Emulex LP11000, LP11000 HBA Installation Manual

Page 1
LP11000 HBA
Installation Manual
Page 2
Copyright© 2005 Emulex Corporation. All rights reserved worldwide. No part of this document may be reproduced by any means nor translated to any electronic medium without the written consent of Emulex Corporation.
Information furnished by Emulex Corporation is believed to be accurate and reliable. However, no responsibility is assumed by Emulex Corporation for its use; or for any infringements of patents or other rights of third parties which may result from its use. No licens e is grant ed by impl ication or oth erwise under any pa tent or paten t right s of Em ulex Corporation.
Emulex and LightPulse are registered trademarks, and AutoPilot Installer, AutoPilot Manager, BlockGuard, FibreSpy , HBAnyware, InSpeed, MultiPulse, SLI and SBOD are trademarks, of Emulex Corpo ration. All other b rand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations.
Emulex provides this manual "as i s " wi thout any warranty of any kind, either express ed o r i mp lie d , i nclud i ng but n ot limited to the implied warranties of merchantability or fitness for a particular purpose. Emulex Co rpo ration may make improvements and ch ang es t o t he pr odu ct des cribed in this manual at any tim e and w ith out an y n ot ice. Emulex Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties that may result. Periodic changes are made to information contained herein; althou gh thes e chang e s will be incorporated into new editions of this manual, Emulex Corporation disclaims any undertaking to give notice of such changes.
LP11000 Hardware Installation Manual Page ii
Page 3
Table of Contents
Introduction ................. .............................................. ............................................. ......................................1
Major Features ...............................................................................................................................1
Compatibility ...................................................................................................................................2
Prerequisites ............... .................... ................... ............. ................... .................... .........................2
Setting the Jumpers .....................................................................................................................................3
Installing the Host Bus Adapter ...................................... ....... ...... ...... ..........................................................4
Attaching Media ...........................................................................................................................................5
Applying Power ............................................................................................................................................6
Viewing the LEDs . ...... ....... ...... ....... ...... ....... ...................................... ....... ...... ....... ...... ...................6
POST Conditions and Results ........................................................................................................6
References ..................................................................................................................................................7
Specifications .................................................................................................................................7
FCC and Regulatory Notices ..........................................................................................................8
Declaration of Conformity ...............................................................................................................9
Laser Safety Notice ......................................................................................................................11
LP11000 Hardware Installation Manual Page iii
Page 4
Introduction
The Emulex® LP11000 host bus adapter (HBA) is a single-channel, 4-gigabit per second (Gb/s), Fibre Channel (FC) PCI-X 2.0 HBA. The core technology of th is HB A is Emu lex ’s seventh generation F C controller. The controller incorporates a multi-function native PCI-X 2.0 core that i s compli ant to the Peripheral Component Interconnect (PCI) and PCI-X lo cal bus s pec ifications . T he HBA supp orts burst data transfers up to 266-megahertz (MHz) PCI-X Mode 2, 133 MHz PCI-X Mode 1, or 66 MHz PCI. The fully featured FC port is compliant to various American National Stan dard s In sti tut e (ANSI) FC standards. The product is targeted at FC storage networking environ ments that requ ire the hig hest de gree s of robustness, performance and ease of managem ent.
Major Features
Multi-function PCI-X device with one FC p ort
Auto-negotiation between 1-Gb, 2-Gb or 4-Gb link attachments
High performance FC HBA with the PCI-X 2.0 F C contr oller wi th one intern al pr ocesso r
Complies with the PCI-X 2.0a and PCI 3.0 speci fica tions for 3.3-V add-in c ards
Full support for all FC topologies i ncl uding p oint-to-p oint, ar bitrated l oop and fa bric
Full support for FC service class 2 and 3
Maximum FC throughput achieved via full duple x hardwar e sup port
End-to-end data path-parity and cyclical redundancy check (CRC) protection, including internal data path random-access memory (RAM)
Architectural support for multiple upper lay er protoc ols
State-of-the-art circuitry:
Al l PCI-X and FC func tion ality is contained withi n a s ingle , cus tom, hig h-de nsi ty, fully integrated FC controller
Inter nal A RM 1136J-S processor with instruction and data cache
Inter nal serializer deserializer (SerDes) 1-Gb/2-Gb/4-Gb core
Internal high-speed static RAM (SRAM)
Error correcting code (ECC) protection of local mem ory, including single-bit correction and double-bit protection
The LP11000 HBA provides an embedded short wave optical (LC) connection with link diagnostics capability.
Host interface via Emulex standard drivers o r through c usto m dri vers written to the Emulex Service Level Interface (SLI-2) that is compatible with the man y ex isti ng Em ulex dri vers for products such as LP8000, LP9002L, LP9802 and LP10000 HBAs
Comprehensive array of operating sy stem (OS) drivers:
Emu lex s tandard and OEM derivati ves of devic e driver s fo r Windows 2000 S erver, Win­dows Server 2003, Novell NetWare, Sun Solaris, Linux and HP-UX
OEM- specific dr ive rs for A IX and some o ther o perating s yst ems
Som e drivers s uppor t both SC SI and IP protocol s
Supp ort for remote and fabric bo ot functi onali ty
On-board context management by the firmware:
Up to 510 F C port log ins
Up to 2047 conc ur rent exch anges
LP11000 Hardware Installation Manual Page 1
Page 5
I/O m ultip lexi ng down to the FC frame lev el
Data buffers are capable of supporting 64+ buffer-to-buffer (BB) credits for short-wave applications
Link management and recovery are handled by the fir mware
On-board diagnostic capability is acces sib le vi a opti onal c onnection
Parts and construction are compliant to the Europea n Union Di rectiv e of Res triction of Hazardous Substances (RoHS)
Compatibility
Table 1. Software and Hardware Environments
Software Environments Windows 2000 Server, Windows Serv er 200 3, Novell
NetWare, Sun Solaris, Linux an d HP-U X
Hardware Environments PCI and PCI-X Mode 1 and 2 compl ia nt syste ms
Prerequisites
PCI 32/64-bit data and 33/66-MHz clock frequency, 3.3-V signaling
PCI-X Mode 1 64-bit data and 66/100/133-MHz clock frequen cy
PCI-X Mode 2 64-bit data and 266-MHz (133-MHz clock frequenc y, double data rate)
3.3-V and 5-V PCI power required for operation
LP11000 Hardware Installation Manual Page 2
Page 6
Setting the Jumpers
Caution: Emulex LightPulse® HBAs contain electronic components that can be damaged by static
electricity through an ele ct ros tatic disc har ge (ES D) eve nt. To prevent ESD damage, maintain constant contact with any grou nde d metal surface. A grounding wrist st ra p is us ef ul fo r this purpose. Handle the car d ca refu lly at al l tim es and pr efer abl y by th e edg es. Avoid to uch in g electronic componen ts and kee p th e card in the ori ginal packagin g un ti l you are rea dy fo r installation.
The device ID jumpers are used in custom appl ic ations . Do not change the jumper settings for a standard Emulex installation.
The HBA has one six-post jumper bloc k tha t contr ols the HBA 's dev ic e ID. The ID is s elec ted by installing a jumper between posts 1 and 2, or 3 and 4, or 5 and 6. If no jum per i s installed, the ho st bus adapter reports a device ID of 1AE5.
T a ble 2: Jumper Settings (Port 0)
PCI Identifier P0_JX
FD00 1–2 FD01 3–4
1AE5* 5–6
Note: * Without a jumper, the HBA reports a device ID of 1AE5. Most software drivers
require a PCI device ID of FD00 t o pr ope rly ide nt if y and cont ro l th e HBA . Do not attempt to oper ate the HBA with the PCI de vice ID set to 1AE5 u nless reco mmen ded by the driver installation inst ruct io ns.
Figure 1: The LP11000 HBA Jumper Settings
LP11000 Hardware Installation Manual Page 3
Page 7
Installing the Host Bus Adapter
To install the HBA:
1. Each HBA is shipped with a unique 64-bi t identi fier cal led the IEEE addr ess. T he FC industry uses a World Wide Name (WWN) derived from the IEEE address, and this number is needed for FC connectivity. The IEEE address is used when configuring your system . The ser ial n umber is used when communicating with Emulex. A ll nu mber s are cl ear ly m arked on the boar d. We recommend that you record these numbers befor e installation.
2. Turn off and unplug the computer.
3. Remove the computer case.
Note: For best I/O performance, pla ce th e ada pt er int o an emp ty PCI- X slot tha t is ru nning
at 133 MHz. Ensure that the PCI bus is n ot shared with another PCI card that can lower the PCI slot clock rate.
4. Remove the blank panel from an empty PCI or PCI-X bus slot. Follow steps 5 bracket if they are different sizes. Otherwise, skip to step 9.
Note: The HBA comes with a standard PCI br ack et install ed . A low -p rofi le br ac ket is
included in the box with the HBA. The low-profile mounting bracket is shorter than the standard bracket; approximately 3.11 in. (7.9 cm) compared to 4.75 in. (12.06 cm) long.
5. Remove the mounting bracket screws from the top of the HBA.
Figure 2: Removing the Bracket
6. Remove the bracket and store it for future use.
7. Align the new mounting bracket tabs with the holes in the HBA.
8 to change the
Note: Be careful not to push the bracket past the transceiver housing's grounding tabs.
Make sure the light emit ti ng diodes (L E Ds ) are pr oper ly al ig ned with t he ho le s in the bracket.
8. Replace the screws that attach the HBA to the bracket.
9. Insert the HBA into the empty 32- or 64-bit PCI or PCI-X bus slot. Press firmly until the adapter is seated.
10. Secure the HBA's mounting bracket to the case with the panel screw or clip.
11. Replace the computer case and tighten case screws. The HBA is now installed in the PC and is ready for medi a attachment.
LP11000 Hardware Installation Manual Page 4
Page 8
Attaching Media
Note: The HBA will not allow norma l da ta transmi ssi on on an optic al li nk un les s it is
connected to anothe r si mila r or compat ib le laser pr oduct (th at is , mult imod e to multimode.)
Use multimode fiber optic cable, with short-wave l ase rs , that adheres to the foll owing spec ific ations :
Table 3: Media Specifications
Fiber Optic Cable Maximum Length Minimum Length Connector
62.5/125 µm (multimode) 200 MHz*km bandwidth cable
50/125
µm (multimode)
500 MHz*km bandwidth cable
300 meters at 1.0625 Gb/s 150 meters at 2.125 Gb/s 70 meters at 4.25 Gb/s
500 meters at 1.0625 Gb/s 300 meters at 2.125 Gb/s 150 meters at 4.25 Gb/s
.5 meters LC
.5 meters LC
To attach media to the HBA:
1. Connect the fiber optic cable to the LC connector on the HBA.
Figure 3: Connecting Fiber Optic Cable
2. Connect the other end of the cable to the Fibre Channel device.
After the media is connected to the HBA, you are ready to apply power to the computer.
LP11000 Hardware Installation Manual Page 5
Page 9
Applying Power
To apply power:
1. Verify that the HBA is securely installed in th e comp uter.
2. Verify that the correct media is attached.
3. Plug in and turn on the computer.
4. Observe LEDs for Power On Self Test (POST) results.
Viewing the LEDs
Green and yellow LEDs can be seen through openings in th e HBA's mounting br ack et. Green i ndicates firmware operation and yellow signifies port activ ity. Each port has a corresponding set of green and yellow LEDs.
Figure 4: LEDs
POST Conditions and Results
POST conditions and results are summa rized i n the foll owing table:
Table 4: POST Conditions and Results
Yellow LED Green LED State
Off Off Wake-up failure (Dead board) On Off POST failure (Dead bo ar d) Slow Blink Off Wake-up failure monitor Fast Blink Off POST failure Flashing Off POST processing in progress Off On Failure while funct io ning On On Failure while functio ni ng 1 Blink On 1Gb Link rate -Nor mal , link up 2 Blinks On 2Gb Link rate -Normal, link up 3 Blinks On 4Gb Link rate -Normal, link up Off Slow Blink Normal -link down or not s tarted Slow Blink Slow Blink Off-line for dow nlo ad Fast Blink Slow Blink Restricted off-l ine mode (Waiting fo r re start) Flashing Slow Blink Restricted off-line mode (Test active)
LP11000 Hardware Installation Manual Page 6
Page 10
References
Specifications
T able 5: LP11000 Specifications
Parameter Range
Media Interface The controller in te rfaces to the physical medi a th ro ugh an FC- 0 Med ia I nt erfa ce
(FC-PI compliant tr an sceiv er) , an d then co nne cts thr ough du al opti cal fib er LC connectors.
Physical Di mensions Low-profile MD2 form fac to r, 6.600 inches by 2.53 6 inches, and acco mmodat es
both the full-heigh t an d low -pr of il e brack et .
Power Requir eme nts In a PCI/PCI-X, Mode 1, 66-MHz host:
• 1.0 watts (typical) @ +3.3 VDC
• 3.1 watts (typical) @ +5.0 VDC
• 4.5 watts (total typical) In a PCI-X, Mode 1, 100/1 33 -MHz host :
• 1.0 watts (typical) @ +3.3 VDC
• 3.3 watts (typical) @ +5.0 VDC
• 4.7 watts (total typical)
In a PCI-X, Mode 2, 133- MHz host :
• 1.0 watts (typical) @ +3.3 VDC
• 3.6 watts (typical) @ +5.0 VDC
• 5.3 watts (total typical)
Airflow 100 lf/min (minimum) Temperature 32° to 113° F (0° to 45° C), Operating
-40° to 158° F (-40° to 70° C), Storage
Humidity 5% to 95% non-conden sin g Agency Approvals for
LP11000
Class 1 Laser Product per DHHS 21CFR (J) & EN60825-1 UL recognized to UL6095 0- 1: 2003 CUR recognized to CSA 22.2, No. 60950-1-03 Baurt-certified by TUV to 60950-1 FCC Rules, Part 15, Class A Industry Canada, ICES-003, Class A EMC Directiv es 89/336/EEC and 2004/108/ EC (CE Mark) EN55022, Class A EN55024 Australian EMC Framework (C-Tick Mark) AS/NZS CISPR22:20 02 Cla ss A Japan VCCI, Class A Taiwan BSMI, Class A Korea MIC, Class A
LP11000 Hardware Installation Manual Page 7
Page 11
FCC and Regulatory Notices
LP11000 Models
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful i nterf erence, and (2) this devi ce m ust ac cep t any i nterfe rence received, including interference that m ay c ause undes ire d operation.
Responsible Party: Paul Folino, Chief Ex ecut iv e Officer Emulex Corporation (714) 662-5600 3333 Susan St. Costa Mesa, CA. 92626 USA
Note:This equipment has been tested and found to com ply wi th the li mits for a Class A di gital devic e, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment i s operated in a commer cial env ir onmen t. This equipment generates, uses, and can radiate radio fr equenc y en ergy and, i f not ins talled and us ed in accordance with the instruction man ual, may cause harmful interference to radio communi cati ons. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at hi s own expens e. T he reader is c autio ned that changes or modifications made to the equipment not expr es sly approve d by Em ule x co uld void the user's authority to operate this equipment. T he above statement appl ies to pro ducts marketed in the USA.
This class A digital apparatus meets all requirements of the Industry Canada (IC) Interference - Causing Equipment Standard (ICES-003).
Cet appareil numerique de la Classe A respecte tout es le s exigenc es du re glemen t sur le materiel brouilleur du Canada. This statement applies to products marketed in Cana da.
Notice for Japan and Translations (VCCI) Product Label
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measu res. VCCI—A
Manual Notice
Translation: This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic envi ronment, r adio disturbance may arise. When suc h trouble o cc urs, the us er m ay be requi red to take correc tive actio ns.
LP11000 Hardware Installation Manual Page 8
Page 12
Notice for Taiwan and Translations (BSMI)
Translation: This equipment is a Class A ITE, and oper atio n of this equip ment in a res idential area is likely to cause
harmful interference, in which cas e use rs will b e req uir ed to c orrect the interference at their own expense.
Notice for South Korea and Translations (MIC)
Translation: Class A Equipment: Please note that this equipme nt has b een approv ed for business pur poses with
regards to electromagnetic interference. If purchased in error for use in a residential area, you may wish to exchange the equipment where you purchased i t.
Declaration of Conformity
LP11000 HBA
This equipment complies with CIS PR22/EN 55022 Class A.
WARNING: This is a class A product. In a domestic environmen t, thi s pr odu ct may c aus e radio
interference req uirin g th e use r to take ade qu at e meas ur es.
Note: Changes or modifications not expr es sly appr ove d by Emule x Co rpor at ion cou ld void
the user's authority to oper ate t his equi pme nt.
LP11000 Hardware Installation Manual Page 9
Page 13
LP11000 Hardware Installation Manual Page 10
Page 14
Laser Safety Notice
This laser safety information contains ce rtificati on and p rodu ct in forma tion c overing las er produc ts known as optical small form fact or trans ceiver s in corpor ated i n Emul ex L ightPulse host adapters. The small form factor transceiver is the primary cable connection mechanism for any optical port on the host adapter. This data is not intended to be a replacement for any safety regulations and standards; relevant safety documents should always be consul ted if necess ar y. Contact Emulex Corporation with any questions or concerns about laser safety.
Certification and Classification
The LP11000, LP110 02 and LP 1150 host adapters may contain a laser product known as a sma ll for m factor transceiver. This transceiver provides the physical connection to the optical cable, and its LC-style connector extends through the mounting bracket. In turn, the host adapter can be inserted into any host system's appropriate PCI/PCI-X expansion sl ot.
In the United States, all optical small form factor transceivers sold by Emulex are certified as Class 1 laser products that conform to the requirements contained in the Department of Heal th and Huma n Services (DHHS) regulation 21 CFR subchapter J. The certification is indicated by a label located on the optical small form factor transceiver.
In Europe, all optical small form factor tr anscei vers s old b y Em ulex are certified as Class 1 laser component assemblies that conform to the requi rements contained in the CE NELE C (Europ ean Committee for Electrotechnical Standardization) standard EN60825-1:1994 (including amendment 11) and EN60825-2:1994. Small form factor transc eiv ers ar e certifi ed by a recogni zed E uro pean test ing agency and have appropriate markings on the assembly. The DHHS conformity label and European conformity mark will not be visible exter nall y once the opti cal small form factor transceiver is connected to or inserted in the host adapter and the adapter is installed into a system.
Labeling Requirements
No caution or danger labels are required for use of the small form factor transceiver since they are Class 1 laser component assembly. In the U.S., the only laser safety label required is the DHHS certification label that already appears on the small form factor tr ansceiv er. In Europe, the EN60825-1/EN60825-2 standards require that the system-level product has a Class 1 in forma tion l abel pe rman ently attached and clearly visible whenever access to the GLM, GBIC, 1x9 and small form factor transceiver optical port is possible. Each Class 1 product sh all have affixed an explanatory label bearing the word s:
LP11000 Hardware Installation Manual Page 11
Page 15
Alternatively, at the discretion of the manufacturer, the same statement may be included in user information. If a label is used, an example of the IEC Cl ass 1 infor mati on labe l that i s su itable for most European countries is shown below. The label consists of black printing on a white backgro und. Languages represented on this label are En glis h, Germ an, F innish and Frenc h, and they represent the minimum set for acceptance of a Class 1 product in most E uropean c ountr ies.
Product Information
Small Form Factor Transceiver
The small form factor transceiver is an integrated duplex data link for bi-directional communications over multimode or single mode optical fiber. Each small form factor transceiver cons is ts of a transmitter and receiver optical subassembly. The transmitter subassembly contains a semicon ductor las er emitti ng in the wavelength range of 770 to 860 nanometers for shortwave length small form factor transceivers and 1270 to 1355 nanometers for long wavelength small form factor tran sc eivers . For non -OFC link s, the optical power from the laser transmitter is c ontrolled and maintained at a lower power level. The power emitted from either an open fiber or open laser transmi tter is gua rante ed to be below the Cla ss 1 lim it. Class 1 laser products are not considered haza rdou s. No us er mainten ance, s er vice oper atio ns or adjustments can be performed the small form factor tran sc eiver.
Usage Restrictions
Failure to comply with these usage restrictions may result in incorrect operation of the system and could possible lead to points of access that may emit laser radiation levels above the Class 1 limits established in the U. S. by the DHHS and within Europe by EN60825-1/EN60825-2.
Short wavelength and long wavelength small form factor transceivers allow normal data transmission on the optical link when they are connected to another compatible laser product. Short wavelength and long wavelength small form factor transceiv ers embe dded in Emul ex ho st adap ter are non -O FC. For non­OFC links, a compatible laser device mu st be no n-OF C and ce rtified as a Clas s 1 l aser pr oduc t.
Any system level product that incorporates the small form factor transceivers must provide power supply protection that guarantees a voltage of 5.0 volts or less at the smal l form factor transceivers. The functional power supply range of the small for m fac tor trans cei vers produc t is spec ified as 3.135 to
3.465V typically. Operation outside of this range may degrade the performance and lifetime of the transceiver. The transceiver will remain operational with laser emis si ons b elow Cla ss 1 lim its provi ded the power supply level at the adapter remains at or below 5.0 volts. If the power supply level rises above
5.0 volts, the small form factor transceiver cannot be guaranteed to operate correctly and could result in laser emissions that m a y exceed Class 1 limits.
System Level Certification
All host adapters containing embedded small form factor tra nsc eivers are cer tifi ed as Cl ass 1 las er products within the U.S. and Class 1 laser com ponent as sem blie s outside of th e U.S. Manu facturer s of products properly incorporating the small form factor transceiver do not need to recertify their product for laser safety. The procedure for full system certification is therefore identical to that used for any o ther electronic system. When applying for sy stem l evel cert ificati on to ele ctronic standards such as IEC950, the regulatory engineers may want to see the DHHS and European conformity labeling on the small form
LP11000 Hardware Installation Manual Page 12
Page 16
factor transceiver, and the system level documentation and labeling. Copies of the cer tific ate of conformity for any small form factor trans cei ver sol d by E mulex c an be obtained upo n req uest from Emulex Corporation, Costa Mesa.
LP11000 Hardware Installation Manual Page 13
Loading...