Endless Pools SwimCross Owner's Manual

SwimCross™ Exercise Systems
OWNER'S MANUAL
by Endless Pools
®
WELCOME
Watkins Manufacturing Corporation congratulates you on your decision to enjoy the finest SWIMCROSS Exercise System available. Welcome to the growing family of SWIMCROSS Exercise System by ENDLESS POOLS owners.
This Owner’s Manual will acquaint you with the operation and general maintenance of your new SWIMCROSS Exercise System. We suggest that you take some time to carefully review all sections. Please keep this manual available for reference.
If you have questions about any aspect of your SWIMCROSS Exercise System’s set-up, operation or maintenance, contact your authorized ENDLESS POOLS dealership. They are trained professionals who are familiar with the product, as well as new SWIMCROSS Exercise System ownership concerns. Their expertise will facilitate the enjoyment of your new SWIMCROSS Exercise System.
The serial number/identification label is located within the equipment compartment of your SWIMCROSS Exercise System. The serial number should also be documented on the delivery receipt from your dealer.
IMPORTANT: Watkins Manufacturing Corporation reserves the right to change specifications, or design, without notification and without incurring any obligation.
DATE PURCHASED: ___________________________________
DATE INSTALLED: _____________________________________
DEALER: ____________________________________________
ADDRESS: ___________________________________________
TELEPHONE: _________________________________________
MODEL/SERIAL NUMBER: ______________________________
COVER SERIAL NUMBER: ______________________________
In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to the SWIMCROSS Exercise System by children. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your ENDLESS POOLS dealer can provide information on which permits may be required.
TABLE OF CONTENTS
SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS .............................. 1
IMPORTANT SWIMCROSS EXERCISE SYSTEM
INSTRUCTIONS ..................................................................... 3
SITE REQUIREMENTS
INDOOR CONSIDERATIONS ............................................... 4
OUTDOOR CONSIDERATIONS ........................................... 4
ELECTRICAL REQUIREMENTS
230 VOLT PERMANENTLY CONNECTED .......................... 5
EQUIPMENT COMPARTMENT ............................................ 6
DOOR PANEL REMOVE & REPLACE ................................. 6
GETTING STARTED
MAIN SWIMCROSS EXERCISE SYSTEM FEATURES ..... 7
HYDROMASSAGE JETS....................................................... 8
SWIM JETS ............................................................................. 8
WATERFALL VALVE ............................................................... 8
AIR CONTROLS ..................................................................... 8
WATER QUALITY AND MAINTENANCE
BASIC INFORMATION ......................................................... 14
CHEMICAL SAFETY ...........................................................14
HOW TO ADD CHEMICALS
TO THE WATER.................................................................... 14
FUNDAMENTALS OF
WATER MAINTENANCE ..................................................... 14
THE ENDLESS POOLS WATER MAINTENANCE
PROGRAM ............................................................................ 16
VACATION WATER CARE INSTRUCTIONS ..................... 17
GLOSSARY ........................................................................... 18
CARE AND MAINTENANCE
FILTER MAINTENANCE ...................................................... 19
FILTER CARTRIDGE REMOVAL AND CLEANING
INSTRUCTIONS ................................................................... 19
DRAINING YOUR SWIMCROSS EXERCISE SYSTEM ... 20
PREVENTION OF FREEZING ............................................ 20
WINTERIZING YOUR SWIMCROSS EXERCISE
SYSTEM ................................................................................ 20
QUICK START-UP INSTRUCTIONS .................................... 8
OPERATING INSTRUCTIONS
CONTROL PANEL ................................................................ 10
SETTINGS ............................................................................. 10
AUDIO IN.STREAM (OPTIONAL) ....................................... 12
TEMPERATURE CONTROL ..............................................12
JETS CONTROL ................................................................... 13
LIGHT CONTROL ................................................................. 13
FILTER CYCLES ................................................................... 13
ALL OFF / MEMORY ON ..................................................... 13
WI-FI IN.TOUCH™ (OPTIONAL) .......................................13
CARE OF THE PILLOWS ................................................... 20
CARE OF THE EXTERIOR ..................................................21
SERVICE INFORMATION
GENERAL INFORMATION .................................................. 22
GFCI AND HIGH LIMIT THERMOSTAT .............................. 22
MISCELLANEOUS SERVICE INFORMATION .................. 22
ACTS INVALIDATING WARRANTY .................................... 22
DISCLAIMERS ...................................................................... 23
WATKINS CUSTOMER SERVICE ...................................... 23
TROUBLESHOOTING ......................................................... 23
Safety InformatIon
NO DIVING
IMPORTANT SAFETY INSTRUCTIONS
(READ AND FOLLOW ALL
Danger: Diving May Result in serious injury or death.
• Do not connect any auxiliary components (for example, cable,
INSTRUCTIONS)
• Do not self service the audio component by opening or removing
AVOIDING THE RISK TO CHILDREN
DANGER - RISK OF CHILD DROWNING
Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use a
SWIMCROSS Exercise System unless they are supervised at all times.
WARNING
To reduce the risk of injury, do not permit children to use this SWIMCROSS Exercise System unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.
• Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use the SWIMCROSS Exercise System unless they are supervised at all times.
DO:
• Make sure you always lock any child resistant locks after using the SWIMCROSS Exercise System for your children’s safety.
• Test the water temperature with your hand before allowing children to enter the SWIMCROSS Exercise System to be sure that it’s comfortable.
• Remind children that wet surfaces can be very slippery. Make sure that children are careful when entering or exiting the SWIMCROSS Exercise System.
DON'T:
• Allow children to climb onto a SWIMCROSS Exercise System cover.
• Allow children to have unsupervised access to the SWIMCROSS Exercise System.
AVOIDING THE RISK OF ELECTROCUTION
DANGER - RISK OF ELECTROCUTION
• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death, or serious personal injury due to electrocution if direct burial-type cable is not used, or if improper digging occurs.
• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 6 AWG (16 mm²) solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit as needed to comply with local requirements.
• Do not attach an external antennae to a SWIMCROSS Exercise
• To reduce the risk of electrical shock, replace a damaged cord
• Your SWIMCROSS Exercise System is provided with a Ground
• Install at least 5 feet (1.5 m) from all metal surfaces. A SWIMCROSS
additional speakers, headphones, additional audio components) to the audio system unless approved by Watkins Manufacturing Corporation
SWIMCROSS Exercise System door panel as this may expose dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel.
System audio system unless installed by a licensed electrician in accordance with Article 810 of the National Electric Code, ANSI/NFPA
70.
WARNING
immediately. Failure to do so may result in death or serious personal injury due to electrocution.
Fault Circuit Interrupter (GFCI) for user and equipment protection. To ensure proper operation of this important safety device, test according to the following instructions:
• A ground terminal is provided inside the junction box. To reduce the risk of electric shock, connect this terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated copper wire. The wire must be equivalent in size to the circuit conductors supplying the equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of the control box/heater for bonding to local ground points. To reduce the risk of electric shock, this connector should be bonded with a No. 6 AWG (16 mm²) solid copper wire to any metal ladders, water pipes, or other metal within 5 feet (1.5 m) of the SWIMCROSS Exercise System to comply with local requirements. The means of disconnection must be readily accessible, but must be installed at least 5 feet (1.5 m) from the
SWIMCROSS
• Your SWIMCROSS Exercise System is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.
• Your SWIMCROSS Exercise System uses ground fault circuit interrupters in the electrical subpanel. Before each use of the SWIMCROSS Exercise System and with the unit operating, push the TEST button on each breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off and then completely on. The switch should then stay on. If either of the interrupters does not perform in this manner, it is an indication of an electrical malfunction and the possibility of an electric shock. Disconnect the power until the fault has been identified and corrected.
Exercise System.
DANGER - RISK OF ELECTRICAL SHOCK
Exercise System may be installed within 5 feet of a metal surface if each metal surface is permanently connected by a minimum No. 8 AWG (10 mm²) solid copper conductor attached to the wire ground
Safety Information
Page 1
connector on the heater terminal block that is provided for this purpose.
• Install your SWIMCROSS Exercise System is such a way that drainage is away from the electrical compartment and from all electrical components.
• Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5 m) of a SWIMCROSS Exercise System. Failure to maintain a safe distance may result in death, or serious personal injury due to electrocution, if the appliance should fall into the SWIMCROSS Exercise System.
DO:
• Be sure your SWIMCROSS Exercise System is connected to the power supply correctly - use a licensed electrical contractor.
• Disconnect the SWIMCROSS Exercise System from the power supply before draining the SWIMCROSS Exercise System or servicing the electrical components.
• Test the Ground Fault Circuit Interrupter(s) before each use.
• Replace audio components only with identical components (if your SWIMCROSS Exercise System is equipped with an audio
component).
DON'T:
• Use the SWIMCROSS Exercise System with the equipment compartment door removed.
• Place electrical appliances within 5 feet (1.5m) of the SWIMCROSS Exercise System.
• Use an extension cord to connect the SWIMCROSS Exercise System to its power source. The cord may not be properly grounded and the connection is a shock hazard. An extension cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor damage.
• Attempt to open the electrical control box. There are no user serviceable parts inside.
INCREASED SIDE EFFECTS OF MEDICATION
• The use of drugs or alcohol may cause unconsciousness with the possibility of drowning.
• Persons using medications should consult a physician before using a SWIMCROSS Exercise System; some medication may cause a user to become drowsy, while other medication may affect heart rate, blood pressure, and circulation.
• Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines, or anticoagulants should not use the
SWIMCROSS Exercise System.
HEALTH PROBLEMS AFFECTED BY SWIMCROSS EXERCISE SYSTEM USE
• Pregnant women should consult a physician before using SWIMCROSS Exercise System.
• Persons suffering from obesity, or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using SWIMCROSS Exercise System.
UNCLEAN WATER
• Keep the water clean and sanitized with correct chemical care. The recommended levels for your ENDLESS POOLS SWIMCROSS Exercise System are:
Free Available Chlorine:
1.0-5.0 ppm
Water pH:
7.2-7.8
Total Alkalinity:
80-120 ppm
Calcium Hardness:
50-150 ppm
RISKS TO AVOID
DANGER - RISK OF INJURY
• To reduce the risk of injury to persons, DO NOT remove suction fittings (filter standpipes) located in the filter compartment.
• The suction fittings in the SWIMCROSS Exercise System are sized to match the specific water flow created by the pump. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting.
• There is a danger of slipping and falling. Remember that wet surfaces can be very slippery. Take care when entering or exiting the SWIMCROSS Exercise System.
• Never operate SWIMCROSS Exercise System if the suction fittings are broken or missing.
• People with infectious diseases should not use the SWIMCROSS Exercise System.
• Keep any loose articles of clothing, long hair, or hanging jewelry away from rotating jets or other moving components. Long hair should be tied up or placed under a bathing cap.
• Safe water temperature for aquatic exercise is approximately 85°F (29.5°C).
• DO NOT use this SWIMCROSS Exercise System alone.
• Refer to Water Quality and Maintenance section for complete instructions.
IMPORTANT: Turn on the jet pump for a least ten minutes after adding ANY SWIMCROSS Exercise System water chemicals into the filter compartment.
Clean the filter cartridges monthly to remove debris and mineral buildup which may affect the performance of the hydromassage jets, limit the flow, or trip the high limit thermostat, which will turn off the entire
SWIMCROSS Exercise System.
AVOIDING THE RISK OF HYPERTHERMIA
Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs when the internal temperature of the body reaches a level above normal 98.6°F (37°C). The symptoms of hyperthermia include unawareness of impending hazard, failure to perceive heat, failure to recognize the need to exit the SWIMCROSS Exercise System, physical inability to exit the SWIMCROSS Exercise System, fetal damage in pregnant women, and unconsciousness resulting in a danger of drowning.
WARNING
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in SWIMCROSS Exercise Systems.
Page 2
Safety Information
TO REDUCE THE RISK OF INJURY
• The water in the SWIMCROSS Exercise System should never exceed 104°F (40°C). Water temperatures between 79°F and 104°F (26°C and 40°C) are considered safe for a healthy adult. The lower water temperatures are recommended for extended use (exceeding ten minutes) and for young children. Extended use can cause hyperthermia.
• Pregnant or possibly pregnant women should limit SWIMCROSS Exercise System water temperatures to 85°F (29.5°C) consult a physician prior to using this product. Failure to do so may result in permanent injury to your baby.
• Do not use SWIMCROSS Exercise System having water temperatures over 100°F (36°C) immediately following strenuous exercise.
• Keep all breakables, especially glass, away from this SWIMCROSS Exercise System.
• Never insert any objects into any openings.
• Keep all chemicals away from children and pets.
• DO NOT stack chemicals on top of one another.
• NEVER MIX CHEMICALS.
• Sanitizing chemicals must be stored separately from balancing chemicals.
AVOIDING THE RISK OF SKIN BURNS
DON'T:
• Leave the SWIMCROSS Exercise System exposed to the sun without water or a cover in place. Exposure to direct sunlight can cause solar distress of the shell material.
• Roll or slide the SWIMCROSS Exercise System on its side. This will damage the siding.
• Lift or drag the vinyl cover by using the cover lock straps; always lift or carry the cover by using the handles.
• Attempt to open the electrical control box. There are no user serviceable parts inside. Opening of the control box by the SWIMCROSS Exercise System owner will void the warranty. If you have an operational problem, carefully go through the steps outlined in the Troubleshooting section. If you are not able to resolve the problem, contact your authorized ENDLESS POOLS dealer. Many problems can easily be diagnosed over the telephone by an Authorized Service Technician.
SWIMCROSS EXERCISE SYSTEM SHELL
Your SWIMCROSS Exercise System has an acrylic shell. Stains and dirt generally will not adhere to your SWIMCROSS Exercise System’s surface. A soft rag should easily remove most dirt. Most household chemicals are harmful to your SWIMCROSS Exercise System’s shell (see below for detailed information on cleaning agents). Always rinse off any SWIMCROSS Exercise System shell cleaning agent with fresh water.
• To reduce the risk of injury, before entering a SWIMCROSS Exercise System the user should measure the water temperature with an accurate thermometer.
• Test the water with your hand before entering the SWIMCROSS Exercise System to be sure it’s comfortable.
SAFETY SIGN
Each ENDLESS POOLS SWIMCROSS Exercise System is shipped with a SAFETY SIGN in the owner’s package. The sign, which is required as a condition of Product Listing, should be permanently installed where it is visible to the users of the SWIMCROSS Exercise System. To obtain additional SAFETY SIGNS, contact your ENDLESS POOLS dealer. Safety labels that are affixed to the shell are intended to be permanent and should not be removed.
IMPORTANT SWIMCROSS EXERCISE SYSTEM INSTRUCTIONS
The following contains important SWIMCROSS Exercise System information, and we strongly encourage you to read and apply them.
IMPORTANT:
1. The following products are the ONLY approved cleaning agents for your SWIMCROSS Exercise System shell: plain water, Brillianize® or Soft Scrub®. The use of alcohol or any other household cleaner other than those listed to clean the SWIMCROSS Exercise System shell surface is NOT recommended. DO NOT use any cleaning products containing abrasives or solvents since they may damage the shell surface, specifically: Simple Green NEVER USE HARSH CHEMICALS! Damage to the shell by use of harsh chemicals is not covered under the warranty. Always rinse off any SWIMCROSS Exercise System shell cleaning agent with fresh water.
2. Iron and copper in the water can stain the SWIMCROSS Exercise System shell if allowed to go unchecked. Ask your ENDLESS
POOLS dealer about a Stain and Scale Inhibitor to use if your SWIMCROSS Exercise System has a high concentration of
dissolved minerals.
3. Keep all cleaners out of the reach of children and use care when applying.
®
, Windex® or spa Mitt.
DO:
• Follow the SWIMCROSS Exercise System Care and Maintenance recommendations stated in this manual.
• Use only approved accessories and recommended SWIMCROSS Exercise System chemicals and cleaners.
SAVE THESE INSTRUCTIONS
Page 3Safety Information
SIte requIrementS
Your
SWIMCROSS
and level surface that can support 190 lbs per square foot.
If a new slab is poured, consult your local electrical codes regarding grounding and bonding. Local code may require a bonding wire to be attached to the reinforcing bar or wire mesh that is embedded in the concrete. If new concrete is being poured, this is the ideal time to install the conduit for the incoming electrical supply.
Even if a new pad has been poured, it is essential that the system site is level and planar. There is a simple way to ensure that this is the case. First, draw a chalk outline of the footprint of your Exercise System. Place a six-foot level along and around the footprint of the system. Verify that there are no gaps between the level and floor. Next pour water inside of the chalk footprint. Verify that the water does not puddle inside the footprint.
Should there a be a gap or should the water puddle inside the footprint, call your ENDLESS POOLS dealer prior to continuing to discuss the best way to resolve this situation.
INDOOR CONSIDERATIONS
1. Local electrical and plumbing codes.
2. Ventilation fans and/or dehumidifiers should be provided to handle the humidity developed by your Walls, ceiling and wood trim should be water resistant, also.
3. Chemicals will vaporize from the water and may cause an odor and possibly corrosion to certain home hardware. Never store chemicals inside the
4. During the normal use of the water will escape the vessel. Never place on or over any materials, which may be damaged by this water or the chemicals within the water. Keep damageable materials far enough away to avoid water damage, even if the all its water.
5. Consider and prepare for the unlikely event of rapid drainage. If placement of the you may wish to provide floor drains to accommodate draining, etc. Always leave room all around the for easy access in case repairs are necessary.
6. Consider and prepare for the unlikely event of removal.
7. Do not set without a waterproof barrier protection underneath.
8. The
9. The
10. Be sure that the location you choose is stable. It must be able
11. Do not use the
SWIMCROSS
power source capable of supplying 230 volts AC power. It must be wired directly into a grounded circuit with a ground fault circuit interrupter (GFCI). No other appliances should be on the same circuit.
SWIMCROSS
of water.
to support the weight of the when it is filled with water, plus the weight of the occupants. The
SWIMCROSS
(8,265 kg) when it is filled with water.
living area due to the risk of water damage.
Exercise System must be installed on a smooth
SWIMCROSS
SWIMCROSS
SWIMCROSS
Exercise System cabinet.
SWIMCROSS
SWIMCROSS
SWIMCROSS
Exercise System should lose
Exercise System is permanent,
SWIMCROSS
SWIMCROSS
Exercise System on finished floor
Exercise System should have access to a
Exercise System should be close to a source
SWIMCROSS
Exercise System may weigh up to 18,185 lbs
SWIMCROSS
Exercise System above a finished
Exercise System.
Exercise System,
Exercise System
Exercise System
12. The
SWIMCROSS
Exercise System is not designed for in-floor
installation. However, it is compatible with a deck system that is built flush with the bar top, provided you leave access for service.
13. Be sure to note any other considerations, such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the
SWIMCROSS
Exercise System.
OUTDOOR CONSIDERATIONS
1. Local electrical and plumbing codes.
2. Consider local codes pertaining to fencing, enclosures, walls, electrical and plumbing. You will need to ensure that your
SWIMCROSS
from power lines, both above ground and underground. Your
SWIMCROSS
3. View from house for aesthetics and supervisory needs.
4. Distance from house for wintertime soaking.
5. Nighttime lighting.
6. Consider sunlight exposure, views, access, property lines, lighting, wind direction, shielding, septic tanks, plants, and trees when determining your location. Chemicals in the Exercise System water may splash damaging nearby plant life.
7. If your second story, be positive support is adequate. Call your builder and a structural engineer.
8. Area for placement of support equipment where adequate space will be needed to gain access to components for maintenance and general servicing.
9. Be sure to note any other considerations, such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the
SWIMCROSS
10. Provide adequate drainage away from the equipment and adequate elevation to allow draining by siphon, if should be required.
11. Location of electrical supply. 230-volt systems require hard wire installed from the main electrical source, to the sub panel, then to the
SWIMCROSS
must be ground fault circuit protected (NOT SUPPLIED) . All electrical wiring must comply with the national electric code.
12. Locations at least 5 ft (1.52 m) from all metal surfaces. A
SWIMCROSS
of metals surfaces providing each metal surface is permanently connected by a no. 8 awg (8.4 mm2) copper conductor attached to the bonding wire connector on the heater provided for this purpose. All installations must comply with article 680 of the U.S. national electric code and ANSI/NFPA 70-1984.
13. Place the that will not shift.
Exercise System is an adequate distance
Exercise System will also need to be child proofed.
SWIMCROSS
SWIMCROSS
SWIMCROSS
Exercise System is to be located on a
Exercise System.
Exercise System terminal block. All equipment
Exercise System may be installed within 5 feet
Exercise System on a firm, level surface
Page 4
Site Requirements
electrIcal requIrementS
IMPORTANT
turning on the power.
Your ENDLESS POOLS SWIMCROSS Exercise System has been carefully designed to give you maximum safety against electrical shock. Connecting the SWIMCROSS Exercise System to an improperly wired circuit will negate many of the SWIMCROSS Exercise System’s safety features. Improper wiring may also cause electrocution, risk of fire, and other risks of injuries. Please read and follow the electrical installation requirements and instructions completely!
230 VOLT PERMANENTLY CONNECTED
ENDLESS POOLS SWIMCROSS Exercise Systems must be wired in accordance with all applicable local electrical codes. All electrical work should be done by an experienced, licensed electrician. We recommend the use of appropriate electrical conduit, fittings, and wire for all circuits.
The diagram below illustrates how to wire the SWIMCROSS Exercise System model:
• An electrical subpanel containing a 60 Amp breaker is included with your SWIMCROSS Exercise System. We recommend that this subpanel be used to supply power to the SWIMCROSS Exercise System.
The subpanel requires a 60 amp, single phase, 230 volt, four
: Fill the SWIMCROSS Exercise System with water before
wire service (two line, one neutral, one ground). The grounding conductor must not be less than #6 AWG. Refer to local codes and
to NEC 250-122 (table).
Mount the subpanel in the vicinity of the SWIMCROSS Exercise System, but not closer than five local codes. (N.E.C. 680-38 to 41-A-3)
Open SWIMCROSS Exercise System by removing the 4 screws holding the vertical T-spacer located in the center of the equipment compartment (back side of SWIMCROSS Exercise System). Slide panel towards center and remove, repeat for other panel.
Insert power wires into SWIMCROSS Exercise System from either side towards the bottom, you will find a plastic cap attached to wall.
Once your SWIMCROSS Exercise System has been filled with water, turn it on and test all of the circuit breakers.
IMPORTANT: If breaker immediately trips, verify that the wires are correctly connected. Breaker should be tested prior to each use. Here’s how:
1. Push the “TEST” button on each GFCI breaker, and observe it click OFF.
2. Wait 30 seconds, then push the breaker switch to the OFF (down) position (to ensure that it has completely disengaged), then push the breaker switch to the ON (up) position. If you don't wait 30 seconds, the SWIMCROSS Exercise System’s power indicator may continue to blink – try again.
If any of the GFCI breakers fails to operate in this manner, your SWIMCROSS Exercise System may have an electrical malfunction, and you may be at risk of electrical shock. Turn off all circuits and do not use the SWIMCROSS Exercise System until the problem has been corrected by an authorized service agent.
WARNING: Removing, or bypassing any GFCI breaker will result in an unsafe SWIMCROSS Exercise System and will void the SWIMCROSS Exercise System’s warranty.
feet away, in accordance with all
IMPORTANT: If you ever need to move or relocate your ENDLESS POOLS SWIMCROSS Exercise System, it is essential that you understand and apply these installation requirements. Your ENDLESS POOLS SWIMCROSS Exercise System has been carefully engineered to provide maximum safety against electric shock. Remember, connecting the SWIMCROSS Exercise System to an improperly wired circuit will negate many of its safety features.
NOTE: Long wiring runs may require larger-gauge wire than stated.
L2
N
L1
G
Electrical Requirements
Page 5
EQUIPMENT COMPARTMENT
The illustrations below are to be used as a reference only (your SWIMCROSS Exercise System may look different). The equipment compartment is located behind the hydromassage seats (back of the SWIMCROSS Exercise System).
CAUTIONS
8
2
6
1. Hydromassage Jets & filter pump
2. Swim Jets Pump
3. Control Box & Heater
4. Bonding terminal
5
3
4
2
7
1
5. UVC Ozone
6. Bluetooth Music (optional)
7. Subwoofer (optional)
8. Wi-Fi (optional)
USE COPPER CONDUCTORS ONLY.
USE SUPPLY WIRES SUITABLE FOR 75°C/167°F.
DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING.
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND-FAULT INTERRUPTER.
THESE SWIMCROSS EXERCISE SYSTEMS ARE INTENDED FOR USE WITH GFCI SUBPANEL PROVIDED.
INCORRECT WIRING WILL DAMAGE CIRCUIT BOARDS.
REFER TO THE WIRING INSTRUCTIONS INCLUDED WITH THE SUB-PANEL FOR DETAILED WIRING INSTRUCTIONS.
DOOR PANEL REMOVE & REPLACE
REMOVAL
1. Locate the vertical T-spacer in the center of the equipment compartment (back side of SWIMCROSS Exercise System).
2. Remove the 4 screws (using a 5/16" socket) holding the T-spacer then remove the T-spacer.
3. Slide panel towards center until panel is no longer behind corner.
4. While holding panel, first pull panel up then pull bottom away from SWIMCROSS Exercise System.
5. Lower panel to remove. Repeat for other side.
REPLACE
1. Raise panel making sure it goes behind the bar top then lower to rest on bottom frame
2. Slide panel behind corner.
3. Replace other side panel using steps 1 & 2.
4. Attach T-spacer back in place using 4 screws to complete the installation.
Page 6
Electrical Requirements
Loading...
+ 19 hidden pages