352-1680
Emergency telephone numbers
For SDS Information
:
Compliance Services 1-877-428-9937
For a Medical Emergency
:
877-541-2016 Toll Free - All Calls Recorded
For a Transportation Emergency
:
CHEMTREC: 800-424-9300 - All Calls Recorded. In the District of Columbia 202-483-7616
Recommended use
:
Pesticide Appearance
Aerosol containing a compressed gas
Colour
clear, white
Odour
slight, characteristic
Flammable aerosols
:
Category 1
Gases under pressure
:
Compressed gas
Hazard pictograms
:
Signal word
:
Danger
Hazard statements
:
H222 Extremely flammable aerosol. H280 Contains gas under pressure; may explode if heated.
Precautionary statements
:
Prevention: P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking. P211 Do not spray on an open flame or other ignition source.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
Recommended use of the chemical and restrictions on use
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS label elements
1 / 11
SAFETY DATA SHEET
Enforcer(R) Instant Knockdown Wasp & Hornet Killer
Version 2.0
Print Date 08/08/2016
P251 Pressurized container: Do not pierce or burn, even after use. Storage: P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F.
Substance / Mixture
:
Mixture
Chemical name
CAS-No.
Concentration [%]
Distillates (petroleum), hydrotreated light
64742-47-8
>= 70 - < 90
Solvent naphtha (petroleum), heavy aliph.
64742-96-7
>= 5 - < 10
carbon dioxide
124-38-9
>= 1 - < 5
m-phenoxybenzyl 3-(2,2-dichlorovinyl)-2,2­dimethylcyclopropanecarboxylate
52645-53-1
>= 0.1 - < 1
General advice
:
Move out of dangerous area. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.
If inhaled
:
If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician. Move to fresh air.
In case of skin contact
:
Take off contaminated clothing and shoes immediately. Wash contaminated clothing before re-use. If symptoms persist, call a physician. Wash off immediately with plenty of water for at least 15 minutes.
In case of eye contact
:
Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist. If in eyes, rinse with water for 15 minutes.
If swallowed
:
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. DO NOT induce vomiting unless directed to do so by a physician or poison control center.
Suitable extinguishing media
:
Alcohol-resistant foam Carbon dioxide (CO2)
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
The exact percentages of disclosed substances are withheld as trade secrets.
SECTION 4. FIRST AID MEASURES
SECTION 5. FIREFIGHTING MEASURES
2 / 11
SAFETY DATA SHEET
Enforcer(R) Instant Knockdown Wasp & Hornet Killer
Version 2.0
Print Date 08/08/2016
Dry chemical Water spray jet
Unsuitable extinguishing media
:
High volume water jet
Specific hazards during firefighting
:
Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion products
:
Carbon dioxide (CO2) Carbon monoxide Smoke
Specific extinguishing methods
:
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Further information
:
For safety reasons in case of fire, cans should be stored separately in closed containments. Use a water spray to cool fully closed containers.
Special protective equipment for firefighters
:
Wear self-contained breathing apparatus for firefighting if necessary.
Personal precautions, protective equipment and emergency procedures
:
Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Environmental precautions
:
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and materials for containment and cleaning up
:
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Sweep up or vacuum up spillage and collect in suitable container for disposal.
Advice on safe handling
:
For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Open drum carefully as content may be under pressure. Dispose of rinse water in accordance with local and national regulations. Do not breathe vapours or spray mist. Always replace cap after use.
SECTION 6. ACCIDENTAL RELEASE MEASURES
SECTION 7. HANDLING AND STORAGE
3 / 11
SAFETY DATA SHEET
Enforcer(R) Instant Knockdown Wasp & Hornet Killer
Version 2.0
Print Date 08/08/2016
Conditions for safe storage
:
BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. No smoking. Observe label precautions. Keep in a dry, cool and well-ventilated place. Electrical installations / working materials must comply with the technological safety standards.
Materials to avoid
:
Oxidizing agents
Components
CAS-No.
Value type (Form of exposure)
Control parameters / Permissible concentration
Basis
Distillates (petroleum), hydrotreated light
64742-47-8
TWA
500 ppm 2,000 mg/m3
OSHA Z-1
TWA
400 ppm 1,600 mg/m3
OSHA P0
carbon dioxide
124-38-9
TWA
5,000 ppm
ACGIH
STEL
30,000 ppm
ACGIH
TWA
5,000 ppm 9,000 mg/m3
NIOSH REL
ST
30,000 ppm 54,000 mg/m3
NIOSH REL
TWA
5,000 ppm 9,000 mg/m3
OSHA Z-1
TWA
10,000 ppm 18,000 mg/m3
OSHA P0
STEL
30,000 ppm 54,000 mg/m3
OSHA P0
Engineering measures
:
effective ventilation in all processing areas
Respiratory protection
:
In case of insufficient ventilation, wear suitable respiratory equipment.
Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines.
Remarks
:
The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye protection
:
Safety glasses Ensure that eyewash stations and safety showers are close to
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
Hazardous components without workplace control parameters
Personal protective equipment
Hand protection
4 / 11
Loading...
+ 7 hidden pages