follow all instructions. Place instructions in a
safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
FORCED AIR PROPANE
CONSTRUCTION HEATER
HEATSTAR
MODEL
HS35FA
WARNING:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
— An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appli-
ance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light appliance.
• Extinguish any open ame.
• Shut off gas to appliance.
— Service must be performed by a qualified service agency.
This is an unvented gas-red portable heater. It uses air (oxygen) from the area in which it is used.
Adequate combustion and ventilation air must be provided. Refer to page 3.
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
70036 Rev. E 4/09ENERCO GROUP, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
WARNING:
The State of California requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN US-
ING THIS PRODUCT CONTAIN CARBON MONOXIDE,
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER
REPRODUCTIVE HARM).
Enerco Group, Inc. | Forced Air Propane Construction HeaterOperating Instructions and Owner’s Manual
2
OPERATING PRECAUTIONS
This is a propane, direct-red, forced air heater. It's intended use
is primarily temporary heating of buildings under construction,
alteration or repair.
Propane is heavier than air. If propane leaks from a connection or
tting, it sinks to the oor, collecting there with the surrounding
air, forming a potentially explosive mixture. Obviously, propane
leaks should be avoided, so set up the propane supply with utmost
care. Read enclosed Odor Fade and Propane Sheet for additional
information about detecting propane leaks. Leak check new
connections or reconnections with a soap and water solution and
follow all connection instructions herein. Also, ask your propane
dealer for advice on the propane application and supply installation
and ask him to check it if there are any questions.
This heater was designed and certied for use as a construction
heater in accordance with ANSI Standard Z83.7/CGA 2.14. Check
with your local re safety authority if you have any questions about
your applications. Other standards govern the use of fuel gases and
heat producting products in specific applications. Your local authority
can advise you about these.
Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to 100
percent combustion efficiency, it still produces small amounts of
carbon monoxide. Carbon monoxide (called CO) is toxic. We can
tolerate small amounts but not a lot. CO can build up in a heated
space and failure to provide adequate ventilation could result in
death. The symptoms of inadequate ventilation are:
• headache
• dizziness
• burning eyes and nose
• nausea
• dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating
instructions.
Forced Air means that a blower or fan pushes the air through the
heater. Proper combustion depends upon this air ow; therefore,
the heater must not be revised, modied or operated with
parts removed or missing. Likewise, safety systems must not be
circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people
the user is responsible for properly acquainting those present with
the safety precautions and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
2. DO NOT modify the heater or operate a heater which has been
modified from its original condition.
3. Use only propane gas.
4. Use only VAPOR WITHDRAWAL propane supply. If there is any
question about vapor withdrawal, ask your propane dealer.
5. Mount the propane cylinders vertically (shutoff valve up).
Secure them from falling or being knocked over and protect
them from damage.
6. Locate propane containers at least (USA) 7 ft. (2.13m), (Canada)
10 ft. (3m) from the heater and do not direct exhaust toward
containers.
7. IMPORTANT Use only the hose and regulator assembly
provided with the heater. Match the color stripe on the
hangtag attached to the hose assembly with the color on
the label located near the propane inlet fitting on the heater.
Inspect hose assembly before each use of the heater. If there
is excessive abrasion or wear, or hose is cut, replace with hose
assembly listed on parts list before using heater.
8. For indoor use only. Area must be well ventilated. Provide
minimum openings of 1/2 sq. ft. (.046 m²) near the oor
and 1/2 sq. ft. (.046 m²) near the ceiling (also see "Operating
Precautions").
9. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor fade and Propane
Sheet for additional information about detecting propane leaks.
10. Install the heater such that is is not directly exposed to water
spray, rain and/or dripping water.
11. Maintain minimum clearance from normal combustible material
(like paper) as follows: oor-0 ft. (0 m); outlet-6 ft. (1.83m);
sides-2 ft. (.61m); top-6 ft. (1.83m). Locate 10 ft. (3m) from
canvas or plastic tarpaulins or similar coverings and secure them
to prevent apping or movement due to wind action.
12. Due to the high surface and exhaust temperatures, adults and
children must observe clearances to avoid burns or clothing
ignition.
13. Operate only on a stable, level surface.
14. Do not use with ductwork. Do not restrict inlet or exit.
15. Use only the electrical power specied. The electrical
connection and grounding must comply with National Electrical
Code - ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical
Code, Part 1 (Canada).
16. Use only a properly grounded 3-prong receptacle or extension
cord (6 ft (1.83m) in length minimum).
17. Do not move, handle or service while hot or burning.
18. Use only in accordance with local codes or, in the absence of
local codes, with the Standard for the Storage and Handling
of Liqueed Petroleum Gases ANSI/NFPA 58 and CSA B149.1,
Natural Gas and Propane Installation Code.
Enerco Group, Inc. | Forced Air Propane Construction HeaterOperating Instructions and Owner’s Manual
3
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
• Do not use this heater for heating human living
quarters.
• Do not use in unventilated areas.
• The ow of combustion and ventilation air must not
be obstructed.
• Proper ventilation air must be provided to support
the combustion air requirements of the heater
being used.
• Refer to the specication section of the heater’s
manual, heater dataplate, or contact the factory to
determine combustion air ventilation requirements
of the heater.
• Lack of proper ventilation air will lead to improper
combustion.
• Improper combustion can lead to carbon monoxide
poisoning leading to serious injury or death.
Symptom of carbon monoxide poisoning can
include headaches dizziness and difficulty in
breathing.
ODOR FADING - NO ODOR DETECTED
• Some people cannot smell well. Some people cannot smell
the odor of the man-made chemical added to propane (LP)
or natural gas. You must determine if you can smell the
odorant in these fuel gases.
• Learn to recognize the odor of propane (LP) gas and
natural gas. Local propane (LP) gas dealers will be more
than happy to give you a scratch and sniff pamphlet. Use it
to become familiar with the fuel gas odor.
• Smoking can decrease your ability to smell. Being around
an odor for a period of time can affect your sensitivity to
that particular odor. Odors present in animal confinement
buildings can mask fuel gas odor.
• The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under
some circumstances.
• If there is an underground leak, the movement of gas
through the soil can filter the odorant.
• Propane (LP) gas odor may differ in intensity at different
levels. Since Propane (LP) gas is heavier than air, there may
be more odor at lower levels.
•Alwaysbesensitivetotheslightestgasodor.If you
continue to detect any gas odor, no matter how small, treat
it as a serious leak. Immediately go into action as discussed
previously.
FUEL GAS ODOR
LP gas and natural gas have man-made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel
gas. Since Propane (LP) is heavier than air you should
smell for the gas odor low to the floor. ANY GAS ODOR
IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
• Do not take any action that could ignite the fuel gas. Do
not operate any electrical switches. Do not pull any power
supply or extension cords. Do not light matches or any
other source of flame. Do not use your telephone.
• Get everyone out of the building and away from the area
immediately.
• Close all propane (LP) gas tank or cylinder fuel supply
valves, or the main fuel supply valve located at the meter if
you use natural gas.
• Propane (LP) gas is heavier than air and may settle in low
areas. When you have reason to suspect a propane leak,
keep out of all low areas.
• Use your neighbor’s phone and call your fuel gas supplier
and your re department. Do not re-enter the building or
area.
• Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas supplier.
• FINALLY, let the fuel gas service person and the reghters
check for escaped gas. Have them air out the building and
area before you return. Properly trained service people
must repair any leaks, check for further leakages, and then
relight the appliance for you.
ATTENTION - CRITICAL POINTS TO
REMEMBER!
• Propane (LP) gas has a distinctive odor. Learn to recognize
these odors. (Reference Fuel Gas Odor and Odor Fading
sections above.
• Even If you are not property trained in the service and
repair of the heater, ALWAYS be consciously aware of the
odors of propane (LP) gas and natural gas.
• If you have not been properly trained in repair and service
of propane (LP) gas then do not attempt to light heater,
perform service or repairs, or make any adjustments to the
heater on the propane (LP) gas fuel system.
• A periodic sniff test around the heater or at the heater’s
joints; i.e. hose, connections, etc., is a good safety practice
under any conditions. If you smell even a small amount of
gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY.
DO NOT WAIT!
Enerco Group, Inc. | Forced Air Propane Construction HeaterOperating Instructions and Owner’s Manual
4
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is found,
immediately notify the factory.
2. Follow all of the "Precautions".
3. Connect the POL fitting of hose and regulator assembly to the
propane cylinder by rotating the POL nut counterclockwise into
the propane cylinder's valve outlet and securely tighten with a
wrench.
4. Connect the hose to the heater by rotating the hose fitting
clockwise.
5. Securely tighten all gas connections.
6. Open the cylinder's gas valve and check all gas connections with
a soap and water solution. DO NOT USE A FLAME.
7. Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of
power.
8. When using an extension cord, make certain that it is a 3-wire
(grounded) cord of proper wire size, minimum length of 6 ft
(1.83m).
START
1. THE HEATER POWER CORD MUST BE CONNECTED TO
A GROUNDED 115V, 60HZ, 1Ø POWER SOURCE BEFORE
HEATER IGNITION and always allow heater fan (blower) to run
for 20 seconds to purge fuel.
2. Open propane supply valve on propane tank slowly. Note: If not
opened slowly, excess-ow check valve on propane tank will stop
gas ow. If this happens, close propane supply valve and open
again slowly. Wait 15 seconds before Step 3.
3. Push and hold automatic control valve button. Push piezo ignitor
button repeatedly until the burner lights.
4. After the burner lights, keep the gas valve button depressed for
30 seconds then release and the heater will continue to operate.
WARNING: Be sure motor and fan are running before pushing
in automatic control valve button. Flames could flash outside
heater or internal damage to heater may result if motor and fan
are not running.
STOP
1. Securely close valve on the propane cylinder.
2. Continue to operate heater until all fuel in the hose has burned.
3. Unplug the power cord.
CAUTION: Always shut off fuel supply before disconnecting
electrical power.
MAINTENANCE AND STORAGE
1. The heater should be inspected before each use, and at least
annually by a qualified person.
2. Before each use, check the soft "O" ring seat at the bullnose
of the POL tting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number 6681.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater
is not in use.
4. When the heater is to be stored indoors, the connection
between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the heater
and stored out of doors and in accordance with Chapter 5 of
the standard for Storage and Handling of Liquefied Petroleum
Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane
Installation Code.
SERVICING
A hazardous condition may result if a heater is used that has been
modied or is not functioning properly. When the heater is working
properly:
* The ame is contained within the heater.
* The ame is essentially blue with perhaps some yellow tipping.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the
heater.
The parts lists and exploded view show the heater as it was
constructed. Do not use a heater which is different from that shown.
In this regard, use only the hose, regulator and cylinder connection
tting (called a POL tting) supplied with the heater.
Match the color stripe on the hangtag attached to the hose assembly
with the color on the label located near the propane inlet tting on
the heater. Do not use alternates. For this heater, the regulator must
be set as shown in "specications". If there is any uncertainty about
the regulator setting, have it checked.
A heater which is not working right must be repaired, but only by a
trained, experienced service person.
In-warranty products will be repaired with no charge for either parts
or labor. Please include a brief statement indicating date, place of
purchase, the nature of the problem and proof of purchase.
Out-of-warrranty products will be repaired with a charge for parts and
labor.
IMPORTANT
RESTART AFTER SAFETY SHUTDOWN
1. Securely close valve at propane cylinder. Unplug power cord.
2. Wait 5 minutes.
3. Restart following "START" procedure.
Enerco Group, Inc. | Forced Air Propane Construction HeaterOperating Instructions and Owner’s Manual
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.