Congratulations on your purchase of an ENERGY KING solid fuel heating appliance!
Your ENERGY KING Wood/Coal Furnace is designed for a lifetime of durable, reliable
performance and easy operation. This manual describes the installation, operation and
maintenance of your ENERGY KING Wood/Coal Furnace.
Before installing your ENERGY KING Wood/Coal Furnace,
please read and be sure you understand the entire owner’s
manual and safety instructions.
Refer to markings on the appliance for additional
instructions.
ENERGY KING Wood/Coal Furnace has been designed to use independently or as an
add-on to an existing central heating system. The installation of any furnace is not a do-it-yourself project. To ensure the ENERGY KING Wood/Coal Furnace will operate safely
and efficiently, the installation must be performed by a qualified installer with specific knowledge of central heating systems.
With proper installation and maintenance, your ENERGY KING Wood/Coal Furnace will
give you years of trouble free service.
Thank you for choosing the ENERGY KING Wood/Coal Furnace.
We are constantly improving and updating our products in order to provide the highest quality and value
possible. RJM Manufacturing, Inc., the manufacturer of this product, reserves the right to alter its products,
their specifications and/or prices without notice.
ENERGY KING is a registered trademark of RJM Manufacturing, Inc.
Read this entire manual before installing,
operating or maintaining this product.
Proper installation of this heating
appliance is crucial for safe and efficient
operation. Save these instructions for later
use.
▲
This heating appliance must be
installed in accordance with local,
state, and national codes and
regulations. Contact your local building
or fire officials about installation
restrictions and inspection requirements in
your area.
▲
Do not connect this heating appliance
to a chimney flue serving any other
appliance.
Failure to follow these safety instructions may result
in property damage, bodily injury or even death.
▲
The fuel loading and ash removal doors
must be closed tightly during operation. All
seals must be maintained in good
condition.
▲
This Furnace is designed to burn air-dried
wood, or anthracite or bituminous coal
only. Burning of any other type of fuel will void your ENERGY KING warranty.
▲
Do not burn: Treated wood, colored
paper, garbage, cardboard, solvents, or
trash—burning these may result in toxic
fumes, or produce soot and large flakes of
char or fly ash. Burning treated wood,
colored paper, garbage, cardboard,
solvents or trash can be dangerous and
will void your ENERGY KING warranty.
▲
Do not install this heating appliance in
a mobile or manufactured home—this
can be dangerous and will void your
warranty. This heating appliance has not
been tested to meet the strict
requirements necessary for installation
into a mobile or manufactured home.
▲
Install in an area with adequate air for
combustion and ventilation. The use of
outside air may be required for safe
operation of this heating appliance.
Contact your local building or fire officials
about combustion air requirements in your
area.
▲
All minimum clearances to combustible
materials must be strictly followed.
▲
This heating appliance must be installed
on a non-combustible floor or 3/8-inch
thick fireproof millboard or equivalent. See
Installation for further instructions.
▲
Disconnect all power to the heating
appliance at the breaker box or service
panel before performing routine
maintenance and service. Allow the
heating appliance to cool before servicing.
▲
Do not place clothing or other flammable
materials on this heating appliance or
within marked clearances to combustibles.
▲
Do not use, store, or dispose of flammable
liquids near the heating appliance.
▲
DANGER – Risk of Fire or Explosion:
Do not burn garbage, gasoline, naphtha,
drain or engine oil, or other flammable
liquids or inappropriate materials in this
heating appliance.
▲
Do not use chemicals or fluids, such as
gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fluid, or similar
liquids to start or freshen up a fire in this
heating appliance.
▲
Establish a routine for the storage of fuel,
care of the heating appliance and firing
techniques.
▲
CAUTION – Hot Surfaces: Keep children
away! Do not touch heating appliance
during operation.
▲
Use caution when opening fuel loading
door. Opening fuel loading door rapidly
can cause smoke or flame to flash out the
door. See Operation for further
instructions.
Rev 05/05/11 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. i
Page 6
Safety Instructions
▲
Dispose of ashes with care. Ashes should
be placed in a metal container with a tight
fitting metal lid. The closed container of
ashes should be placed on a
noncombustible floor or on the ground,
well away from all combustible materials,
pending final disposal.
▲
A working smoke detector must be
installed in the same room as this product.
For additional safety, RJM Manufacturing,
Inc. also recommends installing working
smoke detectors and a listed carbon
monoxide warning device in the living
areas of the home.
All coal contains small amounts of
dangerous elements. Therefore it is
essential that all coal ash be disposed of
in municipally designated areas.
The National Fire Protection Association has information available on the safe use of solid-fuel
heating appliances. You can contact the NFPA at: National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02169-7471 or www.nfpa.org.
Failure to follow these safety instructions may result
in property damage, bodily injury or even death.
▲
Always keep a working fire extinguisher
on hand in case of fire.
Rev 05/05/11 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. ii
Page 7
Table of Contents
SAFETY INSTRUCTIONS ................................................................................................................................................ i
TABLE OF CONTENTS ................................................................................................................................................... 1
As Primary Furnace .......................................................................................................................................................... 9
As Add-On Furnace: ....................................................................................................................................................... 10
Barometric Draft Control ........................................................................................................................................ 21
Starting a Wood Fire ................................................................................................................................................ 25
Starting a Coal Fire ................................................................................................................................................. 27
APPENDIX C: PARTS LIST ........................................................................................................................................ 43
APPENDIX D: PURCHASE & SERVICE RECORD ................................................................................................ 47
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 1
Page 8
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 2
Page 9
Specifications
Model Number 360EK/365EK 480EK
Dimensions (H x W x D) 48″ x 26″ x 53″ 51.5″ x 26″ x 60″
Leg Height 3.5″ 3.5″
Shipping Weight (Approx.) 650 lbs. 725 lbs.
Heating Capacity - BTU’s (Approx) 125,000 BTU 160,000 BTU
Heating Capacity – Sq Ft (Approx) 1,500 sq. ft. 2,000 sq. ft.
Burn chamber Volume 6.3 cu. ft. 9 cu. ft.
Flue Size (Rear Vent) 6″ 6″
Flue Collar Height (to top of flue) 45″ 48.25″
Log Length 21″ 26″
Cast Iron Fuel Loading Door Size (H x W) 15.5″ x 13.5″ 15.5″ x 13.5″
Cast Iron Ash Removal Door Size (H x W) 7.25″ x 11.5″ 7.25″ x 11.5″
Sliding Smoke Baffle Standard Standard
Insulated Cabinet Standard Standard
Wall Thermostat Standard Standard
Draft Controls Manual or Auto (Choice) Auto or Forced (Choice)
Pre-wired Electrical Components Standard Standard
Electrical Requirements
Cast Iron Hearth Plates
(Front & Rear)
115 Volts, 60HZ,
1 Phase, 15 Amps Circuit
Standard Standard
115 Volts, 60HZ,
1 Phase, 15 Amps Circuit
Removable Ash Pan Standard Standard
Cast Iron Stationary (Wood) Grates Standard Standard
Cast Iron Shaker Grates Optional Optional
Domestic Hot Water Tube Optional Optional
*The heating capacity specifications are provided as guidelines only and in no way guarantee the output or
capacity of the units. The actual BTU output depends on the type of fuel being burned and its condition, the
thermostat setting, the draft adjustments and the chimney into which the unit is installed.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 3
Page 10
Component Description
1. 6″ Chimney Outlet. Venting must be
provided using a lined masonry chimney or a
listed UL103 type HT chimney. The chimney
exhausts smoke and flue gases that are a
natural result of combustion and provides
“draft” to the Furnace. Draft is the force that
moves air from the burn chamber up through
the chimney. See Venting for further
instructions.
2. Sliding Smoke Baffle. When open, the
sliding smoke baffle allows smoke and flue
gases to flow into the chimney connector
without restriction. When closed, smoke and
Figure 1: Components (Cutaway View)
flue gases are diverted around the sliding
smoke baffle, creating a longer path for the
heated air and allowing your furnace to
extract the maximum amount of heat from
the fire.
3. Plenum Opening. Allows you to connect the
Furnace into your home’s warm-air supply
duct. ENERGY KING 360EK/365EK Furnace
has a plenum opening of 18 inches by 18
inches. ENERGY KING 480EK Furnace has
a plenum opening of 20 inches by 20 inches.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 4
Page 11
Component Description
4. Cast Iron Doors. Heavy cast iron fuel
loading and ash removal doors are secured
to the Furnace using door pins (4 included).
The door gaskets provide an airtight seal and
should be inspected regularly to ensure that
they are in good condition at all times. The
gasket must be replaced if it becomes
damaged or worn. Do not operate the
Furnace with the fuel loading or ash removal
doors open.
5. Cast Iron Hearth Plates. Cast with the
words “Wood” and “Coal” on opposite sides,
these plates help to ensure the precise
amount of combustion air required to
promote the most efficient combustion for
either fuel. ENERGY KING Wood/Coal
Furnaces use two cast iron hearth plates—
one at the front of the burn chamber, and
one at the rear. (2 included).
Cast Iron Stationary (Wood) Grates. (Not
pictured). This is where you build your wood
fire. If you selected the Shaker Grate option,
the Wood Grates will have been replaced with
Shaker Grates at the factory.
6. Cast Iron Shaker Grates (Optional). This is
where you build your wood or coal fire. The
handle to control the Shaker Grates is
located at the front of the Furnace, on the left
side of the ash removal door.
7. Firebrick. (9″ x 4-1/2″ x 1-1/4″) 2000-degree,
heat retentive firebrick protects the sides of
the Furnace’s burn chamber. ENERGY KING
360EK/365EK Furnace uses 10 firebricks (5
on each side), while ENERGY KING 480EK
Furnace uses 12 firebricks (6 on each side).
Ash Removal Pan. (Not pictured) Designed for
easy cleanup of fine ash accumulation. Do not
operate the Furnace with the ash removal door
open; keep it closed except to remove ashes.
The ash removal door gasket provides an
airtight seal and should be inspected to ensure
that it is in good condition at all times. The
gasket must be replaced if it becomes
damaged or worn.
8. Circulation Blower. The three-speed
circulation blower, operated by the fan/limit
control, forces air on all sides of the burn
chamber, then into the home's duct system.
The blower can be manually adjusted to run
faster or slower to correspond to the amount
of heat being produced.
Rev 03/12/14 ENERGY KING
9. Filter Box (optional). Provides air filtration
for your cold-air return system. A noncombustible filter is required when using the
optional filter box.
10. Control Box. Controls the Furnace’s
electrical system. The control box is prewired for your preferred draft system.
Combustion Fan. (Not pictured) If you
selected Forced Air Draft, this fan will supply air
for combustion by forcing air into the burn
chamber when your wall thermostat calls for
heat.
11. 24-V Damper Control Motor. If you
selected Automatic Draft, this motor will
supply combustion air to the burn chamber
by automatically opening the draft damper
door when your wall thermostat calls for
heat.
Draft Dial. (Not pictured) If you selected
Manual Draft, this spin dial will allow you to
regulate the amount of combustion air being
pulled into the burn chamber.
24-V Wall Thermostat. (Not pictured) Tells
your Furnace when your home has cooled
below your preferred temperature. Your
automatic or forced air draft system is
controlled primarily by your wall thermostat.
12. Fan/Limit Control. This control
automatically starts and stops the
circulation blower. It also features a limit
switch which will cut power to the damper
control motor or combustion fan if the
temperature exceeds the set limit, while the
circulation blower continues to run to cool
the furnace.
13. Insulated Cabinet. The almond-colored
steel cabinet panels (sides and top) restrain
the foil-backed insulation, allowing
maximum heat from the Furnace to be
circulated through the home’s warm-air
supply duct system.
14. Legs. Raise the Furnace off the floor to
prevent the accumulation of moisture
between the floor and the bottom of the
Furnace.
Domestic Hot Water Tube (Optional).
(Not pictured) For heating domestic water.
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 5
Page 12
Preinstallation Considerations
This Furnace is intended for use in residential buildings. Do not install this heating appliance in a
mobile or manufactured home—this can be dangerous and will void your warranty. This heating
appliance has not been tested to meet the strict requirements necessary for installation into a
mobile or manufactured home.
Always check with local authorities and obtain the necessary permits prior to installing this heating
appliance. This heating appliance must be installed in accordance with local, state and national
codes and regulations.
Before the position of the Furnace can be decided, a few questions should be considered.
1. Will this Furnace be used as a primary
(central) furnace, or will it be installed as an
add-on to your existing central heating
system?
2. Can the Furnace be vented properly?
a. Is your chimney appropriate for this
application? This Furnace requires
installation into a UL103 Type HT all-fuel
chimney. Do not connect this unit to a
chimney flue serving any other
appliance.
b. Has your chimney been inspected? For
your safety, it is important your chimney
be clean and free from defect or damage
prior to installing your Furnace.
3. This Furnace may require an outside air
source for combustion air. Will this be
easily accessed in your desired location?
4. Are there any local, state or national codes
or regulations governing the use and
placement of the Furnace?
Finally, do you have a reliable, consistent source of fuel for your Furnace? Please see Fuel Requirements for further information on fuel supply.
5. Can the Furnace be installed safely?
a. The Furnace should not be installed in a
location where it could come into contact
with curtains, drapes, walls, carpeting, or
other combustible surfaces, and must
not be installed in a sleeping room.
b. Will your desired location require floor
protection?
c. The clearances specified in this manual
are minimum clearances. Any reduction
must be approved by the regulatory
authority and is not recommended by
RJM Manufacturing, Inc.
6. How close is the electrical source? The
power source must conform to the
requirements shown in Specifications.
7. Will the Furnace be easily accessible for
cleaning, refueling, maintenance, and
repair?
8. Are there any structural reasons why the
Furnace cannot be placed where you
want?
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 6
Page 13
Fuel Requirements
BURN AIR-DRIED WOOD, OR ANTHRACITE OR BITUMINOUS COAL ONLY
Risk of Fire: Do not store fuel or other combustible
material within the marked installation clearances.
It is important to use fuel that is clean, dry and consistent. Solid-fuel Furnaces, such as your
ENERGY KING Wood/Coal Furnace, naturally produce ash as a byproduct of the burning process.
Even with the ENERGY KING Furnace’s efficient design, your Furnace will still produce some
amount of ash which will need to be cleaned periodically. The type and quality of fuel you burn
affects the amount of ash produced and the performance of your Furnace. To assist you in
determining which fuel to use, here are some guidelines to consider:
Burning wood for heat is as old as civilization itself. More than any other major fuel, wood provides
us with energy independence – an easily available, locally produced and renewable source of heat
on which we can rely.
This Furnace has been tested for operation
with air-dried wood.
Wood should be seasoned (dried) for at
least 12 months before burning. Properly
seasoned wood should have about 20% 30% moisture content. To properly season
wood, split the logs as soon as possible
and loosely stack them in a dry spot for at
least 12 months.
You should not burn wet or green wood in
your Furnace. Burning wet or green wood
in your Furnace will not only reduce the
efficiency of your appliance, but also
increases the risk of dangerous creosote
build-up in your appliance and chimney.
Softwoods, such as pine and fir, are easily
ignited and burn rapidly with hot flames.
With softwoods, you will spend more time
reloading your Furnace, and will have much
more difficulty achieving an overnight burn.
For a longer lasting fire, it is best to use
more dense hardwoods.
Ideally, you should burn a mixture of
hardwoods and softwoods, using the hotter,
faster burning softwoods to start your fire,
and the denser hardwoods to maintain a
longer-lasting fire.
WOOD
With this in mind, choosing the kind of
firewood that is best for you depends on
what is available in your area. If hardwoods
are unavailable in your area, you can
control the burn rate by using larger pieces
of wood and by adjusting your draft
controls.
DO NOT BURN: Treated wood, colored
paper, garbage, cardboard, solvents, or
trash—burning these may result in toxic
fumes, or produce soot and large flakes of
char or fly ash. Burning treated wood,
colored paper, garbage, cardboard,
solvents or trash can be dangerous and will
void your ENERGY KING warranty.
DANGER – Risk of Fire or Explosion: Do
not burn garbage, gasoline, naphtha, drain
or engine oil, or other flammable liquids or
inappropriate materials in this Furnace.
Storage
Store all fuel in a dry location away from
the elements. Never burn wet or green
wood.
Do not store fuel within the Furnace
installation clearances or within the space
required for refueling, ash removal and
other routine maintenance operations.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 7
Page 14
Fuel Requirements
BURN AIR-DRIED WOOD, OR ANTHRACITE OR BITUMINOUS COAL ONLY
Risk of Fire: Do not store fuel or other combustible
material within the marked installation clearances.
One of the world’s most widely-used fuel sources, coal can provide the energy independence and
low fuel prices sought by owners of solid-fuel heating appliances.
This Furnace has been tested for operation
with anthracite (hard) or bituminous (soft)
coal.
Anthracite: Also known as Hard Coal,
anthracite is a hard, lustrous coal with a
high carbon content that burns with a clean
blue, nearly smokeless, flame.
Bituminous: Also known as Soft Coal,
bituminous coal is a soft type of coal that
has a high sulfur content and burns with a
yellow, smoky flame.
Bituminous coal tends to contain more
impurities and sulfur than anthracite coal,
which may decrease the expected lifespan
your ENERGY KING solid-fuel heating
appliance and its components. Only burn
high-grade bituminous coal.
Coal Size: Your ENERGY KING
Wood/Coal Furnace is designed to use coal
that is Nut size or larger.
COAL
DO NOT BURN: Treated wood, colored
paper, garbage, cardboard, solvents, or
trash—burning these may result in toxic
fumes, or produce soot and large flakes of
char or fly ash. Burning treated wood,
colored paper, garbage, cardboard,
solvents or trash can be dangerous and will
void your ENERGY KING warranty.
DANGER – Risk of Fire or Explosion: Do
not burn garbage, gasoline, naphtha, drain
or engine oil, or other flammable liquids or
inappropriate materials in this Furnace.
Storage
Store all fuel in a dry location away from
the elements. Never burn wet coal.
Do not store fuel within the Furnace
installation clearances or within the space
required for refueling, ash removal and
other routine maintenance operations.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 8
Page 15
Installation
Risk of Fire:
Do not operate with flue draft exceeding .06 in. (14.95 Pa)
water column.
Do not operate with fuel loading or ash removal doors open.
Do not store fuel or other combustible material within marked
installation clearances.
Inspect and clean flues and chimney regularly.
The installation of any solid-fuel heating appliance is not a do-it-yourself project. The
ENERGY KING Wood/Coal Furnace should be installed by a qualified installer with specific
knowledge of central heating systems. Check with your fire department and building inspector for
local, state, and national codes and regulations regarding installation.
Solid-fuel heating appliance related fires are caused almost exclusively by installation, operation, or
maintenance errors. A smoke detector in “working” condition must
ENERGY KING solid-fuel heating appliance installation—this is the most inexpensive insurance you
can buy! For additional safety, RJM Manufacturing, Inc. recommends installing working smoke
detectors and a listed carbon monoxide warning device in the living areas of the home.
The ENERGY KING Wood/Coal Furnace is designed to be used in conjunction with a listed gas- or
oil-fired furnace, or as a central Furnace.
Placement
Do not connect the ENERGY KING heating appliance
to any chimney flue serving any other appliance.
General Requirements
be a part of every
Floor Protection
Floor protection must be provided because
of possible spillage of ashes and burning
fuel. The ENERGY KING Wood/Coal
Furnace must be installed on a noncombustible floor or 3/8-inch thick fireproof
millboard or equivalent.
The non-combustible material must be
placed underneath the furnace, and must
extend at least 18 inches on all sides of the
Furnace, and at least 8 inches on either
side of the fuel loading and ash removal
doors.
Additionally, the non-combustible material
must extend at least 18 inches on either
side of the chimney connector.
Consult your local ENERGY KING dealer
for possible sources of non-combustible
floor protection material acceptable for use
with your ENERGY KING Wood/Coal
Furnace.
As Primary Furnace
Locate the ENERGY KING Wood/Coal
Furnace as close to the new or existing
chimney as possible and as central to the
heat distribution system as practical.
Additionally, the ENERGY KING
Wood/Coal Furnace should be placed so
that you can easily complete operation and
maintenance procedures.
Strictly adhere to all requirements
pertaining to clearances to combustibles,
combustion air, venting system, draft
control, and thermostat installation.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 9
Page 16
Installation
As Add-On Furnace:
The ENERGY KING Wood/Coal Furnace is
designed to be used in conjunction with a
listed gas- or oil-fired furnace, but not all
furnaces will accept an add-on application.
Some small furnaces, and especially
counter-flow or down-flow furnaces, may not
be used in an add-on installation.
The CFM (cubic feet per minute) capability
between the blower on the existing furnace
and the add-on furnace must be compatible.
If all of these conditions are met, then the
combined static pressure may not exceed
that established by the existing furnace.
Before installing your ENERGY KING
Wood/Coal Furnace, consult your
ENERGY KING dealer or heating contractor
and your local, state and national building
codes and regulations to determine if your
existing central heating system is compatible
with your ENERGY KING Wood/Coal
Furnace.
Clearances to Combustibles:
Sides: The ENERGY KING must have
clearances of 18 inches from the sidewall of
the ENERGY KING wood/coal Furnace to
combustibles.
Front: Leave a minimum clearance of 48
inches in front of your ENERGY KING
wood/coal Furnace. This is for safe, easy
loading and cleaning of your ENERGY KING.
Rear: The minimum clearance from the rear of
the ENERGY KING wood/coal Furnace to
combustibles is 28 inches
Top: The minimum clearance from the top of
the ENERGY KING Wood/Coal Furnace to
combustibles is 18 inches.
Stovepipe: Stovepipe must
have a minimum
of 18 inches from the rear to combustibles,
and a minimum of 20 inches from the sides to
combustibles.
Additionally, when using your ENERGY KING
wood/coal Furnace as an add-on, a 6-inch
minimum clearance is required between the
ENERGY KING Furnace and your existing
furnace.
Once it has been determined that your
existing furnace will accept an add-on
installation, RJM Manufacturing, Inc.
recommends a parallel installation, with a
direct (ducted) feed of return air to the
ENERGY KING Wood/Coal Furnace.
Install two backflow dampers to ensure that
when either furnace is operating
independently, hot air will not flow back
through the other furnace.
When using your ENERGY KING Wood/Coal
Furnace as an add-on, locate the
ENERGY KING as close to the new or
existing chimney as possible and as close to
your existing furnace as practical. However,
a minimum clearance of 6-inches is required
between your existing furnace and your
ENERGY KING Wood/Coal Furnace.
Figure 2: Clearances to Combustibles
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 10
Page 17
Installation
Assembling Your ENERGY KING Wood/Coal Furnace
The entire installation should be planned before putting the furnace in place to ensure compliance
with all the requirements outlined in the owner’s manual and any applicable markings on the
appliance.
Your new ENERGY KING Wood/Coal Furnace will have been shipped on a pallet with several
boxed components that will need to be assembled prior to installation. Please see Components for
a list of everything that was shipped along with your ENERGY KING Wood/Coal Furnace.
Once your furnace is placed in your desired location:
1. Remove the protective plastic coating from
the outer cabinet of the Furnace before
assembling.
2. Cast Iron Hearth Plates. Position front and
rear cast iron hearth plates in the burn
chamber. Your primary type of fuel (wood
or coal) will determine how to position the
hearth plates. The words “Wood” and
“Coal” are cast into the end plate on
opposite sides. The purpose of proper
location is to introduce the precise amount
of combustion air into the burn chamber to
promote the most efficient combustion for
either fuel.
a. If you are going to burn wood, position
the hearth plates with the word “Wood”
facing out, not into the burn chamber.
b. If you plan to primarily burn coal, position
the hearth plates with the word “Coal”
facing out.
3. Firebrick. The firebrick in your
ENERGY KING Furnace will have been
installed at the factory; however, they may
have shifted during shipment. If
adjustments are needed, position the
firebrick by standing up on end on the left
and right sides of the burn chamber.
The ENERGY KING 360EK/365EK
Wood/Coal Furnace uses 10 firebricks (5
on each side), while the ENERGY KING
480EK Wood/Coal Furnace uses 12
firebricks (6 on each side).
4. Cast Iron Doors. Mount the fuel loading
door and ash removal door on the front of
the Furnace and secure with the enclosed
door pins.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 11
Page 18
Installation
5. Control Box.
a. Remove the control box cover. See Figure 3: Control Box for Automatic Draft, Figure 4: Control
Box for Forced Air Draft, or Figure 5: Control Box for Manual Draft.
b. Mount the pre-wired control box on the lower left side of the Furnace using the screws
provided.
Figure 3: Control Box for Automatic Draft
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 12
Page 19
Installation
Figure 4: Control Box for Forced Air Draft
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 13
Page 20
Installation
Figure 5: Control Box for Manual Draft
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 14
Page 21
Installation
6. Draft System.
a. Insert the conduit leading from your
chosen draft system into the control box
and tighten screw to secure.
b. For Automatic Draft. Mount the
automatic draft tube with the pre-wired
damper control motor to the draft
opening located next to the ash removal
door on the lower left front of the
Furnace, and secure using the bolts
found on the draft opening.
Figure 6: Automatic Draft Tube
with Damper Control Motor
c. For Forced Air Draft. Mount the prewired
forced air draft blower to the draft
opening located next to the ash removal
door on the lower left front of the
Furnace, and secure using the bolts
found on the draft opening.
Figure 7: Forced Air Draft Blower
d. For Manual Draft. Mount the manual
draft tube with attached spin dial to the
draft opening located next to the ash
removal door on the lower left front of
the Furnace and secure using the bolts
found on the draft opening.
Figure 8: Manual Draft Tube with Spin Dial
7. Fan/Limit Control.
a. Remove the cover of the fan/limit
control.
b. Mount the fan/limit control to the side of
the furnace directly above the control
box. Attach into the pre-punched holes
using the screws provided.
Figure 9: Fan/Limit Control, Mounted
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 15
Page 22
Installation
c. Set Pointers. Hold dial securely with one
hand and move the pointers with the
other hand. Do not force the pointers past
any stops on the dial even though the dial
may be graduated beyond the stops.
i. Limit. Verify that the right hand
pointer is set at 200-degrees F. This
is the temperature at which contacts
should open to prevent your Furnace
from overheating. Never set the Limit
pointer higher than 200-degrees F, as
recommended by the Fan/Limit
Control manufacturer.
ii. Fan. Move the “Fan On” pointer so
that its straight edge indicates the
temperature at which the fan contacts
should close to start the blower. Move
the “Fan Off” pointer so that its
straight edge indicates the
temperature at which the fan contacts
should open to stop the blower.
Recommended “Fan On” setting is
145-degrees F. Recommended “Fan
Off” setting is 90-degrees F.
Figure 10: Fan/limit Control Settings
Recommended “Fan Off” setting is 90 º F.
Recommended “Fan On” setting is 145º F.
8. Circulation Blower.
a. Mount circulation blower on rear of
b. If you selected the optional Filter Box kit,
furnace using the four bolts supplied.
proceed to step 9. Otherwise, attach the
conduit to Control Box and connect wire
ends as detailed in Appendix A: Wiring
Diagrams. Do not connect power to
your ENERGY KING Wood/Coal
Furnace until the installation is
complete.
9. Cold Air Return & Optional Filter Box.
a. Determine whether your cold air return
will enter on the left or right side of the
furnace.
b. Assemble the optional filter box per
Appendix B: Filter Box Assembly
Schematic.
c. Feed the conduit from your circulation
blower through the hole located on the
top of the filter box. Attach the conduit to
Control box and connect wire ends as
detailed in Appendix A: Wiring Diagrams.
Do not connect power to your
ENERGY KING Wood/Coal Furnace
until the installation is complete.
10. Domestic Hot Water Tube (Optional).
a. Your optional domestic hot water tube
may have been installed at the factory. If
so, your plumber can connect your
domestic hot water supply per the
installation instructions provided by the
hot water tube manufacturer.
b. If your optional domestic hot water tube
was not factory-installed, please follow
the installation instructions provided by
the hot water tube manufacturer.
11. Wiring. Do not connect power to your
ENERGY KING Wood/Coal Furnace until
the installation is complete.
Once you’ve completed the installation of
your ENERGY KING Wood/Coal Furnace,
you may connect your 110V power supply
to the left side of the control box. Wiring is
based on draft choice. Please see
Appendix A: Wiring Diagrams.
Risk of electric shock.
Disconnect power at the service
panel or breaker box before
servicing the ENERGY KING
Wood/Coal Furnace.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 16
Page 23
Installation
Combustion Air Requirements
The ENERGY KING Furnace must have a minimum supply
All fuel-burning appliances must have air (oxygen) for proper combustion. The incomplete
combustion that takes place when a solid-fuel appliance is “air-starved” causes carbon monoxide
(CO) production in quantities that can be dangerous inside a building. Combustion air from outside
may need to be brought in to prevent “air starvation”. Although an outside air source is strongly
recommended for all installations, it may be necessary if:
The Furnace does not draw steadily, smells, experiences smoke roll-out, burns
poorly, or back drafts whether or not there is combustion present.
Any of the above symptoms are alleviated by opening a window slightly on a calm
day.
The house is equipped with a well-sealed vapor barrier and tight fitting windows
and/or has any powered devices which exhaust house air, such as clothes dryers.
A ventilation system is installed in the house.
Consult a qualified Furnace installer to analyze whether the air supply in your installation
environment is adequate.
Failure to provide adequate combustion air can
lead to increased carbon monoxide production
and increased emissions of combustion gases
into the building, which may cause death or
serious injury.
of 70 cubic feet of air per minute.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 17
Page 24
Installation
Venting System
Failure to provide correct chimney venting can lead to
increased carbon monoxide production and increased
emissions of combustion gases into the building, which may
cause death or serious injury.
Do not connect ENERGY KING heating appliance to any
chimney flue servicing any other appliance.
Risk of Fire: Inspect and clean flues and chimney regularly.
Risk of Fire: Do not operate with the flue draft exceeding
.06″ (14.95 Pa) water column.
Consult a qualified Furnace installer, your local building inspector and your fire
officials to make sure the chimney and all connections conform to all local, state and
national codes and regulations.
Your venting system is an extremely important
part of any solid-fuel heating appliance
installation and has two key functions:
1. To exhaust smoke and flue gases which are
the natural result of combustion.
2. To provide “draft.” The draft pulls a
continuous supply of fresh air into the
furnace for proper combustion.
A chimney connector and chimney make up the
venting system and must be properly installed
and maintained to protect against a fire. Consult
a venting professional.
The ENERGY KING Wood/Coal Furnace
requires installation into a listed UL103 type HT
all-fuel chimney. Minimum 24 gauge black steel
chimney connector is required. An existing
chimney must be cleaned and inspected to be
sure it is clean and free from defect or damage.
All connections must comply with NFPA
Standard 211 and all applicable building codes
and regulations.
When installing a factory-built chimney, follow
all installation instructions provided by the
chimney manufacturer.
For best performance, RJM Manufacturing, Inc.
recommends using insulated chimney rather
than triple wall or air cooled chimney.
Important venting installation clearances and
points for proper operation and safety:
The connection from the ENERGY KING
Wood/Coal Furnace to the chimney must be
made using 6″ black steel material with a
minimum 24 gauge. Do not use galvanized
steel. See Chimney Connector.
Secure all connector pipe joints with at least
three sheet metal screws.
Any horizontal runs of chimney connector
pipe should have a minimum rise of 1/2-inch
per linear foot.
A minimum distance of 18 inches must be
maintained between the chimney connector
and combustible ceiling surfaces. A
minimum of 18 inches must be maintained
between the chimney connector and the
backwall and a minimum of 20 inches must
be maintained between the chimney
connector and sidewalls.
Avoid using more than two elbows in
connecting the ENERGY KING Wood/Coal
Furnace to the chimney.
Use extra support hangers or brackets every
three feet if it is absolutely necessary to have
a run of more than six feet, which is not
recommended.
The Chimney must be at least 3 feet higher
than the highest point where it passes
through the roof, and at least 2 feet higher
than the highest part of the roof or structure
that is within 10 feet of the chimney,
measured horizontally. For best performance,
RJM Manufacturing, Inc. recommends a
chimney height of at least 12 feet.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 18
Page 25
Installation
The Chimney must be at least 3 feet higher than the highest point where it passes through the roof,
and at least 2 feet higher than the highest part of the roof or structure that is within 10 feet of the
chimney, measured horizontally. For best performance, RJM Manufacturing, Inc. recommends a
chimney height of at least 12 feet.
Figure 11: Venting Requirements:
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 19
Page 26
Installation
Masonry Chimney
When connecting to an existing masonry chimney, an approved liner must be used in the chimney.
An unlined chimney could remain cold and cause a downward pressure which creates the
environment for poor burning, incomplete combustion, or backdraft.
Chimney Connector
The connection from the ENERGY KING Wood/Coal Furnace to
the chimney must be made using 6″ black steel material with a
minimum 24 gauge. Do not use galvanized steel.
For proper operation, the chimney connector should be as short
as possible. Horizontal lengths of chimney connector should
have an upward slope of 1/2-inch per foot. Use extra support
hangers or brackets every three feet if it is absolutely necessary
to have a run of more than six feet, which is not recommended.
Chimney connector sections must be attached to the heating
appliance and to each other with the crimped end toward the
heating appliance. Secure all chimney connector pipe joints with
at least three sheet metal screws. Avoid using more than two
elbows in connecting the ENERGY KING Wood/Coal Furnace to
the chimney.
Never use chimney connector pipe as a chimney.
A minimum distance of 18 inches must be maintained between
the chimney connector and combustible ceiling surfaces.
A minimum of 18 inches must be maintained between the chimney connector and the backwall and
a minimum of 20 inches must be maintained between the chimney connector and sidewalls.
DO NOT PASS CHIMNEY CONNECTOR THROUGH A COMBU STIBLE WALL OR CEILING.
Figure 12: Chimney
Connector Section
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 20
Page 27
Installation
Barometric Draft Control
Proper draft must be provided for your
ENERGY KING Wood/Coal Furnace. Draft is
the force that moves air from the furnace up
through the chimney, and is measured in
inches of water column.
The amount of draft in your chimney depends
on the length of the chimney, local geography,
nearby obstructions and other factors. Too
much draft may cause the fire to burn too fast,
while inadequate draft may cause smoke to
back up into the ENERGY KING Wood/Coal
Furnace, creating a possible hazard. A
barometric draft regulator must be installed into
the chimney connector. Please see Figure 13: Barometric Draft Control.
Draft regulators limit the draft (the suction
pulling air into the solid-fuel heating appliance
burn chamber). A pivoted, counterbalanced flap
is pulled open by the draft when the draft
Risk of Fire: Do not operate with the flue draft
exceeding .06″ (14.95 Pa) water column.
Moderate draft in
the chimney will
pull the
barometric draft
control open just
enough to
maintain the
appropriate draft
for your heating
appliance.
Figure 13: Barometric Draft Control
reaches a critical amount. This permits air to
enter the chimney, thus preventing the draft in
the solid-fuel heating appliance from rising any
higher.
Install the barometric draft control as close to
the Furnace as possible. On extremely tall
chimneys or chimneys larger than 6″, it may be
necessary to install a second barometric draft
control, or reduce the outlet opening of the
chimney to approximately 28 square inches, or
both, to maintain the chimney draft to .04″ to
.06″ water column of draft.
After installation of the ENERGY KING
Wood/Coal Furnace is complete and a fire has
been built, the chimney draft should be
established and maintained from .04″ to .06″
water column of draft. If this setting is
exceeded, it could cause a solid fuel fire to
burn out of control.
With no draft in the
chimney, the barometric
draft control remains
closed, allowing no air
to enter.
Excessive draft in
the chimney will
pull the
barometric draft
control further
open, allowing
more air into the
chimney and
reducing the draft.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 21
Page 28
Installation
Air Duct Installation
The duct or air distribution system circulates heated and/or cooled air to all the conditioned rooms in
a house. They must be properly designed and installed to be efficient, maintain uniform
temperatures throughout the house, and not adversely affect comfort or indoor air quality.
Important duct system installation details for safe and efficient operation of your ENERGY KING
Wood/Coal Furnace:
Every ENERGY KING Wood/Coal Furnace
must be installed with a cold air return. Cold
air returns must be equal in size to the
heated air outlets, and preferably 10% larger.
The plenum must be constructed of metal
(minimum 28 gauge galvanized is
recommended) and must be installed in
accordance with NFPA guidelines.
The plenum should be:
o 18 inches by 18 inches for the models
360EK/365EK
o 20 inches by 20 inches for the model
480EK
The plenum must be no closer than 2 inches
from the ceiling or any combustible material.
This clearance is critical during a power
outage since excessive heat buildup in the
plenum top may be dangerous.
Do not connect the ENERGY KING warm air supply outlet
into the cold air return inlet of the central furnace. The
components of the central furnace could overheat causing
the central furnace to operate other than intended.
When connecting the plenum to your warm-
air-supply duct system, never supply less
than 150-square inches of constant heated
air outlet area.
The warm-air-supply duct system must be
constructed of materials with a minimum
temperature rating of 250 degrees
Fahrenheit.
The ducts, fittings and registers should be
sized so that the total external static
pressure does not exceed 0.2.
Ductwork clearance requirements vary.
Contact your local building or fire officials
about installation restrictions and inspection
requirements in your area. Ductwork
installation must conform to local, state, and
national codes and regulations.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 22
Page 29
Operation
General Instructions
Do not operate with flue draft exceeding .06″ (14.95 Pa) of
water column.
Do not operate with fuel loading or ash removal doors open.
Do not store fuel or other combustible material within marked
installation clearances
Inspect and clean flues and chimney regularly.
Please read this manual in its entirety prior to the first firing of your ENERGY KING Wood/Coal
Furnace. It is very important that you follow these suggestions and limitations in order to maintain
your warranty and to guarantee the long life of your ENERGY KING Wood/Coal Furnace.
This ENERGY KING Wood/Coal Furnace is
designed to burn for about 6 to 8 hours per
load of wood or coal. If the ENERGY KING
Wood/Coal Furnace is being fired hot
constantly with full flames and operating at only
a 2 to 4 hour burn cycle, it is being overfired.
Your home heating needs may be too great for
the size of Furnace you have purchased.
Sometimes you need to allow your existing
conventional heating system to assist you in
colder weather. Your ENERGY KING
Wood/Coal Furnace can be damaged if it is
constantly fired at extremely high temperatures.
Forced firing or abuse can be detected upon
inspection and will void your warranty.
First Fire
Before lighting your first fire, inspect your ENERGY KING Wood/Coal Furnace to ensure that it has
been properly installed and that all safety requirements have been met. During your inspection, pay
particular attention to the clearances to combustibles, venting, and thermostat installation
instructions.
Check to make sure that your blowers are in
proper working order.
To check the circulation blower, use the
manual switch on the fan/limit control.
If you selected Forced Air Draft, you can
check the forced draft blower by turning
the wall thermostat supplied with your
ENERGY KING to a high temperature. If
your draft blower turns on, you may set
the wall thermostat to the desired setting.
Risk of Fire:
CAUTION – Hot Surfaces: Keep children away!
Do not touch Furnace during operation.
During the warmer seasons of spring and fall,
you should control the heat output by limiting
the amount of fuel, rather than the air supply.
Shorter, hotter fires will allow your
ENERGY KING heating appliance to operate at
maximum efficiency and with minimum
emissions.
For best combustion efficiency, chimney
temperature should be 350-degrees F to 450degrees F. RJM Manufacturing, Inc.
recommends installing a magnetic chimney
thermometer to monitor chimney temperature.
Next, make sure that the burn chamber and
ash removal pan are clear of all objects.
Do not fully load your ENERGY KING
Wood/Coal Furnace or open all draft controls
completely until you become familiar with the
operation of your ENERGY KING Wood/Coal
Furnace.
Some odors may be given off a new
ENERGY KING Wood/Coal Furnace during the
initial few hours of burning while the steel and
the paint are being cured. Ventilating the room
until the odors disappear is recommended.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 23
Page 30
Operation
Typical Operation Cycle
Do not operate with flue draft exceeding .06″ (14.95 Pa) water
column.
Do not operate with fuel loading or ash removal doors open.
Do not store fuel or other combustible material within marked
installation clearances
Inspect and clean flues and chimney regularly.
After a fire has been established and the
operating temperature has been reached, only
the thermostat needs to be set to maintain the
desired temperature.
When your home cools, the thermostat located
in the living area of the home activates the draft
control system.
If you selected Automatic Draft, the
automatic draft damper will open, allowing
your chimney’s natural draft to pull
combustion air into the burn chamber.
If you selected Forced Air Draft, the
combustion fan turns on, forcing combustion
air into your burn chamber.
If you selected Manual Draft, there is not a
thermostat that will regulate the amount of
combustion air in your Furnace.
o For a higher burn rate, turn the manual
draft spin dial to the left.
o For a lower burn rate, turn the manual
draft spin dial to the right.
o The manual draft spin dial can be set to
any position between high and low to
achieve the desired burn rate for your
home.
Power Failure Instructions
To operate your ENERGY KING Wood/Coal Furnace in the event of a power failure:
1. Close draft dial on ash door.
2. Remove air filter.
3. Open all heat registers.
4. Do not load the Furnace more than 1/4 full.
5. Keep sliding smoke baffle closed.
Use extreme caution when operating your ENERGY KING Wood/Coal Furnace during a power failure.
Over-firing can damage the furnace and its components, will void your warranty, and may result in
property damage, bodily injury or even death.
Risk of Fire:
CAUTION – Hot Surfaces: Keep children away!
Do not touch Furnace during operation.
The 3-speed circulation blower is activated
when the temperature sensor of the fan/limit
control indicates that air has been heated to the
fan/limit control ON temperature setting. The
circulation blower pushes air around the burn
chamber, through the heat exchanger area and
into the plenum.
When the thermostat is satisfied, it will
deactivate your automatic or forced air draft
control system, allowing the fire to die down
until the next time your thermostat calls for
heat.
Your ENERGY KING Wood/Coal Furnace can
run efficiently over extended periods of time
and at different heat output levels as long as
the fuel supply is uninterrupted and cleaning
and maintenance are performed routinely.
Always closely monitor the operation of the
ENERGY KING Wood/Coal Furnace during a power failure.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 24
Page 31
y op
Operation
BURN AIR-DRIED WOOD, OR ANTHRACITE OR BITUMINOUS COAL ONLY
Burning Wood
All home chimneys and hookups are different. After a few fires, you will find the best way to start a
fire in your ENERGY KING Wood/Coal Furnace.
Your ENERGY KING Wood/Coal Furnace is capable of holding very large logs. Do not try to add a
log that is larger than what you can easily place in the ENERGY KING Wood/Coal Furnace. You will
get the best efficiency when you add only the amount of wood needed for a 6 to 8 hour burn. Note:
A full load is not always the best solution for your needs.
Starting a Wood Fire
1. Pull the sliding smoke baffle (located above
the fuel loading door) out to open.
2. Place a small amount of crumpled paper in
the center of your ENERGY KING
Wood/Coal Furnace. Crisscross a couple of
handfuls of dry, 3/4″ thick kindling wood,
then several small pieces of firewood.
Be sure the sliding smoke baffle
is full
en.
3. It will take 5 to 10 minutes for the fire to
establish itself. Once you have some redhot burning embers, add larger pieces of
wood.
a. Vary the position of the wood in the burn
chamber to maximize the exposed
surface area of each piece of wood.
b. Only use wood properly sized for your
unit’s burn chamber.
Never overload your burn
chamber. Do not load wood
more than 8 inches above the
top of the firebrick.
4. Push in the sliding smoke baffle after
loading your ENERGY KING and the fire
has been established.
5. The burn time is controlled totally by the
automatic or forced air draft controls on the
furnace.
Manual Draft: If you selected Manual draft,
you control the burn rate of your
ENERGY KING Wood/Coal Furnace.
For a higher burn rate, turn the manual
draft spin dial to the left.
For a lower burn rate, turn the manual
draft spin dial to the right.
The manual draft spin dial can be set to
any position between high and low to
achieve the desired rate of burn for your
home.
Refueling
To refuel the wood fire in your ENERGY KING
Wood/Coal Furnace:
1. Pull the sliding smoke baffle out.
2. Open the fuel loading door slowly: open the
door about 1″-2″ then wait about 10
seconds before opening fully. Never stand
in front of the fuel loading door when
refueling; always stand to the side.
3. Rake the red-hot embers over the grates
evenly.
4. Put a few smaller pieces of wood on the
coals first, and then load the furnace with
larger pieces of wood.
5. Close the fuel loading door and sliding
smoke baffle.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 25
Page 32
Operation
BURN AIR-DRIED WOOD, OR ANTHRACITE OR BITUMINOUS COAL ONLY
All home chimneys and hookups are different. After a few fires, you will find the best way to start a
fire in your ENERGY KING Wood/Coal Furnace.
You will get the best efficiency when you add only the amount of coal needed for a 6 to 8 hour burn.
Note: A full load is not always the best solution for your needs.
Burning Coal
Burning coal will provide a lesson in patience.
Take the time necessary to experiment and
understand the operation of your
ENERGY KING Wood/Coal Furnace.
Please keep the following points in mind when
burning coal:
1. A Barometric draft control in the chimney
connector must be used when burning coal.
2. Never completely cover the live fire with
fresh coal. Always leave a generous area of
burning coal at the top and rear of the fire.
3. Always keep the ash pan clean. Coal firing
produces much more ash than wood. These
ashes must be removed often (possible
daily) in order to avoid piling up too closely to
the grates.
Removal of the coal ash will allow for
passage of primary air to the coal bed and
prevent damage or warpage to the grates.
Dispose of ashes with care:
Ashes should be placed in a metal
container with a tight fitting metal lid.
The closed container of ashes should
be placed on a noncombustible floor
or on the ground, well away from all
combustible materials, pending final
disposal.
All coal contains small amounts of
dangerous elements. Therefore it is
essential that your coal ash be
disposed of in municipally designated
areas.
4. A coal fire should not be poked or broken up,
as this tends to bring ash to the surface of
the coal bed where it may fuse. If the ash
fuses, clinkers will form. It may be necessary
to remove all unburned material and ash
from the burn chamber to remove the
clinkers. These should be carefully removed
using tongs, and always put into an airtight
metal container.
5. If the fire goes out or does not hold
overnight, check for the following:
a. Poor Draft
b. Incorrect damper settings.
c. Improper firing methods for the coal being
used.
d. Coal is not sized to the furnace (see Fuel
Requirements – Coal).
e. Ashes, if allowed to accumulate in the ash
pan, will not allow the passage of required
air for combustion. Keep the ash pan
clean.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 26
Page 33
y op
Operation
Starting a Coal Fire
1. Pull the sliding smoke baffle (located above
the fuel loading door) out to open.
2. Place a small amount of crumpled paper in
the center of your ENERGY KING
Wood/Coal Furnace. Crisscross a couple of
handfuls of dry, 3/4” thick kindling wood,
then several small pieces of firewood. Wait
until the wood fire is established with hot, red
embers before adding coal.
3. It will take 5 to 10 minutes for the wood fire
4. After the coal fire is established and spread
5. Push in the sliding smoke baffle after loading
6. The burning time is controlled totally by the
Check the fire periodically to make sure it is
spreading throughout the coal bed.
Be sure the sliding smoke baffle
is full
en.
to establish itself. Once you have some redhot burning embers, add several small
shovels of coal over the wood coals until you
have a 2″-3″ bed of burning coals. Be sure
to give each small layer about 5-10 minutes
to ignite before covering it with the next layer
of coal.
throughout the burn chamber, gently shake
the grate until ashes fall in the ash removal
pan. Add larger amounts of coal to build up
the coal bed.
Never overload your burn
chamber. Do not load coal above
the top of the firebrick.
your ENERGY KING Wood/Coal Furnace
and your fire is established.
draft controls on the furnace. Allow your
ENERGY KING Wood/Coal Furnace to
operate with draft controls fully open for
approximately 15 minutes or until the fresh
coal ignites. When the coal is properly
ignited, adjust the thermostat accordingly.
Refueling / Recharging
To refuel/recharge the anthracite coal fire in
your ENERGY KING Wood/Coal Furnace:
1. Pull the sliding smoke baffle out.
2. Gently shake the grates down
3. Open the fuel loading door slowly: open the
door about 1″-2″ then wait about 15 to 20
seconds before opening fully.
When recharging, fresh coal tends
to give off large quantities of
volatile gas which may accumulate
and possibly ignite, causing a
backpuff. Always open the fuel
loading door slowly to prevent
backpuffing.
Never stand in front of the fuel
loading door when refueling;
always stand to the side.
4. If the coal fire has died down before
recharging, a fresh supply of kindling will
need to be added. Only add fresh coal to a
deep, hot bed of coals.
5. Spread fresh coal evenly over existing coal,
leaving some hot coals exposed in the
center of the burn chamber. Be careful not to
smother your existing coals.
Never overload your burn
chamber. Do not load coal above
the top of the firebrick.
6. Close the fuel loading door and sliding
smoke baffle.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 27
Page 34
Operation
Bituminous Recharging
Because bituminous coal has higher sulfur
content, bituminous recharging is slightly
different from anthracite recharging.
To refuel/recharge the bituminous coal fire in
your ENERGY KING Wood/Coal Furnace:
1. Pull the sliding smoke baffle out.
2. Gently shake the grates down
3. Open the fuel loading door slowly: open the
door about 1″-2″ then wait about 15 to 20
seconds before opening fully.
When recharging, fresh coal tends
to give off large quantities of
volatile gas which may accumulate
and possibly ignite, causing a
backpuff. Always open the fuel
loading door slowly to prevent
backpuffing.
Never stand in front of the fuel
loading door when refueling;
4. If the coal fire has died down before
recharging, a fresh supply of kindling will
need to be added. Only add fresh coal to a
deep, hot bed of coals.
5. Push the hot coals to the rear of the burn
chamber and position fresh coal on the grate
in front of the banked coal. Be careful not to
smother your existing coals.
6. Close the fuel loading door and sliding
smoke baffle.
always stand to the side.
Never overload your burn
chamber. Do not load coal above
the top of the firebrick.
Banking
Banking allows you to recharge your coal fire in
such a manner as to retain a hot coal bed
throughout the night.
Approximately one hour before retiring for the
night, push the coals to the rear of the burn
chamber with the coal tapered down in the
front.
Be careful not to smother your existing coals.
Never overload your burn
chamber. Do not load coal above
the top of the firebrick.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 28
Page 35
Maintenance
Periodic maintenance is required to continue the performance of your ENERGY KING Wood/Coal
Furnace. As with any solid-fuel heating appliance, the need for and frequency of cleaning depends
on the amount and quality of fuel burned, the quality of the fire, and the length of time since the last
cleaning. Weekly cleaning may be required in warmer weather, whereas monthly cleaning may be
enough in colder weather.
Before the first fire of each new heating season, check all installations and accessories to ensure a
safe burning process.
Creosote – Formation and Need for
Removal
When wood is burned slowly, it produces tar
and other organic vapors, which combine with
expelled moisture to form creosote. The
creosote vapors condense in the relatively cool
chimney flue of a slow-burning fire. As a result,
creosote residue accumulates on the flue
lining. When ignited, this creosote makes an
extremely hot fire, the results of which can be
tragic.
Check daily for creosote build up until
experience shows how often cleaning is
necessary. The chimney connector and
chimney should be inspected at least twice
monthly during the heating season to
determine if a creosote buildup has occurred. If
creosote has accumulated, it should be
removed to reduce the risk of a chimney fire.
Be aware that the hotter the fire, the less
creosote is deposited, and that weekly cleaning
may be necessary in mild weather, even
though monthly cleaning may be enough in the
coldest months.
Have a clearly understood plan to handle a
chimney fire.
Rev 03/12/14 ENERGY KING
Risk of electric shock. Disconnect power at the service
panel or breaker box before servicing ENERGY KING
Wood/Coal Furnace.
Keep the area around the ENERGY KING Wood/Coal
Furnace clean and free of dust and debris.
Disposal of Ashes
Ashes should be placed in a metal container
with a tight fitting metal lid. The closed
container of ashes should be placed on a
noncombustible floor on the ground, well away
from all combustible materials, pending final
disposal.
If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be
retained in the closed container until all ash
and cinders have thoroughly cooled. Do not
place any other waste materials in this
container.
All coal contains small amounts of dangerous
elements. Therefore it is essential that your
coal ash be disposed of in municipally
designated areas.
NOTE: EMBERS REMAIN HOT FOR
MANY DAYS. STORE IN A SAFE PLACE
Never use a conventional vacuum cleaner or a
shop vacuum to remove ashes from a solid-fuel
heating appliance. Ashes remain hot for many
days, and when trapped in a conventional
vacuum can cause a fire hazard. Only use a
vacuum designed for the safe cleaning and
removal of ashes.
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 29
AWAY FROM COMBUSTIBLES.
Page 36
Maintenance
Gasket Replacement
The cast iron fuel loading and ash removal doors of your ENERGY KING Wood/Coal Furnace are
equipped with gaskets to ensure safe operation and an airtight seal. When these gaskets become
worn or damaged, you will need to replace them.
To replace the gaskets you will need 3/4-inch, high temperature rope gasket, available from your
ENERGY KING dealer or hardware store.
1. Remove the door and lay it face down on a
clean, flat surface.
2. Find the ends of the gasket and pull it off.
3. Using a screwdriver, remove any excess
gasket cement from the gasket channel.
4. If desired, a small drop of gasket cement
may be applied to the corners of the gasket
channel.
5. Lay the new door gasket in the channel,
cutting off any excess gasket rope.
Figure 14: Door Gasket
6. Reattach the door. If gasket cement was
applied, keep the door closed until the
cement has fully dried.
Routine Maintenance
Please use the following timeline as a guide for determining how much maintenance your
ENERGY KING Wood/Coal Furnace requires to operate at peak performance. Failure to clean and
maintain this Furnace as indicated can result in poor performance and safety hazards.
Please use Appendix D: Purchase & Service Record to keep a record of your maintenance and
service practices. In the event of a warranty claim, we may request a copy of this record.
Inspect flue pipes, joints and seals regularly
to ensure that smoke and flue gases are not
drawing into the home.
Daily
Until a pattern of cleaning requirement is established, inspect and, if necessary, clean the following
components daily:
Fuel Supply, refilling as necessary.
Flue Pipes, including joints and seals, should
be inspected to ensure that smoke and flue
gases are not drawn in and circulated by the
air-circulation system.
Ash removal pan should be emptied and
cleaned regularly. Ash content is a good
indicator of fuel efficiency and quality. High
quality fuel will produce less ash than lower
quality fuel. Never allow ash to build up to
the level of the grates.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 30
Page 37
Maintenance
Every 2 – 3 Days / Weekly
Once a pattern of cleaning requirement is
established, the following components should
still be monitored on a regular basis:
Burn chamber
Ash removal pan
Flue pipes, joints and seal
Monthly
The air filter on your ENERGY KING
Wood/Coal Furnace should be monitored on a
regular basis and replaced when necessary.
Annual / Spring Shutdown
Seasonally / Every 3 Months / After
every 1 – 2 Tons of fuel burned
Until you are familiar with how ash and
creosote accumulate with your operating
practices, we recommend inspecting your
ENERGY KING Wood/Coal Furnace at least
once per ton of fuel burned. Particular
attention should be given to:
Draft Control system (motors, blowers,
etc.)
Gaskets (Fuel loading and Ash Removal
Doors)
Air Filter
Fresh air intake
Chimney
Cleaning the flue pipe and chimney is especially important at
the end of the heating season to minimize corrosion during
the summer months caused by accumulated ash.
It is important to give the entire ENERGY KING Wood/Coal Furnace a thorough cleaning:
Your venting system should be inspected
and cleaned annually. Clean and remove
fly ash from chimney connector, flue pipes
and chimney. Soot buildup should be
removed to prevent the risk of a chimney
fire and to minimize corrosion during the
summer months.
Scoop out any unburned fuel from the burn
chamber, and empty and clean the burn
chamber and ash removal pan.
○ Do not allow fuel or ash to sit in the
ENERGY KING Wood/Coal Furnace
over the summer months. Fuel and ash
can accumulate moisture over the
summer months having a corrosive
effect on metal and cast iron parts, and
causing the fuel to mold.
Failure to clean and maintain this Furnace as indicated can result in poor performance and safety
hazards.
Please use Appendix D: Purchase & Service Record to keep a record of your maintenance and
service practices. In the event of a warranty claim, we may request a copy of this record.
Remember: A clean Furnace burns efficiently and will remain trouble free!
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 31
Page 38
Troubleshooting Guide
Many problems in the ENERGY KING Wood/Coal Furnace can be traced to a few commonplace
causes and are easily fixed. Before making any repairs or replacing any components, be sure to
check for these common problems:
Fuel
Wet or Dirty fuel
Solution: Empty and clean the burn chamber. Refill using only high
quality, clean, dry fuel as outlined in Fuel Requirements.
Improper Draft
Too little or too much draft
Risk of electric shock. Disconnect power at the service
panel or breaker box before servicing ENERGY KING
Wood/Coal Furnace.
Insufficient combustion air
Solution: Adjust the draft controls and observe until you determine
which settings are most appropriate for your usage. See Operation for
further information.
Ash buildup in the ash removal pan
Solution: Be sure to maintain your ENERGY KING Wood/Coal
Furnace’s cleanliness by emptying the ash removal pan regularly. See
Maintenance for further information.
We also recommend establishing a routine of inspecting gaskets and replacing when necessary.
Maintaining your ENERGY KING Wood/Coal Furnace’s cleanliness and adjusting the draft controls
will remedy many problems.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 32
Page 39
Troubleshooting Guide
Detailed Troubleshooting
Once you have exhausted the above common problems, if you are still experiencing trouble with
your ENERGY KING Wood/Coal Furnace, you may wish to consult the following list of problems, or
consult with your ENERGY KING dealer for further assistance.
Problem(s) Cause(s) / Solution(s)
Fire won’t start or starts but
won’t stay lit, or does not
hold out overnight
Fire is weak, lazy, or dirty,
or startup is slow or smoky
Make sure all furnace doors are closed tightly and all gaskets are
in good condition.
Ashes, if allowed to accumulate in the ash removal pan, will block
the passage of combustion air. Verify that your ash removal pan
is clean. Never allow ashes to build up to the level of the grates.
Your exhaust or combustion air systems may be blocked. Verify
all vents and pipes are free from obstruction and the draft controls
are operating correctly.
Check your chimney for downdraft caused by taller surrounding
trees or buildings. The chimney may have to be extended or a
chimney vent cap installed. Please contact your ENERGY KING
dealer or heating contractor.
Your fire may need more combustion air. Increase the amount of
combustion air by adjusting your draft controls.
Your exhaust or combustion air systems may be blocked. Verify
all vents and pipes are free from obstruction and the draft controls
are operating correctly.
Your home may have a negative pressure. If your home is too
airtight, the ENERGY KING heating appliance cannot get enough
combustion air to burn properly. You may need to bring outside
air to the ENERGY KING heating appliance. Please contact your
ENERGY KING dealer or heating contractor.
Smoke is visible or you
smell fumes in your home
Rev 03/12/14 ENERGY KING
Check your chimney for downdraft caused by taller surrounding
trees or buildings. The chimney may have to be extended or a
chimney vent cap installed. Please contact your ENERGY KING
dealer or heating contractor.
Make sure all doors are closed tightly and all gaskets are in good
condition.
Your exhaust or combustion air systems may be blocked. Verify
all vents and pipes are free from obstruction and the draft controls
are operating correctly.
Your venting may be improperly installed. If the ENERGY KING
heating appliance is smoking from vents, ducts, or from the draft
controls, immediately shut down the ENERGY KING heating
appliance, ventilate the area, and contact your ENERGY KING
dealer or heating contractor.
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 33
Page 40
Troubleshooting Guide
Problem(s)
Excessive creosote
Excessive Fire
Poor combustion or difficulty
maintaining a “pilot” fire
Cause(s) / Solution(s)
During warmer weather, you may need to adjust your firing
practices. For maximum efficiency and minimum emissions, try
shorter, hotter fires rather than large, slow-burning fires.
Your venting may be improperly installed. Verify that the
ENERGY KING heating appliance is vented according to
instructions found in the Installation section. Please contact your
ENERGY KING dealer or heating contractor.
There may be too much combustion air. Adjust the Furnace draft
controls.
The chimney draft may be excessive. Adjust the barometric
damper to maintain flue draft settings from 0.04″ to 0.06″ of water
column. Do not operate with a flue draft exceeding .06″ (14.95
Pa) water column.
Check the quality of your fuel. Refer to Fuel Requirements.
Your fire may need more combustion air. Increase the amount of
combustion air by adjusting your draft controls.
Your home may have a negative pressure. If your home is too
airtight, the ENERGY KING heating appliance cannot get enough
combustion air to burn properly. You may need to bring outside
air to the ENERGY KING heating appliance. Please contact your
ENERGY KING dealer or heating contractor.
Too much ash
Ash, soot, or fuel dust in the
home
Check the quality of your fuel. Refer to the Fuel Requirements
section.
Verify all Furnace doors are closed tightly and all gaskets are in
good condition.
Always be sure to handle ashes and fuel with care and open
doors slowly.
Ashes can escape from conventional vacuums. We recommend
using a vacuum designed for ashes.
Be sure to check the exhaust system for leaks and repair as
necessary.
Your home may have a negative pressure. If your home is too
airtight, the ENERGY KING heating appliance cannot get enough
combustion air to burn properly. You may need to bring outside
air to the ENERGY KING heating appliance. Please contact your
ENERGY KING dealer or heating contractor.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 34
Page 41
Troubleshooting Guide
Problem(s)
Partially burned or unburned
fuel in the combustion area
The ENERGY KING
heating appliance burns too
much fuel, or the fuel burns
off too quickly
The ENERGY KING
heating appliance is
overheating or is burning
without regard to the
thermostat
The ENERGY KING
heating appliance will not
heat the whole house or
doesn’t produce as much
heat as when first installed
Cause(s) / Solution(s)
More air for proper combustion may be needed. Verify that your
draft controls are working properly and that your exhaust and
combustion air systems are clean and free from obstruction.
The chimney draft may be excessive. Adjust the barometric
damper to maintain flue draft settings from 0.04″ to 0.06″ of water
column. Do not operate with a flue draft exceeding .06″ (14.95
Pa) water column.
Your ENERGY KING heating appliance may have been installed
incorrectly. Please contact your ENERGY KING dealer or heating
contractor.
The thermostat or thermostat wiring may be faulty. Please contact
your ENERGY KING dealer or heating contractor.
Verify that the venting and draft control systems are clean and
free from obstruction. Verify that all heat delivery systems are
operating correctly.
The circulation blower runs
continuously, cycles on and
off too much, or won’t run at
all
The ENERGY KING heating
appliance has power but is
not responding
The user is shocked when
touching the
ENERGY KING heating
appliance
Make sure the Fan/limit Control is set on Auto and is not on
Manual.
The fan/limit control ON/OFF temperature settings may need to
be adjusted. (ON/OFF temperatures may be set too close
together). Please see Assembly for recommended fan/limit
control settings.
Your furnace may have a faulty fan/limit control or blower motor.
Please contact your ENERGY KING dealer for replacement parts.
Check the power supply for adequate voltage. See the Installation
section for power supply requirements.
Your ENERGY KING may have been installed incorrectly. Please
contact your ENERGY KING dealer or heating contractor.
Your ENERGY KING may not have been properly grounded or
may have loose wires or wiring components. Disconnect power
to the ENERGY KING at the breaker box or service panel and
verify all connections. Please contact your ENERGY KING dealer
or heating contractor.
Your ENERGY KING heating appliance may have experienced a
power surge or power short. Please contact your ENERGY KING
dealer or heating contractor.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 35
Page 42
This page is intentionally left blank.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 36
Page 43
Appendix A: Wiring Diagrams
A-1: Automatic Draft Wiring Diagram
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 37
Page 44
Appendix A: Wiring Diagrams
A-2: Forced Air Draft Wiring Diagram
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 38
Page 45
Appendix A: Wiring Diagrams
A-3: Manual Draft Wiring Diagram
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 39
Page 46
This page is intentionally left blank.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 40
Page 47
Appendix B: Filter Box Assembly Schematic
T
HE FILTER MUST BE REMOVED IF
THE FAN IS INOPERABLE FOR ANY
REASON
FAILURE
OVERHEATING OF THE MOTOR
T
HE AIR FILTER MUST BE
-
COMBUSTIBLE
NON
.
Non-combustible air filters
are available from your
ENERGY KING dealer.
CAUTION
,
INCLUDING POWER
. T
HIS WILL PREVENT
.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 41
Page 48
This page is intentionally left blank.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 42
Page 49
Appendix C: Parts List
Electrical Components
Part Number Part Description
4-ELE-24VTHERMOST 24 Volt Wall Thermostat
4-ELE-CTRLBX-AD-F
Cast Iron Ash Removal Door
Cast Iron Draft Spin Dial with Hardware
3/4″ Rope Gasket
Gasket Cement (glue), 2 oz. Bottle (optional, not included)
Ash Door Handle
1/2″ Chrome Spring Handle
Door Pins (2 per door)
Door Handle Hardware
Cast Iron Fuel Loading Door
3/4″ Rope Gasket
Gasket Cement (glue), 2 oz. Bottle (optional, not included)
Fuel Loading Door Handle
5/8″ Chrome Spring Handle
Door Pins (2 per door)
Door Handle Hardware
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 44
4-GAS-DOOR 3/4″ Rope Gasket for Fuel loading and Ash Removal Doors
4-GAS-GSKTGLUE2OZ Gasket Cement (glue), 2 oz. Bottle (optional, not included)
4-HAN-1/2CHROME 1/2″ Chrome Spring Handle (for Ash Removal Door, Sliding Smoke
4-HAN-5/8CHROME 5/8″ Chrome Spring Handle (for Fuel Loading Door Hand le)
4-HAR-DOORPIN Door Pins, 4 Required (2 per door)
4-HAR-HANDLE-F/B Door Handle Hardware (for Fuel loading and Ash Removal Doors)
4-HOT-TUBE Domestic Hot Water Tube (Optional)
4-INS-365EK Insulation Blanket for 360EK/365EK
4-INS-480EK Insulation Blanket for 480EK
4-MISC-365SMOKBFL 360EK/365EK Slidi ng Smoke Baffle Assembly
4-MISC-ASHPAN365 Ash Removal Pan for 360EK/365EK
4-MISC-ASHPAN480 Ash Removal Pan for 480EK
4-PAI-SATINBL-AER Satin Black Paint
20″ x 20″ x 1″ Non-Combustible Filter (not included), available from your
ENERGY KING dealer or Grainger Supply (Part No. 2TE96 “Aluminum
mesh air filter”)
365EK Cabinet Panel (Shroud), Left Side
365EK Cabinet Panel (Shroud), Right Side
365EK Cabinet Panel (Shroud), Top Side
480EK Cabinet Panel (Shroud), Left Side
480EK Cabinet Panel (Shroud), Right Side
480EK Cabinet Panel (Shroud), Top Side
360EK/365EK requires 8 (4 per side)
480EK requires 12 (6 per side)
360EK/365EK requires 2 (1 per side)
Baffle, and Optional Shaker Grates Handles)
Sliding Smoke Baffle for 360EK/365EK
Smoke Baffle Slider Control Rod for 360EK/365EK
1/2″ Chrome Spring Handle & Hardware
Sliding Smoke Baffle for 480EK
Smoke Baffle Slider Control Rod for 480EK
1/2″ Chrome Spring Handle & Hardware
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 45
Page 52
This page is intentionally left blank.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 46
Page 53
Appendix D: Purchase & Service Record
A
NNUAL INSPECTION BY QUALIFIED PROFESSIONAL IS RECOMMENDED
Purchase & Installation Record
M
ODEL
*
D
EALER
A
DDRESS
C
C
P
C
ITY / STATE / ZIP
ONTACT
HONE NUMBER
OMMENTS
S
ERIAL NUMBER
*
P
URCHASE DATE
I
NSTALLER
A
C
C
P
DDRESS
ITY / STATE / ZIP
ONTACT
HONE NUMBER
.
I
NSTALLATION DATE
*Model and serial number are located on the label on the lower left front of the unit.
Service & Maintenance Record
D
ATE
T
ECHNICIAN
D
ESCRIPTION OF WORK DONE
Have you completed & returned your warranty card? Date Mailed:
Has Dealer / Installer gone over the operation and maintenance of appliance?
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 47
Page 54
Appendix E: Warranty Claim Procedures
We make every effort to ensure that all ENERGY KING heating appliances and components adhere to our
strict standards for quality and safety. However, should you receive a product or component that doesn't
function as intended, please follow the instructions below for making a warranty claim. We will replace o r repair
the part, as outlined in the applicable warranty, as soon as possible to keep your ENERGY KING heating
appliance functioning safely and efficiently as intended.
Parts
Units
To make a warranty claim on faulty parts
provided with an ENERGY KING heating
appliance, please contact your ENERGY KING
dealer.
If your ENERGY KING dealer is unavailable:
1. Please complete a Warranty Claim Form
and return it to us. All warranty claim
requests must be made in writing; verbal
warranty claim requests will not be
processed.
The following information is required when
submitting a warranty claim:
Model number
Serial Number
Purchase Date
Purchaser Name, Address, and
Telephone
2. Additionally, if you have not mailed in your
Warranty Registration Card, we will require
a completed Warranty Registration Card to
be returned to us along with dated proof of
purchase (i.e. a copy of your receipt or
invoice).
We may also request a copy of the Service
& Maintenance Log located in the Appendix
of your Owner’s Manual.
Without this information, we will not be able
to complete your requested warranty claim.
Once we receive your completed Warranty Claim Form and Warranty Registration Card,
we will ship a replacement for the faulty part(s).
All transportation charges are to be paid for by
the purchaser. However, if a faulty part is to be
returned to us, we will provide return-shipping
To make a warranty claim on a faulty
ENERGY KING heating appliance, please
contact your ENERGY KING dealer.
If your ENERGY KING dealer is unavailable,
please contact us at (715) 720-1794 for
instructions.
When contacting RJM Manufacturing, Inc for a
warranty claim on a faulty ENERGY KING
heating appliance, please have the following
information ready:
Model number
Serial Number
Purchase Date
Purchaser Name, Address, and
Telephone
Additionally, if you have not mailed in your
Warranty Registration Card, we will require a
completed Warranty Registration Card to be
returned to us along with dated proof of
purchase (i.e. a copy of the receipt or invoice).
We may also request a copy of the Service &
Maintenance Log located in the Appendix of
your Owner’s Manual.
Without this information, we will not be able to
complete your requested warranty claim.
All transportation charges are to be paid for by
the purchaser.
via a call-tag.
RJM Manufacturing, Inc. reserves the right to refuse any warranty claim, subject to the terms, conditions and
restrictions of the warranty agreement found in the corresponding ENERGY KING installation & operation
manual.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 48
Page 55
Appendix E: Warranty Claim Procedures
ENERGY KING® Solid-Fuel Heating Appliances
Warranty Claim Form
For all ENERGY KING warranty claims, please complete this form IN FULL and return it to
RJM Manufacturing, Inc., via fax at (715) 720-1797 or via postal mail at:
RJM Manufacturing, Inc., 1875 Olson Drive, Chippewa Falls, WI 54729
DEALER:
ATTENTION:
ADDRESS 1:
ADDRESS 2:
CITY, ST, ZIP
TELEPHONE:
FAX:
EMAIL:
Model: Serial No: Date of Purchase: Date of Failure: Date of Repair:
Description of Failure / Repairs Made (please be specific):
Signature: Date:
PURCHASER:
ATTENTION:
ADDRESS 1:
ADDRESS 2:
CITY, ST, ZIP:
TELEPHONE:
QTY
Miscellaneous:
Copies of invoices / receipts are required for all credits claimed on this form.
RJM Manufacturing, Inc. reserves the right to refuse any warranty claim, subject to the terms, conditions and
restrictions of the warranty agreement found in the corresponding ENERGY KING installation & operation
manual.
Rev 03/12/14 ENERGY KING
PART NO.
(if applicable)
PARTS REPLACED
DESCRIPTION Faulty?
Return
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 49
Page 56
This page is intentionally left blank.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 50
Page 57
ENERGY KING W
L
IMITED WARRANTY
Who is covered?
You are covered under this warranty if you are the original purchaser of a new ENERGY KING solid-fuel
heating appliance and your purchase was made through an authorized distributor/dealer of the
ENERGY KING solid-fuel heating appliance.
How long does the coverage last?
The term of this warranty begins on the date of original purchase as evidenced by your purchase receipt,
subject to the terms, conditions and restrictions of this agreement. Coverage is extended to you for the
following time periods:
Burn chamber. The burn chamber is warranted for six (6) years on a prorated basis. The replacement
value will decrease each year until the maximum life of the warranty exhausts any replacement value.
Replacement value is reduced according to the following schedule and will be calculated on the cost of the
burn chamber at the time the part is repaired or replaced. We will provide you with a credit to be applied
towards the cost of the repair or replacement part.
Year 1 Full Warranty
Year 2 80% Credit
Year 3 60% Credit
Year 4 40% Credit
Year 5 25% Credit
Year 6 15% Credit
Castings. The castings are warranted for one (1) year and include the fuel loading door, ash removal door,
hearth plates, and grates.
Electrical Components. The electrical components are warranted for one (1) year and include, but are not
limited to, the draft damper control motor or combustion fan, and all components of the control box.
What is covered by this warranty?
This warranty covers any defects in materials or workmanship in your new ENERGY KING solid-fuel heating
appliance.
What is not covered by this warranty?
This limited warranty does not apply:
If your appliance has not been installed, operated and maintained in strict accordance with instructions
provided in the Installation, Operation and Maintenance Manual.
If any part has been damaged in shipment, modified, altered, tampered with, abused, or has been subject
to accident or misuse.
If your appliance has been altered or repaired in a manner which, in our sole judgment, affects its
performance, stability or reliability.
If parts not made or supplied by us have been used in connection with the appliance, if in our sole
judgment, such use affects its performance, stability or reliability.
To transportation charges on appliances and appliance parts submitted for rep air or replacement under this
warranty.
To expendable, replaceable or wear items, such as firebrick, gaskets/seals, paint, handles and other items
that in our judgment are expendable, replaceable or wear items.
To any heating system or systems to which the appliance may be attached.
To any of the smoke pipes, heat pipes, chimney, hardware, ducting, vents, or other accessories used for
the installation and venting or ducting of the appliance.
We are not responsible for installation and will not be liable in any respect under the terms of the warranty for
injury or damage to the building structure in which the appliance has been installed, or to the person or
persons and property therein, arising out of the use, or installation of the ENERGY KING appliance. The
appliance must be installed in compliance with the state, local national building and fire codes and regulations
of the area and in strict adherence to the Manufacturer’s recommendations.
OOD/COAL FURNACE
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 51
Page 58
What will we do to correct problems?
We will repair, or at our option, replace any ENERGY KING solid-fuel heating appliance or appliance part,
which upon inspection shows a defect in materials or workman ship .
How can you get service?
If warranty service is needed during the warranty period, notify your authorized ENERGY KING dealer. If
there is no ENERGY KING dealer in your area, contact RJM Manufacturing, Inc. directly. Provide your name,
address, phone number, serial number and model number of the furnace, date of purchase, name and
address of installer and a description of the problem.
Disclaimer of Implied Warranties & Consequential Damages
Our obligation under this limited warranty, to the extent allowed by law, is in lieu of all warranties, implied or
expressed, including implied warranties of merchantability and fitness for a particular purpose and any liability
for incidental and consequential damages with respect to the sale or use of the items warranted. Such
incidental and consequential damages shall include but not be limited to: transportation / freight charges, cost
of installation, duty, taxes, charges for service or adjustment, loss of income, rental or substitute equipment,
and expenses due to loss, damage, detention or delay in the delivery of equipment or parts resulting from
acts beyond our control.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation of
implied warranties, so the limitations or exclusions in this limited warranty may not apply to you.
NO EMPLOYEE OR REPRESENTATIVE OF RJM MANUFACTURING, INC. IS AUTHORIZED TO CHANGE
THIS LIMITED WARRANTY IN ANY WAY OR GRANT ANY OTHER WARRANTY UNLESS SUCH CHANGE
IS MADE IN WRITING BY AN OFFICER OF RJM MANUFACTURING, INC. AT ITS HOME OFFICE.
YOUR RESPONSIBILITY UNDER THE WARRANTY
It is your responsibility to ensure that the appliance is installed in compliance with local, state and national
building and fire codes regulating installation and inspection.
It is your responsibility to complete the warranty card and return it to the address indicated within 30 days of
the purchase. You must also keep your receipt as proof of date of purchase. Failure to do so will mean that
you may not later make a claim under this warranty.
It is your responsibility to read the Installation, Operation & Maintenance Manual and to install, operate and
maintain the appliance in accordance with all instructions and safety procedures. Failure to do so is a misuse
of the appliance.
It is your responsibility to inspect the appliance and to have any part(s) repaired or replaced when continued
operation would cause damage or excessive wear to other parts or cause a safety hazard.
It is your responsibility for any cost incurred by the distributor/dealer for travel to or transportation of the
product for the purpose of performing a warranty obligation or inspection.
RJM Manufacturing, Inc.
1875 Olson Drive
Chippewa Falls, WI 54729
(715) 720-1794 ♦ Fax (715) 720-1797
Email: [email protected]
www.energyking.com
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 52
Page 59
Supplement A: 24-V Wall Thermostat
The following document was prepared and published by Honeywell International for distribution with
their models “T822K,L & T827K” wall thermostats.
It is reproduced here for reference purposes ONLY.
Rev 03/12/14 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 53
Page 60
Page 61
Page 62
Page 63
Page 64
Page 65
Supplement B: Fan/Limit Control
The following document was prepared and published by Honeywell International for distribution with
their models L4064B2640/B fan limit controls.
It is reproduced here for reference purposes ONLY.
Rev 05/05/11 ENERGY KING
®
360EK/365EK/480EK Wood/Coal Furnace Owner’s Manual U. S. 59
Page 66
Page 67
Page 68
Page 69
Page 70
Page 71
Page 72
Page 73
Page 74
Page 75
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.