ENDEAVOUR ET3560 Owner's Manual

1. Keep bod
y face clean, preve
nt liquid material from getting into slider
to destroy electronics.
2. Face should be cleaned with a clean, dry, lint-free cloth. Lubricate body with a few drops of clock oil. Acetone & alcohol must not be used.
3. Keep battery compartment clean and free of corrosion.
Every second 5 digits Battery voltage is under 1.45V. Remove jump simultaneously cover and replace battery.
Display cannot count Faulty circuit. Remove battery, after 30
sec. put battery back into compartment.
Display shows 000.00 Function buttons and sliders signal end or IN 00.000 may have shorted out. Remove the
cover, put the button springs in place with rubber covers. Contact must be unobstructed.
Function buttons not active Springs or rubber covers may be out of
shape due to excessive pressing. See solution above for tips.
Reading error for full Sensor may have dirt or deposits in it length is ≥ 0.1mm Remove cover and slider assembly.
Blow off sensor face with clean pressurized air (≥5kg/cm squared), clean with a dry, lint-free cloth.
No display on LCD screen 1.) Poor battery contact. Check battery
compartment, clean if necessary.
2.) Battery voltage is under 1.3V. Replace with correct battery.
Digital Caliper
ET 35 60
OWNER'S MANUAL
CARE & MAINTENANCE
TROUBLESHOOTING
In accordance with the
European Directive
ROHS 2002/95/CE
D4 06 07 60503 001
FOR YOUR SAFETY, and CARE OF THIS TOOL
Please read these instructions carefully and retain them for future use.
03.04.0487ECC
Your digital caliper was constructed with quality materials and workmanship and will give you many years of trouble free use when cared for as described in the "Care & Maintenance" section.
Repeatability:
0.01 mm or 0.0005"
Maximum measuring speed:
1.5m/sec or 60"/sec.
Measuring system:
Non-contaction linear CAP measuring system
Display:
LCD display, minus sign "-", character in 6.35mm/0.25" height
for 5 digits, small digit "5" and "IN" sign for inch measuring unit.
Battery:
SR44/LR44.
Low battery warning by flashing display.
Operating temperature:
0 ℃ ~ +40
Storage temperature:
-20 ℃ ~ +70
Influence of humidity:
Not important within 0 to 80% of relative humidity.
Measurement of external dimensions Measurement of internal dimensions
Measurement of depth Measurement of steps
* ð——…⁄ …5ßð˙ fCfi …˙ g` ⁄ …fi …5ßCfi …ß=fl8CI ˙ ƒƒfðe˙ ßðfl5Cfl—C› …⁄ flCg…ßßð5–J
Measuring Range: Resolution:
0 - 150mm / 0 - 6" 0.01mm / 0.0005" 0 - 200mm / 0 - 8" 0.01mm / 0.0005"
0 - 300mm / 0 - 12" 0.01mm / 0.0005"
Measuring Range: Accuracy:
0 - 100mm / 0 - 4" 0.02mm / 0.001"
200- 300mm / 8 - 12" 0.03mm / 0.0015"
SPECIFICATIONS AND FUNCTIONS
ZERO setting (zero
setting at an
y
position within the measuring range)
Metric/Inch change over (true conversion)
ON/OFF switch
Battery compartment cover
CALIPER FEATURES
CALIPER APPLICATIONS