FSTL1000
Endura Tower Light
Operator's Manual
READ ALL the sections in this manual PRIOR to
attempting to ser vice, maintain or operate this
equipment.
Copyright Uniquip Canada 2004. All rights reserved.
DO NOT operate this equipment until you have
read and understood all the enclosed Operator's
Manual.
®

A
www.uniquip.ca
Uniquip Canada Inc. guarantees all Uniquip Endura Tower Lights to be free
from any manufacturer's defects in material and workmanship for a period of one (1)
year from the date of purchase . This warranty is exclusive of any normal wear and
tear and/or consumable parts, such as the lamp, fuse, and wheels. All normal wear
and tear and/or consumable parts are protected from manufacturer's defects in
material and workmanship for a period of thirty (30) days from the date of
purchase.
To make a warranty claim within this time period, please contact the Service
Manager at Uniquip Canada Inc., 1-800-332-4012, who will advise the validity and
claim procedure. Once the claim has been accepted by Uniquip Canada, the unit
and parts should be shipped to Uniquip Canada or the specified Authorized Service
Centre at the customer's expense. Be sure to securely pack the unit and parts in a
strong container. Damage in transit is not covered by this warranty.
All approved repairs under this warranty will be returned by Uniquip Canada free of
charge.
Warranties expressed in this document are void if repairs are attempted by
anyone other than an Authorized Service Centre or Uniquip Canada or if the unit has
been modified from original factory design in any way. This warranty is expressly
conditional upon the customer's compliance with all precautions and instructions
contained in this manual and excludes any claims made as a result of abuse, neglect,
accident, normal wear and tear and misuse. This warranty is non-
transferable.
Uniquip Canada Inc.'s liability under warranty is limited to repair of the
product and/or replacement of parts and is given to the purchaser in lieu of all other
remedies including incidental and consequential charges. There are no expressed
warranties other than those specified herein.
Endura Warranty Statement
Endura Warranty Summary Protection
1. Uniquip Endura Tower Light Unit 1 year parts and labour
2. Uniquip Endura normal wear and
tear parts or consumable parts
30 days parts and labour
B
www.uniquip.ca
Congratulations for choosing an Endura product to meet all your tough
jobsite needs! Please file your original bill of purchase for this unit in a safe place.
For warranty service of your Endura product, you will need to provide a copy of this
document to confirm your warranty status.
Product registration is a key step toward enjoying your new Endura
product! While registration is not necessary to enjoy our manufacturer's warranty,
there are many benefits to participating in this program. Registration helps to
facilitate warranty service, and notify you of any updates, changes, and service
advisories on your product. Complete this Warranty Registration Card and fax it to
1-866-825-2221 or mail it to the address on the back of this card:
Endura Warranty Registration
Warranty Registration Information
A. Ownership Information
Owner’s Name:
Company Name:
Company Address:
Company Telephone:
Company Fax:
Company E-Mail:
Company Website:
B. Machine Information
Machine Make:
Machine Model #:
Machine Serial #:
Date of Purchase:
C. Product Information Update
Can we contact you with any
product-related news?
___Yes ___No
Who should we contact?
Contact Telephone:
Contact Fax:
Contact E-Mail:
What is the preferred contact method?

Uniquip Canada Inc.
2437 Michelin
Laval QC
H7L 5B9
ATTN: SERVICE DEPARTMENT
Place
Stamp
Here
FSTL1000
Endura Tower Light
Operator's Manual
READ ALL the sections in this manual PRIOR to
attempting to service, maintain or operate this
equipment.
Copyright Uniquip Canada 2004. All rights reserved.
DO NOT operate this equipment until you have
read and understood all the enclosed Operator's
Manual.
Pre-Operation Note ........................................................................................ 1
Safety Precautions .......................................................................................... 2
Guide to Machine Overview .......................................................................... 3
Machine Overview ........................................................................................ 4
Parts List ....................................................................................................... 5
Key Components Overview ...........................................................6, 7, 8, 9, 10
Contents List ................................................................................................ 11
Setting up the FSTL1000 ..........................................................................12, 13
Pre-Operation Procedures ............................................................................ 14
Operation Procedures ................................................................................. 15
®

1
www.uniquip.ca
Thank you for your purchase of the Uniquip Endura FSTL1000 Portable
Tower Light. This tower light has been designed and manufactured to our
highest quality demands for durability and performance.
Uniquip Canada Inc. is committed to offering durable products and
quality after-market service. The FSTL1000 Portable Tower Light is warranted
to be free from manufacturer's defects in material and workmanship for a
period of one (1) year from the date of shipping as declared on the invoice
from Uniquip Canada. This warranty will be void if the light tower has not
been operated and maintained in the manner prescribed in this Operator's
Manual.
In order for the tower light to perform at its optimum capabilities, the
operator of the unit must read this manual thoroughly before using this
unit. This Operator's Manual contains important product operation
procedures, and safety precautions. SAVE THIS MANUAL. Please keep
this manual nearby when operating the tower light as a reference should any
questions arise.
This tower light is a high voltage electrical device. DO NOT start
this unit unless it is clear of water or water-filled areas. DO NOT
use this tower light with non-grounded sockets. Use this light
only with GFCI protected circuits. This product is designed for
normal outdoor use.
All jobsites are different. Please ensure that when installing this tower
light in a jobsite, proper precautions have been taken to avoid any accidents,
and to reduce the risk of fire, electric shock or personal injury.
Every care and effort has been made to ascertain the accuracy and
completeness of procedures described in this document to ensure your
enjoyment and satisfaction. If you have any questions or concerns, please
contact the Service Department at Uniquip Canada at 1-800-332-4012.
Pre-Operation Notes
Technical Support Hotline
Ontario,
Western Canada, and USA
T : 1-888-332-4012
F : 1-866-567-0956
Quebec
and Eastern Canada
T : 1-800-332-4012
F : 1-866-825-2221
email your technical questions and comments to:
service@uniquip.ca
visit our website:
www.uniquip.ca
2
www.uniquip.ca
1. READ AND UNDERSTAND OPERATOR'S MANUAL PRIOR TO USE
OF TOWER LIGHT.
2. THE LIGHTED LAMP IS HOT. DO NOT TOUCH LIGHT FIXTURE,
REFLECTOR OR LENS DURING USE. WAIT FOR AT LEAST 10
MINUTES AFTER SHUT-DOWN TO BE IN CONTACT WITH LAMP.
3. Make certain that the power source conforms to the requirements of your
equipment. NEVER ALTER THE PLUG.
4. DO NOT plug pump into any NON-GROUNDED electrical outlet.
5. DO NOT attempt to remove ground stem on plug.
6. USE ONLY on GFCI protected circuits.
7. MAKE SURE OPERATOR, CABLE, PLUG AND SOCKET ARE ALL
DRY AND CLEAN. LIQUIDS AND ELECTRICITY DO NOT MIX.
CHEMICALS AND ELECTRICITY DO NOT MIX.
8. DO NOT operate where water may accumulate around base.
9. DO NOT submerse any portion of the FSTL-1000MH Tower Light in liquid.
10. Keep light AT LEAST 16' FT AWAY from pools and spas.
11. Keep light away from any flammable materials.
12. DO NOT perform any repairs or maintenance procedures on tower light
unless it has been disconnected from any power source.
13. Use only Endura brand-name parts.
14. ALL frayed and/or otherwise damaged cords and components MUST
be replaced before further use.
15. When using in windy and or other difficult weather conditions, set tower
light up such that the wind is at the back of the fixture and apply the
brake. Support with sand bags if necessary.
16. If light is extended higher than 6' ft, anchor base to ground.
17. Always ensure that tires are filled up at proper tire pressure.
18. Always set brake on tower light for transport or when tower light will
be left unattended.
19. Never use any light bulbs larger than what the fixture is rated for.
20. NEVER LOOK DIRECTLY INTO LIGHTED LAMP.
21. NEVER OPERATE THE FIXTURE WITHOUT SAFETY LENS. If safety
lens is broken, replace lens prior to operating fixture.
22. Keep fixture away from children.
23. DANGER: HIGH VOLTAGE!
24. Provide adequate protection and guarding of all movable parts.
SAVE THESE INSTRUCTIONS.
Safety Precautions

3
www.uniquip.ca
Regular maintenance and parts replacement are important steps to extending
the life of your equipment and enjoying its optimum performance. When performing
any maintenance or repair procedures, always check with local authorities
for by-laws and guidelines governing your jurisdiction.
This guide aims to serve as a representational guide to the FSTL1000. Any
other uses or application beyond the scope of this document are strictly
prohibited. While every attempt has been made to maintain its accuracy, Uniquip
Canada Inc. reserves the right to update and modify the equipment without prior
notification. Prior to undertaking to perform any maintenance or repair procedures,
please contact our Technical Support Hotline for clarification and to acquire
appropriate parts.
To order spare parts, please provide the following information:
1. Machine Make
2. Model Number
3. Machine Serial Number
4. Quantity Required of Each Part
5. Part Numbers
6. Part Descriptions.
All Endura parts are guaranteed by a thirty (30) day warranty against any
manufacturer's defects in workmanship and material. Consult page A in the
Operator's Manual for further details on our Warranty Policy.
Technical Support Hotline
Ontario,
Western Canada, and USA
T : 1-888-332-4012
F : 1-866-567-0956
Quebec
and Eastern Canada
T : 1-800-332-4012
F : 1-866-825-2221
email your technical questions and comments to:
service@uniquip.ca
visit our website:
www.uniquip.ca
Guide to Machine Overview/Parts List
4
www.uniquip.ca
1
8
14
7
5
4
3
2
13
12
11
10
9
6
Machine Overview

5
www.uniquip.ca
Parts List
Many of the parts making up each section of the FSTL1000 Tower Light have
been packaged into kits for your convenience! Refer to the "Key Components
Overview" section for further details.
If you have any questions concerning the maintenance and operations of this
unit, please do not hesitate to contact Uniquip Canada.
DO NOT attempt servicing or performing any maintenance
procedures outlined in this manual unless technician is qualified
and clear on the task's requirements.
Legend Part Number Description
1 FSTL1000-01 Fixture
2 FSTL1000-02 Reflector
3 FSTL1000-03 Lens Clips
4 FSTL1000-LENS Lens Kit
5 FSBD-BULB1000 1000 W Metal Halide Lamp
6 FSTL1000-06 U-Bracket
7 FSTL1000-07 Mast
8 FSTL1000-08 Cart
9 FSTL1000-BRAKE Brake Kit
10 FSTL1000-10 Wheels
11 FSTL1000-11 Ballast (Not shown. See
“Key Components Overview”
for details.)
12 FSTL1000-12 Ballast Box
13 FSTL1000-13 Ballast Lid
14 FSTL1000-14 Cord
6
www.uniquip.ca
Key Components Overview
A. Reflector and Lens Assembly
15
21
22
3
18
2
17
16
1
19
20
27
23
24
25
26
B. Ballast Assembly
30
11
29
28
12
13
31