Encore SP201-SA, SignalPath 201-SA Installation Manual

Page 1
encor
e
n
!
etworks
TM
SignalPath™ 201-SA
(SP201-SA™)
Installation Guide
Version C, July 2004
Part Number 15469.0100
SignalPath Software Version 1100
This Installation Guide presents a quick, standard installation of the SP201-SA.
Note: The needs of your network may require an installation that varies from the standard installation. For a customized installation, see the SP201-SA Customization and Maintenance Guide. For hardware information, see the SP201-SA Hardware Reference Guide.
The SP201-SA is available in two versions:
• The two-port SP201-SA, supporting one trunk circuit of up to 30 channel circuits
• The four-port SP201-SA, supporting up to two trunk circuits of up to 30 channel circuits each (for a total of up to 60 channel circuits)
Note: A standard trunk circuit (from one external device, through the SP201-SA, to another external device) comprises trunk connections to two ports. The SignalPath™ configuration software defines each side of the trunk circuit (that is, each connection to a port) as a trunk.
This document uses the term trunk to indicate a connection to one port; it uses the term trunk circuit to indicate the complete end-to-end connection (over two ports). Using these definitions, a trunk circuit comprises two trunks.
Before you start this installation, be sure you have filled out the worksheet for adding this device to your network. See the SP201-SA Site Planning Worksheet.
See the following sections for a standard installation of the SP201-SA:
Section A, Physical Installation
Section B, Port Configuration
Section C, Clocking Configuration
Section D, Trunk Configuration
Section E, Channel Configuration
Section F, SP201-SA Warmstart
Copyright 2003 Encore Networks, Inc.
All rights reserved.
Page 2
2 SP201-SA™ Installation Guide
Figure 1. SP201-SA Chassis
Note: The cables you connect to the SP201-SA depend on the protocols. The following table lists the ports and line each protocol uses in this guide’s standard installation.
A Physical Installation
1. Place the SP201-SA on a tabletop or shelf.
2. Connect the cables for one set of trunks to the ports on the rear of the SP201-SA chassis, as follows:
a For the CAS trunk (DTMF, R1, R2, or N5), do one of the following:
For DTMF or R1, connect a T1 cable to the RJ48C port labeled Port 1.
or
For R2 or N5, connect an E1 cable in one of the following ways:
- Connect an E1 cable to the RJ48C port labeled Port 1.
or
- Connect an E1 cable to the BNC Rx and Tx ports labeled Port 1.
b For the ISDN trunk, do one of the following:
For ETSI ISDN on a two-port SP201-SA, connect an E1 cable to the RJ48C port labeled Port 2.
(For ETSI ISDN on a four-port SP201-SA, connect an E1 cable to the RJ48C port labeled Port 3.)
or
For NI2 ISDN on a two-port SP201-SA, connect a T1 cable to the RJ48C port labeled Port 2.
(For NI2 ISDN on a four-port SP201-SA, connect a T1 cable to the RJ48C port labeled Port 3.)
Protocol Group Protocol
Port on
Two-Port
SP201-SA
Ports on Four-Port SP201-SA
Line
Channel-Associated Signaling (CAS)
DTMF 1 1, 2 T1
R1 1 1, 2 T1
R2 1 1, 2 E1
ISDN ETSI ISDN 2 3, 4 E1
NI2 ISDN 2 3, 4 T1
Page 3
SP201-SA™ Installation Guide 3
Note: Channels on trunk 1 of the two-port SP201-SA map to channels on trunk 2, and vice versa.
In a standard installation of the four-port SP201-SA, channels on trunk 1 map to channels on trunk 3 (and vice versa), and channels on trunk 2 map to channels on trunk 4 (and vice versa).
3. If you are installing a four-port SP201-SA, connect another set of trunks to ports on the rear of the chassis, as follows:
a For the CAS trunk (DTMF, R1, or R2), do one of the following:
For DTMF or R1, connect a T1 cable to the RJ48C port labeled Port 2.
or
For R2, connect an E1 cable to the RJ48C port labeled Port 2.
b For the ISDN trunk, do one of the following:
For ETSI ISDN, connect an E1 cable to the RJ48C port labeled Port 4.
or
For NI2 ISDN, connect a T1 cable to the RJ48C port labeled Port 4.
4. Connect the SP201-SA to its external power supply. Then connect the power supply to a power source (a power outlet), and switch the power on.
Note: Shipments within North America include a power cable for connection to the power outlet. For shipments outside North America, contact your distributor for a cable that meets local requirements to connect the power supply to an outlet.
5. Connect an RJ45 cable from the RJ45 Supervisory port of the SP201-SA to the DB9 COM port of a control terminal—for example, a PC. (An RJ45-to-DB9 adapter is included with the cable.)
6. On the control terminal, start a terminal emulation program, such as HyperTerminal. Configure the serial communications for the control terminal as follows:
When communication has been established, you should see the user> prompt.
7. If you don’t see a prompt, press Enter once.
The user> prompt appears.
Note: After you have connected a local terminal to the SP201-SA device, you can connect a remote terminal to the local terminal and manage the device from a remote location. See the document Remote Access to SignalPath™ Devices.
Baud rate 9600 bps Data bits 8 Parity None Stop bit 1 Flow control None
Page 4
4 SP201-SA™ Installation Guide
B Port Configuration
What the terminal displays What you type What you are configuring
user> config lim
Interfaces for the SP201-SA’s ports
List of Valid LIMs
1) 1 E1 120 Ohm/1 E1 120 Ohm
2) 2 T1 100 Ohm/1 E1 120 Ohm
3) 1 T1 100 Ohm/1 T1 100 Ohm
4) 2 T1 100 Ohm/2 T1 100 Ohm
5) 1 E1 120 Ohm/1 T1 100 Ohm
6) 1 E1 120 Ohm/2 T1 100 Ohm
7) 1 T1 100 Ohm/1 E1 75 Ohm
8) 1 T1 100 Ohm/1 E1 120 Ohm
9) 1 E1 75 Ohm/1 T1 100 Ohm
10) 1 E1 75 Ohm/1 E1 75 Ohm > 11) 1 E1 75 Ohm/1 E1 120 Ohm <
12) 1 E1 120 Ohm/1 E1 75 Ohm
13) 2 T1 100 Ohm/2 E1 75 Ohm
14) 2 T1 100 Ohm/2 E1 120 Ohm
15) 2 E1 75 Ohm/2 T1 100 Ohm
16) 2 E1 75 Ohm/2 E1 75 Ohm
17) 2 E1 75 Ohm/2 E1 120 Ohm
18) 2 E1 120 Ohm/2 T1 100 Ohm
19) 2 E1 120 Ohm/2 E1 75 Ohm
20) 2 E1 120 Ohm/2 E1 120 Ohm
Enter LIM Choice fro m list above [1-20] (current=11) ==>
Ports 1 and 2/Ports 3 and 4
Select the configuration that supports your SP201-SA’s port connections, and press the Enter key. (The List of Valid LIMs shown is for a four-port SP201-SA.)
Note: The standard choices shown below, in boldfaced numbers, include 120-ohm E1 interfaces. E1 interfaces may instead use 75 ohms over a BNC connector. If you use BNC connectors, choose an appropriate combination from the List of Valid LIMs above.
Protocol Conversion
Interfaces
DTMF–ETSI ISDN T1/E1 DTMF–NI2 ISDN T1/T1 R1–NI2 ISDN T1/T1 R2–ETSI ISDN E1/E1 R2–NI2 ISDN E1/T1
2-Port 4-Port
814 34 34 120 518
(A message similar to the following appears only if you change the LIM configuration.)
LIM set to: 2 E1 120 Ohm/2 E1 120 Ohm
A coldstart is requi red for this change to take effect
Do you wish to reset now (y/n)?
y (You must do this
now, so that subsequent configuration parameters will reflect the SP201-SA’s port configuration.)
Implementation of port configuration
Page 5
SP201-SA™ Installation Guide 5
C Clocking Configuration
(Information on tests and restarts)
(Boot banner and boot> prompt)
(Do not type anything. The application will load in a few seconds.)
(Initializations)
(Application banner and user> prompt)
(When you see the user> prompt, the SP201-SA is ready for further configuration.)
What the terminal displays What you type What you are configuring
user> config clocks
Clocking (synchronization) for the SP201-SA
Enter the trunk num ber [1-4] from which this card is to derive its clock source. Or en ter "0" if this card is to use its internal clock.
The PRIMARY clock source is derived from (current = INTERNALCLOCK): 1
Clock sourced from the device connected to the remote end of the R2 trunk
The SECONDAR Y clock source is d erived from (current = INTERNALCLOCK): 0
Backup clock sourced from the SP201-SA
user>
(Clocking has been configured.)
What the terminal displays What you type What you are configuring
Page 6
6 SP201-SA™ Installation Guide
D Trunk Configuration
Perform the following procedure once for each trunk on the SP201-SA.
What the terminal displays What you type What you are configuring
user>
config framer
p
where p is the port number (1, 2, 3, or 4) Trunk on port p
WARNING: Configuring framers will cause LOSS of calls! !!!!!!! Do you wish to proceed anyway (Y/N) : y
For a T1 line:
LIM type: 2 T1 100 Ohm/2 E1 120 Ohm 1 D4 SF 2 D4 ESF enter T1 frame type (currently D4 SF):
For T1 lines: 1
or your T1 frame type)
For an E1 line:
LIM type: 2 E1 120 Ohm/2 E1 120 Ohm
1 G704 CRC 2 G704 noCRC 3 G704 MF CRC 4 G704 MF noCRC
enter E1 frame type (currently
G704 MF no CRC):
For E1 lines: 3
(or your E1 frame type) Frame type for trunk
For T1 lines:
line coding type choices are: 1 AMI 2 B8ZS enter line coding type (currently B8ZS) :
For T1 lines: 2
(or your T1 line coding)
For E1 lines:
line coding type choices are: 1 AMI 2 HDB3 enter line coding type (currently HDB3) :
For E1 lines: 2 (or your E1 line coding)
Line coding for trunk
For T1 lines:
line length choices are: 1 0 to 115 feet 2 82 to 213 feet 3 180 to 312 feet 4 279 to 410 feet 5 377 to 509 feet 6 476 to 607 feet 7 574 to 689 feet enter line length (curre ntly 0-115 feet):
1 (or your T1 cable length)
T1 cable length
user >
(The trunk has been configured.)
Page 7
SP201-SA™ Installation Guide 7
E Channel Configuration
See the following sections to configure the protocols in your SP201-SA:
E.1 Channel Configuration for DTMF Signaling
• DTMF signaling Section E.1, Channel Configuration for DTMF Signaling
• R1 signaling Section E.2, Channel Configuration for R1 Signaling
• R2 signaling Section E.3, Channel Configuration for R2 Signaling
• N5 signaling Section E.4, Channel Configuration for N5 Signaling
• ETSI ISDN signaling Section E.5, Channel Configuration for ETSI ISDN
• NI2 ISDN signaling Section E.6, Channel Configuration for NI2 ISDN
What the terminal displays What you type What you are configuring
user> config dt all
All DTMF channels
Set 1/1 thru 2/31 out-of-service? (y or n) : <current=n> n
Placement of channels 1–31 of trunk 1 and (on the four-port SP201-SA) channels 1–31 of trunk 2 into service
DTMF Caller ID/A NI used? (y or n) : <current=n>
y (or n if caller ID is not required)
Request for caller identification
Other modifications? : (y or n) : <current=n> n
Completion of standard configuration for DTMF signaling (If y
ou wish to
configure other parameters for DTMF signaling, type y. Then refer to the SP201-SA
Customization and Maintenance Guide
.)
user>
(DTMF signaling has been configured.)
Page 8
8 SP201-SA™ Installation Guide
E.2 Channel Configuration for R1 Signaling
What the terminal displays What you type What you are configuring
user> config r1 all
All R1 channels
Set 1/1 thru 2/31 out -of-service? (y or n) : <curre nt= n> n
Placement of channels 1–31 of trunk 1 and (on the four-port SP201-SA) channels 1–31 of trunk 2 into service
Template # for defau lt IAM ? : (range 1 - 5) : <current=1> 1
Use of R1 IAM template 1
Template # for defau lt ACM ? : (range 1 - 5) : <current=1 1
Use of R1 ACM template 1
Include Feature Group D (caller ID/ ANI)? (y or n) : <curren t=n>
y (or n if caller ID is not required)
Request for caller identification
(The following four questions appear only if you answered y to the previous question.)
Use 911-Operato r Services Signali ng (y or n) : <current=n> n
No use of 911 support
Max nbr of ANI digits to send R1 (0 = all) ? : (range 0 - 32) : <current=0> 0 (zero)
Support for ANI of any size
Are Information digits supported? (y or n) : <current=n> n
No support of Information digits
Separate Wink required for B-Party Number? (y or n) : <current=n> n
No separate wink for B-Party
Require wink at end of selection? (y or n) : <current=n> n
No wink required at end of selection
Generate ringback tone for R1 originated calls? (y or n) : <current=n> n
No ringback generated for caller
user>
(Standard configuration for R1 signaling has been completed. If y
ou wish to configure other parameters for R1 signaling, refer to the
SP201-SA Customization and Maintenance Guide
.)
Page 9
SP201-SA™ Installation Guide 9
E.3 Channel Configuration for R2 Signaling
What the terminal displays What you type What you are configuring
user> config r2 all
All R2 channels
Set 1/1 thru 2/31 out- of-service? (y or n) : <current=n> n
Placement of channels 1–31 of trunk 1 and (on the four-port SP201-SA) channels 1–31 of trunk 2 into service
Select R2 converter mode : < 1> CCITT <14>Israel
< 2> Argentina <15>Korea < 3> Brazil <16>Kuwait < 4> Brazil-Emb <17>Malaysia < 5> Chile <18>Mexico < 6> China <19>New Zeala nd < 7> Columbia <20>Paraguay < 8> Columbia-Bts <21>Philippines < 9> Columbia-Ngt <22>Singapore <10> Costa Rica <23>Thailand <11> Ecuador <24>Uruguay <12> Greece <25>Venezuela <13> Indonesia
Outgoing R2 converter mode? (1-25; current=CCITT) :
1 (or your country code)
The country code for the version of R2 signaling this SP201-SA will use
Request R2 caller ID? (y or n) : <current=n>
y (or n if caller ID is not required)
Request for caller identification
Send I15 to R2 side at end of a ddress (vs timeout)? (y or n) : <current=y>
y (or n, depending on your requirement)
Sending an Address Complete code (An answer of n causes the adjacent switch to wait for the appropriate timer to expire before processing the call.)
Other modifica tions? : (y or n) : <current=n> n
Completion of standard configuration for R2 signaling (If y
ou wish to configure other
parameters for R2 signaling, type y. Then refer to the
SP201-SA Customization and Maintenance Guide
.)
user>
(R2 signaling has been configured.)
Page 10
10 SP201-SA™ Installation Guide
E.4 Channel Configuration for N5 Signaling
What the terminal displays What you type What you are configuring
user> config n5 all
All N5 channels
Set 1/1 thru 2/31 out- of-service? (y or n) : <curren t= n> n
Placement of channels 1–31 of trunk 1 and (on the four-port SP201-SA) channels 1–31 of trunk 2 into service
Destination country code for calls to N5 (current) : Enter up to 3 digits: (your country code)
Your country’s international dialing code
Transit calls to N5 enabled ? (y or n) : <current=n> n
Disallowance of transit traffic
Use Calling Pa rty Ca tego ry to set N5 language digit? (y or n) : <current=n> n
No use of the calling party category to derive the language digit
N5 side outgoing language digit (current) : Enter up to 1 digits:
(Press Enter to leave this field empty.)
The fixed language digit for calls originating from the N5 side
Prefix to be strippe d from digits before sending to N5 (current) : Enter up to 3 digits:
(Press Enter to leave this field empty.)
Digits to remove from the front of the country code
Digits that cause C1 1 to be sent to N5 (current) : Enter up to 18 digits:
(Press Enter to leave this field empty.)
Digit string that causes the C11 operator code to be sent to N5
Digits that cause C1 2 to be sent to N5 (current) : Enter up to 18 digits:
(Press Enter to leave this field empty.)
Digit string that causes the C12 operator code to be sent to N5
Language digit expected from N5 [* = any] (current) : Enter up to 1 digits:
(Press Enter to leave this field empty.)
Acceptance of calls only with a specific language digit (if entered)
Transit calls FROM N5 enabled ? (y or n) : <current=n> n
Rejection of transit calls (by returning a busy flash)
Digits to prepend in non-transit calls coming from N5 (current) : Enter up to 3 digits:
(Press Enter to leave this field empty.)
Digits to prepend to non­transit calls
Use calling party ca tegory from template ? (y or n) : <cur rent=n> n
Derivation of the Calling Party Category from the N5 language digit
Digits to send when C1 1 is received from N5 (current) : Enter up to 18 digits:
(Press Enter to leave this field empty.)
The digit string to send when the C11 operator code is received from N5
Digits to send when C1 2 is received from N5 (current) : Enter up to 18 digits:
(Press Enter to leave this field empty.)
The digit string to send when the C12 operator code is received from N5
Page 11
SP201-SA™ Installation Guide 11
Template # for default IAM ? : (range 1 - 5) : <current=1> 1
Default values for IAM parameters required on the SS7 side but not specified by the N5 protocol
Template # for default ACM ? : (range 1 - 5) : <current=1> 1
Default values for ACM parameters required on the SS7 side but not specified by the N5 protocol
Use user-defined caller ID (ANI) in calls from N5? (y or n) : <current=n> n
No support of caller ID (ANI).
Note: Although N5 does not use ANI, some networks require ANI in all calls. Answering y here places a fixed ANI in each call originating from N5.
Generate ringback tone for N5 originated calls? (y or n) : <current=n> n
No ringback generation by SignalPath for calls from N5 device
user>
(This completes standard configuration of N5 signaling. If you wish to customize the configuration of N5 signaling, refer to the SP201-SA
Customization and Maintenance Guide.)
What the terminal displays What you type What you are configuring
Page 12
12 SP201-SA™ Installation Guide
E.5 Channel Configuration for ETSI ISDN
In the two-port SP201-SA, perform the following procedure once for trunk 2. In the four-port SP201-SA, perform the procedure once each for trunks 3 and 4.
Note: If you are performing this procedure on a two-port SP201-SA, read trunk 3 as trunk 2.
What the terminal displays What you type What you are configuring
user> config dchans
ISDN signaling channel
The following is the present Trunk configuration. If a change to the Timeslot or Interface Type is de sired Enter the Trunk number you wish to modify or exit:
Trunk Signaling Timeslot Trunk Link Interface Protocol Type Type State Type
------------------------------------------------------------------------­3 D 16 E1 Inactive Network ETSI ISDN 4 D 16 E1 Inactive Network ETSI ISDN
ISDN Trunk Number
Enter value(3 - 4) or "exit" :
p
where p is the port number (3 or 4) ISDN trunk p
Select interfac e type - user(0) or network(1) : <curr ent=1> 1 (or 0)
SP201-SA as the Network role (or as the User role) in this
ISDN connection
ISDN Interface num ber 1 assigned to Trunk
p
,
with a D Channel on time slot 16.
Change ISDN Signal ing Channel
Enter value(1 - 31; current="16") or "exit" : 16
Signaling timeslot
(The following message appears only if you change the channel number used as the signaling timeslot.)
Changes applied
The card must be reset for the changes to operate properly Do you wish to reset now (y/n)?
n
Delay in implementation of changes until performing a warmstart (described in
Section F, SP201-SA
Warmstart)
not resetting.. .
user>
(ISDN signaling has been configured on this trunk.)
Page 13
SP201-SA™ Installation Guide 13
E.6 Channel Configuration for NI2 ISDN
In the two-port SP201-SA, perform the following procedure once for trunk 2. In the four-port SP201-SA, perform the procedure once each for trunks 3 and 4.
Note: If you are performing this procedure on a two-port SP201-SA, read trunk 3 as trunk 2.
What the terminal displays What you type What you are configuring
user> config dchans
ISDN signaling channel
The following is th e present Trunk configuration. If a change to the Time slot or Interface Type is desired Enter the Trunk num ber you wish to modify or exit:
Trunk Signaling Timesl ot Trunk Link Interface Protocol Type Type State Type
------------------------------------------------------------------------­3 D 24 T1 Inactive Network NI2 ISDN 4 D 24 T1 Inactive Network NI2 ISDN
ISDN Trunk Number
Enter value(3 - 4) or "exit" :
p
where p is the port number (3 or 4) ISDN trunk p
Select interface type - user(0) or network(1) : <current=1> 1 (or 0)
SP201-SA as the Network role (or as the User role) in this
ISDN connection
ISDN Interface number 1 assigned to Trunk
p
,
with a D Channel on timeslot 24.
Change ISDN Signaling Channel
Enter value(1 - 31; current="24") or "exit" : 24
Signaling timeslot
(The following message appears only if you change the channel number used as the signaling timeslot.)
Changes applie d
The card must be rese t for the changes to operat e properly Do you wish to reset no w (y/n)?
n
Delay in implementation of changes until performing a warmstart (described in
Section F, SP201-SA
Warmstart)
not resetting...
user>
(ISDN signaling has been configured on this trunk.)
Page 14
14 SP201-SA™ Installation Guide
F SP201-SA Warmstart
This completes the standard installation. To configure other parameters, see the SP201-SA Customization and Maintenance Guide. For hardware specifications, see the SP201-SA Hardware Reference Guide.
What the terminal displays What you type What you are configuring
user> warmstart
Implementation of the ISDN configuration
This action will drop any calls that are in progress. Do you really want to continue? (y/n): y
(Information on tests and restarts)
(Boot banner)
boot>
(Do not type anything. The application will load in a few seconds.)
(Initializations)
(Application banner)
user>
(When you see the user> prompt, the SP201-SA is ready for use.)
Loading...