ENDA EDP 141 User Manual

Page 1
Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages.
ENDA EDP 141 DIGITAL POTENTIOMETER
Thank you for choosing ENDA EDP 141 potentiometer.
* 34x77mm sized. *
4 digits display.
Easy to use by front panel keypad.
Display scale can be adjusted between -1999 and 8000.
* Decimal point can be adjusted between 1. and 3. digits.
* 0-10V output with adjustable minimum and maximum values. * ‘Soft on’ and ‘soft off’ properties can be selected.
* Parameter access protection on 3 levels.
* Having CE mark according to European Norms.
DIGITAL POTENTIOMETER
ENDA
SET
EDP141
Supply Voltage
230V AC +%10 -%20
24V AC %10
9-30V DC SMPS module
Order Code
EDP141
EDP141-24AC
EDP141-24DC
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature Max. relative humidity
Rated pollution degree
Height
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply
Power consumption Wiring Date retention EMC Safety requirements
0 ... +50 °C/-25 ... +70°C (with no icing) 80% up to 31 decreasing linearly 50% at 40 . °C °C According to EN 60529 Front panel : IP60
Rear panel : IP20
Max. 2000m
230V AC +10% -20%, 50/60Hz or 24V AC ±10% 50/60Hz or 9-30V DC SMPS module
Max. 7VA
2.5mm² screw-terminal connections
EEPROM (Min. 10 years) EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard) EN 61010-1: 2001 (pollution degree 2, overvoltage category II, measurement category I)
OUTPUT
0-10V output
M igitally adjustedaximum 10mA, d potentiometer output. Resolution : 1/10000 V Fluctuation : Maximum 30mV Rise time from 0 to 10V is maximum 300ms
HOUSING
Housing type
Dimensions
Weight
Enclosure material
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ. Yukarý Dudullu 34775 - ÜMRANÝYE/ÝSTANBUL-TÜRKÝYE Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url : www.enda.com.tr
Barbaros Cad. Kutup Sok. No:20
Suitable for flush-panel mounting according to DIN 43 700. W77xH34xD70mm
Approx. 350g (after packing) Self extinguishing plastics
1/3
EDP141-E-05
Page 2
TERMS
DIGITAL POTENTIOMETER
ENDA
( 1 ) Digital display
Character height
( 2 ),( 3 ),( 4 ) Keypad
DIMENSIONS
34mm
1) Adjusted potentiometer value is seen in run mode Parameter name, value or its unit in programming mode.
SET
EDP141
EI141
2) Increment key during run mode. Increment or parameter selection key during programming mode.
3) Decrement key during run mode. Decrement or parameter selection key during programming mode.
4) Used for selecting run or programming modes and for adjusting parameters.
4 digits 7 segment yellow LED display
9.1mm
Micro switch
DIGITAL POTENTIOMETER
ENDA
85mm
SET
EI141
EDP141
For removing mounting clamps:
- Push up the flush-mounting clamp in direction 1 as shown in the figure above.
- Then, pull out the clamp in
direction 2.
Flush mounting
11 12
10
0-10V DC OUPUT
7 8 9
GND
SN: XXXXXXXXX
1 2 3 4 5 6
50/60Hz 3VA
230V AC +10% -20%
EDP141 DIGITAL POTENTIOMETER
ENDA INDUSTRIAL ELECTRONICS
1
clamp
29mm
Flush mounting
Panel cut-out
71mm
clamp
70mm
2
Panel
Note
1) Panel thickness should be maximum 7mm
2) If there is no 60mm free space at back side of the device, it would be difficult to remove it from the panel.
8mm
Rubber
CONNECTION DIAGRAM
ENDA EDP 141 is intended for installation in control panels. Make sure that the device is used only for intended purpose. grounded on the instrument side. must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or components. according to the relevant locally applicable regulations.
ENDA INDUSTRIAL ELECTRONICS
EDP141 DIGITAL POTENTIOMETER
SN: XXXXXXXXX
230V AC +10% -20%
50/60Hz 7VA
1 2 3 4 5 6
NOTE :
SUPPLY :
184-253V AC 50/60Hz 3VA
1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
Note:
2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator.
1
2
7 8 9
Line
Neutral
GND
10
11 12
F 100 mA 250V AC
Fuse should be connected
0-10V DC OUPUT
Fuse
During an installation, all of the cables that are connected to the device must be free of energy. The device
The installation and electrical connections must be carried on by a qualified staff and must be
ENDA INDUSTRIAL ELECTRONICS
EDP141-24DC DIGITAL POTENTIOMETER
SN: XXXXXXXXX
±
24V DC 10%
7VA
-
Anahtar
Cable size: 1,5mm²
+
1 2 3 4 5 6
230V AC Besleme
7 8 9
0-10V DC OUPUT
GND
10
11 12
Holding screw
0.4-0.5Nm
Equipment is protected throughout by DOUBLE INSULATION.
2/3
The shielding must be
ENDA INDUSTRIAL ELECTRONICS
EI141-24AC DIGITAL POTENTIOMETER
SN: XXXXXXXXX
24V AC +10% -20%
50/60Hz 7VA
1 2 3 4 5 6
7 8 9
10
11 12
EDP141-E-05
0-10V DC OUPUT
GND
Page 3
Run mode
S
E
1000
1000
Preset value
First press key. Then, by using keys, preset value can be
T
1000
SE
T
1001
1002
adjusted. If no key is pressed for 3 seconds Run mode is returned.
S
ET
If key is pressed and held for 5 programming mode is entered
secondsIf key is pressed and held for 5
seconds
Programming mode
U.oPt.
d.Pnt. = Decimal point.
D.Pnt.
l.sCl.
H.sCl.
Lo.Lý.
Hý.Lý.
Parameter adjustment method
NOTE 1
For adjusting a selected parameter first press and hold key. Then, by using keys, adjustment can be made.
If increment key is pressed and held 0.6 seconds, the value of the selected parameter changes rapidly. If waited enough, the value increases
100 at each step. After 1 second following the release of the key, initial condition is returned. The same procedure is valid for the decrement key.
Decimal point can be adjusted between 1. and 3. digits. See NOTE 1 for programming.
L.SCL. = Lower value of the scale.
It can be adjusted between -1999 and (H.SCL. -10) Output becomes 0V at the adjusted value.
H.SCL. = Upper value of the scale
It can be adjusted between (L.SCL. +10) and 8000.Output becomes 10V at the adjusted value. See NOTE 1 for programming.
Lo.Li. = Lower limit for preset
value.It can be adjusted between
and Hi.Li.l.SCL.
See NOTE 1 for programming.
Hi.Li. = Upper
value.It can be adjusted between Lo.li. and See NOTE 1 for programming.
limit for preset
H.SCl.
See NOTE 1 for programming.
S
ET
D.oPt.
P.on.C.
o.E.TY.
o.D.TY.
R.tý.
D.tý.
P.ý.d.t.
P.on.C. = Control parameter when first energized.
ofF= When first energized, output is the voltage that lower limit value is indicated. Attention: If this parameter is selected, the set value that was adjusted before is seen when set button is pressed at first. In addition,if increasing or decreasing that value is wanted the set value is equalized to lower limit value and then adjustment can be done. On= When first energized, output is the voltage that the set value is indicated. S.Str.= When first energized, output is increased slowly from the voltage that lower limit value is indicated to the voltage that set value is indicated during r.ti. See NOTE 1 for programming.
O.e.ty. = Adjusted type of the output to
with button.
dSAb. = Output cannot be adjusted to preset value with
button.
Enb. = Output can be adjusted to preset value with
button.
S.on. = Output is increased to voltage that set value is
displayed with button during r.ti. . See NOTE 1 for programming.
O.d.ty. = Adjusted t
with button.
dSAb. = Output cannot be adjusted to lower limit value with
button.
Enb. = Output can be adjuested to lower limit value with
button.
S.oFF. = Output is increased to voltage that lower limit
value is displayed with button during d.ti. . See NOTE 1 for programming.
R.ti. = increasing time for output.
It is adjusted between 1 and 250 seconds. Output is incerased slowly to the set value during adjusted time. See NOTE 1 for programming.
D.ti. = decreasing time for output.
It is adjusted between 1 and 250 seconds. Output is decreased slowly to the lower limit value during adjusted time. See NOTE 1 for programming.
P.i/d/t/ = speed of preset value. increasing and decreasing
It is adjusted between 1 and 3. P.i.d.t. = 1, set value changes one by one. P.i.d.t. = 2, set value changes 10 at each step. P.i.d.t. = 3, set value changes 100 at each step. See NOTE 1 for programming.
ype of the output to lower limit value
1001
preset value
If no key is pressed for 3 seconds
d.Cal.
S.Cod.
10/CA/
If o.E.t.Y and o.d.t.Y parameters is adjusted to any value except dSAb parameter, output can be controlled with and buttons.
Entering from programming mode to run mode:
If no key is pressed within 20 seconds during programming mode data is stored automatically and the run mode is entered. Alternatively the same function occurs by pressing key and holding for 5 seconds
SE
T
SeCU.
s.Cod. = Access code for safety menu.
This parameter should be 222. See NOTE 1 for programming.
10.CA. = calibration for 0-10V output.
The device should be calibrated until
10.000V is obtained at the output. Calibration procedure is as explained below.
S
E
T
When key is pressed, previous calibration
value is seen. While holding key, calibration value should be adjusted until 10.000V is seen
S
E
T
by using keys
at the output .
If key is released, calibration is exited. In the mean time, the new calibration value is saved in an EEPROM.
P.on.C.
OnOn
PowerPower
PRESETPRESET
OutOut
Lo.lý.
0V0V
o.E.ty.
o.d.ty.
PRESETPRESET
OutOut
off
Dsab.
Dsab.
S
E
T
Lo.lý.
Control can’t be done
Control can’t be done
with buttons.
with buttons.
S.Cod.
U.o.sc.
D.o.sc.
D.Ca.s.
on
Enb.
Enb.
by pressing
by pressing
the button
the button
s.Cod. = Access code for safety menu.
This parameter should be 333. See NOTE 1 for programming.
Uo.Sc. = U.oPt. menu protection level
parameter.
nonE = No menu is seen.
P. no = Menu is seen but can not be programmed. P.yES. = Menu is seen and programming is possible.
See NOTE 1 for programming.
d.o.Sc. = d.oPt. Menu protection level
parameter.
nonE = No menu is seen.
P. no = Menu is seen but can not be programmed. P.yES. = Menu is seen and programming is possible.
See NOTE 1 for programming.
d.Ca.S. = d.CAL. menu protection level
parameter.
nonE = No menu is seen.
P. no = Menu is seen but can not be programmed. P.yES. = Menu is seen and programming is possible.
See NOTE 1 for programming.
S.str.
R.ti.
S.on. S.off.
R.ti.
by pressing
by pressing
the button
the button
by pressing
by pressing
the button
the button
by pressing
by pressing
the button
the button
D.ti.
3/3
EDP141-E-05