Enda MU-PT100-U010 TECHNICAL DATA

MU-PT100-U010 Analog PT100 Temperature-Transmitter
english
TECHNICAL DATA Input: Sensor type: Measuring range: Output: Supply voltage: Transfer characteristic: Direct current: Wire resistance: Supply voltage min.: Linearity error: Accuracy: Operating temperature range: Output signal on sensor failure: Mounting: Connection terminals: Dimensions: Material: Housing: Weight:
2-/3-wire
PT100
3
2
1
PT100, 2 or 3-wire connection PT100 (DIN EN 60751)
the label:
for example. 0..200°C or -50...+100°C
0...10V 12 ... 35VDC, reverse polarity protected temperature linear max. 25mA + Load current min. 1k
Ω min. 8V max. 0,05% max. 0,1%
0... 50°C 0V or > 10,5V 35 mm-rail mounting Screw terminals with wire protection, 0,2..2,5 mm² 75 x 15 x 53 mm (h x w x d) Polycarbonate EMG15 ca. 40g
The output current follows linear at the input Temperature signal. The signal output measured between the terminals 4 and 5. Between the sensor and the supply and output current don`t be galvanic isolated connection.
5
6
4
Input connection diagram
PT100
up to date: 06052019, modification reserved and can be change any time previous notice !
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
3 2
1
Tel.: +49 (0)7451 / 625 617 Fax: +49 (0)7451 / 625 0650
In the two-wire circuit, the resistance of the cable in the measuring result. Therefore, this circuit can be selected only for short lines or low accuracy requirements. Between the terminals 1 and 2 at the transmitter a bridge must be clamped.
E-mail : info@suran-elektronik.de Internet : www.suran-elektronik.de