Emulex LP21000, LP21002 СТФ Installation Manual

Page 1
LP21000 and LP21002 CNA
Installation Manual
Last updated September 19, 2008 Critical Connectivity Solutions
TM
Page 2
Copyright© 2008 Emulex. All rights reserved worldwide. No part of this document may be reproduced by any means nor translated to any electronic medium without the written consent of Emulex.
Information furnished by Emulex is believed to be accurate and reliable. However, no responsibility is assumed by Emulex for its use; or for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Emulex.
Emulex, AutoPilot Installer, BlockGuard, cLAN, FabricStream, FibreSpy, Giganet, HBAnyware, InSpeed, IntraLink, LightPulse, MultiPulse, SAN Insite, SBOD and Vixel are registered trademarks, and AutoPilot Manager, Critical Connectivity Solutions, EZPilot, SLI and VMPilot are trademarks of Emulex. All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations.
Emulex provides this manual "as is" without any warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Emulex may make improvements and changes to the product described in this manual at any time and without any notice. Emulex assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties that may result. Periodic changes are made to information contained herein; although these changes will be incorporated into new editions of this manual, Emulex disclaims any undertaking to give notice of such changes.
LP21000 and LP21002 Hardware Installation Manual Page ii
Page 3
Table of Contents
Introduction................................................................................................................................................... 1
Major Features ................................................................................................................................ 1
Compatibility ....................................................................................................................................2
Prerequisites.................................................................................................................................... 2
Installing the Converged Network Adapter ................................................................................................... 3
Attaching Media............................................................................................................................................ 4
Applying Power............................................................................................................................................. 5
Viewing the LEDs ............................................................................................................................5
POST Conditions and Results ......................................................................................................... 5
Typical EE Configuration Diagram 1-2 CNAs .............................................................................................. 7
Server Requirements....................................................................................................................... 7
References ................................................................................................................................................... 8
Specifications ..................................................................................................................................8
LP21000 and LP21002 Hardware Installation Manual Page iii
Page 4
Introduction
This manual describes Emulex® LP21000 and LP21002, multi-protocol PCI-Express Converged Network Adapters (CNAs) for a 10 Gigabit Enhanced Ethernet (EE) fabric. Emulex CNAs provide both traditional networking interface card (NIC) functionality and host-bus-adapter (HBA) functionality, as well as Fibre Channel over Ethernet(FCoE) functionality for convergence of Fibre Channel traffic onto 10 Gigabit EE fabric.
Emulex CNAs combine four major functional components: a 10G networking MAC, a Fibre Channel IOC, a PCI-express-switch (to bridge between the MAC and IOC), and a bridge chip that interconnects the 10G MAC and Fibre Channel IOC and interfaces with a unified lossless Ethernet switch. The CNA serves as a common interface for both storage and IP traffic retaining familiar Fibre Channel and networking software stacks, OS drivers, and management. The supported PCIe connector is x8 or higher. Each CNA is compliant to the PCI Express Base Specification 1.1.
Major Features
Available in four different models:
LP21000-M single port with Optics
LP21002-M dual port with Optics
LP21000-C single port with Copper
LP21002-C dual port with Copper
Single 8-lane standard Gen 1, PCIe interface shared by the Fibre Channel and MAC controllers through an IDT 3-port PCIe switch.
Standard PCIe form factor PCBA; full height, 9.1" long.
10 GbE Network interface connections using optics or copper.
On-board flash memory: 8M bytes for Fibre Channel controller program storage, 1M byte for FCoE Bridge program storage, and 128K bytes for PXE Ethernet boot.
On-board configuration EEPROM for the Ethernet MAC and FCoE Bridge.
Uses standard Emulex SLI drivers.
Interoperates with existing Fibre Channel SAN infrastructures - switches, arrays, SRM tools (including Emulex utilities), SAN practices, etc.
Unified Ethernet to Fibre Channel SAN connectivity provided by FCoE switch.
Provides 10G MAC features such as MSI-X support, Jumbo frames support (16K bytes), VLAN tagging (802.1Q, PER priority pause / priority flow control), and advance packet filtering.
No host operating system changes required - i.e. NIC and HBA functionality (including device management, utilities, etc.) transparent to the host operating system.
Target Systems: Tier-1 OEM rack servers of all form-factors (with PCI-Express)
LP21000 and LP21002 Hardware Installation Manual Page 1
Page 5
Compatibility
Table 1. Software and Hardware Environments
Software Environments Win2003, Win2008, RHEL5, SLES10/ 11, RHEL4, SLES9, VMware, Solaris
(Leadville)
Hardware Environments Single 8 lane PCI-Express 1.1 compliant systems
Note: Support for Solaris (Leadville) is provided for FCoE only. The Ethernet drivers will be made available as soon
as they are supported by Solaris.
Prerequisites
PCI-Express 1.0a compliant systems: x8 lane transfer link interface at 2.5-Gb/s per lane.
Single 8-lane standard Gen1, PCIe slot is required for operation.
LP21000 and LP21002 Hardware Installation Manual Page 2
Page 6
Installing the Converged Network Adapter
The Emulex LP21000 and LP21002 converged network adapters (CNAs) use removable optical transceivers. If you need to change the bracket for CNA installation, you must first remove the transceivers from the housing (cage). This document explains how to install the CNA and, if necessary, how to remove the transceivers and bracket safely.
To install a CNA:
1. Each CNA is shipped with a unique 64-bit identifier called the IEEE address. The Fibre Channel industry uses a World Wide Name (WWN) derived from the IEEE address, and this number is needed for Fibre Channel connectivity. A CNA can have one or two 10 Gigabit physical ports. IEEE addresses are assigned for each port, and are used when configuring your system. The serial number is used when communicating with Emulex. All numbers are clearly marked on the board. We recommend that you record these numbers before installation.
2. Turn off and unplug the computer.
3. Remove the computer case.
Note: Place the CNA into an empty PCIe x8 slot. Make sure that the adapter is in an
appropriate PCIe slot that does not interfere with other components or case to prevent damaged to the CNA.
4. Remove the blank pane from an empty PCIe bus slot bus slot. Follow steps 5-8 to change the brackets if they are different sizes. Otherwise, skip to step 9.
5. Remove the mounting bracket screws from the top of the CNA.
6. Remove the bracket and store it for future use.
7. Align the new mounting bracket tabs with the appropriate holes in the CNA.
Note: Be careful not to push the bracket past the transceiver housing's grounding tabs.
Make sure the light emitting diodes (LEDs) are properly aligned with the holes in the bracket.
8. Replace the screws that attach the CNA to the bracket.
9. Insert the CNA into the empty x8 PCIe bus slot. Press firmly until the adapter is seated.
10. Secure the CNA's mounting bracket to the case with panel screw or clip.
11. Replace the computer case and tighten case screws.
The CNA is now installed in the server and is ready for media attachment.
LP21000 and LP21002 Hardware Installation Manual Page 3
Page 7
Attaching Media
Note: A CNA will not allow normal data transmission on either 10 Gig optical or copper link unless it is connected to
a similar or compatible optical or copper interface connection (that is, multimode to multimode).
Use SR, DCR multimode fiber, or 3m twin-axial copper for interface connections to network that adheres to the following specifications:
Table 2. Media Specifications
Fiber Optic Cable Maximum Length Minimum Length Connector
Short Range, LC-LC Multimode OM3 - 50/125 Duplex (SFP+)
Copper Cable Maximum Length Minimum Length Connector
Twin-Axial Copper (SFP+) 3 meters (9.84 ft) 1 meter LC
300 meters (984.25 ft) 1 meter LC
To attach media to the CNA:
1. Connect the cable to the LC connectors on the CNA.
2. Connect the other end of the cable to a Top of Rack (TOR) EE switch. See figure 1.
Figure 1: Connecting Fiber Optic or Copper Cable
After the media is connected to the CNA, you are ready to apply power to the computer.
LP21000 and LP21002 Hardware Installation Manual Page 4
Page 8
Applying Power
To apply power:
1. Verify that the CNA is securely installed in the computer.
2. Verify that the correct media is attached.
3. Plug in and turn on the computer.
4. Observe LEDs for Power On Self Test (POST) results.
Viewing the LEDs
Green and yellow LEDs can be seen through openings in the CNA's mounting bracket. Each corresponding LED is summarized below:
10GbE Green (Ethernet Link)
ON Solid = Link up
ON/OFF Intermittent = Activity
OFF = No Link
Yellow (Adapter status; standard Emulex)
Green (Adapter status; standard Emulex)
Figure 2: CNA LED Indicators
POST Conditions and Results
POST (Power on Self Test) conditions and results are summarized in the following table:
Note: For the Fibre Channel Link Rate conditions, there is a 1 Hz pause when the LED is
off between each group of fast blinks (1,2 or 3). You should observe the LED sequence for several seconds to ensure that the pause is correctly identified.
Table 3. POST Conditions and Results
Yellow LED Green LED State
Off Off Wake-up failure (Dead board)
On Off POST failure (Dead board)
Slow Blink Off Wake-up failure monitor
Fast Blink Off POST failure
Flashing Off POST processing in progress
Off On Failure while functioning
On On Failure while functioning
3 Fast Blinks On 4Gb Link rate-Normal, link up
Off Slow Blink Normal-link down or not started
LP21000 and LP21002 Hardware Installation Manual Page 5
Page 9
Table 3. POST Conditions and Results (Continued)
Yellow LED Green LED State
Slow Blink Slow Blink Off-line for download
Fast Blink Slow Blink Restricted off-line mode (Waiting for restart)
Flashing Slow Blink Restricted off-line mode (Test active)
LP21000 and LP21002 Hardware Installation Manual Page 6
Page 10
Typical EE Configuration Diagram 1-2 CNAs
Figure 3: Typical EE Configuration Diagram 1-2 CNAs
Server Requirements
Visit http://www.emulex.com/support or contact Emulex Corporation with any questions or concerns about certified servers for LP21000 and LP21002.
LP21000 and LP21002 Hardware Installation Manual Page 7
Page 11
References
Specifications
Table 4. LP21000 and LP21002 Specifications
Parameter Range
Media Interface The EE NIC and Fibre Channel components interface to the physical media
interface through a FCoE bridge chip, and then connect through either single/dual port 10 Gigabit optical fiber or copper LC connectors to the Enhanced Ethernet.
Physical Dimensions Standard PCIe form factor PCBA; full height, 9.1".
Power Requirements Dual Port: 25 Watts
Single Port: 23 Watts
Airflow 150 lf/min (minimum)
Temper ature 0°C to 55°C (+32°F to +131°F)
Humidity 5% to 85% (non-condensing)
40°C, 16 hour dwells at extremes
Agency Approvals for LP21000 and LP21002
Vibration, peak acceleration
ROHS Compliance Same as HBAs
TBD
0.25g (5 Hz to 500 Hz) (Sweep Rate = 1 octave/min.)
LP21000 and LP21002 Hardware Installation Manual Page 8