EMX Industries CarSense 202 Instruction Manual

EMX Industries, Inc. Tech support: 216-834-0761 1/5
CS202_Rev1.6_070119 technical@emxinc.com
CarSense 202
Vehicle Motion Detector
Instruction Manual
The CS202 is designed to detect moving vehicles. It is not suitable for use as a vehicle
presence detector such as a reversing loop for a gate or door.
The CS202 detects ferrous metals. It will not detect aluminum but will detect any
moving ferrous metallic object.
The probe must be stationary to function properly.
Cautions and Warnings
Power
9 - 41VDC or 6 - 29VAC
Standby current
0.250mA
Detection current
12mA
Range sensitivity
12ft. @ 5 mph min. speed
Output on time
Approximately 1 second
Surge protection
Probe input circuitry protected by surge suppressors
Relay output configuration
Form C (SPDT)
Relay contact rating
1A @ 24VDC 1A @ 120VAC
Operating temperature
-40º to 82ºC (-40º to 180ºF) 0 to 95% relative humidity
Probe housing material
PVC watertight
Probe dimensions (L x Dia.)
24” (610 mm) x 1” (25 mm)
Probe cable
5-wire, direct burial
Specifications
TM
EMX Industries, Inc. Tech support: 216-834-0761 2/5
CS202_Rev1.6_070119 technical@emxinc.com
CS202S-5W-50 CarSense 202 5-wire, 50ft. lead-in wire
CS202S-5W-100 CarSense 202 5-wire, 100ft. lead-in wire
CS202S-5W-XX CarSense 202 5-wire, (enter required length in ft.) lead-in wire
Wiring Connections
Accessories for CS202
Wire Color
Description
Red
Power + (9 to 41VDC or 6 to 29VAC)
Black
Power – (9 to 41VDC or 6 to 29VAC)
Green
Common (relay common contact)
White
N.C. (relay normally closed contact)
Brown
N.O. (relay normally open contact)
Red
Power + (6 to 29VAC)
Black
Power – (6 to 29VAC)
White
N.C. (relay normally closed contact)
Brown
N.O. (relay normally open contact)
Green
Common (relay common contact) and earth ground
White
N.C. (relay normally closed contact)
Brown
N.O. (relay normally open contact)
Green
Common (relay common contact)
Red
Power + (9 to 41VDC)
Black
Power – (9 to 41VDC) and earth ground
IMPORTANT: EARTH GROUND CONNECTION
The CS202 contains transient protection devices to guard the sensitive electronic circuitry from damage and false triggering due to electrical transients caused by lightning or other sources. Always provide a good earth ground. An 8ft. copper rod or metal cold-water pipe provides a sufficient earth ground connection.
When using AC power, connect the CS202 green common relay and earth ground wire to the operator.
When using DC power, connect the CS202 black power (–) wire and the operator’s ground, common or power (–) lead to the earth ground.
AC Wiring Diagram
DC Wiring Diagram