Watkins Manufacturing Corporation congratulates you on your decision to enjoy the finest SWIMCROSS
Exercise System available. Welcome to the growing family of SWIMCROSS Exercise System by
ENDLESS POOLS owners.
OWNER’S MANUAL
This Owner’s Manual will acquaint you with the operation and general maintenance of your new SWIMCROSS Exercise
System. We suggest that you take some time to carefully review all sections. Please keep this manual available for
reference.
If you have questions about any aspect of your SWIMCROSS Exercise System’s set-up, operation or maintenance, contact
your authorized ENDLESS POOLS dealership. They are trained professionals who are familiar with the product, as well
as new SWIMCROSS Exercise System ownership concerns. Their expertise will facilitate the enjoyment of your new
SWIMCROSS Exercise System.
The serial number/identification label is located within the equipment compartment of your SWIMCROSS Exercise System.
The serial number should also be documented on the delivery receipt from your dealer.
IMPORTANT: Watkins Manufacturing Corporation reserves the right to change specifications, or design, without notification
and without incurring any obligation.
DATE PURCHASED: ___________________________________
DATE INSTALLED: _____________________________________
COVER SERIAL NUMBER: ______________________________
In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and
gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property
to prevent unsupervised access to the SWIMCROSS Exercise System by children. As a general practice, your local Building Department will
inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your ENDLESS POOLS
dealer can provide information on which permits may be required.
TABLE OF CONTENTS
SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS .............................. 1
Danger: Diving May Result
in serious injury or death.
• Do not connect any auxiliary components (for example, cable,
INSTRUCTIONS)
• Do not self service the audio component by opening or removing
AVOIDING THE RISK TO CHILDREN
DANGER - RISK OF CHILD DROWNING
Extreme caution must be exercised to prevent unauthorized access
by children. To avoid accidents, ensure that children cannot use a
SWIMCROSS Exercise System unless they are supervised at all times.
WARNING
To reduce the risk of injury, do not permit children to use this
SWIMCROSS Exercise System unless they are closely supervised at all
times.
• To reduce the risk of injury, lower water temperatures are
recommended for young children. Children are especially sensitive to
hot water.
• Extreme caution must be exercised to prevent unauthorized access
by children. To avoid accidents, ensure that children cannot use the
SWIMCROSS Exercise System unless they are supervised at all
times.
DO:
• Make sure you always lock any child resistant locks after using the
SWIMCROSS Exercise System for your children’s safety.
• Test the water temperature with your hand before allowing children
to enter the SWIMCROSS Exercise System to be sure that it’s
comfortable.
• Remind children that wet surfaces can be very slippery. Make sure
that children are careful when entering or exiting the SWIMCROSS
Exercise System.
DON'T:
• Allow children to climb onto a SWIMCROSS Exercise System cover.
• Allow children to have unsupervised access to the SWIMCROSS
Exercise System.
AVOIDING THE RISK OF ELECTROCUTION
DANGER - RISK OF ELECTROCUTION
• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death,
or serious personal injury due to electrocution if direct burial-type cable
is not used, or if improper digging occurs.
• A ground terminal (pressure wire connector) is provided on the control
box inside the unit to permit connection of a minimum No. 6 AWG
(16 mm²) solid copper bonding conductor between this point and any
metal equipment, metal water pipe, metal enclosures of electrical
equipment, or conduit within five feet (1.5 m) of the unit as needed to
comply with local requirements.
• Do not attach an external antennae to a SWIMCROSS Exercise
• To reduce the risk of electrical shock, replace a damaged cord
• Your SWIMCROSS Exercise System is provided with a Ground
• Install at least 5 feet (1.5 m) from all metal surfaces. A SWIMCROSS
additional speakers, headphones, additional audio components) to the
audio system unless approved by Watkins Manufacturing Corporation
SWIMCROSS Exercise System door panel as this may expose
dangerous voltage or other risk of injury. Refer all servicing to qualified
service personnel.
System audio system unless installed by a licensed electrician in
accordance with Article 810 of the National Electric Code, ANSI/NFPA
70.
WARNING
immediately. Failure to do so may result in death or serious personal
injury due to electrocution.
Fault Circuit Interrupter (GFCI) for user and equipment protection. To
ensure proper operation of this important safety device, test according
to the following instructions:
• A ground terminal is provided inside the junction box. To reduce
the risk of electric shock, connect this terminal to the grounding
terminal of your electrical service or supply panel with a continuous
green, insulated copper wire. The wire must be equivalent in size
to the circuit conductors supplying the equipment. In addition, a
bonding terminal (pressure wire connector) is provided on the
outside of the control box/heater for bonding to local ground
points. To reduce the risk of electric shock, this connector should
be bonded with a No. 6 AWG (16 mm²) solid copper wire to
any metal ladders, water pipes, or other metal within 5 feet (1.5
m) of the SWIMCROSS Exercise System to comply with local
requirements. The means of disconnection must be readily
accessible, but must be installed at least 5 feet (1.5 m) from the
SWIMCROSS
• Your SWIMCROSS Exercise System is provided with a suitably
rated circuit breaker to open all ungrounded supply conductors.
• Your SWIMCROSS Exercise System uses ground fault circuit
interrupters in the electrical subpanel. Before each use of the
SWIMCROSS Exercise System and with the unit operating, push
the TEST button on each breaker. The switch should click over to
the “Trip” position. Wait 30 seconds and reset each GFCI breaker
by switching it completely off and then completely on. The switch
should then stay on. If either of the interrupters does not perform in
this manner, it is an indication of an electrical malfunction and the
possibility of an electric shock. Disconnect the power until the fault
has been identified and corrected.
Exercise System.
DANGER - RISK OF ELECTRICAL SHOCK
Exercise System may be installed within 5 feet of a metal surface if
each metal surface is permanently connected by a minimum No. 8
AWG (10 mm²) solid copper conductor attached to the wire ground
Safety Information
Page 1
connector on the heater terminal block that is provided for this
purpose.
• Install your SWIMCROSS Exercise System is such a way that
drainage is away from the electrical compartment and from all
electrical components.
• Do not permit any electrical appliances, such as a light, telephone,
radio, or television within 5 feet (1.5 m) of a SWIMCROSS Exercise
System. Failure to maintain a safe distance may result in death, or
serious personal injury due to electrocution, if the appliance should fall
into the SWIMCROSS Exercise System.
DO:
• Be sure your SWIMCROSS Exercise System is connected to the
power supply correctly - use a licensed electrical contractor.
• Disconnect the SWIMCROSS Exercise System from the power supply
before draining the SWIMCROSS Exercise System or servicing the
electrical components.
• Test the Ground Fault Circuit Interrupter(s) before each use.
• Replace audio components only with identical components (if
your SWIMCROSS Exercise System is equipped with an audio
component).
DON'T:
• Use the SWIMCROSS Exercise System with the equipment
compartment door removed.
• Place electrical appliances within 5 feet (1.5m) of the SWIMCROSS
Exercise System.
• Use an extension cord to connect the SWIMCROSS Exercise System
to its power source. The cord may not be properly grounded and the
connection is a shock hazard. An extension cord may cause a voltage
drop, which will cause overheating of the jet pump motor and motor
damage.
• Attempt to open the electrical control box. There are no user serviceable
parts inside.
INCREASED SIDE EFFECTS OF MEDICATION
• The use of drugs or alcohol may cause unconsciousness with the
possibility of drowning.
• Persons using medications should consult a physician before using a
SWIMCROSS Exercise System; some medication may cause a user
to become drowsy, while other medication may affect heart rate, blood
pressure, and circulation.
• Persons taking medications which induce drowsiness, such as
tranquilizers, antihistamines, or anticoagulants should not use the
SWIMCROSS Exercise System.
HEALTH PROBLEMS AFFECTED BY SWIMCROSS
EXERCISE SYSTEM USE
• Pregnant women should consult a physician before using
SWIMCROSS Exercise System.
• Persons suffering from obesity, or with a medical history of heart
disease, low or high blood pressure, circulatory system problems,
or diabetes should consult a physician before using SWIMCROSS
Exercise System.
UNCLEAN WATER
• Keep the water clean and sanitized with correct chemical care. The
recommended levels for your ENDLESS POOLS SWIMCROSS
Exercise System are:
Free Available Chlorine:
1.0-5.0 ppm
Water pH:
7.2-7.8
Total Alkalinity:
80-120 ppm
Calcium Hardness:
50-150 ppm
RISKS TO AVOID
DANGER - RISK OF INJURY
• To reduce the risk of injury to persons, DO NOT remove suction fittings
(filter standpipes) located in the filter compartment.
• The suction fittings in the SWIMCROSS Exercise System are sized
to match the specific water flow created by the pump. Never replace
a suction fitting with one rated less than the flow rate marked on the
original suction fitting.
• There is a danger of slipping and falling. Remember that wet
surfaces can be very slippery. Take care when entering or exiting the
SWIMCROSS Exercise System.
• Never operate SWIMCROSS Exercise System if the suction fittings
are broken or missing.
• People with infectious diseases should not use the SWIMCROSS
Exercise System.
• Keep any loose articles of clothing, long hair, or hanging jewelry away
from rotating jets or other moving components. Long hair should be
tied up or placed under a bathing cap.
• Safe water temperature for aquatic exercise is approximately
85°F (29.5°C).
• DO NOT use this SWIMCROSS Exercise System alone.
• Refer to Water Quality and Maintenance section for complete
instructions.
IMPORTANT: Turn on the jet pump for a least ten minutes after adding
ANY SWIMCROSS Exercise System water chemicals into the filter
compartment.
Clean the filter cartridges monthly to remove debris and mineral buildup
which may affect the performance of the hydromassage jets, limit
the flow, or trip the high limit thermostat, which will turn off the entire
SWIMCROSS Exercise System.
AVOIDING THE RISK OF HYPERTHERMIA
Prolonged immersion in hot water can result in HYPERTHERMIA, a
dangerous condition which occurs when the internal temperature of
the body reaches a level above normal 98.6°F (37°C). The symptoms
of hyperthermia include unawareness of impending hazard, failure to
perceive heat, failure to recognize the need to exit the SWIMCROSS
Exercise System, physical inability to exit the SWIMCROSS Exercise
System, fetal damage in pregnant women, and unconsciousness
resulting in a danger of drowning.
WARNING
The use of alcohol, drugs, or medication can greatly increase the risk of
fatal hyperthermia in SWIMCROSS Exercise Systems.
Page 2
Safety Information
TO REDUCE THE RISK OF INJURY
• The water in the SWIMCROSS Exercise System should never
exceed 104°F (40°C). Water temperatures between 79°F and 104°F
(26°C and 40°C) are considered safe for a healthy adult. The lower
water temperatures are recommended for extended use (exceeding
ten minutes) and for young children. Extended use can cause
hyperthermia.
• Pregnant or possibly pregnant women should limit SWIMCROSS
Exercise System water temperatures to 85°F (29.5°C) consult a
physician prior to using this product. Failure to do so may result in
permanent injury to your baby.
• Do not use SWIMCROSS Exercise System having water temperatures
over 100°F (36°C) immediately following strenuous exercise.
• Keep all breakables, especially glass, away from this SWIMCROSS
Exercise System.
• Never insert any objects into any openings.
• Keep all chemicals away from children and pets.
• DO NOT stack chemicals on top of one another.
• NEVER MIX CHEMICALS.
• Sanitizing chemicals must be stored separately from balancing chemicals.
AVOIDING THE RISK OF SKIN BURNS
DON'T:
• Leave the SWIMCROSS Exercise System exposed to the sun without
water or a cover in place. Exposure to direct sunlight can cause solar
distress of the shell material.
• Roll or slide the SWIMCROSS Exercise System on its side. This will
damage the siding.
• Lift or drag the vinyl cover by using the cover lock straps; always lift or
carry the cover by using the handles.
• Attempt to open the electrical control box. There are no user
serviceable parts inside. Opening of the control box by the
SWIMCROSS Exercise System owner will void the warranty. If you
have an operational problem, carefully go through the steps outlined in
the Troubleshooting section. If you are not able to resolve the problem,
contact your authorized ENDLESS POOLS dealer. Many problems
can easily be diagnosed over the telephone by an Authorized Service
Technician.
SWIMCROSS EXERCISE SYSTEM SHELL
Your SWIMCROSS Exercise System has an acrylic shell. Stains and
dirt generally will not adhere to your SWIMCROSS Exercise System’s
surface. A soft rag should easily remove most dirt. Most household
chemicals are harmful to your SWIMCROSS Exercise System’s shell
(see below for detailed information on cleaning agents). Always rinse
off any SWIMCROSS Exercise System shell cleaning agent with fresh
water.
• To reduce the risk of injury, before entering a SWIMCROSS Exercise
System the user should measure the water temperature with an
accurate thermometer.
• Test the water with your hand before entering the SWIMCROSS
Exercise System to be sure it’s comfortable.
SAFETY SIGN
Each ENDLESS POOLS SWIMCROSS Exercise System is shipped
with a SAFETY SIGN in the owner’s package. The sign, which is
required as a condition of Product Listing, should be permanently
installed where it is visible to the users of the SWIMCROSS Exercise
System. To obtain additional SAFETY SIGNS, contact your ENDLESS POOLS dealer. Safety labels that are affixed to the shell are intended to
be permanent and should not be removed.
IMPORTANT
SWIMCROSS EXERCISE
SYSTEM INSTRUCTIONS
The following contains important SWIMCROSS Exercise System
information, and we strongly encourage you to read and apply them.
IMPORTANT:
1. The following products are the ONLY approved cleaning agents for
your SWIMCROSS Exercise System shell: plain water, Brillianize®
or Soft Scrub®. The use of alcohol or any other household cleaner
other than those listed to clean the SWIMCROSS Exercise System
shell surface is NOT recommended. DO NOT use any cleaning
products containing abrasives or solvents since they may damage
the shell surface, specifically: Simple Green
NEVER USE HARSH CHEMICALS! Damage to the shell by use of
harsh chemicals is not covered under the warranty. Always rinse off
any SWIMCROSS Exercise System shell cleaning agent with fresh
water.
2. Iron and copper in the water can stain the SWIMCROSS Exercise
System shell if allowed to go unchecked. Ask your ENDLESS
POOLS dealer about a Stain and Scale Inhibitor to use if your
SWIMCROSS Exercise System has a high concentration of
dissolved minerals.
3. Keep all cleaners out of the reach of children and use care when
applying.
®
, Windex® or spa Mitt.
DO:
• Follow the SWIMCROSS Exercise System Care and Maintenance
recommendations stated in this manual.
• Use only approved accessories and recommended SWIMCROSS
Exercise System chemicals and cleaners.
SAVE THESE INSTRUCTIONS
Page 3Safety Information
SIterequIrementS
Your
SWIMCROSS
and level surface that can support 190 lbs per square foot.
If a new slab is poured, consult your local electrical codes regarding
grounding and bonding. Local code may require a bonding wire to be
attached to the reinforcing bar or wire mesh that is embedded in the
concrete. If new concrete is being poured, this is the ideal time to install
the conduit for the incoming electrical supply.
Even if a new pad has been poured, it is essential that the system site
is level and planar. There is a simple way to ensure that this is the
case. First, draw a chalk outline of the footprint of your
Exercise System. Place a six-foot level along and around the footprint
of the system. Verify that there are no gaps between the level and floor.
Next pour water inside of the chalk footprint. Verify that the water does
not puddle inside the footprint.
Should there a be a gap or should the water puddle inside the footprint,
call your ENDLESS POOLS dealer prior to continuing to discuss the
best way to resolve this situation.
INDOOR CONSIDERATIONS
1. Local electrical and plumbing codes.
2. Ventilation fans and/or dehumidifiers should be provided to handle
the humidity developed by your
Walls, ceiling and wood trim should be water resistant, also.
3. Chemicals will vaporize from the water and may cause an odor
and possibly corrosion to certain home hardware. Never store
chemicals inside the
4. During the normal use of the
water will escape the vessel. Never place on or over any materials,
which may be damaged by this water or the chemicals within the
water. Keep damageable materials far enough away to avoid water
damage, even if the
all its water.
5. Consider and prepare for the unlikely event of rapid drainage. If
placement of the
you may wish to provide floor drains to accommodate draining, etc.
Always leave room all around the
for easy access in case repairs are necessary.
6. Consider and prepare for the unlikely event of removal.
7. Do not set
without a waterproof barrier protection underneath.
8. The
9. The
10. Be sure that the location you choose is stable. It must be able
11. Do not use the
SWIMCROSS
power source capable of supplying 230 volts AC power. It must
be wired directly into a grounded circuit with a ground fault circuit
interrupter (GFCI). No other appliances should be on the same
circuit.
SWIMCROSS
of water.
to support the weight of the
when it is filled with water, plus the weight of the occupants. The
SWIMCROSS
(8,265 kg) when it is filled with water.
living area due to the risk of water damage.
Exercise System must be installed on a smooth
SWIMCROSS
SWIMCROSS
SWIMCROSS
Exercise Systemcabinet.
SWIMCROSS
SWIMCROSS
SWIMCROSS
Exercise System should lose
Exercise System is permanent,
SWIMCROSS
SWIMCROSS
Exercise System on finished floor
Exercise System should have access to a
Exercise System should be close to a source
SWIMCROSS
Exercise System may weigh up to 18,185 lbs
SWIMCROSS
Exercise System above a finished
Exercise System.
Exercise System,
Exercise System
Exercise System
12. The
SWIMCROSS
Exercise System is not designed for in-floor
installation. However, it is compatible with a deck system that is
built flush with the bar top, provided you leave access for service.
13. Be sure to note any other considerations, such as aesthetics or
privacy concerns that may affect the safety or enjoyment of using
the
SWIMCROSS
Exercise System.
OUTDOOR CONSIDERATIONS
1. Local electrical and plumbing codes.
2. Consider local codes pertaining to fencing, enclosures, walls,
electrical and plumbing. You will need to ensure that your
SWIMCROSS
from power lines, both above ground and underground. Your
SWIMCROSS
3. View from house for aesthetics and supervisory needs.
4. Distance from house for wintertime soaking.
5. Nighttime lighting.
6. Consider sunlight exposure, views, access, property lines, lighting,
wind direction, shielding, septic tanks, plants, and trees when
determining your location. Chemicals in the
Exercise System water may splash damaging nearby plant life.
7. If your
second story, be positive support is adequate. Call your builder and
a structural engineer.
8. Area for placement of support equipment where adequate space
will be needed to gain access to components for maintenance and
general servicing.
9. Be sure to note any other considerations, such as aesthetics or
privacy concerns that may affect the safety or enjoyment of using
the
SWIMCROSS
10. Provide adequate drainage away from the equipment and
adequate elevation to allow draining by siphon, if should be
required.
11. Location of electrical supply. 230-volt systems require hard wire
installed from the main electrical source, to the sub panel, then to
the
SWIMCROSS
must be ground fault circuit protected (NOT SUPPLIED) . All
electrical wiring must comply with the national electric code.
12. Locations at least 5 ft (1.52 m) from all metal surfaces. A
SWIMCROSS
of metals surfaces providing each metal surface is permanently
connected by a no. 8 awg (8.4 mm2) copper conductor attached to
the bonding wire connector on the heater provided for this purpose.
All installations must comply with article 680 of the U.S. national
electric code and ANSI/NFPA 70-1984.
13. Place the
that will not shift.
Exercise System is an adequate distance
Exercise System will also need to be child proofed.
SWIMCROSS
SWIMCROSS
SWIMCROSS
Exercise System is to be located on a
Exercise System.
Exercise System terminal block. All equipment
Exercise System may be installed within 5 feet
Exercise System on a firm, level surface
Page 4
Site Requirements
electrIcal requIrementS
IMPORTANT
turning on the power.
Your ENDLESS POOLS SWIMCROSS Exercise System has been
carefully designed to give you maximum safety against electrical shock.
Connecting the SWIMCROSS Exercise System to an improperly wired
circuit will negate many of the SWIMCROSS Exercise System’s safety
features. Improper wiring may also cause electrocution, risk of fire, and
other risks of injuries. Please read and follow the electrical installation
requirements and instructions completely!
230 VOLT PERMANENTLY
CONNECTED
ENDLESS POOLS SWIMCROSS Exercise Systems must be wired
in accordance with all applicable local electrical codes. All electrical
work should be done by an experienced, licensed electrician. We
recommend the use of appropriate electrical conduit, fittings, and wire
for all circuits.
The diagram below illustrates how to wire the SWIMCROSS
Exercise System model:
• An electrical subpanel containing a 60 Amp breaker is included with
your SWIMCROSS Exercise System. We recommend that this
subpanel be used to supply power to the SWIMCROSS Exercise
System.
• The subpanel requires a 60 amp, single phase, 230 volt, four
: Fill the SWIMCROSS Exercise System with water before
wire service (two line, one neutral, one ground). The grounding
conductor must not be less than #6 AWG. Refer to local codes and
to NEC 250-122 (table).
• Mount the subpanel in the vicinity of the SWIMCROSS Exercise
System, but not closer than five
local codes. (N.E.C. 680-38 to 41-A-3)
• Open SWIMCROSS Exercise System by removing the 4 screws
holding the vertical T-spacer located in the center of the equipment
compartment (back side of SWIMCROSS Exercise System). Slide
panel towards center and remove, repeat for other panel.
• Insert power wires into SWIMCROSS Exercise System from either
side towards the bottom, you will find a plastic cap attached to wall.
• Once your SWIMCROSS Exercise System has been filled with
water, turn it on and test all of the circuit breakers.
IMPORTANT: If breaker immediately trips, verify that the wires are
correctly connected. Breaker should be tested prior to each use. Here’s
how:
1. Push the “TEST” button on each GFCI breaker, and observe it
click OFF.
2. Wait 30 seconds, then push the breaker switch to the OFF (down)
position (to ensure that it has completely disengaged), then push
the breaker switch to the ON (up) position. If you don't wait 30
seconds, the SWIMCROSS Exercise System’s power indicator
may continue to blink – try again.
If any of the GFCI breakers fails to operate in this manner, your
SWIMCROSS Exercise System may have an electrical malfunction,
and you may be at risk of electrical shock. Turn off all circuits and do
not use the SWIMCROSS Exercise System until the problem has been
corrected by an authorized service agent.
WARNING: Removing, or bypassing any GFCI breaker will result
in an unsafe SWIMCROSS Exercise System and will void the
SWIMCROSS Exercise System’s warranty.
feet away, in accordance with all
IMPORTANT: If you ever need to move or relocate your ENDLESS POOLS SWIMCROSS Exercise System, it is essential that you understand and
apply these installation requirements. Your ENDLESS POOLS SWIMCROSS Exercise System has been carefully engineered to provide maximum
safety against electric shock. Remember, connecting the SWIMCROSS Exercise System to an improperly wired circuit will negate many of its safety
features.
NOTE: Long wiring runs may require larger-gauge wire than stated.
L2
N
L1
G
Electrical Requirements
Page 5
EQUIPMENT COMPARTMENT
The illustrations below are to be used as a reference only (your SWIMCROSS Exercise System may look different). The equipment compartment is located
behind the hydromassage seats (back of the SWIMCROSS Exercise System).
CAUTIONS
8
2
6
1. Hydromassage Jets & filter pump
2. Swim Jets Pump
3. Control Box & Heater
4. Bonding terminal
5
3
4
2
7
1
5. UVC Ozone
6. Bluetooth Music (optional)
7. Subwoofer (optional)
8. Wi-Fi (optional)
USE COPPER CONDUCTORS ONLY.
USE SUPPLY WIRES SUITABLE FOR 75°C/167°F.
DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING.
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A
GROUND-FAULT INTERRUPTER.
THESE SWIMCROSS EXERCISE SYSTEMS ARE INTENDED FOR
USE WITH GFCI SUBPANEL PROVIDED.
INCORRECT WIRING WILL DAMAGE CIRCUIT BOARDS.
REFER TO THE WIRING INSTRUCTIONS INCLUDED WITH THE
SUB-PANEL FOR DETAILED WIRING INSTRUCTIONS.
DOOR PANEL REMOVE & REPLACE
REMOVAL
1. Locate the vertical T-spacer in the center of the equipment compartment (back side of SWIMCROSS Exercise System).
2. Remove the 4 screws (using a 5/16" socket) holding the T-spacer then remove the T-spacer.
3. Slide panel towards center until panel is no longer behind corner.
4. While holding panel, first pull panel up then pull bottom away from SWIMCROSS
Exercise System.
5. Lower panel to remove. Repeat for other side.
REPLACE
1. Raise panel making sure it goes behind the bar top then lower to rest on bottom frame
2. Slide panel behind corner.
3. Replace other side panel using steps 1 & 2.
4. Attach T-spacer back in place using 4 screws to complete the installation.
Page 6
Electrical Requirements
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.