3/3
Used for displaying and configuring the selected parameter value.
Programming
Key
Used for increasing the setpoint value and changing parameters.
When held down for a few seconds, configured numeric value increases faster..
When held down for a few seconds, configured numeric value increases faster.
Used for decreasing the setpoint value and changing parameters.
Increment
Key
Decrement
Key
EI1410 PROGRAMMING DIAGRAM
If without pressing any button for 20 seconds or powered down and powered up the device, then it returns to operation mode.
If both & keys are pressed and held for 3 seconds, programming mode is entered or run mode is returned.
Alarm
upper limit
value
Process value
RUN MODE
PROGRAMMING MODE
Alarm lower limit value. If the process value falls below A.lol value, display flashes.
By using and keys, while holding key, the lower limit can be adjusted to desired value
between -60.0°C and A.upl.
Alarm upper limit value. If the process value exceeds A.upl value, display flashes.
By using and keys, while holding key, the upper limit can be adjusted to desired value
between A. and 150.0°C.lol
Alarm
lower limit
value
Alarm hysteresis value.
By using and keys, while holding key, hysteresis value can be adjusted to desired value
between 0.0°C and 15.0°C. Maximum value of this parameter must be ( - ) / .A.upl A.Lol 2
If this key is pressed,
upper limit value
appears.
If this key is pressed,
lower limit value
appears.
Selecting decimal place.Display can be selectable decimal or integer.
By using and keys, while holding key, display can be selected decimal or integer.
When is selected, decimal case is entered. If is selected, integer case is entered.
All of other parameters are adjusted according to selection.
Yes no
If this key is pressed,
temperature unit
appears.
Temperature unit.
By using and keys, while holding key, temperature unit can be selected °C or °F.
If this key is pressed,
display alternatives
appears.
Alarm
hysteresis
value
If this key is pressed,
hysteresis value
appears.
If this key is pressed,
offset value
appears.
Offset value.
By using and keys, while holding key, offset can be adjusted to desired value
between -20.0°C ile 20.0°C.
Means, indicator probe is short circuit.
Means, indicator probe is broken.
ERROR MESSAGES
Means, process value is higher than the scale.
Means, process value is lower than the scale.
EI 1410
ENDA
SET
SET
°F
°C
SET
Temperature
unit
Selecting
decimal place
Offset
value
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
In run mode, key is held down, the highest measured temperature is displayed.
Pressing this key while holding down the or the first power up of the device,
measured at the highest temperature value set to the value of the current temperature.
In run mode, key is held down, the highest measured temperature is displayed.
Pressing this key while holding down the or the first power up of the device,
measured at the lowest temperature value set to the value of the current temperature.
if the measurement temperature is above A.uPL value, the indicator flashes a warning.
EI1410-E-10-R-201307