Functions Description
Function Description
Door Unlock Time Setting Assign Door Unlock Time (or Door Relay Activated Time). The Door Unlock
Time is keypad programmable and can be programmed as -
Toggle Mode: Latched-on/Latched-off or
Momentary Mode: 1 ~ 600 seconds or 0.1 ~ 39.9 seconds.
Default setting: 2 seconds.
Alarm Time Setting Assign Alarm Time (or Alarm Relay Activated Time). The Alarm Time is
keypad programmable and can be programmed as -
Latched-on Mode or
Momentary Mode: 1 ~ 600 seconds
Default setting: 2 seconds.
Arming Delay Time Setting Once the arming function is set, after a certain period of Arming Delay Time,
the system will enter Arming Mode and 1) the system engages the Timing 2
Sequences if door is close or 2) wait until door is closed to engage the Timing 2
Sequences if door is open. By setting Arming Delay Time, user can have
enough time to go out without activating the alarm system. The Arming Delay
Time is keypad programmable and can be programmed from 1 ~ 600 seconds.
Default setting: 1 second.
Alarm Delay Time Setting When the door is close and the system is in Arming Mode, open the door will
activate the alarm relay after a certain period of delay time (Door Unlock Time
+ Arming Idle Time + Alarm Delay Time). To avoid the alarm generated, user
can close the door within "Door Unlock Time + Arming Idle Time" delay period
and system is still in Arming Mode, or just enter disarm process within "Door
Unlock Time + Arming Idle Time + Alarm Delay Time" period and system is in
Disarming Mode. The Alarm Delay Time is keypad programmable and can be
programmed from 1 ~ 600 seconds.
Default setting: 3 seconds.
If door is opened and in Latched-off mode, the delay time is infinite and there
will be no alarm activated.
Arming Idle Time Setting This idle time can provide user an enough time to close the door without
entering Alarm Delay Time period. Once system enters Alarm Delay Time
period, the user has to disarm the system to avoid the alarm generated. The
Arming Idle Time is keypad programmable and can be programmed from 1 -
600 seconds.
Default setting: 15 seconds.
Power on Arming After power on, the arming is set automatically and system enters Time 1
Sequence. This feature is keypad programmable. Please refer to Command 20.
Default setting: Disable power on Arming.
Door Monitored & Re -lock To prevent "tailgating", door is monitored and automatically locked when entry is
completed and door is closed for at least 2 seconds.
This feature is keypad programmable and isn't effective if the Door Unlock
Time setting is in Latched-on mode. Please refer to Command 20.
Default setting: Disable Auto Re-lock function.
Door Exit Release A door exit push-button or infrared detector to unlock the door from inside.
This feature is keypad programmable. Please refer to Command 20.
(Note: Push-button switch or infrared detector is not included).
Default setting: Enable Door Exit Release function.
Audible output Audible beep sound to indicate the status of key pressed or successful operation
or operation failed.
Edit Mode Timeout If no entry is made within 30 seconds, the system will exit the Edit Mode and
return to its normal operation, i.e. User Mode.
Keypad Automatic Blocking Keypad will be locked for 30 seconds if wrong key -entries are made 3 times in
User Mode. A valid or invalid card can release the keypad from blocking during
these 30 seconds.
For all the valid inputs, either by cards or by keys, the error counter will reset to
0.
For the invalid card input, the error counter will reset to 1.