ENDA PTM232 User Manual

ENDA PTM232 DIGITAL TIMER
Keypad:
TECHNICAL SPECIFICATIONS
CONNECTION DIAGRAM
Dimensions Display Time ranges Accuracy Start Reset Gate Output function Control output Supply voltage
Power consumption Ambient temperature Keypad Data retention Wiring Weight
Main Properties :
* 6 different time ranges 0-9.9 S 0-99 S 0-9.9 m 0-99 m 0-9.9 h 0-99 h
* Easy to operate. * Relay output can be adjusted for set value. * Start by start input. * Down counting direction for time.
* Reset input.
* Gate input.
Digital Display:
Displayed time value in the run mode, adjusted time in programming mode.
Time unit
Displayed time unit.
: W44xH73xD90mm : 2 digits, 14.2mm, 7 segment red LED : It can be adjustable between 0-9.9 seconds and 0-99 hours. : ±%1 : By start input : By reset input : By gate input : 6 different timing functions can be selectable. : 2 relays. 230V AC, 2A (for resistive load), NO+NC. : 230V AC +10% -20%, 50/60Hz or 24V AC ±10%, 50/60Hz
: 2VA : 0-50 C : Micro switch : EEPROM (min. 10 years) : 11 pins round socket : 215 g.
º
url: www.enda.com.tr
76mm
44mm
73mm
90mm
70mm
or optional 9-30V DC / 7-24V AC ±10% SMPS module.
When held down for 0.6 second the change rate accelerates. When first pressed and held for 5 seconds, time unit and output type adjustment mode is entered.
When first pressed, the time adjustment mode is entered. Used for decreasing the numerical value in the time adjustment mode.
When held down for 0.6 second
the change rate accelerates.
When first pressed, the time adjustment mode is entered. Used for increasing the numerical value in the time adjustment mode.
ENDA
PTM232
DIGITAL TIMER
OUT1
h
m
s
OUT2
SET
DIGITAL TIMER
SET
ENDA
INDUSTRIAL ELECTRONICS
PTM232 DIGITAL TIMER
230V AC +10% -20%
50/60Hz 7VA
1
2
3
4
5
6
7
8
9
10
11
SUPPLY
RESET
START
GATE
OUT1 OUT2
CONTACT 5A 250VAC
SN: XXXXXXXXXX
1/ 2 PTM232-E-04
Displayed timer value
PTM232 PROGRAMMING DIAGRAM
OUTPUT TYPES
USING GATE INPUT
Time adjustment mode
Time unit adjustment mode
Output type adjustment mode
programming mode is entered and display flashes.If key is pressed and held for 5 seconds, the
If key is pressed, the output type adjustment mode is entered and
o2 message flashes. By using key output type can be adjusted
between 0 and 5 Input and output diagrams according to output types
can be seen next page.
If no key is pressed within 5 seconds, the adjusted value is stored automatically and the run mode is entered.
START
START
START
START
START
START
POWER
POWER
POWER
POWER
POWER
POWER
MODE 2 ( DELAY WITH START ON/OFF (MODE C) )
MODE ( FLASH WITH START (MODE B) )
MODE 0 ( DELAY WITH START ON (MODE A) )
MODE 4 ( SUDDEN OUTPUT AND DELAY WITH START ON )
MODE 3 ( DELAY WITH START OFF (MODE D) )
T
TTT
T
T1
T
T
T
T TTT
T
T2
T
T
T-a
T-a
T-a
T-a T-a
T-a
RESET
RESET
RESET
RESET
GATE
RESET
RESET
OUT 2 (NO) 11- 9
OUT 2 (NO) 11- 9
OUT 2 (NO) 11- 9
OUT 2 (NO) 11- 9
OUT 1 (NO) 1- 3
OUT 2 (NO) 11- 9
OUT 1 (NO) 1- 3
OUT 1 (NO) 1- 3
OUT 1 (NO) 1- 3
OUT 1 (NO) 1- 3
OUT 2 (NO) 11- 9
OUT 1 (NO) 1- 3
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
DISPLAY
%100
%100
%100
%100
%100
%100
Run Mode
Programming Mode
Note: 1. Above diagram shows gate input if
the mode 0 is selected.
2. Sum of T1 and T2 is adjustment (set) time.
If t.t message flashes, means, the time range adjustment mode is entered.
By using key, 6 different time ranges can be selected.
Selected time range can be realized by time range indicators and
decimal point.
OUT1
h
m
s
OUT2
When pressed any key, the time adjustment mode is entered.Display flashes
to indicate the time adjustment mode is entered. By using and
keys, the value can be adjusted. When held down for a few seconds, the
change rate accelerates. If no key is pressed within 5 seconds, the adjusted
value is stored automatically and the run mode is entered.
START
POWER
MODE 5 ( DELAY WITH START ON )
T T
T+a
T-a
RESET
OUT 2 (NO) 11- 9
OUT 1 (NO) 1- 3
DISPLAY
%100
T
SET
SET
SET
SET
2/2 PTM232-E-04