A
www.uniquip.ca
Uniquip Canada Inc. guarantees all Uniquip Endura Tower Lights to be free
from any manufacturer's defects in material and workmanship for a period of one (1) year from the date of purchase . This warranty is exclusive of any normal wear and tear and/or consumable parts, such as the lamp, fuse, and wheels. All normal wear and tear and/or consumable parts are protected from manufacturer's defects in material and workmanship for a period of thirty (30) days from the date of purchase.
To make a warranty claim within this time period, please contact the Service Manager at Uniquip Canada Inc., 1-800-332-4012, who will advise the validity and claim procedure. Once the claim has been accepted by Uniquip Canada, the unit and parts should be shipped to Uniquip Canada or the specified Authorized Service Centre at the customer's expense. Be sure to securely pack the unit and parts in a strong container. Damage in transit is not covered by this warranty. All approved repairs under this warranty will be returned by Uniquip Canada free of charge.
Warranties expressed in this document are void if repairs are attempted by anyone other than an Authorized Service Centre or Uniquip Canada or if the unit has been modified from original factory design in any way. This warranty is expressly conditional upon the customer's compliance with all precautions and instructions contained in this manual and excludes any claims made as a result of abuse, neglect, accident, normal wear and tear and misuse. This warranty is non-
transferable.
Uniquip Canada Inc.'s liability under warranty is limited to repair of the product and/or replacement of parts and is given to the purchaser in lieu of all other remedies including incidental and consequential charges. There are no expressed warranties other than those specified herein.
Endura Warranty Statement
Endura Warranty Summary Protection
1. Uniquip Endura Tower Light Unit 1 year parts and labour
2. Uniquip Endura normal wear and tear parts or consumable parts
30 days parts and labour
B
www.uniquip.ca
Congratulations for choosing an Endura product to meet all your tough jobsite needs! Please file your original bill of purchase for this unit in a safe place. For warranty service of your Endura product, you will need to provide a copy of this document to confirm your warranty status.
Product registration is a key step toward enjoying your new Endura product! While registration is not necessary to enjoy our manufacturer's warranty, there are many benefits to participating in this program. Registration helps to facilitate warranty service, and notify you of any updates, changes, and service advisories on your product. Complete this Warranty Registration Card and fax it to 1-866-825-2221 or mail it to the address on the back of this card:
Endura Warranty Registration
Warranty Registration Information
A. Ownership Information
Owner’s Name: Company Name: Company Address:
Company Telephone: Company Fax: Company E-Mail: Company Website:
B. Machine Information
Machine Make: Machine Model #: Machine Serial #: Date of Purchase:
C. Product Information Update
Can we contact you with any product-related news?
___Yes ___No
Who should we contact? Contact Telephone: Contact Fax: Contact E-Mail: What is the preferred contact method?
Uniquip Canada Inc.
2437 Michelin
Laval QC
H7L 5B9
ATTN: SERVICE DEPARTMENT
Place
Stamp
Here
FSTL1000
Endura Tower Light Operator's Manual
READ ALL the sections in this manual PRIOR to attempting to service, maintain or operate this equipment.
Copyright Uniquip Canada 2004. All rights reserved.
DO NOT operate this equipment until you have read and understood all the enclosed Operator's Manual.
Pre-Operation Note ........................................................................................ 1
Safety Precautions .......................................................................................... 2
Guide to Machine Overview .......................................................................... 3
Machine Overview ........................................................................................ 4
Parts List ....................................................................................................... 5
Key Components Overview ...........................................................6, 7, 8, 9, 10
Contents List ................................................................................................ 11
Setting up the FSTL1000 ..........................................................................12, 13
Pre-Operation Procedures ............................................................................ 14
Operation Procedures ................................................................................. 15
®
1
www.uniquip.ca
Thank you for your purchase of the Uniquip Endura FSTL1000 Portable Tower Light. This tower light has been designed and manufactured to our highest quality demands for durability and performance.
Uniquip Canada Inc. is committed to offering durable products and quality after-market service. The FSTL1000 Portable Tower Light is warranted to be free from manufacturer's defects in material and workmanship for a period of one (1) year from the date of shipping as declared on the invoice from Uniquip Canada. This warranty will be void if the light tower has not been operated and maintained in the manner prescribed in this Operator's Manual.
In order for the tower light to perform at its optimum capabilities, the operator of the unit must read this manual thoroughly before using this unit. This Operator's Manual contains important product operation procedures, and safety precautions. SAVE THIS MANUAL. Please keep this manual nearby when operating the tower light as a reference should any questions arise.
This tower light is a high voltage electrical device. DO NOT start
this unit unless it is clear of water or water-filled areas. DO NOT use this tower light with non-grounded sockets. Use this light only with GFCI protected circuits. This product is designed for normal outdoor use.
All jobsites are different. Please ensure that when installing this tower light in a jobsite, proper precautions have been taken to avoid any accidents, and to reduce the risk of fire, electric shock or personal injury.
Every care and effort has been made to ascertain the accuracy and completeness of procedures described in this document to ensure your enjoyment and satisfaction. If you have any questions or concerns, please contact the Service Department at Uniquip Canada at 1-800-332-4012.
Pre-Operation Notes
Technical Support Hotline
Ontario,
Western Canada, and USA
T : 1-888-332-4012 F : 1-866-567-0956
Quebec
and Eastern Canada
T : 1-800-332-4012 F : 1-866-825-2221
email your technical questions and comments to:
service@uniquip.ca
visit our website:
www.uniquip.ca
2
www.uniquip.ca
1. READ AND UNDERSTAND OPERATOR'S MANUAL PRIOR TO USE OF TOWER LIGHT.
2. THE LIGHTED LAMP IS HOT. DO NOT TOUCH LIGHT FIXTURE, REFLECTOR OR LENS DURING USE. WAIT FOR AT LEAST 10 MINUTES AFTER SHUT-DOWN TO BE IN CONTACT WITH LAMP.
3. Make certain that the power source conforms to the requirements of your
equipment. NEVER ALTER THE PLUG.
4. DO NOT plug pump into any NON-GROUNDED electrical outlet.
5. DO NOT attempt to remove ground stem on plug.
6. USE ONLY on GFCI protected circuits.
7. MAKE SURE OPERATOR, CABLE, PLUG AND SOCKET ARE ALL
DRY AND CLEAN. LIQUIDS AND ELECTRICITY DO NOT MIX. CHEMICALS AND ELECTRICITY DO NOT MIX.
8. DO NOT operate where water may accumulate around base.
9. DO NOT submerse any portion of the FSTL-1000MH Tower Light in liquid.
10. Keep light AT LEAST 16' FT AWAY from pools and spas.
11. Keep light away from any flammable materials.
12. DO NOT perform any repairs or maintenance procedures on tower light
unless it has been disconnected from any power source.
13. Use only Endura brand-name parts.
14. ALL frayed and/or otherwise damaged cords and components MUST
be replaced before further use.
15. When using in windy and or other difficult weather conditions, set tower
light up such that the wind is at the back of the fixture and apply the brake. Support with sand bags if necessary.
16. If light is extended higher than 6' ft, anchor base to ground.
17. Always ensure that tires are filled up at proper tire pressure.
18. Always set brake on tower light for transport or when tower light will
be left unattended.
19. Never use any light bulbs larger than what the fixture is rated for.
20. NEVER LOOK DIRECTLY INTO LIGHTED LAMP.
21. NEVER OPERATE THE FIXTURE WITHOUT SAFETY LENS. If safety
lens is broken, replace lens prior to operating fixture.
22. Keep fixture away from children.
23. DANGER: HIGH VOLTAGE!
24. Provide adequate protection and guarding of all movable parts.
SAVE THESE INSTRUCTIONS.
Safety Precautions
3
www.uniquip.ca
Regular maintenance and parts replacement are important steps to extending
the life of your equipment and enjoying its optimum performance. When performing any maintenance or repair procedures, always check with local authorities
for by-laws and guidelines governing your jurisdiction.
This guide aims to serve as a representational guide to the FSTL1000. Any other uses or application beyond the scope of this document are strictly prohibited. While every attempt has been made to maintain its accuracy, Uniquip
Canada Inc. reserves the right to update and modify the equipment without prior notification. Prior to undertaking to perform any maintenance or repair procedures, please contact our Technical Support Hotline for clarification and to acquire appropriate parts.
To order spare parts, please provide the following information:
1. Machine Make
2. Model Number
3. Machine Serial Number
4. Quantity Required of Each Part
5. Part Numbers
6. Part Descriptions.
All Endura parts are guaranteed by a thirty (30) day warranty against any manufacturer's defects in workmanship and material. Consult page A in the Operator's Manual for further details on our Warranty Policy.
Technical Support Hotline
Ontario,
Western Canada, and USA
T : 1-888-332-4012 F : 1-866-567-0956
Quebec
and Eastern Canada
T : 1-800-332-4012 F : 1-866-825-2221
email your technical questions and comments to:
service@uniquip.ca
visit our website:
www.uniquip.ca
Guide to Machine Overview/Parts List
4
www.uniquip.ca
1
8
14
7
5
4
3
2
13
12
11
10
9
6
Machine Overview
5
www.uniquip.ca
Parts List
Many of the parts making up each section of the FSTL1000 Tower Light have been packaged into kits for your convenience! Refer to the "Key Components Overview" section for further details.
If you have any questions concerning the maintenance and operations of this unit, please do not hesitate to contact Uniquip Canada.
DO NOT attempt servicing or performing any maintenance procedures outlined in this manual unless technician is qualified and clear on the task's requirements.
Legend Part Number Description
1 FSTL1000-01 Fixture 2 FSTL1000-02 Reflector 3 FSTL1000-03 Lens Clips 4 FSTL1000-LENS Lens Kit 5 FSBD-BULB1000 1000 W Metal Halide Lamp 6 FSTL1000-06 U-Bracket 7 FSTL1000-07 Mast 8 FSTL1000-08 Cart
9 FSTL1000-BRAKE Brake Kit 10 FSTL1000-10 Wheels 11 FSTL1000-11 Ballast (Not shown. See
“Key Components Overview”
for details.) 12 FSTL1000-12 Ballast Box 13 FSTL1000-13 Ballast Lid 14 FSTL1000-14 Cord
6
www.uniquip.ca
Key Components Overview
A. Reflector and Lens Assembly
15
21
22
3
18
2
17
16
1
19
20
27
23
24
25
26
B. Ballast Assembly
30
11
29
28
12