Enable Lifecare Joerns Hoyer Presence User Manual

Product name to go here
Product description to go here
USER MANUAL
U S E R M A N U A L
Hoyer ® Presence
To avoid injury, read user manual prior to use.
Joerns Hoyer Presence
enablelifecare.com.au
®
Contents
1. The Hoyer Presence Patient Lift..................................................................................... 3
2. Introduction: About Your Lift......................................................................................... 4
3. Assembly and Commissioning Instructions............................................................... 5
4. Safety Precautions........................................................................................................... 9
5. Standard Control Box & Handset.................................................................................. 11
6. Smart Monitor & Handset................................................................................................ 12
7. Operating Instructions..................................................................................................... 16
8. Removal of Spreader Bar/Cradle Systems................................................................. 19
9. Charging Instructions...................................................................................................... 21
10. Maintenance Schedule & Daily Check List................................................................ 22
11. Technical Specifications................................................................................................. 24
12. Warranty............................................................................................................................ 27
Joerns Hoyer Presence
®
2
1. The Hoyer Presence Patient Lift
Oxford
®
Presence
Battery/ Control Pack
Push Handle
Mast Extrusion
Boom
Electric Actuator
Spreader Bar
Rear Castor (braked)
Joerns Hoyer Presence
®
Front Castor (non-braked)
3
2. Introduction: About Your Lift
Each Presence lift is fully assembled, load tested and certified before being packed/shipped.
The packing consists of a strong, purpose built carton that is used for both export and domestic markets to ensure the safe arrival of the lift. A number of documents are supplied in a wallet, and packed with each lift and should be kept safely for future reference.
• TEST CERTIFICATE
• USER MANUAL
The TEST CERTIFICATE is an important document and should be kept for reference purposes.
To properly maintain your lift please refer to the maintenance schedule included in this document. If you are at all unsure what your country’s servicing requirements are, please check with your dealer and/or a local government agency.
Statement of Intended Use
The intended use of this lifting device is for the safe lifting and transfer of an individual from one resting surface to another (such as a bed to a wheelchair). Joerns Healthcare recommends that the transfer of a patient is fully risk assessed and conducted safely over a short distance only.
The Hoyer Presence is suitable for patients in the SIT TING, SITTING/RECUMBENT and RECUMB ENT positions.
The Hoyer Presence is an electrically operated patient lift, designed to support and promote safe patient handling and transfer for both the patient and carer.
The Hoyer Presence lift incorporates a 6-point cradle as standard and is designed to be used in conjunction with the Hoyer range of slings. A 4-point cradle option is available as an add-on accessory. The examples of slings suitable for use with this device are listed as follows:
• Hoyer Quickfit
• Hoyer Full Back
• Hoyer Quickfit Deluxe
• Hoyer Long Seat
• Hoyer Access
• Hoyer Comfort
Expected Service Life
Hoyer Professional lifts are designed and tested for a minimum service life of ten (10) years, subject to the use and maintenance procedures stated in this manual. Use, other than in accordance with these instructions, may compromise service life.
Joerns Hoyer Presence
®
4
3. Assembly and Commissioning Instructions
Oxford
®
Presence
English
3. Assembly and Commissioning Instructions
Carton Contents
Place the carton in a clear working area and open carefully. The carton contains:
OXFORD PRESENCE LIFT
WALLET CONTAINING DOCUMENTS
HAND CONTROL
BATTERY PACK
CHARGING LEAD
DESK TOP CHARGER/STAND
WARNING
The Oxford Presence is heavy and will need to be lifted with care. You may need assistance to lift the Oxford Presence from the carton.
Assembly Instructions
1. Remove all the parts from the carton and place on the floor, taking care to protect the finish
from damage.
Place the chassis in a clear space and apply the rear bakes.
Oxford
®
Presence
WARNING
Carton Contents
Place the carton in a clear working area and open carefully. The carton contains:
• BATTERY PACK
• CHARGING LEAD
• DESK TOP CHARGER/STAND
• HOYER JOURNEY LIFT
• WALLET CONTAINING DOCUMENTS
• HAND CONTROL
The Hoyer Presence is heavy and will need to be lifted with
WARNING
!
care. You may need assistance to lift the Hoyer Presence from the carton.
Assembly Instructions
1.
Remove all the parts from the carton and place on the floor, taking care to protect the finish from damage.
Place the chassis in a clear space and apply the rear bakes.
Fit the mast and boom assembly into the chassis socket.
2.
Joerns Hoyer Presence
®
5
3.
English
®
English
chassis.
WARNING
The fixings and wrench needed to attached the handle are kept in the user instruction wallet for safe keeping.
handle before fixing.
Tighten the mast assembly with the mast-locking device, which is located at the front of the chassis.
Avoid trapping fingers. Keep fingers away from the end of the mast when inserting into the chassis socket. Full engagement of
CAUTION
!
4.
Turn the locking knob until hand tight.
5.
Line the handle assembly up to the rear of the mast, and attach using the screws provided. The screws and wrench needed to attached the handle are kept in the user instruction wallet for safe keeping.
Note: When attaching the handle to the mast be sure that all trailing wires are left outside the
handle before fixing.
the mast is indicated by the label on the side of the mast. The electric leg operation will not function unless the mast is fully engaged.
6.
Fit power pack to the lift and make sure the latch holding the pack in place is fully engaged. “Click” in place.
7.
Plug the handset and actuator cables into the bottom of the controller. Refer to the figures on page 11 or 12 for correct positions.
Joerns Hoyer Presence
®
6
Oxford
®
Presence
English
DISASSEMBLY
The lift should not be disassembled unless for service, repair or transport if necessary. If disassembly is required, simply follow the assembly instructions in reverse sequence.
ALWAYS CHECK THE FOLLOWING BEFORE OPERATION
The mast is fully locked into position.
Oxford
®
Presence
English
DISASSEMBLY
The lift should not be disassembled unless for service, repair or transport if necessary. If disassembly is required, simply follow the assembly instructions in reverse sequence.
ALWAYS CHECK THE FOLLOWING BEFORE OPERATION
The mast is fully locked into position.
The legs of the lift open and close satisfactorily (This is done via the hand control).
Oxford
®
Presence
Disasseambly
The lift should not be disassembled unless for service, repair or transport if necessary. If disassembly is required, simply follow the assembly instructions in reverse sequence.
ALWAYS CHECK THE FOLLOWING BEFORE OPERATION
• The mast is fully locked into position.
• The legs of the lift open and close satisfactorily (This is done via the hand control).
• The red emergency stop button, located on the rear of the control box, is in the OFF (out) position.
Joerns Hoyer Presence
®
7
• Push the up and down buttons on the hand control and confirm the boom rises and lowers.
Oxford
®
Presence
English
Push the up and down buttons on the hand control and confirm the boom rises and lowers.
Joerns Hoyer Presence
®
8
4. Safety Precautions
Please read and follow the safety precautions listed below. The operation and use of Hoyer patient lifts is simple and straightforward. Following these few basic safety precautions will make lifting operations easy and trouble free.
READ AND UNDERSTAND THE USER INSTRUCTION MANUAL BEFORE USING YOUR Hoyer Journey
WARNING: Important safety information for hazards that might cause serious injury.
CAUTION: Information for preventing damage to the product.
NOTE: Information to which you should pay special attention.
WARNING
!
DO NOT lift a patient unless you are trained and competent to do so.
ALWAYS carry out the DAILY CHECK LIST located towards the end of the manual before using the lift.
DO NOT exceed the safe working load of the lift.
ALWAYS plan your lifting operations before commencing.
ALWAYS familiarize yourself with the operating control and safety features of a lift before lifting a patient.
DO NOT use a sling unless it is recommended for use with the lift.
ALWAYS check the sling is suitable for the particular patient and is of the correct size and capacity.
NEVER use a sling, which is frayed or damaged.
ALWAYS fit the sling according to the instructions provided (user instructions).
ALWAYS check the safe working load of the lift is suitable for the weight of the patient.
ALWAYS carry out lifting operations according to the instructions in the user manual.
NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift.
ALWAYS lock the wheels when lifting from the floor.
DO NOT attempt to manoeuvre the lift by pushing on the mast, boom or patient.
ALWAYS manoeuvre the lift with the handle provided. A foot push pad is also provided.
DO NOT push a loaded lift at speeds, which exceed a slow walking pace (2.6 ft/sec).
Joerns Hoyer Presence
®
9
Loading...
+ 19 hidden pages