1.1 Key Features ....................................................................................................................................... 3
3.2 General Specifications ........................................................................................................................ 5
3.3 Power Supply ...................................................................................................................................... 6
3.4 Radio Transmitter Specifications ........................................................................................................ 6
3.5 Radio Receiver Specifications ............................................................................................................. 7
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
Page
3
1 Introduction
Parameter
Min Typ Max
Units
Notes
Dimensions (L)
43.6 mm
Dimensions (W)
29.3 mm
Dimensi
ons (T)
5.1 mm Total thickness.
This document is the User Manual for the Energate ZRM10 Radio Module. This Radio
Module can be integrated into any number of products that require wireless connectivity using the
ZigBee protocol.
1.1 Key Features
• Utilizes Ember EM250 ZigBee System-on-a-Chip (SoC)
• RF Performance Optimized and Guaranteed
− Frequency: 2405-2480MHz (ZigBee Ch11 to 26)
− Data Rate: 250kb/s
− Transmit Power: 100mW (Typical)
− Receiver Sensitivity: -95dBm (Typical) for PER=1%
• Small Form Factor
• 17 GPIO Connections
• Supply Voltage: +3.3 VDC (Typical)
• Operating Temperature: -40 to 85 °C
• PCB Mount Chip Antenna: +1.5dBi (Peak Gain)
2 Mechanical Specifications
2.1 General Mechanical Specifications
2.2 28-pin Connector Specifications
The 28-pin connector that is used on the Energate ZRM10 Radio Module is the Samtec FTS-114-03L-DV.
Below is the pin-out of the Radio Module.
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
Page
4
Pin Signal
Function
Secondary
Comment
1 VBRD
+3.3V supply to the ZRM10.
2 VBRD
+3.3V supply to the ZRM10.
3 GPIO_1
MISO (SPI)
SDA (
I2C)
Connected to SPI Flash (DOUT) on
the
module.
4 GPIO_2
MSCLK (SPI)
SCL (
I2C)
Connected to SPI Flash (CLK) on
the
module.
5 GPIO_12
6 GPIO
_0 MOSI (SPI)
Connected to SPI Flash (DIN) on
the
module.
7 GPIO_3
8 GPIO_11
/CS
Connected to SPI Flash (/CS) on
the
module.
9 GPIO_5
ADC1
10 GPIO_4
ADC0
11 GPIO_7
LED ADC3
Connected to LED D1 on the module. D1 is currently NO
12 GPIO_
6 ADC2
13 GPIO_9
TXD
UART connection to EM250.
14 GPIO_8
15 RSTB
RSTB
16 GPIO_10
RXD
UART connection to EM250.
17 GND
18 GND
19 SIF_CLK
20 SIF_MISO
21 SIF_MOSI
22 SIF_LOADB
Function
POP.
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
Page
5
Pin Signal
Function
Secondary
Function
Commen
t
23 GPIO_16
24 GPIO_15
/WP
Connected to SPI Flash (/WP) on
the
module.
25 GPIO_14
26 GPIO_13
27 GND
28 GND
Parameter
Min Typ Max
Units
Notes
Operating Frequency
2405
2483.5
MHz
RF data rate
250
kb/s
Ambient operating
-40
+24 +85 °C
Regulatory Compliance
FCC Part15 (Sub C)
Full modular
Indu
stry Canada RS
-
210 (Issue7)
3 Radio Interface Specifications
3.1 Introduction
The following section describes the radio specifications for the ZRM10 Radio Module. The design
utilizes an Ember EM250 ZigBee System-on-a-chip (SoC) to provide wireless connectivity using the IEEE
802.14.5a protocol. The EM250 is connected to an external RF power amplifier which boosts the
transmitted RF signal power to 100mW (Typ).
3.2 General Specifications
Temperature
approval.
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
Page
6
3.3 Power Supply
Parameter
Min Typ Max
Units
Notes
Voltage
3.1 3.3 3.5 V
Current, Tx
185 mA
Conditions:
Current, Rx
38 mA
Current, Idle/Napping
8.5 mA
Current, Standby
5 µA
Parameter
Min Typ Max
Units
Notes
Transmit Output Power
20 dBm
100mW (Typ)
Transmitter LQI
255
Transmit frequenc
y offset
-10 10 ppm
As measured with a
Transmit frequency offset
-40 40 ppm
1) Pout=+20dBm
(100mW)
2) Vcc=+3.3V
3.4 Radio Transmitter Specifications
The RF transmitter power is +20dBm (100mW) for the Channels 11 through 25. Due to
requirements specified in FCC Regulations (Part 15, Restricted Frequency Bands), the RF transmit power is
reduced for Channel 26 (2480 MHz).
(2405-2475MHz, Ch11-Ch25)
(24C)
CW tone at the
transmitter output.
(-40C to +85C)
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
Page
7
3.5 Radio Receiver Specifications
Parameter
Min Typ Max
Units
Notes
Receiver maximum input
0 dBm
Receiver sensitivity
-95
dBm
Parameter
Min Typ Max
Units
Notes
Antenna Gain (Peak)
1.5
dBi
Antenna Gain (Average)
-
2.3
dBi
Radiation Efficiency
70 %
signal (PER=1%)
(PER=1%)
3.6 Antenna Specifications
The antenna used on the ZRM10 is a chip antenna with these specifications:
(Average)
NOTE: When integrating the Energate ZRM10 Radio Module into other products, only the antenna
provided on the Radio Module can be used. If any other antenna is used, this is a violation of FCC and
Industry Canada regulations.
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
Page
8
4.0 Regulatory Requirements (FCC and IC)
Contains
FCC ID: WUR
-
ZRM10
IC ID: 8022A
-
ZRM10
The Energate ZRM10 Radio Module device complies with FCC (Part 15) and Industry Canada (RS-
210) regulatory requirements. Operation of the ZRM10 is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause
undesired operation.
The Energate ZRM10 Radio Module can be integrated into a variety of different products. With this
in mind, the ZRM10 has obtained Full Modular Approval from both the FCC and IC. This approval means
that the ZRM10 is designed in such a way that it is a self-contained entity. The ZRM10 can then be attached
to ANY product without any further testing by the FCC or IC for (radio) regulatory compliance in the 2400-
2483.5MHz band.
4.1 RF Exposure Warning
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This device must be installed in accordance with the provided instructions and must be
operated with minimum 20 cm spacing between the antennas and any person’s body during wireless mode
of operation. Further, this transmitter must not be collocated and operated in conjunction with any other
antenna or transmitter.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
4.2 Labelling Requirements
When integrating the Energate ZRM10 Radio Module into other products, the following
requirements must be met:
1. Use only the antenna provided.
2. Operate the module according to the specifications listed in this User Manual.
3. Include a label clearly visible on the exterior of the end product which states:
NOTE: It is mandatory that end users of the Energate ZRM10 consult all FCC and IC documentation for use of
a product with modular approval, and ensure any products comply with all listed guidelines and additional
testing that may be required.
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.