Enforcer EBMFOG2 User Manual

SAFETY DATA SHEET
Enforcer (R) BugMax (R) Fogger
Version 1.0
Print Date 05/09/2017
Material name
:
Enforcer (R) BugMax (R) Fogger
EPA ID Number:
1021-2762-40849 Material number
:
000000000001047965
Company
:
Zep Commercial Sales & Service, a unit of Zep, Inc.
Address
:
1310 Seaboard Industrial Blvd., NW Atlanta, GA 30318
Telephone
:
404-352-1680
Emergency telephone numbers
For SDS Information
:
Compliance Services 1-877-428-9937
For a Medical Emergency
:
877-541-2016 Toll Free - All Calls Recorded
For a Transportation Emergency
:
CHEMTREC: 800-424-9300 - All Calls Recorded. In the District of Columbia 202-483-7616
Appearance
Aerosol containing a liquefied gas
Colour
opaque, white
Odour
characteristic
Flammable aerosols
:
Category 1
Gases under pressure
:
Liquefied gas
Respiratory sensitisation
:
Category 1
Hazard pictograms
:
Signal word
:
Danger
Hazard statements
:
H222 Extremely flammable aerosol. H280 Contains gas under pressure; may explode if heated. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
Precautionary statements
:
Prevention: P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 Do not spray on an open flame or other ignition source.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Manufacturer or supplier's details
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview
GHS Classification
GHS Label element
1 / 11
SAFETY DATA SHEET
Enforcer (R) BugMax (R) Fogger
Version 1.0
Print Date 05/09/2017
P251 Pressurized container: Do not pierce or burn, even after use. P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P285 In case of inadequate ventilation wear respiratory protection.
Response:
P304 + P341 IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. P342 + P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/ physician. Storage: P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F. Disposal: P501 Dispose of contents/container in accordance with local regulation.
IARC
No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
ACGIH
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
OSHA
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA.
NTP
No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
Substance / Mixture
:
Mixture
Chemical Name
CAS-No.
Concentration [%]
propane
74-98-6
>= 20 - < 30
butane
106-97-8
>= 10 - < 20
alkanes, C12-14-iso-
68551-19-9
>= 10 - < 20
Cypermethrin
52315-07-8
>= 0.1 - < 1
General advice
:
Move out of dangerous area. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended. If inhaled
:
If symptoms persist, call a physician.
Potential Health Effects
Carcinogenicity:
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous components
SECTION 4. FIRST AID MEASURES
2 / 11
SAFETY DATA SHEET
Enforcer (R) BugMax (R) Fogger
Version 1.0
Print Date 05/09/2017
If unconscious place in recovery position and seek medical advice.
In case of skin contact
:
Wash off immediately with plenty of water for at least 15 minutes. If on clothes, remove clothes. If skin irritation persists, call a physician.
In case of eye contact
:
Rinse immediately with plenty of water for at least 15 minutes. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
If swallowed
:
Keep respiratory tract clear. DO NOT induce vomiting unless directed to do so by a physician or poison control center. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
Suitable extinguishing media
:
Alcohol-resistant foam Carbon dioxide (CO2) Dry chemical Water spray jet
Unsuitable extinguishing media
:
High volume water jet
Specific hazards during firefighting
:
Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion products
:
Carbon dioxide (CO2) Carbon monoxide Smoke
Specific extinguishing methods
:
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Further information
:
Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. For safety reasons in case of fire, cans should be stored separately in closed containments. Use a water spray to cool fully closed containers.
Special protective equipment for firefighters
:
Wear self-contained breathing apparatus for firefighting if necessary. Personal precautions,
:
Use personal protective equipment.
SECTION 5. FIREFIGHTING MEASURES
SECTION 6. ACCIDENTAL RELEASE MEASURES
3 / 11
SAFETY DATA SHEET
Enforcer (R) BugMax (R) Fogger
Version 1.0
Print Date 05/09/2017
protective equipment and emergency procedures
Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Environmental precautions
:
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and materials for containment and cleaning up
:
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Sweep up or vacuum up spillage and collect in suitable container for disposal.
Advice on safe handling
:
Do not breathe vapours or spray mist. Avoid exposure - obtain special instructions before use. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Dispose of rinse water in accordance with local and national regulations. Persons susceptible to skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used. Always replace cap after use.
Conditions for safe storage
:
BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. No smoking. Keep in a dry, cool and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.
Materials to avoid
:
Oxidizing agents Do not store near acids. Store and keep away from bases and alkalies.
SECTION 7. HANDLING AND STORAGE
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
4 / 11