The following terms are used throughout this manual to bring attention to the presence of potential hazards
or to important information concerning the product.
DANGER
Indicates an imminent hazardous situation which,
if not avoided, will result in death, serious injury or
substantial property damage.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit in the manner intended by the manufacturer. If
you have questions, contact the manufacturer’s distributor at the
address or telephone number listed on the front of the manual.
2. Before servicing or cleaning the unit, switch o at service panel
and lock service panel to prevent power from being switched on
accidentally.
3. Installation work and electrical wiring must be done by a qualied person(s) in accordance with applicable codes and standards.
4. Follow the appliance manufacturer’s guidelines and safety
standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
5. This unit must be grounded.
How to use this manual
This installation manual does not contain any system design
documentation. System design documentation is available from
ENERVEX.
Accessories and variable frequency drives are not covered by this
manual. Please refer to these component’s individual manuals.
CAUTION
Indicates an imminent hazardous situation which,
if not avoided, may result in personal injury or
property damage.
3100153 RSHT009 - 016 2012-11-15
1. Product information
1.1 Function
Use exodraft model RSHT chimney fan is a chimney top mounted ventilator that is designed to provide
large ue gas volume capacities. It is intended for use with solid fuel but can also be used for nonsolid fuel provided a safety system is part of the installation (refer to the manual: “RS for Gas & Oil
Applications”). The use of the RSHT chimney fan is not restricted to any type of chimney, because the
fan creates a negative pressure (below atmospheric) in the chimney.
Typical uses are: Controlling the draft for a residential solid fuel red boiler, replace, stove, BBQ, or
pizza oven.
Function The RSHT chimney fan is designed to be able to withstand the high temperatures associated with
wood burning and to minimize the creosote buildup in the chimney ue and on the chimney fan.
The axial vane construction provides a self-cleaning eect. This product is developed to prevent draft
problems by creating a mechanical draft in venting systems and thereby also increasing the capacity
and eciency of a venting system. Though the chimney fan is not limited to such use, it is perfect for
use with replaces, barbecues, pizza ovens and wood stoves.
Code compliance Installations must conform to requirements of the authority having jurisdiction. Where required by
the authority having jurisdiction, the installation must also conform to the Standard for Draft Equipment and NFPA 211.
All electrical wiring must be in accordance with the requirements of authority having jurisdiction or,
in the absence of such requirements, with the National Electrical Code, NFPA70.
3
1.2 Shipping
The packing list (attached to one of the packages) clearly lists all items in the shipment and each package has a label
showing the contents. Check the list against all materials on the job site for completeness.
NOTE
All single phase fans are shipped with a capacitor and junction box connected via conduit. The
capacitor is located INSIDE the junction box. Please do not discard.
1.3 Warranty
exodraft products are warranted for a period of two (2) years following the date of invoice. Replacement or repair will be at exodraft’s discretion, provided factory inspection shows a defect in material or workmanship.
2-Year Factory Warranty
We promise the original user that we will replace or repair as we may elect, any part or parts of the new RSHT Chimney Fan
which are defective in material or workmanship without charge for parts and labor (not including labor for dismantling
and installation, freight, etc.) during the rst 2-years following the date of installation.
10-Year Corrosion Perforation Warranty
We promise the original user that we will replace or repair as we may elect, any part or parts of the RS Chimney Fan which
are perforated due to corrosion without charge for parts or labor (not including dismantling and installation, freight, etc.)
during the rst 10-years following the date of installation.
Complete warranty conditions are available at www.enervex.com or request a copy at:
info@enervex.com or at tel.: 1-800.255.2923.
A
3100153 RSHT009 - 016 2012-11-15
4
2. Specications
2.1 Dimensions and capacities
ModelRS009RS012RS014RS016
DischargeHorizontal
Fan TypeAxial Vane
Motor TypeTotally enclosed, Variable speed, Class F
VoltageV AC1x120
RPM1780178017801730
CFM0.0 Ps2755308301430
AmperageAmps0.851.253.504.50
Motor OutputHP0.110.130.340.47
kW0.080.100.250.35
Weightlbs25.633.541.947.2
kg11.615.219.021.4
DimensionsAin11.712.814.615.7
mm298325372400
B x Bin11.714.316.618.8
mm296364422478
Cin10.813.515.617.4
mm275344395441
Din3.03.33.93.9
mm7585100100
Ein8.711.013.015.0
mm220280330380
Temperature
Rating
Interm.1.330 °F/721 °C
Cont.930 °F/499 °C
C
D
E
B
1 Junction box
2 Conduit/cord
3 Motor
4 Motor housing
5 Motor plate
6 Bird screen
7 Base plate
8 Locking nut
9 Inlet
10 Axial vane
11 Hinges
12 Capacitor (inside junction box)
13 Cooling wheel
3100153 RSHT009 - 016 2012-11-15
2.2 Planning ahead
1. Observe proper combustion air requirements.
2. Provide a rm support system for the chimney fan.
3. Determine the type of system involved.
4. Observe proper safety measures are taken to assure safe use of the wood burning appliances.
Combustion air requirements
Provisions for combustion air must be in accordance with applicable local codes.
Adequate fresh air must be provided for combustion; otherwise, improper operation and inadequate
venting of deadly ue gases may result.
Support system Prior to installation of the chimney fan, it must be assured the chimney cansafely carry the weight of
the chimney fan.
A steel chimney should be well supported at the roof penetration point. If the chimney extends more
than 20’ above the roof, the chimney and the fan should be secured by wires attached on the chimney and on the roof at 2 to 3 dierent points.
Brick chimneys usually do not need any kind of support to carry the weight of the chimney fan.
System type Fireplaces and wood stoves used in residences normally operate in a relatively stable environment,
where no major pressure uctuations occur. However, speed adjustments and adjustment of airintakes are required as the wood burns and new wood is added to the re.
Fireplaces used in restaurants are exposed to major pressure changes. Doors open, doors close,
kitchen exhaust fans pull out air, etc. Spillage can easily occur.
Wood-red pizza ovens and barbecues are normally installed in restaurant kitchens where kitchen exhaust fans are operating. Consequently, the operator should pay attention to the fact that even with a
well balanced exhaust system, it will be necessary to adjust the fan speed in order to avoid spillage.