This symbol shows that ENERVEX IPVB Inline Power Venters for solid fuel applications are listed under ETL File no. 514733.
Symbol Legend
The following terms are used throughout this manual to bring
attention to the presence of potential hazards, or to important
information concerning the product.
DANGER: Indicates an imminent hazardous
situation which, if not avoided, will result in death,
serious injury or substantial property damage.
WARNING: Indicates an imminent hazardous
situation which, if not avoided, may result in
personal injury or property damage.
DANGER: Indicates an imminent electrical shock
hazard which, if not avoided, will result in death,
serious injury or substantial property damage.
How to use this manual
This installation manual does not contain any system design
documentation. System design documentation is available
from any authorized ENERVEX representative. Accessories,
fans, and variable frequency drives are not covered by
this manual. Please refer to these component’s individual
manuals.
TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address or telephone number listed on the front of the
manual.
2. Before servicing or cleaning the unit, switch off at service
panel and lock service panel to prevent power from being
switched on accidentally.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with applicable codes
and standards.
4. Follow the appliance manufacturer’s guidelines and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. This unit must be grounded.
2
Content
1. GENERAL INFORMATION
1.1 Function ............................................................................................4
The IPVB Power Venter is intended for use as a true in-line
draft inducer. It can be installed in-line in the vertical or
horizontal section of a chimney or stack. It is specifically
designed for applications where reliable and efficient
operation, low noise level, low energy consumption, variable
speed and compact design are critical.
The IPVB is for use with condensing and non-condensing
appliances at flue gas temperatures of 575°F (302°C) for
continuous operation.
Typical uses are mechanical venting of gas-fired or oil-fired
boilers and water heaters. The IPVB is for indoor or outdoor
installation where ambient temperatures are in the range of
-40°F to 122°F (-40°C to 50°C).
The IPVB Power Venter is an efficient, high-temperature
ventilator with backward-inclined impeller. The ventilator
housing is made of stainless steel and equipped with an
energy-efficient, totally enclosed, variable speed motor, which
is mounted outside the air stream. The design is a Type B,
Spark Resistant Construction. The motor and impeller is a
complete assembly (drive unit) that can be removed from the
fan housing without removing the fan from the stack system.
The stack connections are of the flanged connection type
and fit most commercial pre-fabricated chimney systems.
The fan is typically installed hung from ceiling mounting
brackets to support the weight. The IPVB model is approved
for temperatures up to 575°F (302°C). The IPVB is a
component in the ENERVEX CASITM, Chimney Automation
System.
The housing is made of 316L stainless steel. The impeller
is of the backward inclined type made of cast aluminum.
Commercial grade, totally enclosed (TEFC), variable speed,
Class A insulated motor with sealed and permanently
lubricated bearings. Thermal overload protection.
The IPVB Power Venter should only be used with appliances
operating on Natural Gas, LP-Gas/Butane or fuel oil (#2
through #6). It should never be used with incinerators,
incinerating toilets or solid-fuel burning equipment. The
temperature of the flue gases going through the Power
Venter should not exceed 575°F (302°C).
4
1.2 COMPONENTS
B
A
C
E
D
F
AIR
FLOW
A. Inlet
B. Outlet
C. Motor
D. Housing
E. Impeller
F. Motor Mounting Plate
3002600 08.17
Fig 1
1.3 SHIPPING
The IPVB is shipped on a pallet covered by a cardboard box.
STANDARD PACKING LIST
The IPVB is shipped with a junction box and drain installation
kit. If other components are shipped, these will appear as
separate items on the shipping packing list.
NOTE:
All single phase fans ae shipped with a capacitor and junction
box connected via conduit. The capacitor is located INSIDE
the junction box. Please do not discard.
SHIPPING WEIGHT*
ModelLbs
300100
350120
400150
500200
*Weight includes the shipping pallet
1.4 WARRANTY
ENERVEX products are warranted for a period of two (2)
years following the date of invoice. Replacement or repair
will be at ENERVEX’s discretion, provided factory inspection
shows a defect in material or workmanship.
Complete warranty conditions are available from ENERVEX.
5
3002600 08.17
0.0
1.0
0.5
2.0
1.5
3.0
2.5
4.0
3.5
5.0
4.5
P
(inW.C.)
2. SPECIFICATIONS
2.1 DIMENSIONS & CAPACITIES
Specifications
ModelIPVB 300 IPVB 350 IPVB 400 IPVB 500
Fa n TypeCentrifugal Impeller (B-wheel)
Motor TypeTEFC
VoltageVAC1 x 1203 x 200-240 / 3 x 440-480
AmperageAmps5.82.6 / 1.55.5 / 2.97.8 4.1
Motor
Max. RPM160 0174 0
Duct Connectionin12141620
(Nominal)mm300350400500
Dimensions
Weight
Max. Temperature575°F (302°C) Continous
Removal of drive unit
Output HP0.51.02.03.0
kW0.350.751.52.2
in19.322.426.429.5
A
mm49056967174 9
in13.014. 617.021.3
B
mm330371432541
in13.915.517. 822.1
C
mm353394452561
in12.114.016. 020
D
mm306356406508
in11.112.714.616.2
E
mm282322370411
in6.97. 88.911.1
F
mm175198226282
in15.815 .816.22 0 .1
G
mm401401411511j j
in21.624.626.330.0
H
mm549625668762
in2.52.52.62.7
J
mm64646669
in47.151.256.866.9
L
mm119 91300144 3169 9
W
in22.225.329.232.4
mm56464374 2823
lbs759412818 2
kg3442.55882.5
Fan without drive unit
Capacity
t
IPVB 500
IPVB 300
0 1000 2000 5000
NOTE:
The capacity data above is tested in accordance with ISO
Standard 5801-Industial Fans Performance Testing Using
Standardized Airways.
6
IPVB 350
IPVB 400
30004000
Volume (cfm)
6000