Energizer EN180 User Manual

WARNING:
This Unit employs Components that tend to produce arcs or sparks – To prevent fire or explosion, do not install in compartments containing batteries or flammable materials - SHOCK HAZARD. DO NOT OPEN.
CAUTION:
OUTPUT NON-SINUSOIDAL REFER TO MANUAL - Provided with integral protection against overloads. To prevent fire, do not cover or obstruct ventilation openings. Do not mount in Zero-Clearance compartment. Overheating may result.
Notice :
The output of this device is not sinusoidal. It has a total harmonic distortion of 30% percent and maximum single harmonic of 8 percent
Toll Free 1 866 295 6775
ww
w.energizerpower.com
Printed in China
EN120 EN180
Owner's Guide
Confor ms to / Confor me à U L std. 458,
CSA s td. C22 .2 No. 1 07.1
1 Introduction
Thank you for purchasingthe Connected to the 12 volt outlet in your vehicle, the
EN120/180
of loads through both the AC outlet and USB port. Read this guide before connecting or using the
EN120/180
We hope you enjoy using your and if you require any assistance, please contact our help desk:
www.energizerpower.com or toll free: 1.866.295.6775
efficiently and reliably powers a wide variety
and save it for future reference.
Energizer
EN120/180
® EN120/180
2 Important Safety Information
Misusing or incorrectly connecting the may damage the equipment or create hazardous conditions for users. Read the following safety instructions and pay special attention to all Caution and Warning statements in the guide.
Warnings identify cond itions that may result in
Cautions identify conditions or practices that may
damage the unit or other equipment.
WARNING
Keep children away from the . The
nverter generates the same potentially lethal AC
i power as a normal household wall outlet.
EN120/180
EN120/EN180
1
Warnings and Cautions
The housing may become
EN120/EN180
uncomfortably warm, reaching140° F (60° C) under extended high power operation. During operation, keep it away from materials that may be affected by high temperatures.
Do not use the in the presence of flammable fumes or gases, such as in the bilge of a gasoline powered boat, or near propane tanks. Do not use the in an enclosure containing automotive-type, lead-acid batteries. These batteries, unlike sealed batteries, vent explosive hydrogen gas, which can be ignited by sparks from electrical connections.
WARNING: Shock hazard
Use caution when inserting an AC plug into the three-prong AC outlet. The prongs of an AC plug can become bent from misuse. If an AC plug is improperly inserted into the AC outlet, a bent prong can slip outside the inverter and become a shock hazard. Grip the inverter carefully when inserting or removing an AC plug. Keep your ngers clear of the AC outlet. Ensure that your ngers do not contact the prongs of an AC plug when the plug is partially inside the inverter.
2
EN120/EN180
EN120/EN180
CAUTION: Risk of Fire.
Do not replace any vehicle fuse with a rating higher than recommended by the Vehicle Manufacturer. Ensure that the electrical system in your vehicle can supply this product without causing the vehicle
fusing to open. rating is typically found in the vehicle operator’s manual. If a vehicle fuse opens repeatedly, do not keep on replacing it. The cause of the overload must be found.
On no account should fuses be patched up with tin foil or wire as this may cause serious damage
elsewhere in the electrical circuit or
Information on the vehicle fuse
3
CAUTION: Output non-sinusoidal
Some chargers for small nickel-cadmium batteries can be damaged if connected to the Do not use the inverter with the following appliances:
Small battery-operated appliances like rechargeable flashlights, some rechargeable shavers, and night lights that are plugged directly into an AC receptacle to recharge.
Battery chargers used in hand power tools. These chargers display a warning label stating that dangerous voltages are present at the charger battery terminals.
EN120/EN180
CAUTION
Do not connect live AC power to the AC outlets. This will damage the inverter, and the damage is not covered by warranty. Do not connect any AC load that has its neutral conductor connected to ground to the
EN120/EN180
EN120/EN180
4
Additional Safety Guidelines
Do not insert foreign objects in the
EN120/EN180
Never connect the inverter to power utility AC distribution wiring.
Do not use the over 100° F (40° C).
Do not expose the snow, or spray.
Failure to follow these safety guidelines may cause personal injury and/or damage to the
It may also void your product warranty.
outlets or other openings.
EN120/EN180
EN120/EN180
in temperatures
to water, rain,
EN120/EN180
3 Safety Features
Overload protection with automatic shutdown
Low battery voltage shutdown
High-input voltage protection with automatic shutdown
Overheat protection with automatic shutdown
Output short circuit protection.
5
4 Inverter Features
EN120/180
USB ports
2.1 Amp
(shared)
LED Light indicator
DC Connector
AC Outlet
Ventilation opening
6