Read this document carefully before using this device. The guarantee will be expired by
damaging of the device if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
ENDA EC442 UP/DOWN COUNTER
Thank you for choosing ENDA EC442 COUNTER.
* 48x48mm sized.
* 2x4 digits display.
* Easy to use by front panel keypad.
* Counting up and down with a 2 channel inputs having a 90° phase shift.
* Input frequency can be selectable.
* Prescaler factor can be adjusted between 0.001 and 9.999.
* Decimal point can be adjusted between 1. and 3. digits.
* Sensor type can be selected as PNP, NPN or Encoder.
* Single set-point control is made by a single relay output.
* Output can be energized continuously or just for a time interval of 0.1
to 999.9 seconds.
* Selectable functional reset input.
* Input offset feature.
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.
* Having CE mark according to European Norms.
EC 442
OUT
SET
ENDA
english
PRESET
PRESET UP/DOWN COUNTER
RESET
PV
SV
Order Code : EC442-
1
1 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature
Max. relative humidity
Rated pollution degree
Height
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply
Power consumption
Wiring
Date retention
EMC
Safety requirements
INPUTS
Count inpus (CP1, CP2)
Frequency (Hz)
Minimum On and Off times
for pulses
Reset input
0 ... +50°C/-25 ... +70°C (with no icing)
80% up to 31 decreasing linearly 50% at 40 . °C °C
According to EN 60529 Front panel : IP65
Rare panel : IP20
Max. 2000m
230VAC +10%/-20%, 50/60Hz, 24VAC±10%,50/60Hz or 24Vac/dc (9-30Vdc or 7-24Vac)
Max. 5VA
2.5mm² screw-terminal connections
EEPROM (Min. 10 years)
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)
EN 61010-1: 2001 (pollution degree 2, overvoltage category II)
2 channels (max. 9999Hz, 5V to 30V pulse)
25, 500, 1000, 2000, 5000, 7500Hz, 9999Hz (selectable by programming)
=25Hz 20ms for f
f=500Hz 1ms for
f=1kHz500ms for
f=2kHz250ms for
f=5kHz 100ms for
f=7,5kHz67ms for
50 =10kHz ms for f
PNP: Positive reset (5V to 30V pulse with adjustable pulse time between 2ms and 50ms)
NPN: GND terminal is connected to the RESET IN terminal.
OUTPUTS
Control output (OUT)
Auxiliary power supply
Life expectancy for relay
Note : Relay and S.S.OUT outputs are in synchronization . When OUT relay is energized S.S. OUT transistor goes into saturation.
Relay : 250V AC, 2A (for resistive load), NO+NC
Open collector output (S.S. OUT): Max. 30V DC, 100mA
12V DC, max. 50mA (without regulation)
Mechanical 30.000.000 operation; Electrical 300.000 operation
HOUSING
Housing type
Dimensions
Weight
Enclosure material
up to date: 03072010, modification reserved and can be change any time previous notice !
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Suitable for flush-panel mounting according to DIN 43 700.
W48xH48xD87mm
Approx. 210g (after packing)
Self extinguishing plastics
1/5
1./5 EC442-E
TERMS
EC 442
OUT
SET
PRESET
ENDA
( 1 ) PV display
( 2 ) SV display
Character height
( 3 ) Output LED
( 4 ),( 5 ),( 6 ),( 7 ) Keypad
PRESET UP/DOWN COUNTER
(1) Counting value during run mode.
PV
SV
RESET
Parameter value or mnemonic parameter code during programming mode.
(2) Preset value during run mode.
Parameter value, unit or mnemonic parameter code during programming mode.
(3) Output LED.
(4) Increment key during run and programming modes.
Parameter selection key during programming mode.
(5) Decrement or reset key during run mode.
Parameter selection or decrement key during programming mode.
(6) Used for selecting options or digits to be changed.
(7) Used for selecting run or programming modes or for adjusting the parameter.
4 digits, seven segment red LED
4 digits, seven segment yellow LED
PV display (1) : 7.1mm
SV display (2) : 7.1mm
One red LED
Micro switch
DIMENSIONS
EC 442
OUT
48mm
58mm
SET
ENDA
PRESET
PRESET UP/DOWN COUNTER
PV
SV
RESET
CONNECTION DIAGRAM
ENDA EC442 is intended for installation in control panels. Make sure that the device is used only for intended
purpose. During an installation, all of the cables that are
connected to the device must be free of energy. The device must be protected against inadmissible humidity,
vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and output
lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables
should not be close to the power cables or components.
carried on by a qualified staff and must be according to the relevant locally applicable regulations.
The shielding must be grounded on the instrument side.
Connection
cables
Flush mounting
clamp
Panel
Depth
2
For removing mounting clamps:
- Push up the flush-mounting
clamp in direction 1 as
shown in the figure above.
- Then, pull out the clamp in
direction 2.
1
1
Panel cut-out
51mm
+0.6
45 mm
+0.6
45 mm
60mm
Note 1) While panel mounting, additional distance required for
connection cables should be considered.
2) Panel thickness should be maximum 10mm.
3) If there is no 80mm free space at back side of the device,
it would be difficult to remove it from the panel.
The installation and electrical connections must be
ENDA ENDAINDUSTRIAL ELECTRONICS INDUSTRIAL ELECTRONICS
EC442 PRESET UP/DOWN COUNTER EC442-24AC PRESET UP/DOWN COUNTER
S.S. OUT S.S. OUT
RESET IN
CP2 INPUT CP2 INPUT
CP1 INPUT
GND GND
+12V 30mA +12V 30mA
SN: XXXXXXXXX SN: XXXXXXXXX
10
3
4
5
6
7
11
12
OUT
AC 250V 2A
RESISTIVE LOAD
RESET IN
CP1 INPUT
8
230V AC +10% -20%
50/60Hz 5VA
9
2
8
24V AC 10 % -20%
50/60Hz 5VA
9
2
10
3
4
5
6
7
11
12
OUT
AC 250V 2A
RESISTIVE LOAD
2/5
NOTE :
SUPPLY:
Line
184-253V AC
50/60Hz 5VA
Note :
8
Neutral
9
1) Mains supply cords shall meet the requirements of IEC 60227
Fuse
F 100 mA
250V AC
Fuse should
be connected.
Switch
or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrument
and it should be easily accessible by the operator.
Holding screw 0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
230V AC Supply
Cable size: 1,5mm²
2./5 EC442-E