Enerco 4000DF, 6000DF User Manual

OPERATING INSTRUCTIONS AND OWNER’S MANUAL
MR. HEATER
MODEL
4000DF 6000DF 4000DF 6000DF
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
HEATSTAR
BY ENERCO
MODEL
DIRECT FIRED PORTABLE HEATER
WARNING:
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
— Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to page 5.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX­IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MA­TERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN­KNOWN CHEMICALS.
WARNING:
The State of California requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN US-
ING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).
WARNING:
READ THE INSTRUCTIONS GIVEN IN THIS MANUAL BEFORE USING THE APPLIANCE.
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUELS.
• THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE
IS CONNECTED MUST COMPLY WITH ALL SAFETY REGULATIONS IN FORCE. A RESIDUAL CURRENT CIRCUIT BREAKER MUST BE PROVIDED ON THE MAIN DISTRIBUTION BOARD.
• UNPLUG THE HEATER BEFORE ATTEMPTING ANY
SERVICE OR MAINTENANCE.
• ALWAYS CHECK THE POWER SUPPLY CABLE BEFORE
USE. IT MUST NOT BE BENT, CRUSHED, OR ANYWAY DAMAGED.
• THE POWER SUPPLY CABLE MUST BE REPLACED ONLY
BY QUALIFIED PERSONNEL.
• ONLY USE AN ORIGINAL H07RN-F POWER CABLE
WITH WATERPROOF PLUG.
CONTENTS
WARNINGS .................................................................................. 2
SPECIFICATIONS ........................................................................... 3
OPERATION ................................................................................. 4
SAFETY DEVICES .......................................................................... 4
MAINTENANCE ............................................................................ 5
TROUBLESHOOTING ....................................................................6
WIRING DIAGRAMS ..................................................................... 7
PARTS LIST ................................................................................... 8
• DO NOT TOUCH THE EXHAUST GAS OUTLET. DANGER
OF BURNS!
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
2
IMPORTANT
Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS
The direct-red heater runs on diesel fuel. This direct combustion
heater exhausts hot air and the combustion products into the room, while those with indirect combustion are fitted with a flue to take the fumes away through the chimney.
Always follow local ordinances and codes when using this
heater:
• Read and follow this owner’s manual before using the
heater.
• Use only in places free of ammable vapors or high dust
content.
• Never use heater in immediate proximity of ammable
materials (the minimum distance must be 6 ft.).
• Make sure re ghting equipment is readily available.
• Make sure sufcient fresh outside air is provided according
to the heater requirements. Direct combustion heaters should only be used in well vented areas in order to avoid carbon monoxide poisoning.
• Never block air inlet (rear) or air outlet (front).
• In case of very low temperatures add kerosene to the
heating oil.
• Make sure heater is always under surveillance and keep
children and animals away from it;
• Before starting the heater always check free rotation of
ventilator fan.
• Unplug heater when not in use.
TECHNICAL SPECIFICATIONS
Heat input [kBTU/h] 400 610 Air flow [cfm] 2.500 2.800 Fuel Type Diesel/Kerosene/#1-2 Fuel Oil Heat output [kBTU/h] - -
Fuel consumption
Phase 1 1
Power supply
Electric consumption
Nozzle [USgal/h] 2.00-30° S 3.00-80°S Pump pressure [psi] 174 217 Max static pressure [in WC] - ­Recommended max. temp. in the air
duct
Adjustment of combustion air flap
Flue diameter [in] - ­Compulsory flue draft [in WC] - ­Tank capacity [gal] 27.7 35.7 Dimensions, L x W x H [in] 62.4x27.6x39 67.9x27.6x41.2 Net Weight [lb] 222 246
Voltage [V] 12 0 12 0 Frequency [Hz] 60 60
[gal/h] 12.83 4.46
[lb/h] 19.58 30.84
[W] 1,170 1,040
[A] 8.30 10.50
[°F] - -
[in] a=0.59 a=1.00
- -
MH 4000DF
HS 4000DF
MH 6000DF
HS 6000DF
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
3
OPERATION
Before any attempt of starting the heater is made, check that your electrical supply conforms to the data on the model plate.
Control Board
1 4
1 RESET BUTTON WITH CONTROL LAMP 2 CONTROL LAMP 3 MAIN SWITCH 4 ROOM THERMOSTAT PLUG 5 POWER CORD
Gap of Electrodes
3 2
O N
0
O N
X
Y
Z
• Install the heater on a at, level oor in a steady position.
• It is forbidden to connect direct-red heaters to air ducts.
WARNING
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS.
• STOP HEATER BEFORE ADDING FUELS.
5
• ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
• DO NOT USE EXTERNAL FUEL SOURCE.
• DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS
OR VAPORS MAY BE PRESENT.
• DO NOT START HEATER WHEN CHAMBER IS HOT
• DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMU-
LATED IN THE CHAMBER.
• DO NOT PLACE COOKING UTENSILS ON TOP OF THE
HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
The generator can only work automatically when a control device, such as for example a thermostat or a timer, is connected to the generator. Connection to the generator is made by removing the socket cover(4) and inserting the thermostat plug.
To start the machine you must:
•If connected to the thermostat, turn the switch to (ON +
•If not connected to the thermostat, turn the switch to (ON).
When unit is started for the first time or is started after the oil tank has been totally emptied, the flow of oil to the burner may be impaired by air in the circuit. In this case the control box will cut out the heater and it might be necessary to renew the starting procedure once or twice by depressing the reset button (1).
Should the heater not start, check that oil tank is full and depress reset button (1).
Should the heater still not work, please refer to chapter “OBSERVED FAULTS, CAUSES AND REMEDIES”.
);
STOPPING THE HEATER
Set main switch (3) on “0” position or turn thermostat or other control device on lowest setting.
The flame goes out and the fan continues to work for approx. 90sec. cooling the combustion chamber.
Models X Y Z 4000 DF 6000 DF
Clearances
The following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured:
Sides 2.5 ft. Air Inlet 2.5 ft. Top 6 ft. Air outlet 12 ft.
• Floors and ceilings must be made of reproof materials in
the room where the heater is operated.
• The air inlet and outlet must never be blocked for any
reason.
0.157 in 0.098 in 0.157 in
0.157 in 0.098 in 0.157 in
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
SAFETY DEVICES
The unit is fitted with an electronic flame control box. In case of malfunction this box will cut in and stop the heater, at the same time the pilot lamp in the control box reset button (1) will light up.
Heaters are also equipped with an overheat thermostat safety cutout which will stop the heater in case of overheating. This thermostat will reset automatically but you will have to depress button (1) on control box before being able to restart the heater.
TRANSPORT
WARNING
• Before making any attempt to restart heater nd and elimi-
nate reason of overheating.
Before heater is moved it must be stopped and unplugged. Before moving the heater wait till it has totally cooled off and make sure oil tank cap is securely fixed.
4
The hot air generators with wheels must be wheeled. The suspended version which has no wheels must be transported with adequate machinery.
MAINTENANCE
Preventive and regular maintenance will ensure a long trouble free life to your heater.
WARNING
• Never service heater while it is plugged in, operating or hot.
Severe burns or electrical shock can occur.
Every 50 hours of operation: disassemble filter and wash with clean oil, remove upper body parts and clean inside and ventilator with compressed air, check correct attachment of H.V. connectors to the electrodes and check H.V. cables, remove burner assembly, clean and check electrode settings, adjust according to scheme “GAP OF ELECTRODES”.
COLUMN INTENTIONALLY LEFT BLANK
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
5
TROUBLESHOOTING
TROUBLE CAUSE SOLUTION
Motor does not start, no ignition
No electrical current Check mains (should be 120 V – 1~ – 60 Hz)
Check proper positioning and functioning of switch
Check fuse
Motor starts, no ignition or cuts out
Motor starts, heater emits smoke
Heater does not stop
Wrong setting of room ther­mostat or other control
Thermostat or other control defective
Electrical motor defective Replace electrical motor
Electrical motor bearings defective
Burned out condenser Replace condenser
Electric ignitor defective Check connection of H.V. Ieads to electrodes and transformer
Flame control box defective Replace control box
Photocell defective Clean or replace photocell
Not enough or no fuel at all at burner
Solenoid defective Check electrical connection
Not enough combustion air Make sure air inlet and outlet are free
Too much combustion air Check setting of combustion air flap
Fuel contaminated or con­tains water
Air leaks in fuel circuit Check the seals on the ducts and the diesel filter
Not enough fuel at burner Check pump pressure
Too much fuel at burner Check pump pressure
Solenoid Replace solenoid coil or complete solenoid
Check correct setting of heater control. If thermostat, make sure selected temperature is higher than room temperature
Replace control device
Replace electrical motor bearings
Check electrodes setting (see scheme “GAP OF ELECTRODES”)
Check electrodes for cleanliness
Replace H.V. transformer
Check state of motor-pump plastic coupling
Check fuel line system including fuel filter for possible leaks
Clean or replace oil nozzle
Check thermostat LI
Clean or replace solenoid
Check setting of combustion air flap
Clean burner disc
Drain fuel in tank with clean fuel
Clean oil filter
Clean or replace fuel nozzle
Replace nozzle
If heater still not working properly, please revert to nearest authorized dealer.
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
6
Loading...
+ 14 hidden pages