Endless summer GAD860SP User Manual

BlueRhino.com
Available in U.S. only.
WARNING
FOR YOUR SAFETY:
For Outdoor Use Only (outside any enclosure) Do NOT Use For Cooking.
®
OWNER’S MANUAL
LP Gas Outdoor Fireplace
Model No. GAD860SP
WARNING
FOR YOUR SAFETY:
W If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
W WHAT TO DO IF YOU SMELL GAS:
• Do NOT try lighting any appliance.
• Do NOT touch any electrical switch; do NOT use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
• Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
W Installation and service must be performed
by a qualified installer, service agency or gas supplier.
W Save these instructions for future
reference.
W If you are assembling this unit for someone
else, give this manual to them to read and save for future reference.
· DANGER
Table of Contents
CARBON MONOXIDE HAZARD
• This appliance can produce carbon monoxide which has no odor.
• Using it in an enclosed space can kill you.
• Never use this appliance in an enclosed space such as a camper, tent, car or home.
WARNING
FOR YOUR SAFETY:
Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage.
Read the installation, operation and
maintenance instructions thoroughly before installing or servicing this equipment.
DANGER
If you smell gas:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appliance and immediately call your gas supplier or your fire department.
WARNING
FOR YOUR SAFETY:
Important Safeguards ...........................................................Page 2
Expanded View and Hardware......................................................... 4
Assembly Instructions............................................................... 5
Installing LP Gas Tank............................................................... 8
Operating Instructions............................................................... 9
Cleaning and Care ................................................................. 9
Product Registration ............................................................... 10
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Limited Warranty ................................................................ 10
Troubleshooting .................................................................. 11
The use and installation of this product must conform to local codes. In absence of local codes, use the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or International Fuel Gas Code. This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the National Electrical Code, ANSI/NFPA 70, if applicable.
THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ AND KEEP FOR FUTURE REFERENCE.
If you are assembling this unit for someone else, give this manual to them to read and save for future reference.
California Proposition 65: Combustion by-products produced when using this product contain chemicals known to the State of California to cause cancer, birth defects, and other reproductive harm.
California Proposition 65: Wash your hands after handling this product.
California Proposition 65: Handling the brass material on this product exposes you to lead, a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.
1. Do NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
2. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
DANGER
Do NOT leave this appliance unattended while it is in operation.
Manufactured in China for: Blue Rhino Global Sourcing, Inc. Winston-Salem, NC 27105 USA • 1.800.762.1142 • BlueRhino.com © Blue Rhino Global Sourcing, Inc. Endless Summer
®
is a Registered Trademark of Blue Rhino Global Sourcing, Inc. GAD860SP-E-OM-F107
Made from 75% Bagasse
(environmentally friendly sugar
cane pulp by-product)
2
®
LP Gas Outdoor Fireplace
Model No. GAD860SP
Important Safeguards
W DANGER: Failure to follow the dangers, warnings and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion
causing damage to property.
W WARNINGS:
W This appliance is for outdoor use only, and should NOT be used in a
building, garage or any other enclosed area.
W Do NOT operate, light or use this appliance within ten feet (3.05 m) of
walls, structures or buildings.
W For residential use only. This outdoor fireplace is NOT for commercial
use.
W Do NOT use this outdoor fireplace for indoor heating. TOXIC carbon
monoxide fumes can accumulate and cause asphyxiation.
W This outdoor fireplace is safety certified for use in the United States
and/or Canada only. Do NOT modify for use in any other location. Modification will result in a safety hazard and will void your warranty.
W Apartment dwellers: Check with management to learn the requirements
and fire codes for using a liquid propane (LP) gas outdoor fireplace in your apartment complex. If allowed, use outside on the ground floor with a ten foot (3.05 m) clearance from any structure. Do NOT use on or under balconies.
W This outdoor fireplace, from the factory, is for use with LP gas only. The
conversion to or attempted use of natural gas in this outdoor fireplace is dangerous, may cause bodily harm and will void your warranty.
W LP gas characteristics:
a. LP gas is flammable and hazardous if handled improperly. Become
aware of the characteristics before using any LP gas product.
b. LP gas is explosive under pressure, heavier than air, and settles/
pools in low areas.
c. LP gas in its natural state has no odor. For your safety, an odorant is
added that smells like rotten cabbage.
d. Contact with LP gas can cause freeze burns to skin.
W Your outdoor fireplace has been checked at all factory connections
for leaks. Recheck all connections as described in the “Operating Instructions” section, as shipping can loosen connections.
W Check for leaks even if your unit was assembled for you by someone
else.
W Do NOT operate if a gas leak is present. Gas leaks may cause a fire or
explosion.
W You must follow all instructions in the “Checking for Leaks” section
before operating. To prevent a fire or explosion when testing for a leak:
a. Always perform a leak test before lighting this outdoor fireplace and
each time the tank is connected for use.
b. No smoking. Do NOT use or permit sources of ignition in the area
while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do NOT use matches, lighters or a flame to check for leaks.
e. The use of alcohol, prescription or non-prescription drugs may
impair the consumer’s ability to properly assemble or safely operate the appliance.
f. Strong odors, colds, sinus congestion, etc. may prevent the
detection of propane. Use caution and common sense when testing for leaks.
g. Do NOT use this outdoor fireplace until any and all leaks are
corrected. If you are unable to stop a leak, disconnect the LP gas supply. Call a gas appliance serviceman or your local LP gas supplier.
W Do NOT store or use gasoline or other flammable liquids or vapors
within 25 feet (7.62 m) of this appliance.
W LP gas tank needed to operate. Only tanks marked “propane” may be
used.
a. The LP gas cylinder must be constructed and marked in accordance
with the U.S. Department of Transportation (D.O.T.) Specifications for
LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods and Commission, CAN/ CSA-B339 as applicable.
b. LP gas tank must be arranged for vapor withdrawal.
c. The LP gas tank must have a listed overfilling prevention device
(OPD) and a QCCI or Type I (CGA810) LP gas tank connection.
d. The LP gas tank must have a tank collar to protect the tank valve.
e. Never use an LP gas tank with a damaged body, valve, collar or
footing.
f. Dented or rusted LP gas tanks may be hazardous and should be
checked by your LP gas supplier prior to use.
g. The LP gas tank should not be dropped or handled roughly.
h. Tanks must be stored outdoors, out of the reach of children and
must not be stored in a building, garage or any other enclosed area. Your LP gas tank must never be stored where temperatures can reach over 125°F.
i. Do NOT insert any tool or foreign object into the valve outlet or
safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury or death.
j. Never keep an LP gas tank in a hot car or trunk. Heat will cause the
gas pressure to increase, which may open the relief valve and allow gas to escape.
k. Place dust cap on cylinder valve outlet whenever the cylinder is not
in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
l. Do NOT store a spare LP gas tank under or near this appliance.
m. Never fill the cylinder beyond 80 percent full.
n. A fire causing serious injury or damage to property may occur if the
above is not followed exactly.
W Do NOT use in an explosive atmosphere. Keep outdoor fireplace
area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
W This outdoor fireplace is NOT to be operated by children.
W This outdoor fireplace is NOT to be used in or on boats or recreational
vehicles.
W Do NOT connect to a remote gas supply.
W Never attempt to attach this outdoor fireplace to the self-contained LP
gas system of a camper trailer, motor home or house.
W Always use in accordance with all applicable local, state and national
codes. Contact your local fire department for details on outdoor burning.
W When using this outdoor fireplace, exercise the same precautions you
would with any open fire.
W Do NOT use this outdoor fireplace without reading the entire Owner’s
Manual.
W Do NOT burn solid fuels such as: wood, charcoal briquettes, lump
charcoal, manufactured logs, driftwood, trash, leaves, paper, cardboard, plywood, painted/stained/pressure treated wood in this outdoor fireplace.
W It is essential to keep the outdoor fireplace’s valve compartment,
burners, and circulating air passages clean. Inspect outdoor fireplace before each use.
W Do NOT use this outdoor fireplace until it is COMPLETELY assembled and
all parts are securely fastened and tightened.
W Do NOT use this outdoor fireplace near automobiles, trucks, vans or
recreational vehicles.
W Do NOT use this outdoor fireplace under any overhang or near any
unprotected combustible constructions. Avoid using near or under overhanging trees and shrubs.
W Always use this outdoor fireplace on a hard, level, non-combustible
surface such as concrete, rock or stone. An asphalt or blacktop surface may not be acceptable for this purpose.
W Do NOT use this outdoor fireplace for cooking.
Need help? 1.800.762.1142
Do not return to place of purchase.
Replacement Parts
3
1.800.762.1142
W Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part or control system and any gas control which has been under water.
W Do NOT wear flammable or loose clothing when operating this outdoor
fireplace.
W Do NOT use in windy conditions.
W Never lean over this outdoor fireplace when lighting or when in use.
W Do NOT use this outdoor fireplace unless burner is securely in place.
W Keep all electrical cords away from this outdoor fireplace during use.
W Certain areas of this outdoor fireplace when in use will become too
hot to touch. To avoid burns, do NOT touch hot surfaces until the unit has completely cooled (about 45 minutes), unless you are wearing protective gear (such as insulated pot holders or heat-resistant gloves/ mittens).
W Do NOT leave a lit outdoor fireplace unattended, especially around
children and pets.
W Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burns or clothing ignition.
W Young children should be carefully supervised when they are in the area
of the appliance.
W Do NOT hang or place clothing or other flammable material on or near
this appliance.
W Any guard or other protective device removed for servicing the
appliance must be replaced prior to operating the appliance.
W If applicable, protective cover must be removed when burner is in
operation.
W Do NOT attempt to move outdoor fireplace when in use. Allow the
outdoor fireplace to cool before moving or storing.
W This outdoor fireplace should be thoroughly cleaned and inspected on a
regular basis.
a. Clean and inspect the hose before each use of the appliance. If
there is evidence of abrasion, wear, cuts, or leaks, the hose must be replaced prior to the appliance being operated. Use only the hose specified by Blue Rhino Global Sourcing, Inc.
b. Inspect the burner before each use of the appliance. If there is
evidence of burner damage, the burner must be replaced prior to the appliance being operated. Use only the burner specified by Blue Rhino Global Sourcing, Inc.
W Use only the regulator and hose assembly provided. Use only the
replacement regulator and hose assembly specified by Blue Rhino Global Sourcing, Inc.
W Use only the burner provided. Use only the replacement burner specified
by Blue Rhino Global Sourcing, Inc.
W Use only Blue Rhino Global Sourcing, Inc. factory-authorized parts. The
use of any part that is not factory-authorized can be dangerous and will void your warranty.
W Use only Blue Rhino Global Sourcing, Inc. factory-authorized glass
rock/lava rock. The use of any glass rock/lava rock that is not factory­authorized can be dangerous and will void your warranty.
W Do NOT operate this appliance without reading “Operating Instructions”
in this manual.
W Storage of this outdoor fireplace indoors is permissible only if the tank
is disconnected, removed from the outdoor fireplace and properly stored outdoors.
W Do NOT attempt to disconnect the gas regulator from the tank or any
gas fitting while the outdoor fireplace is in use.
W If the outdoor fireplace is not in use, the gas must be turned off at the
supply tank.
W The pressure regulator is set for 11 inches of water column.
W The maximum inlet gas pressure for this outdoor fireplace is 11 inches
of water column.
W Before pressure testing, close LP gas tank valve and disconnect gas
regulator. The gas supply piping system must test at pressures equal to or less than ½ psi (3.5 kPa).
W Do NOT sit or stand on the mantle or any part of this appliance.
W Do NOT throw anything onto the fire when the unit is in operation.
W Fire logs, glass and lava rock are very hot. Keep children or pets at a
safe distance from this appliance.
W The opening of the tank collar should face toward the door side for easy
access.
W Do NOT store any combustible materials in the base enclosure.
W Use protective gloves when assembling this product.
W Do NOT force parts together as this can result in personal injury or
damage to the product.
W Death, serious injury or damage to property may occur if the above is
not followed exactly.
W This outdoor fireplace should be inspected at least annually by a
qualified service person. Depending on amount of use, more frequent cleaning may be required. Do NOT operate until all parts have been repaired or replaced.
4
LP Gas Outdoor Fireplace
®
Model No. GAD860SP
Parts List
Cement Log (4)
1
Lava Rock
2
Lava Rock Grid
3
Side Panel (6)
4
Bowl Assembly*
5
Burner*
6
Igniter*
7
Control Knob*
8
Regulator/Hose Assembly*
9
Hearth
10
Back Leg (2)
11
Middle Support Leg (3)
12
Tank Guard
13
55-05-432 55-05-433 55-05-434 55-05-435
55-05-443
55-05-444
58-05-028
55-05-430
55-05-431
55-05-441
55-05-436
55-05-452
58-05-025
55-05-694
55-05-702
55-05-458
Expanded View
4
1
2
3
4
5
6
7
10
9
25
8
4
4
LP Gas Tank Retaining
14
Chain
LP Gas Tank Tray Peg
15
Base Support Bar
16
Left Front Leg
17
Left Door
18
Door Support Leg
19
Right Door
20
Right Front Leg
21
Door Knob (2)*
22
Base*
23
LP Gas Tank Tray*
24
LP Gas Tank Shield
25
26
Foot (4)
55-05-447
55-05-449
55-05-429
55-05-700
58-05-026
55-05-698
58-05-027
55-05-704
55-05-697
55-05-428
55-05-448
55-12-704
55-05-692
11
11
13
12
16
4
12
14
12
4
26
15
26
21
19
20
17 18
23
26
24
26
22
Cover
27
* Pre-assembled
Hardware
A B C D
Screw
Screw
Screw
Wing Nut
55-05-693
M5x10 Black Nickel Plated Truss Head
M5x10 Black Nickel Plated Hex
ø4x16 Black Nickel Plated Truss Head
ø5 Black Nickel Plated
27
68 pcs
9 pcs
2 pcs
3 pcs
Tools Required for Assembly (Included)
M5 Allen Wrench
E
AA Battery
1.5 V AA Battery
1 pc
Tools Required for Assembly (Not Included)
#2 Phillips Head Screwdriver
Need help? 1.800.762.1142
Do not return to place of purchase.
Assembly Instructions
Replacement Parts
5
1.800.762.1142
1
DO NOT RETURN TO PLACE OF PURCHASE.
For assistance, call 1.800.762.1142 toll-free. Please have your Owner’s Manual and model number available for reference.
Note: The model number is printed on a label which can be found on the inside door, back or side of the base assembly.
Assembly Tips:
1. Select an area where you will assemble this product. To protect components, choose a smooth surface that’s free of cracks or openings.
2. Spread out all parts.
3. Tighten all hardware connections by hand first. Then, before completing each step, go back and fully tighten all hardware. Be careful not to over-tighten. That could damage surfaces or strip threads.
4. For best results, complete each step in the order presented.
To complete assembly you will need:
• (1) Leak detection solution (instructions on how to make the solution are included in the “Operating Instructions” section of this manual).
• (1) Precision-filled LP gas grill tank with Acme Type 1 external threaded valve connection (standard grill size) (not included).
Attach Bowl Assembly
Note: The control panel must line up with the two holes on the mantel frame.
2
3
Typical assembly is approximately one hour.
Attach LP Gas Tank Shield
4
A
Attach Side Panels, Back Legs and Middle Support Leg
x 4
A
x 4
A
x 12
B
x 3
6
Assembly Instructions (continued)
LP Gas Outdoor Fireplace
®
Model No. GAD860SP
5
Attach Side Panels, Left Front Leg and Middle Support Leg
Attach Side Panels, Right Front Leg and Middle Support Leg
6
7
A
Attach Base and Feet
x 12
B
x 2
A
Attach Door Support Leg
x 12
B
x 2
8
A
x 18
A
x 4
B
x 2
Need help? 1.800.762.1142
Do not return to place of purchase.
Replacement Parts
7
1.800.762.1142
9
Attach Tank Guard
Attach Base Support Bar
10
D
Attach Doors
11
x 3
12
A
Place Wood Grid and Lava Rocks
W CAUTION: Do NOT dump lava rocks out of package. Carefully
place lava rocks by hand so dust does not clog burner.
W CAUTION: Use only Blue Rhino Global Sourcing, Inc. factory-
authorized lava rock. The use of any lava rock that is not factory-authorized can be dangerous and will void your warranty.
W CAUTION: Do NOT cover pilot housing.
Note: Lava rocks should be 0.8-2.0 in. (2-5 cm) long. Approx. 5.95 lbs. (2.7 kg) of lava rocks are needed.
x 2
C
x 2
8
17.9 in. / 45.5 cm
12.2 in. / 31 cm
LP Gas Outdoor Fireplace
®
Model No. GAD860SP
Assembly Instructions (continued)
Place Cement Logs
13
Installing LP Gas Tank
To operate, you will need one precision-filled standard grill LP gas tank with external valve threads.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this outdoor fireplace.
Inserting LP Gas Tank
W WARNING: Make sure LP gas tank valve is closed.
Place precision-filled LP gas tank upright into hole in the base of the outdoor fireplace so the tank valve is facing the gas line connection.
20 lb
9 Kg
Insert Battery
Note: Remove plastic wrapper before installing battery.
14
Secure LP Gas Tank
Secure tank by sliding tank retainer chain around the LP gas tank and inserting peg into LP gas tank tray.
Note: Peg must be inserted into LP gas tank when tank is in LP gas tank tray.
Connecting LP Gas Tank
1. Before connecting, be sure there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner or burner ports.
2. Connect regulator/hose assembly to tank by turning knob clockwise until it stops.
E
Disconnecting LP Gas Tank
1. Before disconnecting, make sure the LP gas tank valve is “CLOSED.”
2. Disconnect regulator/hose assembly from LP gas tank by turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this grill.
3. Place the protective cap cover on the LP tank and store the tank outdoors in a well ventilated area out of direct sunlight.
x 1
BlueRhino.com
Available in U.S. only.
Need help? 1.800.762.1142
X
X
X
X
X
Do not return to place of purchase.
Operating Instructions
Replacement Parts
9
1.800.762.1142
Checking for Leaks
W WARNING: Before using this outdoor
fireplace, make sure you have read, understand and are following all information provided in the “Important Safeguards” section on page 2. Failure to follow those instructions can cause death, serious injury or property damage.
Figure 1
LP Gas Valve with Orifice
11. If ignition does not occur in 5 seconds, turn burner control knob to “ OFF,” wait
5 minutes, fan with a newspaper or magazine, and repeat lighting procedure.
12. If igniter does not light burner:
a. Wearing heat-resistant gloves, position a long lit match or long lit butane lighter near
the pilot housing.
b. Push and turn control knob to (LOW).
c. Remove match/lighter once burner is lit.
W CAUTION: After lighting - using a fireplace tool and heat-resistant
gloves, carefully move the glass rocks back to their proper position, being careful to avoid the flame.
Burner Connections
1. Make sure the regulator hose and valve connections are securely fastened to the burner and the tank.
2. Visually check the connection between the burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the orifice.
W WARNING: Failure to inspect
this connection or follow these instructions could cause a fire or an explosion which can cause death,
LP Gas Connection
Figure 2
13. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height matches illustration (Figure 5).
W CAUTION: If ignition does not occur in 5 seconds, turn control knob
to “
OFF,” wait 5 minutes, fan with a newspaper or magazine, and
repeat lighting procedure.
Turning Off
1. Turn LP gas tank valve to “CLOSED.”
2. Turn control knob to the “ Note: A “poof” sound is normal as the last of the LP gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
OFF” position.
serious bodily injury or damage to property.
4. Please refer to diagram for proper installation (Figures 1 and 2).
5. If the burner/venturi tube does not rest flush to the orifice, as shown, please contact
1.800.762.1142 for assistance.
Figure 3
OFF / ARRÊT
Cleaning and Care
W CAUTION:
1. All cleaning and maintenance should be done when outdoor fireplace is cool and with the fuel supply disconnected.
2. Do NOT clean any outdoor fireplace part in a self-cleaning oven.
Tank/Gas Line Connection
The extreme heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the
1. Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing soap with three parts water.
2. Make sure control knobs are in the “ position (Figure 3).
3. Connect LP gas tank per “Installing LP Gas Tank” section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt bottle, at all “X” locations (Figures 1, 2 and 4).
a. If any bubbles appear, turn LP gas tank valve
to “CLOSED,” reconnect and re-test.
b. If you continue to see bubbles after
several attempts, turn LP gas tank valve to “CLOSED” and disconnect LP gas tank, per “Disconnecting LP Gas Tank” section. Contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to “CLOSED,” wipe away solution and proceed.
OFF”
Lighting Instructions
W WARNING: NEVER light the burner
Figure 4
Figure 5
Notices
1. This outdoor fireplace should be thoroughly cleaned and inspected on a regular
2. Abrasive cleaners will damage this product.
3. NEVER use oven cleaner to clean any part of this outdoor fireplace.
Before Each Use
1. Keep the outdoor fireplace area clear and free from any combustible materials, gasoline,
2. Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air.
3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris.
4. Visually check the burner flames to make sure your outdoor fireplace is working properly
5. See below for proper cleaning instructions.
6. Check all gas connections for leaks.
7. Check components for any signs of damage or rust.
8. Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the
9. If damage to any component is detected, do NOT operate until repairs are completed.
valves or burners.
basis.
and other flammable vapors and liquids.
(Figure 5).
burner/venturi tube. A clogged burner/venturi tube can lead to a fire.
with the cover on the outdoor fireplace.
W CAUTION: Keep outdoor gas
appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of
combustion and ventilation air.
11.8 in. - 13.8 in. 30 - 35 cm
Cleaning Surfaces
1. Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.
2. For stubborn stains, use a citrus-based cleaner and a nylon scrubbing brush.
3. Rinse clean with water.
4. Allow to air dry.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1. Make sure all labels, packaging and protective films have been removed from the outdoor fireplace.
2. Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the burner/venturi tube. A clogged burner tube can lead to a fire.
3. Control knob must be in the “
4. Clear small area of glass rocks away from the igniter cover (Figure 4).
5. Connect LP gas tank per “Installing LP Gas Tank” section.
6. Turn LP gas tank valve to “OPEN.”
7. Push and turn control knob to
8. Continue to hold the control knob in, press the 5 seconds to light the pilot.
9. Continue to hold the control knob in for 20 seconds to heat thermocouple.
10. After 20 seconds, release and turn control knob counterclockwise to ignite burner and adjust flame to desired height.
OFF” position (Figure 3).
(LOW).
(electronic igniter) and hold for up to
Before Storing
1. Turn LP gas tank valve to “CLOSED.”
2. Turn control knob to the “ Note: A “poof” sound is normal as the last of the gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
4. Clean all surfaces.
5. Lightly coat the burner with cooking oil to prevent excess rusting.
W CAUTION: NEVER place cover on hot outdoor fireplace.
6. If storing the outdoor fireplace indoors, cover the outdoor fireplace and store in a cool dry location away from children and pets.
7. If storing the outdoor fireplace outdoors, cover the outdoor fireplace with a cover for protection from the weather.
OFF” position.
10
®
Product Registration
For faster warranty service, please register your product immediately. To register, go to BlueRhino.com/warranty or call 1.800.762.1142.
Replacement Parts
For replacement parts, visit parts.BlueRhino.com or call 1.800.762.1142.
Limited Warranty
Blue Rhino Global Sourcing, Inc. (“Blue Rhino”) warrants to the original retail purchaser of this product, and to no other person, that if this product is assembled, maintained, and operated in accordance with the printed instructions accompanying it, then for a period of one (1) year from the date of purchase, all parts in such product shall be free from defects in material and workmanship. Blue Rhino may require reasonable proof of your date of purchase. Therefore, you should retain your sales slip or invoice. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service and which Blue Rhino shall determine in its reasonable discretion upon examination to be defective. Before returning any parts, you should contact Blue Rhino’s Customer Care Department using the contact information listed below. If Blue Rhino confirms, after examination, a defect covered by this Limited Warranty in any returned part, and if Blue Rhino approves the claim, Blue Rhino will replace such defective part without charge. If you return defective parts, transportation charges must be prepaid by you. Blue Rhino will return replacement parts to the original retail purchaser, freight or postage prepaid.
This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance or service by you or any third party, or failure to perform normal and routine maintenance on the product as set out in this owner’s manual. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.
This Limited Warranty is in lieu of all other express warranties. Blue Rhino disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors, including the warranty of merchantability or the warranty of fitness for a particular purpose. Blue Rhino ALSO DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Blue Rhino SHALL HAVE NO LIABILITY TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Blue Rhino further disclaims any implied or express warranty of, and assumes no responsibility for, defects in workmanship caused by third parties.
This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some jurisdictions do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to everyone.
Blue Rhino does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on Blue Rhino.
Blue Rhino Global Sourcing, Inc. Winston-Salem, North Carolina 27105 USA
1.800.762.1142
LP Gas Outdoor Fireplace
Model No. GAD860SP
Need help? 1.800.762.1142
Do not return to place of purchase.
Troubleshooting
Problem Possible Cause Prevention/Cure
Make sure regulator is securely attached to the LP gas tank per “Installing LP Gas Tank,” then turn LP gas tank valve to “OPEN”
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Reconnect wire or replacement part(s) may be needed - contact Customer Care at 800.762.1142
Check if LP gas tank is empty
a. If empty, exchange, refill or replace LP gas tank b. If LP gas tank is not empty, refer to “Sudden drop in gas flow or
reduced flame height” (see below)
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Turn the coupling nut about one-half to three-quarters additional turn until solid stop. Tighten by hand only - do NOT use tools
1. Clear burner/venturi tube
2. Check for bent or kinked hose
Burner will not light using igniter
Burner will not light with match
LP gas tank valve is closed
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leak
Battery needs to be changed Replace the “AA” battery (follow assembly step for inserting battery)
Electrode and burners are wet Wipe dry with cloth
Electrode cracked or broken - sparks at crack Replacement part(s) may be needed - contact Customer Care at 800.762.1142
Wire loose or disconnected
Wire is shorting (sparking) between igniter and electrode Replacement part(s) may be needed - contact Customer Care at 800.762.1142
Bad igniter Replacement part(s) may be needed - contact Customer Care at 800.762.1142
No gas flow
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leak
Coupling nut and regulator not fully connected
Obstruction of gas flow
Disengagement of burner to valve Re-engage burner and valve
Spider webs or insect nest in burner/venturi tube Clean burner/venturi tube
Burner ports clogged or blocked Clean burner ports
Out of gas Exchange, refill or replace LP gas tank
Replacement Parts
11
1.800.762.1142
1. Turn control knob to “
2. Wait 30 seconds and light outdoor fireplace per “Lighting” section
3. If flames are still too low, reset the overfilling prevention device: a. Turn control knob(s) “
Sudden drop in gas flow or reduced flame height
Irregular flame pattern, flame does not run the full length of burner
Flame is yellow or orange
Flame goes out
Flashback (fire in venturi/burner tube(s)) Burner and/or burner/venturi tube is blocked Clean burner and/or burner/venturi tube
Flame seems to lose heat when burning in cold weather - temperature below 50ºF
Overfilling prevention device may have been activated
Burner ports are clogged or blocked Clean burner ports
New burner may have residual manufacturing oils Burn outdoor fireplace for 15 minutes and reinspect
Spider webs or insect nest in burner/venturi tube Clean burner/venturi tube
Poor alignment of valve to burner/venturi tube Ensure burner/venturi tube is properly engaged with valve
High or gusting winds Do not use outdoor fireplace in high winds
Low on LP gas Exchange, refill or replace LP gas tank
Excess flow valve tripped Refer to “Sudden drop in gas flow or reduced flame height”
Ice has built up on the outside of the LP gas tank because the vaporization process is too slow
For assistance, please visit us at BlueRhino.com or call 1.800.762.1142.
b. Turn LP gas tank valve to “CLOSED” c. Disconnect regulator d. Turn control knobs to e. Wait one minute f. Turn control knobs to “ g. Reconnect regulator and leak check connections, being careful not to
fully open valve
h. Light outdoor fireplace per “Lighting” section
1. Turn off per “Turning Off” section
2. Replace with a spare LP gas tank
3. Reconnect LP gas tank per “Installing LP Gas Tank” section
4. Follow “Checking for Leaks” section
5. Light outdoor fireplace per “Lighting” section
OFF”
OFF”
(HIGH)
OFF”
12
LP Gas Outdoor Fireplace
®
Model No. GAD860SP
Loading...