Energizer ER-CH2 User Manual

On Off
On
Error
Diagram 6
MED
HI
MAX
Error Condition - Charge Terminated: If the battery is
Sequential
Flashing
Sequential
Flashing
Sequential
Flashing
Phase I
Diagram 2
MED
HI
MAX
On
Sequential
Flashing
Sequential
Flashing
Phase II
Diagram 3
MED
HI
MAX
Flashing
On
On
Phase III
Diagram 4
MED
HI
MAX
On On
On
Complete
Diagram 5
MED
HI
MAX
Flashing
Standby
Diagram 1
MED
HI
MAX
Off Off
removed before a complete charge has been reached, the charger will continue indicating the last complete charging phase for up to 1 minute. After that time, and ‘Error’ indication will appear on the LED’s, shown by the MED and MAX LED’s coming on together while the HI LED is off (see diagram 6).
The Error Condition will also be indicated if the charger senses any problem with the battery being charged. To reset the error condition, unplug the charger from the power adapter for a few seconds, then reconnect it to the power adapter. If the Error occurs again, there may be a defect in the battery that will prevent safely charging.
ESTIMATED BATTERY CHARGE TIMES:
BATTERY CAPACITY TIME TO MAX CHARGE*
750 mAh 1200 mAh 1500 mAh 1850 mAh 2400 mAh 3700 mAh 5500 mAh
30 minutes 39 minutes 50 minutes 65 minutes 80 minutes 110 minutes 195 minutes
TROUBLE SHOOTING TIPS:
• Batteries should be replaced when runtime
becomes short.
• If the LED status indicator does not light up when the
charger is plugged into either supplied power adapter,
recheck the connections and make sure that the AC
socket or cigarette lighter has power.
• If the battery is attached, and the status indicator is
showing “Stand By” (indicated by the MED light
flashing and all other lights off), the battery may not be
making proper contact to the adapter plate. Unplug the
unit and check that the battery is attached correctly.
Also, make sure the adapter plate is the proper one and
that it is securely attached to the charger base.
• Use clean dry cloth when necessary to keep the metal
contacts of both charger and battery clean.
CAUTIONS:
• For use with 7.2 Use with other type batteries voids warranty, may cause damage to the charger/battery and possibly cause injury to the user.
• For best battery life, we suggest recharging Li-Ion batteries after use and before storage.
Do not leave battery connected to camcorder or camera when
not in use.
Do not leave the battery connected to the charger for prolonged
• periods. Remove the battery after charge is complete.
• Unplug the charger when not in use.
• Do not use, place or store the charger where it may come into contact with water or moisture.
Always replace frayed or damaged wire and broken plugs immediately.
• Use this charger with the power adapters included in the package only.
• It is not necessary or recommended to discharge a Li-Ion prior to charge.
• No user serviceable parts, opening chassis will void warranty.
Note: Batteries will self discharge when not in use whether they are installed in a camcorder, digital camera or not. Batteries can be kept fresh if you recharge them every 2-3 months.
7.4V Lithium-Ion (Li-Ion) batteries ONLY!
SPECIFICATIONS:
• AC Adapter: 110
• Power Input: 12
• Charge Method: Patented Neotherm Charging Technology
Charge Rate: Variable, Continuously Adjusted via Microprocessor
– 240VAC, 50 / 60Hz – 18 VDC @ 1.7A
visit our web site at: www.energizerbatteries.com or call us at 800-887-2557 For additional questions, comments or to explore other Energizer battery solutions,
the U.S. and Canada, freight will vary depending upon ship to address. handling for addresses in the U. S. and $15.00 in Canada. For outside evidence of date and place of purchase. Enclose $10.00 for shipping and When sending in product for service, your package should include
Indianapolis, IN 46278 6024 W. 79th Street Technuity, Inc.
material to prevent damage in transit and ship it prepaid and insured to: Package the unit and its accessories carefully using ample padding
modifications, or accident. batteries, malfunctions resulting from misuse, tampering, unauthorized repairs, following is excluded:damages from delay or loss of use of equipment, or damaged charge for parts and labor or, at our option, the product will be replaced. The workmanship fails to function properly under normal use, it will be repaired at no thereafter. If, during this period, any part because of manufacturing defects or This limited warranty starts from the date of original purchase and expires 3 years
* Actual charge times may vary depending on the battery, internal protection
circuits, cell capacity and condition.
For 7.2 / 7.4 Volt Li-Ion Batteries Universal Charger for Li-Ion Camcorder and Digital Camera Batteries
PLEASE READ THE INFORMATION AND FOLLOW ALL INSTRUCTIONS THOROUGHLY BEFORE USING THIS PRODUCT.
INTRODUCTION
The ER-CH2 Rapid Charger is a highly advanced and fully automatic battery charger which is compatible with 7.2 / 7.4 Volt Lithium-Ion batteries for camcorders and digital cameras from Sony, Canon, Sharp and Panasonic. The ER-CH2 Rapid Charger features microprocessor controlled Neotherm™ active pulse rapidcharging to charge your battery approximately three times faster than other chargers. Not only will it charge the battery safely and reliably, it will prolong battery life. Charging progress, MAX charge and error conditions are all provided by the LED indicators. Flexible power input allows you to use the ER-CH2 Rapid Charger from home or overseas with its 110V-240V AC Universal Power Supply, or on the road using the DC Cigarette Lighter Adapter included.
OPERATION
Getting Ready
Choose the adapter plate for the type of Li-Ion (Lithium-Ion) battery you will be charging (see Figure 1). Attach the selected adapter plate to the charger unit by aligning the slots on the adapter plate bottom with the fingers on the charger base. While pressing down lightly on the adapter plate, slide the plate toward the front of the charger base until it locks (see Figure 2).
Figure 1
FITS:
ENERGIZER - ER-C535, ER-C540, ER-C557, ER-C735, ER-C745
PANASONIC - CGR-DU07, CGR-DU14, CGR-DU21
SONY - NP-FP50, NP-FP70, NP-FP90
SHARP - BT-L226 SAMSUNG - SB-L70G
FITS:
CANON - BP-508, BP-511, BP-512, BP-522
ENERGIZER - ER-C590, ER-C600
FITS:
ENERGIZER - ER-C520, ER-C544, ER-C545, ER-C571, ER-C640, ER-C610
HITACHI- VM-BPL13A, VM-BPL27A, VM-BP30A, VM-BPL60A
SONY - NP-F550, NP-F750, NP-FM50, NP-FM70, NP-FM90
PANASONIC - VW-VBD1
Figure 2
Plug-in, either the AC Adapter or the DC Cigarette Lighter power adapter, and connect the other end of the power adapter cable to the power input jack on the rear of the charger unit.
Status LED
Together, the three LED will indicate the status of the battery and the charger. See the descriptions and diagrams included in the following sections regarding the various indications and their meaning.
s
s on the front of the ER-CH2 charger
CHARGING YOUR BATTERY
StandBy Mode:
flash the LED on the left, marked MED, indicating that the charger is standing by and waiting for a battery to be connected (see diagram 1).
Once a battery has been properly connected to the appropriate adapter plate, the charger will determine the status of the battery and begin the proper phase of the charging cycle. There are 3 phases to the charge cycle. The battery may be removed during any of the charging phases without harm to the battery or charger unit.
Without any battery installed, the charger will
Phase I – Initial Charge: All 3 LED
MED (left) to MAX (right) (see diagram 2). If the battery is low, this will be the first charge phase. With high capacity batteries, this phase can sometimes be the longest of the 3 phases. Similarly, with some low capacity batteries and batteries reaching the end of their life, this phase can be very short.
Note: When the battery is first connected, the LED’s may instantly indicate MED, HI or MAX charge depending on the charge status of the battery. The process will continue normally from that point forward.
Note: It is normal for the charger, AC adapter, or the battery to become warm during charging.
Phase II – MED Charge:
and other LED’s are flashing in sequence (see diagram 3). At this point the battery is typically about 50% charged. Some very small capacity batteries (650mAh) and worn out batteries can be as low as 10% charged.
HI Charge:
Phase III
MAX LED is flashing (see diagram 4). At this point the battery is typically, about 70% charged.
The MED and HI LED
Charge Complete – MAX Charge: All three LED’
the same time (see diagram 5). Charging has completed and the battery is fully charged. It is recommended to remove the battery at this time.
s flashing in sequence from
The MED LED is on continuously
’s are on and the
s are on at
Loading...