The use and installation of this product must conform to local codes. In absence of local codes, use the
latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or International Fuel Gas Code. This
appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence
of local codes with the National Electrical Code, ANSI/NFPA 70, if applicable.
THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ AND KEEP
FOR FUTURE REFERENCE.
If you are assembling this unit for someone else, give this manual to them to read and save for future
reference.
California Proposition 65: Combustion by-products produced when using this product contain chemicals
known to the State of California to cause cancer, birth defects, and other reproductive harm.
California Proposition 65: Wash your hands after handling this product.
California Proposition 65: Handling the brass material on this product exposes you to lead, a chemical
known to the State of California to cause cancer, birth defects, or other reproductive harm.
1. Do NOT store or use gasoline or other
flammable vapors or liquids in the vicinity of
this or any other appliance.
2. An LP-cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
DANGER
Do NOT leave this appliance unattended while
it is in operation.
is a Registered Trademark of Blue Rhino Global Sourcing, Inc. GAD860SP-E-OM-F107
Made from 75% Bagasse
(environmentally friendly sugar
cane pulp by-product)
2
®
LP Gas Outdoor Fireplace
Model No. GAD860SP
Important Safeguards
W DANGER: Failure to follow the dangers, warnings and cautions in this manual may result in serious bodily injury or death, or in a fire or an explosion
causing damage to property.
W WARNINGS:
W This appliance is for outdoor use only, and should NOT be used in a
building, garage or any other enclosed area.
W Do NOT operate, light or use this appliance within ten feet (3.05 m) of
walls, structures or buildings.
W For residential use only. This outdoor fireplace is NOT for commercial
use.
W Do NOT use this outdoor fireplace for indoor heating. TOXIC carbon
monoxide fumes can accumulate and cause asphyxiation.
W This outdoor fireplace is safety certified for use in the United States
and/or Canada only. Do NOT modify for use in any other location.
Modification will result in a safety hazard and will void your warranty.
W Apartment dwellers: Check with management to learn the requirements
and fire codes for using a liquid propane (LP) gas outdoor fireplace in
your apartment complex. If allowed, use outside on the ground floor
with a ten foot (3.05 m) clearance from any structure. Do NOT use on or
under balconies.
W This outdoor fireplace, from the factory, is for use with LP gas only. The
conversion to or attempted use of natural gas in this outdoor fireplace is
dangerous, may cause bodily harm and will void your warranty.
W LP gas characteristics:
a. LP gas is flammable and hazardous if handled improperly. Become
aware of the characteristics before using any LP gas product.
b. LP gas is explosive under pressure, heavier than air, and settles/
pools in low areas.
c. LP gas in its natural state has no odor. For your safety, an odorant is
added that smells like rotten cabbage.
d. Contact with LP gas can cause freeze burns to skin.
W Your outdoor fireplace has been checked at all factory connections
for leaks. Recheck all connections as described in the “Operating
Instructions” section, as shipping can loosen connections.
W Check for leaks even if your unit was assembled for you by someone
else.
W Do NOT operate if a gas leak is present. Gas leaks may cause a fire or
explosion.
W You must follow all instructions in the “Checking for Leaks” section
before operating. To prevent a fire or explosion when testing for a leak:
a. Always perform a leak test before lighting this outdoor fireplace and
each time the tank is connected for use.
b. No smoking. Do NOT use or permit sources of ignition in the area
while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do NOT use matches, lighters or a flame to check for leaks.
e. The use of alcohol, prescription or non-prescription drugs may
impair the consumer’s ability to properly assemble or safely operate
the appliance.
f. Strong odors, colds, sinus congestion, etc. may prevent the
detection of propane. Use caution and common sense when testing
for leaks.
g. Do NOT use this outdoor fireplace until any and all leaks are
corrected.
If you are unable to stop a leak, disconnect the LP gas supply. Call a
gas appliance serviceman or your local LP gas supplier.
W Do NOT store or use gasoline or other flammable liquids or vapors
within 25 feet (7.62 m) of this appliance.
W LP gas tank needed to operate. Only tanks marked “propane” may be
used.
a. The LP gas cylinder must be constructed and marked in accordance
with the U.S. Department of Transportation (D.O.T.) Specifications for
LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes
for the Transportation of Dangerous Goods and Commission, CAN/
CSA-B339 as applicable.
b. LP gas tank must be arranged for vapor withdrawal.
c. The LP gas tank must have a listed overfilling prevention device
(OPD) and a QCCI or Type I (CGA810) LP gas tank connection.
d. The LP gas tank must have a tank collar to protect the tank valve.
e. Never use an LP gas tank with a damaged body, valve, collar or
footing.
f. Dented or rusted LP gas tanks may be hazardous and should be
checked by your LP gas supplier prior to use.
g. The LP gas tank should not be dropped or handled roughly.
h. Tanks must be stored outdoors, out of the reach of children and
must not be stored in a building, garage or any other enclosed area.
Your LP gas tank must never be stored where temperatures can
reach over 125°F.
i. Do NOT insert any tool or foreign object into the valve outlet or
safety relief valve. You may damage the valve and cause a leak.
Leaking propane may result in explosion, fire, severe personal injury
or death.
j. Never keep an LP gas tank in a hot car or trunk. Heat will cause the
gas pressure to increase, which may open the relief valve and allow
gas to escape.
k. Place dust cap on cylinder valve outlet whenever the cylinder is not
in use. Only install the type of dust cap on the cylinder valve outlet
that is provided with the cylinder valve. Other types of caps or plugs
may result in leakage of propane.
l. Do NOT store a spare LP gas tank under or near this appliance.
m. Never fill the cylinder beyond 80 percent full.
n. A fire causing serious injury or damage to property may occur if the
above is not followed exactly.
W Do NOT use in an explosive atmosphere. Keep outdoor fireplace
area clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
W This outdoor fireplace is NOT to be operated by children.
W This outdoor fireplace is NOT to be used in or on boats or recreational
vehicles.
W Do NOT connect to a remote gas supply.
W Never attempt to attach this outdoor fireplace to the self-contained LP
gas system of a camper trailer, motor home or house.
W Always use in accordance with all applicable local, state and national
codes. Contact your local fire department for details on outdoor burning.
W When using this outdoor fireplace, exercise the same precautions you
would with any open fire.
W Do NOT use this outdoor fireplace without reading the entire Owner’s
Manual.
W Do NOT burn solid fuels such as: wood, charcoal briquettes, lump
charcoal, manufactured logs, driftwood, trash, leaves, paper, cardboard,
plywood, painted/stained/pressure treated wood in this outdoor
fireplace.
W It is essential to keep the outdoor fireplace’s valve compartment,
burners, and circulating air passages clean. Inspect outdoor fireplace
before each use.
W Do NOT use this outdoor fireplace until it is COMPLETELY assembled and
all parts are securely fastened and tightened.
W Do NOT use this outdoor fireplace near automobiles, trucks, vans or
recreational vehicles.
W Do NOT use this outdoor fireplace under any overhang or near any
unprotected combustible constructions. Avoid using near or under
overhanging trees and shrubs.
W Always use this outdoor fireplace on a hard, level, non-combustible
surface such as concrete, rock or stone. An asphalt or blacktop surface
may not be acceptable for this purpose.
W Do NOT use this outdoor fireplace for cooking.
Need help? 1.800.762.1142
Do not return to place of purchase.
Replacement Parts
3
1.800.762.1142
W Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part or control system and any gas control which
has been under water.
W Do NOT wear flammable or loose clothing when operating this outdoor
fireplace.
W Do NOT use in windy conditions.
W Never lean over this outdoor fireplace when lighting or when in use.
W Do NOT use this outdoor fireplace unless burner is securely in place.
W Keep all electrical cords away from this outdoor fireplace during use.
W Certain areas of this outdoor fireplace when in use will become too
hot to touch. To avoid burns, do NOT touch hot surfaces until the unit
has completely cooled (about 45 minutes), unless you are wearing
protective gear (such as insulated pot holders or heat-resistant gloves/
mittens).
W Do NOT leave a lit outdoor fireplace unattended, especially around
children and pets.
W Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burns or clothing ignition.
W Young children should be carefully supervised when they are in the area
of the appliance.
W Do NOT hang or place clothing or other flammable material on or near
this appliance.
W Any guard or other protective device removed for servicing the
appliance must be replaced prior to operating the appliance.
W If applicable, protective cover must be removed when burner is in
operation.
W Do NOT attempt to move outdoor fireplace when in use. Allow the
outdoor fireplace to cool before moving or storing.
W This outdoor fireplace should be thoroughly cleaned and inspected on a
regular basis.
a. Clean and inspect the hose before each use of the appliance. If
there is evidence of abrasion, wear, cuts, or leaks, the hose must be
replaced prior to the appliance being operated. Use only the hose
specified by Blue Rhino Global Sourcing, Inc.
b. Inspect the burner before each use of the appliance. If there is
evidence of burner damage, the burner must be replaced prior to
the appliance being operated. Use only the burner specified by Blue
Rhino Global Sourcing, Inc.
W Use only the regulator and hose assembly provided. Use only the
replacement regulator and hose assembly specified by Blue Rhino
Global Sourcing, Inc.
W Use only the burner provided. Use only the replacement burner specified
by Blue Rhino Global Sourcing, Inc.
W Use only Blue Rhino Global Sourcing, Inc. factory-authorized parts. The
use of any part that is not factory-authorized can be dangerous and will
void your warranty.
W Use only Blue Rhino Global Sourcing, Inc. factory-authorized glass
rock/lava rock. The use of any glass rock/lava rock that is not factoryauthorized can be dangerous and will void your warranty.
W Do NOT operate this appliance without reading “Operating Instructions”
in this manual.
W Storage of this outdoor fireplace indoors is permissible only if the tank
is disconnected, removed from the outdoor fireplace and properly stored
outdoors.
W Do NOT attempt to disconnect the gas regulator from the tank or any
gas fitting while the outdoor fireplace is in use.
W If the outdoor fireplace is not in use, the gas must be turned off at the
supply tank.
W The pressure regulator is set for 11 inches of water column.
W The maximum inlet gas pressure for this outdoor fireplace is 11 inches
of water column.
W Before pressure testing, close LP gas tank valve and disconnect gas
regulator. The gas supply piping system must test at pressures equal to
or less than ½ psi (3.5 kPa).
W Do NOT sit or stand on the mantle or any part of this appliance.
W Do NOT throw anything onto the fire when the unit is in operation.
W Fire logs, glass and lava rock are very hot. Keep children or pets at a
safe distance from this appliance.
W The opening of the tank collar should face toward the door side for easy
access.
W Do NOT store any combustible materials in the base enclosure.
W Use protective gloves when assembling this product.
W Do NOT force parts together as this can result in personal injury or
damage to the product.
W Death, serious injury or damage to property may occur if the above is
not followed exactly.
W This outdoor fireplace should be inspected at least annually by a
qualified service person. Depending on amount of use, more frequent
cleaning may be required. Do NOT operate until all parts have been
repaired or replaced.
4
LP Gas Outdoor Fireplace
®
Model No. GAD860SP
Parts List
Cement Log (4)
1
Lava Rock
2
Lava Rock Grid
3
Side Panel (6)
4
Bowl Assembly*
5
Burner*
6
Igniter*
7
Control Knob*
8
Regulator/Hose Assembly*
9
Hearth
10
Back Leg (2)
11
Middle Support Leg (3)
12
Tank Guard
13
55-05-432
55-05-433
55-05-434
55-05-435
55-05-443
55-05-444
58-05-028
55-05-430
55-05-431
55-05-441
55-05-436
55-05-452
58-05-025
55-05-694
55-05-702
55-05-458
Expanded View
4
1
2
3
4
5
6
7
10
9
25
8
4
4
LP Gas Tank Retaining
14
Chain
LP Gas Tank Tray Peg
15
Base Support Bar
16
Left Front Leg
17
Left Door
18
Door Support Leg
19
Right Door
20
Right Front Leg
21
Door Knob (2)*
22
Base*
23
LP Gas Tank Tray*
24
LP Gas Tank Shield
25
26
Foot (4)
55-05-447
55-05-449
55-05-429
55-05-700
58-05-026
55-05-698
58-05-027
55-05-704
55-05-697
55-05-428
55-05-448
55-12-704
55-05-692
11
11
13
12
16
4
12
14
12
4
26
15
26
21
19
20
1718
23
26
24
26
22
Cover
27
* Pre-assembled
Hardware
A
B
C
D
Screw
Screw
Screw
Wing Nut
55-05-693
M5x10 Black Nickel Plated Truss Head
M5x10 Black Nickel Plated Hex
ø4x16 Black Nickel Plated Truss Head
ø5 Black Nickel Plated
27
68 pcs
9 pcs
2 pcs
3 pcs
Tools Required for Assembly (Included)
M5 Allen Wrench
E
AA Battery
1.5 V AA Battery
1 pc
Tools Required for Assembly (Not Included)
#2 Phillips Head Screwdriver
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.