ENFORCER E-931-S50RRLQ User Manual

ENFORCER 50ft Large Reflective Beam Sensor
8 SECO-LARM U.S.A., Inc.
NOTICE
:
However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-
LARM reserves the right to
change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved.
This material may not be reproduced or copied, in whole or
in part, without the written permission of SECO-LARM.
WARRANTY:
This SECO-
LARM product is warranted against defects in material and workmanship while used in normal
service for one (1) year from the date of sale to the original customer. SECO-
LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-
LARM’s
option. In no event shall SECO-
LARM be liable for any special, collateral, incidental, or consequential personal or property
damage of any kind to the purchaser or anyone else.
SECO
-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA, 92606 Website: www.seco-larm.com
PITSW3
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
MiE-931-S50RRLQ_1312.docx
Troubleshooting:
Sensor does not detect the object.
Check the sensor’s alignment.
Readjust the sensor’s response time.
Alarm LED will not turn ON when the beam
is interrupted
Clean the sensor and reflector with a damp
(not wet) cloth.
Adjust the reflector and/or sensor for proper
alignment.
Alarm LED turns ON
when object is
detected, but there is no output
Check wiring between the sensor and local
alarm device.
Alarm LED is continuously ON
Check the sensor’s alignment.
Check for any objects between the sensor
and reflector that may be causing false
alarms.
Alarm output becomes erratic in bad
weather
Check the sensor’s alignment.
Readjust the sensor’s response time.
Frequent false alarms from leaves, birds,
or other objects
Readjust the sensor’s response time.
Change the sensor’s location.
This product is protected by the following patents: U.S. pat. no. D485774 Taiwan pat. no. 89463 China pat. no. ZL03311103.0 Other international patents are pending.
Note: Model numbers that end with “Q” or that have a round green “Q” sticker signify RoHS-compliant products.
E-931-S50RRLQ
50ft Large Reflective Beam Sensor
Manual
Up to 50ft (15m) sensing range
Weatherproof (IP55)
Beam status LED
12~250 VAC/VDC Operation
Form C relay rated 0.5A@120VAC
N.C. Tamper switch rated 0.5A@30VDC
Patented
ENFORCER 50ft Large Reflective Beam Sensor
2 SECO-LARM U.S.A., Inc.
Table of Contents:
Features
................................
.........................
2
Specifications ................................................. 2
Parts List ......................................................... 3
Dimensions ..................................................... 3
Overview ......................................................... 3
Choosing a Location ....................................... 4
Wiring Diagram ............................................... 4
Installation
................................
...................
5-6
Sample Installations ........................................6
Adjusting the Response Time..........................7
Adjusting the Alignment ...................................7
Fine-Tuning the Sensor ...................................7
Troubleshooting ...............................................8
Warranty ..........................................................8
Features:
Reflective beam provides reliable perimeter security, minimizing false alarms from falling
leaves, birds, etc.
Lensed optics
reinforces beam strength and provides excellent immunity to false alarms due to
rain, snow, mist, etc.
Weatherproof, sunlight-filtering case for indoor and outdoor use
Large reflective beam sensor
Long-range sensing: Up to 50ft (15m)
NO/NC Alarm output
Non-polarized power inputs, 12~250 VAC/VDC
Response time adjustable for nearly all situations
Includes hoods for sensor and reflector
Specifications:
Model E-931-S50RRLQ
Type 50’ Large Reflective Beam Sensor
Sensing range
50’ (15m)
Response time
50~700
ms (Programmable)
Current draw
100mA
LEDs
Red No beam signal, triggered
Yellow
Poor beam signal
Green Connected to power
Operating voltage
12~250 VAC/VDC
Alarm output
NO/NC Relay,
0.5
A@120VAC, min. 1s
Tamper output
N.C. Switch,
0.5A@30VDC
IP Rating
IP55
Alignment angle
Horizontal: ±90°,
Vertical: ±
Operating temperature
-13°~131° F (
-
25°~55° C)
Weight
Sensor
14.5-oz (
410
g) (with hood)
Reflector
8.8-
oz (
250
g) (with hood)
Material
PC Resin
ENFORCER 50ft Large Reflective Beam Sensor
SECO-LARM U.S.A., Inc. 7
Adjusting the Response Time:
The sensor’s response time can be adjusted by turning the response time adjustment knob.
Response time can be adjusted according to how quickly an object breaks the sensor beam. NOTE: A faster response time increases the chance of a false alarm. A slower response time increases the chance of missing a broken beam.
50ms 700ms
350ms
B
A C
Adjusting the Alignment:
The
sensor can be adjusted ±
5° vertically and ± 90° horizontally once the unit is mounted and
power is connected.
1. Remove the sensor cover and look into one of the alignment viewfinders (located between
the two lenses) at a 45° angle.
2. Adjust the horizontal and vertical angles of the lens until the reflector is clearly seen in the
viewfinder.
3. Replace the sensor cover.
Viewfinder
Horizontal adjustment
Vertical adjustment
Running (fast)
A B C
Walking
(normal) Slow Walking (slow)
Fine-Tuning the Sensor:
Once the sensor is mounted and aligned, the sensor can be
fine-tuned using the voltage output jack.
1. Set the range of a volt-ohm meter (VOM) to 1~10 VDC.
2. Insert the red (+) probe into the (+) terminal and the black
(–) probe into the (–) terminal.
3. Measure the voltage (see table).
4. Adjust the horizontal and vertical angles until the VOM
indicates the highest voltage. NOTE: Do not interrupt the beam while adjusting alignment.
Posi
tive (+) Nega
tive (–)
Voltage output
Alignment Quality
>
2.8 Best
2.1
~2.7V Good
1.2~2.0V
Fair
<1.1V Re-adjust