Endura GREASE MANAGEMENT User Manual

Eective Date: June 1, 2018
GREASE MANAGEMENT
Engineering grease
management solutions
for plumbing and
ENDURA SECTION 22 13 23 GREASE INTERCEPTORS
food service professionals
tech-support@endurainterceptor.com
About Us
Molding a Better Future
We are one of North America’s leading producers of plastic products for the building and construction industries specializing in injection molded products. We have ve decades of expertise and experience in the manufacturing and distribution of plastic plumbing products, processing multiple materials and producing millions of ttings and products on an annual basis.
Endura® grease management products have demonstrated eective, ecient and consistent performance with over a decade of eld installation and operation. The Endura® products are multi-patented and built to withstand the toughest environments, providing the exibility of in-oor, on-oor and semi-recessed application. We have been instrumental in changing the traditional practices regarding the installation of grease management solutions, plastic alternatives to metal interceptors being now substantially accepted Nationwide as the new standard for grease management in commercial foodservice applications.
Endura® Earth friendly solutions for Grease Management
We are committed to the continuous improvement of our environmental performance and to meeting or exceeding the requirements of all applicable environmental laws and regulations.
Durability
• Fewer installations and replacements result in lower lifetime costs & less landll waste
• Injection molded in engineered thermoplastics, Endura® Grease Interceptors will not corrode, chip, or peel, even under the most severe applications
• Durability provides consistent operation – no compromise of eectiveness due to deterioration of key parts
Green by Design
• Light-weight but durable grease interceptor units enable smaller carbon footprints and low-emissions transport
• Injection and rotationally molded thermoplastic requires less energy to produce than metal grease interceptors
• Endura® interceptors are manufactured using up to 100% recompounded material
Product Overview
Hydromechanical Grease Interceptors (HGI)
Endura® 7 - 10 Models
3907A02 - 7GPM (0.44 LPS) 2” (51 mm) connection 3910A02 - 10GPM (0.63 LPS) 2” (51 mm) connection
Compact models use a development of the patented Endura bae system to enhance separation performance at low ow rates. EZ-Clean tank design – Aids exterior cleaning.
Endura® 15 - 20 Models
3915A02 - 15GPM (0.94 LPS) 2” (51 mm) connection 3920A02 20GPM (1.26 LPS) 2” (51 mm) connection
Our original tank, 15 and 20gpm units are perhaps the most commonly installed product. It suits both on-oor and in-oor applications.
Endura® 25 Lo-PRO Model
3925A02LO 25GPM (1.6 LPS) 2” (51 mm) connection
Endura® Lo-PRO is for tight on-oor applications where space is at a premium. Same dimensional footprint as 35gpm and 50gpm Endura® models. Overall height 11 inches, still meeting requirements of ASME112.14.3. Internal components can be removed in less than 5” of additional clearance.
Endura® 25 XT Models
3925XTA02 25GPM (1.6 LPS) 2” (51 mm) connection 3925XTA03 25GPM (1.6 LPS) 3” (76 mm) connection
25gpm uses structured foam molding technology providing rigidity and durability while reducing unit weight. Models incorporate cover pry points and latch recesses for no-tool access.
Endura® 35 Models
3935A03 35GPM (2.2 LPS) 3” (76 mm) connection
3935A04 35GPM (2.2 LPS) 4” (110 mm) connection
35gpm is constructed of thermoplastics providing rigidity and durability while reducing unit weight. Diuser bae aids separation at increased ow rates.
Endura® 50 Models
3950A03 50GPM (3.2 LPS) 3” (76 mm) connection 3950A04 50GPM (3.2 LPS) 4” (110 mm) connection
A tall version of our 35gpm model the 50gpm interceptor uses common parts incorporating all the best features of the Endura® product design in a comparatively light weight solution to that of its metal competitors.
High Capacity Hydromechanical Grease Interceptors (HGI)
Endura®XL 75 Models
4075A04 75 GPM (4.74 L/Sec) 4”(110 mm) Connections 4075A04T 75 GPM (4.74 L/Sec) 4”(110 mm) FPT Connections
Industry leading separation eciency based on testing to national standards. Comparable operational grease capacity (580 lb) to 750 gallon Gravity GI (Concrete).* Operation is based on Dynamic Inlet Bae (Pat. Pend.) with internal ow control device. Smart tank design oers many features, with external ow control available as an option. Cut-to-length riser system for burial up to 72”, pre-plumbed outlet system, trac rated dual cover format for unrivalled maintenance accessibility & inspection.
Endura®XL 100 Models
40100A04 – 100GPM (6.3 L/Sec) 4”(110 mm) Connections 40100A04T - 100GPM (6.3 L/Sec) 4”(110 mm) FPT Connections
Industry leading separation eciency based on testing to national standards. Comparable operational grease capacity (1058 lb) to 1000 gallon Gravity GI (Concrete).* Operation is based on Dynamic Inlet Bae (Pat. Pend.) with internal ow control device. Smart tank design oers many features, with external ow control available as an option. Cut-to-length riser system for burial up to 72”, pre-plumbed outlet system, trac rated dual cover format for unrivalled maintenance accessibility & inspection. * based on 25% rule for maintenance
Grease Interceptors – Generic Types
The grease management industry has developed signicantly in the past decade with not only more advanced and improved products but also development of performance standards and harmonization of common terms and references.
Traditionally the term “Grease Trap” was commonly applied and is still used in the industry today. This term is progressively disappearing from nomenclature and technical references based on an industry wide recognition that the term “trap” would suggest the presence of a water seal, integrally located within the interceptor. This practice substantially ceased many years ago, modern interceptors being designed to be installed in conjunction with external water seal traps as a standard part of the system.
In addition to this clarication, with publication of the 2006 UPC plumbing code three generic types of Grease Interceptor were introduced and have since become the industry standard for designating the type of interceptor being considered.
Generically the application of a Grease Interceptor regardless of type is dened as follows:
Grease Interceptor: “A plumbing appurtenance or appliance that is installed in
a sanitary drainage system to intercept nonpetroleum fats, oil, and grease (FOG) from a wastewater discharge.
Specic characteristics then dene the three types of Interceptor:
Hydromechanical Grease Interceptor (HGI)
“An HGI is sized by ow rate (GPM) and qualied separation/retention eciency, validated against National performance Standards. An HGI incorporates a dened means of ow control, acts to entrain air to inuent, includes interior baing, or barriers in combination or separately, working to promote hydromechanical separation. HGI’s are generally installed inside the facility they serve.”
Gravity Grease Interceptor (GGI)
“A GGI is characterized by volume, minimum 30 minute retention time, bae(s), not less than two compartments, a total volume of not less than 300 gallons (1135 L), and gravity separation. If not recognized by an ocial body, a GGI will be designed by a registered professional engineer. GGI’s are generally installed outside the building they serve and buried below grade.”
Grease removal Device (GRD)
A GRD is a hydromechanical grease interceptor that mechanically removes non­petroleum fats, oils and grease (FOG) from the separation chamber, the control of which is either automatic or manually initiated and involves maintaining a liqueed state of intercepted FOG by heating. GRD’s are installed inside the facility they serve.”
Hydromechanical Grease Interceptor VS. Other Grease Interceptors
National Performance
Standards
Plumbing Code
Approvals/Listing
Specic AHJ Approval
Material
Eciency
Average Lifespan
Managed Flow
Cost Ratio Index -
Product
Annual Operation
Cost Ratio (Assumes
third party service)
Footprint Ratio
Sizing Method
Typical Installation
Time
Nature of Installation
Installer Prole
Product Availability
Endura (HGI) Endura XL (HGI) Hydromechanical Grease
7-50gpm 75-100gpm
- PDI-G101
- CSA B481
- ASME A112.14.3 (Type A)
- UPC
- IPC
- NPCC
- NSPC
Typically Not Typically Not Typically Not Yes Yes
Plastic (PP- Polypropylene) Plastic (PE/PP)- Polyethylene/
93%-99% - Based on ASME
A112.14.3 - Tested to breakdown
Min. 20 years - Typically life of system Min. 20 years - Typically life of
Yes - with Accessible Flow control Yes – Internal and External
1 0.6 (vs. GGI)
1 0.75 (vs. GGI)
1 0.3 (vs. GGI)
Flow Rate / Pipe Size Flow Rate / Pipe Size Flow Rate / Pipe Size Capacity (US Gallons) Flow Rate / Pipe Size
- On-Floor - 2-3hrs
- In Floor - 4-6hrs
- Licensed Plumber
- Common tools/practices
- Licensed Plumber - Licensed Plumber - Licensed Plumber - Licensed Plumber (Hook Up)
- Stock Item - National/Regional/ Local Plumbing Wholesale
- Restaurant Equipment Distributors
- PDI-G101 - CSA B481
- ASME A112.14.3 (Type A/C)
- UPC
- IPC
- NPCC
- NSPC
Polypropylene)
>98% - Based on ASME
A112.14.3 - NSF ES 15741
system
Accessible Flow control
0.9 (vs. HGI – Metal)
1-1.2 (vs. Plastic HGI)
0.9 (vs. HGI – Metal)
0.9 (vs. Plastic HGI)
0.9-1.2 (vs. HGI – Metal)
1.1 (vs. Plastic HGI)
- On-Floor - 2-3hrs
- In Floor – 4-8hrs
- Licensed Plumber/ Ground worker
- Earthmoving/ Excavation (below grade)
- Stock Item - National/
Regional/ Local Plumbing
Wholesale
Interceptors (HGI)
- PDI-G101
- CSA B481
- ASME A112.14.3
- UPC
- IPC
- NPCC
- NSPC
- Cast Iron
- Epoxy Coated Steel
- Plastic (PE)
Min 90% (based on Performance
Standards)
- Cast Iron (10-15 yrs)
- Epoxy Coated Steel (3-5yrs)
- Plastic (PE) (20yrs +)
Yes (Required for PDI compliance) No Yes
.9 - 1.5 8-10 6-8
1 8-10 0.5-1
1 Min 10 1
- On-Floor - 2-3hrs
- In Floor - 4-8hrs
- Licensed Plumber
- Common tools/practices
- National/Regional/ Local Plumbing Wholesale
- Restaurant Equipment Distributor
Gravity Grease Interceptors
(GGI)
None - PDI-G101
- UPC (500 USG+)
- IPC (300 USG+)
- NPCC
- NSPC
- GRP/Fiberglass
- Concrete
- Steel
No Assessment Possible Min 90% (based on
- GRP/Fiberglass (20yrs+)
- Concrete (8-10yrs)
- Steel (7-12yrs)
12-15hrs 2-4hrs
- Licensed Plumber/ Groundworker
- Earthmoving/Excavation
- Ground worker (Install)
- Local/Regional Manufacturer Direct
- Special Order -Regional/Local Plumbing Wholesale
Grease Removal
Device (GRD)
- ASME A112.14.4
Stainless Steel
Performance Standards)
- Tank (10yrs+)
- Mechanical (1-3yrs)
- Licensed Installer
- Common tools/
- Licensed Plumber
- Licensed Electrician
- Manufacturer Direct ­Local Representation
- CSA B481
- UPC
- IPC
practices
Model Chart
2000 lb 907 kg
10,000 lb
4536 kg
2000 lb 907 kg
10,000 lb
4536 kg
2000 lb 907 kg
10,000 lb
4536 kg
2000 lb 907 kg
10,000 lb
4536 kg
2000 lb 907 kg
10,000 lb
4536 kg
2000 lb 907 kg
10,000 lb
4536 kg
Product Description Connection
300 lb 135 kg
300 lb
135 kg
Endura® Compact Grease Interceptor
- 7 GPM 3907A02 - 10 GPM 3910A02 (Sux “T” for threaded inlet/outlet connections)
300 lb 135 kg
300 lb
135 kg
Endura® Grease Interceptor
- 15 GPM 3915A02 - 20 GPM 3920A02 (Sux “T” for threaded inlet/outlet connections)
300 lb 135 kg
Endura® Low Prole Grease Interceptor
- 25 GPM 3925A02LO (Sux “T” for threaded inlet/outlet connections)
Endura® Grease Interceptor
- 25 GPM 3925XTA02 - 25 GPM 3925XTA03 (Sux “T” for threaded inlet/outlet connections - 3” only)
Endura® Grease Interceptor
- 35 GPM 3935A03 - 35 GPM 3935A04 (Sux “T” for threaded inlet/outlet connections - 3” only)
300 lb
135 kg
300 lb 135 kg
300 lb
135 kg
300 lb 135 kg
300 lb
135 kg
- Compact tank / small footprint
- Injection molded in proven engineered thermoplastics for strength and durability
- EZ-Open cover latches
- Odor lock cover gasket
- Load rated cover supports up to 300 lb (135kg) of pedestrian and light duty trac
- EZ-Clean exterior tank prole with a non-ribbed section at the lower two inches of the tank
- 10 Year Limited Manufacturers Warranty
- Injection molded in proven engineered thermoplastics for strength and durability
- EZ-Open cover latches
- Odor lock cover gasket
- Load rated cover supports up to 300 lb (135kg) of pedestrian and light duty trac
- 10 Year Limited Manufacturers Warranty
- 11” in height, ideal for under sink installation
- Requires only 5” of clearance for maintenance
- Injection molded in proven engineered thermoplastics for strength and durability
- EZ-Open cover latches
- Odor lock cover gasket
- EZ-Clean tank exterior
- 10 Year Limited Manufacturers Warranty
- Injection molded in proven engineered thermoplastics for strength and durability
- EZ-Open cover latches
- Odor lock cover gasket
- Load rated cover supports up to 300 lb (135kg) of pedestrian and light duty trac
- 10 Year Limited Manufacturers Warranty
- Supplied with 2 piece ow control
- Injection molded in proven engineered thermoplastics for strength and durability
- EZ-Open cover latches
- Odor lock cover gasket
- Load rated cover supports up to 300 lb (135kg) of pedestrian and light duty trac
- 10 Year Limited Manufacturers Warranty
- Supplied with 2 piece ow control
Recycled
Size
- 7 GPM 3907A02 - 2”
- 10 GPM 3910A02 - 2”
- 15 GPM 3915A02C - 2”
Connected using mechanical joint couplings allowing for use of various piping materials.
- 20 GPM 3920A02 - 2” Minimum of 5%
Connected using mechanical joint couplings allowing for use of various piping materials.
- 25 GPM 3925A02LO - 2” Minimum of 5%
Connected using mechanical joint couplings allowing for use of various piping materials.
- 25 GPM 3925XTA02 - 2”
- 25 GPM 3925XTA03 - 3”
Connected using mechanical joint couplings allowing for use of various piping materials.
- 35 GPM 3935A03 - 3”
- 35 GPM 3935A04 - 4”
Connected using mechanical joint couplings allowing for use of various piping materials.
Content
Minimum of 5%
Minimum of 5%
Minimum of 5%
On-Floor In-Floor Extension Riser Flow Control
300 lb 135 kg
300 lb
135 kg
Endura® Grease Interceptor
- 50 GPM 3950A03 - 50 GPM 3950A04 (Sux “T” for threaded inlet/outlet connections - 3” only)
- Injection molded in proven engineered thermoplastics for strength and durability
- EZ-Open cover latches
- Odor lock cover gasket
- Load rated cover supports up to 300 lb (135kg) of pedestrian and light duty trac
- 10 Year Limited Manufacturers Warranty
- Supplied with 2 piece ow control
- 50 GPM 3950A03 - 3”
- 50 GPM 3950A04 - 4”
Connected using mechanical joint couplings allowing for use of various piping materials.
Minimum of 5%
• Check local codes for acceptance of in-oor installation
• Finish to oor level accommodating requisite materials, E.G. Tile, mortar, etc.
• Finish to oor level accommodating requisite materials, E.G. Tile, mortar, etc.
• Compatible with 3915A02 and 3920A02
On-Floor
Installation Only N/A N/A
N/A N/A
6” Modular riser
- Measurement markings
- Stackable up to 3 sets (18” Total)
- 3920AX6
Extension
Sleeve kit for 3” model only, allows access to in-oor ow control device
Custom length of SDR 35 or SDR 28 sewer pipe to be used for access sleeve
- 3” 392203W, 6” SDR 35/28 sewer pipe diameter
Standards
Conformance
*
Excluding 7 GPM
*
Listings Thermal
Capability
NYC
Commonwealth
of Massachusetts
Continuous
discharge at
104˚C (220˚F)
NYC
Commonwealth
of Massachusetts
Continuous
discharge at
104˚C (220˚F)
NYC
Commonwealth
of Massachusetts
Continuous
discharge at
104˚C (220˚F)
Remarks
3-Part Master Format Specications, CAD Drawings & BIM Drawings available at
.com
Installation Guide contact
tech-support@ endurainterceptor.com
3-Part Master Format Specications, CAD Drawings & BIM Drawings available at
.com
Installation Guide contact
tech-support@ endurainterceptor.com
3-Part Master Format Specications, CAD Drawings & BIM Drawings available at
.com
Installation Guide contact
tech-support@ endurainterceptor.com
• Finish to oor level accommodating requisite materials, E.G. Tile, mortar, etc.
• Finish to oor level accommodating requisite materials, E.G. Tile, mortar, etc.
• Finish to oor level accommodating requisite materials, E.G. Tile, mortar, etc.
6” Modular riser
- Measurement markings
- Stackable up to 3 sets (18” Total)
- 3925AX6
6” Modular riser
- Measurement markings
- Stackable up to 3 sets (18” Total)
- 3935AX6
6” Modular riser
- Measurement markings
- Stackable up to 3 sets (18” Total)
- 3935AX6
Sleeve kit allows access to in-oor ow control device
Custom length of SDR 35 or SDR 28 sewer pipe to be used for access sleeve
- 3” 392203W, 6” SDR 35/28 sewer pipe diameter
Sleeve kit allows access to in-oor ow control device
Custom length of SDR 35 or SDR 28 sewer pipe to be used for access sleeve
- 3” 392203W, 6” SDR 35/28 sewer pipe diameter
- 4” 392204W, 8” SDR 35/28 sewer pipe diameter
Sleeve kit allows access to in-oor ow control device
Custom length of SDR 35 or SDR 28 sewer pipe to be used for access sleeve
- 3” 392203W, 6” SDR 35/28 sewer pipe diameter
- 4” 392204W, 8” SDR 35/28 sewer pipe diameter
NYC
Commonwealth
of Massachusetts
NYC
Commonwealth
of Massachusetts
NYC
Commonwealth
of Massachusetts
Continuous
discharge at
104˚C (220˚F)
Continuous
discharge at
104˚C (220˚F)
Continuous
discharge at
104˚C (220˚F)
3-Part Master Format Specications, CAD Drawings & BIM Drawings available at
.com
Installation Guide contact
tech-support@ endurainterceptor.com
3-Part Master Format Specications, CAD Drawings & BIM Drawings available at
.com
Installation Guide contact
tech-support@ endurainterceptor.com
3-Part Master Format Specications, CAD Drawings & BIM Drawings available at
.com
Installation Guide contact
tech-support@ endurainterceptor.com
Dimensions
Endura® 7GPM - 10GPM Models
3907A02 7GPM (0.44 LPS)
2” (51mm) connection
3910A02 10GPM (0.63 LPS)
2” (51mm) connection
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2” INLET/OUTLET MODELS
2” FCD
Endura® 15GPM - 20GPM Models
3915A02 15GPM (0.94 LPS)
2” (51mm) connection
3920A02 20GPM (1.26 LPS)
2” (51mm) connection
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2” INLET/OUTLET MODELS
2” FCD
Endura® Lo-PRO Grease Interceptor 25GPM Model
3925A02LO 25GPM (1.6 LPS)
2” (51mm) connection
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) -2” INLET/OUTLET MODEL
2” FCD
Endura® 25GPM Models
3925XTA02 25GPM (1.6 LPS)
2” (51mm) connection
3925XTA03 25GPM (1.6 LPS)
3” (76mm) connection
2” FCD
3” FCD
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) - 2” , 3” INLET/ OUTLET MODELS
Endura® 35GPM Models
3935A03 35GPM (2.2 LPS)
3” (76mm) connection
3935A04 35GPM (2.2 LPS)
4” (110mm) connection
3” FCD
4” FCD
A
B
3925XTA02
A 4 ” 4.5”
B 12.5” 12”
(2”)
3925XTA03
(3”)
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) - 3” or 4” INLET/OUTLET MODELS
Endura® 50GPM Models
3950A03 50GPM (3.2 LPS)
3” (76mm) connection
3950A04 50GPM (3.2 LPS)
4” (110mm) connection
3” FCD
4” FCD
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI) - 3” or 4” INLET/OUTLET MODELS
Model Chart
Grade
.625" Raised Cover
Grade
.625" Raised Cover
10,000 lb
4536 kg
10,000 lb
4536 kg
Product Description Connection
2000 lb
907 kg
M
Load Rating
Endura® XL Grease Interceptor
- XL75 – 75GPM 4075A04(T)
- XL75 – 75GPM 4075A04M(T)
2000 lb
907 kg
M
Load Rating
Endura® XL Grease Interceptor
- XL100 – 100GPM 40100A04(T)
- XL100 – 100GPM 40100A04M(T)
S
S
10,000 lb
4536 kg
Load Rating
10,000 lb
4536 kg
Load Rating
- 559lb Grease Capacity >98% Eciency
- Dynamic Inlet Bae – Internal ow Control (Supplied Standard)
· Optional External ow control (PDI G101)
· Seamless Tank – Rotationally moulded using up to 100% recompounded material
· Dual Access Covers
- Mechanically secured
- Trac rated CSA B481.0 Type ‘S’
- Pedestrian/Light Trac CSA B481.0 Type ‘M’
· Airtight/Watertight cover, frame and adjustable riser system
· Limited Lifetime Warranty
- 1058lb Grease Capacity >98% Eciency
- Dynamic Inlet Bae – Internal ow Control (Supplied Standard)
· Optional External ow control (PDI G101)
· Seamless Tank – Rotationally moulded using up to 100% recompounded material
· Dual Access Covers
- Mechanically secured
- Trac rated CSA B481.0 Type ‘S’
- Pedestrian/Light Trac CSA B481.0 Type ‘M’
· Airtight/Watertight cover, frame and adjustable riser system
· Limited Lifetime Warranty
Size
Inlet - 4” Sch40 DWV Outlet – 4” Sch40 DWV FTP 4” Optional for Inlet & Outlets (Sux ‘T’) Outlet (Side) – 4” SDR35 Sewer
Connected using mechanical joint couplings allowing for use of various piping materials.
Consult local code for connection format compliance.
Inlet - 4” Sch40 DWV Outlet – 4” Sch40 DWV FTP 4” Optional for Inlet & Outlets (Sux ‘T’) Outlet (Side) – 4” SDR35 Sewer
Connected using mechanical joint couplings allowing for use of various piping materials.
Consult local code for connection format compliance.
Access Covers
Trac Rated
CSA B481.0 Type ‘S’
Grade
.625" Raised Cover
Pedestrian/Light Trac Rated
CSA B481.0 Type ‘M’
Cover Flush to Grade
Trac Rated
CSA B481.0 Type ‘S’
Grade
.625" Raised Cover
Pedestrian/Light Trac Rated
CSA B481.0 Type ‘M’
Cover Flush to Grade
On-Floor
TRAFFIC RATED
PEDESTRIAN / LIGHT TRAFFIC
Dimensions - XL models
Endura® XL 75GPM Models
4075A04
75GPM (4.74 LPS) 4” (110 mm) no hub connection
4075A04T
75GPM (4.74 LPS) 4” (110 mm) female threaded connection (FPT)
4075A04M
75GPM (4.74 LPS) 4” (110 mm) no hub connection
4075A04MT
75GPM (4.74 LPS) 4” (110 mm) female threaded connection (FPT)
Notes: ACCESSIBLE FLOW CONTROL DEVICE (FCD) IS SUPPLIED FOR INSTALLATION UPSTREAM OF THE GREASE INTERCEPTOR (GI)
-4” INLET/OUTLET MODELS
4” External FCD
Pipe by
others
Loading...
+ 16 hidden pages