EMX Industries, Inc. Hawk 1 Operating Instructions Manual

SPECIFICATIONS
Operating frequency 24.150 GHz Output power (EIRP) <20dBm Detectable speed 0.1 m/s min. Vertical directionality 0…60° Horizontal directionality +/- 45° Installation height Max. 3 m Range 1…5 m adjustable Relay control time 1…6 sec. adjustable Relay output configuration Form C (SPDT) Relay contact rating 1A @ 24V AC/DC Detection indicator Red LED Operating temperature -4°F…122°F (-20°C…50°C) Supply Voltage 12…24 VDC/VAC Operating current Max. 40mA
Dimensions
Weight 0.55lbs. (250 g) Housing ABS (plastic) Connection 5 position terminal block Mechanical protection IP55
5.5”(140mm) x 4.0”(100m) x
2.8”(70mm)
CAUTIONS AND WARNINGS
This product is an accessory or part of a system. Always read and follow the manufacturer’s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death
WARRANTY
4564 Johnston Parkway
Cleveland, Ohio 44128
United States of America
Technical Support Telephone (216) 834-0761
Sales E-mail salessupport@emxinc.com
HAWK 1 Operating Instructions REV1.4 7.16.13
WEB http://www.emxinc.com
E-mail: technical@emxinc.com
Telephone (216) 518-9888
Fax (216) 518-9884
HAWK 1
P E D E S T R I A N M O T I O N S E N S O R
OPERATING INSTRUCTIONS
MATERIALS SUPPLIED
Operating Instructions
HAWK 1 Sensor
GENERAL DESCRIPTION
The HAWK 1 is a planar technology microwave detector working in the K band. It is the ideal solution for operating all types of automatic doors. It detects the movement of people in the monitored area.
Easy to install at a height of up to 3 meters (10ft.), it has a versatile mechanical orientation system for accurate positioning to the required coverage area.
The detection sensitivity and direction of movement (toward, away or both) are programmed by DIP switch setting. A microprocessor processes the received Doppler signals and provides set of form C relay contacts for external connection.
The LED on the front of the HAWK 1 indicates detection.
SET-UP
The HAWK 1 motion sensor can be configured in the mono direction mode (one direction only) or in the bi-directional mode (both directions). Remove cover from the base of the detector and set the required function using the DIP-switch (FIG. 1-A) settings per the following table.
Setting the detection range It is possible to define the controlled area by changing the angle of the detector and the position of the DIP-switch 4 (Fig. 1-A). Using trimmer TR1 (FIG. 1-E) the sensitivity can be optimized to activate detection only for the desired area.
SW1 SW2 SW4 SENSITIVITY FUNCTION
OFF - ON Low Detect in both
directions
OFF - OFF High Detect in both
directions
ON OFF ON Low Detect
approaching
ON OFF OFF High Detect
approaching
ON ON ON Low Detect leaving
ON ON OFF High Detect leaving
Relay contact setting The HAWK 1 output is a form C set of relay contacts. The setting options are indicated in the following table. These conditions are valid when the device is powered.
INSTALLATION
The HAWK 1 can be installed at the center of the door to be controlled, or on the side on non-vibrating structures (walls or ceiling) at a maximum height of 10ft. Use the template supplied with the unit for preparing the mounting holes.
Remove the cover and insert the wires and tighten them to the terminal block as indicated in Fig. 2. Route the cable out the back of the device and thought the grooves in the case. Fasten the device using the prepared hole. Aim the detector (Fig. 1-C) toward the area to be controlled and re-attach the cover.
For proper operation, do not install HAWK 1:
Facing the moving parts of a door
Facing fluorescent lights (minimum distance 6.5 ft.)
Facing area where rain could provoke water fluxes
These conditions could cause undesired opening of the door.
WIRING
See Fig. 2.
SENSITIVITY PATTERNS
Adjusting activation period Trimmer TR2 (Fig. 1-F) is used to set the desired duration of the output contact, variable form 1 to 6 seconds.
Loading...