Emtek EMTouch Installation & Programming Manual

Page 1
ASSA ABLOY, the global leader in door opening solutions
Installation & Programming Guide
EMTouch™ Electronic Lever Locksets
Page 2
2
ITEM NO. DESCRIPTION QTY.
1 Key 2
2 Outside Trim Plate Assembly 1
3 Adjustable Latch for 2 ⁄” or 2 ¾” Backset 1
4 Inside Trim Plate Assembly 1
5 #8-32 x 1½" Flat Head Machine Screw 2
6 #8 x ¾" Wood Screw 4
7 Strike Plate 1 8 Plastic Extender 1
9 Plastic Latch Pin 1
3
4b
2
4a
4c
4d
5
7
6
4
8
9
1
6
What’s in the Box
Page 3
3
1” Deep, 1” Diameter Edge Bore
2 ⁄” or 2 ¾” Backset
2 ⁄” Diameter Bore
⁄” Deep
2 ¼”
1 “
1” Diameter Edge Bore
3. Remove Screws from Inside Trim Plate
2. Door Prep
3. Door Jamb Prep
1. Conrm Handing
HANDING OF DOOR IS ALWAYS DETERMINED FROM THE OUTSIDE
Hinge is on the left.
Door is Left Hand (LH).
Hinge is on the right.
Door is Right Hand (RH).
Hinge is on the right.
Door is Right Hand (RH).
Hinge is on the left.
Door is Left Hand (LH).
In-Swing Doors
Out-Swing Doors
outsideoutside
Preparation
⁄” Deep
1-1/8"
2-3/4"
2 ¼”
1 ½”
Fasten Strike Plate using two #8 x ¾” Wood Screws (item #6).
4. Install Strike Plate
Page 4
4
Use a Phillips head screwdriver to remove screws (item #4c) shown below and detach Inside Trim Plate from the Inside Chassis.
Fasten Adjustable Latch using two #8 x ¾” Wood Screws (item #6).
2. Remove Screws from Inside Trim Plate
How to Install
!
!
REMOVE INSIDE CHASSIS FROM TRIM PLATE BEFORE INSTALLING THE OUTSIDE TRIM. THUMBTURN MUST BE IN NEUTRAL POSITION.
To remove Pin: Push Plastic Latch Pin (item #9) through latch with screwdriver.
The Adjustable Latch is factory shipped with a 2¾” backset position. Remove pin and slide spindle hub forward for a 23/8” backset, then reinsert the pin in the hole at the back of the latch as shown.
1. Install Adjustable Latch
LH RH
See Page 3 for Handing Information.
Scan QR code for
installation video
Plastic Latch Pin
Plastic
Latch
Pin
Page 5
5
3. Install Outside Trim Plate Assembly
Step 1: While holding Outside Trim Plate Assembly, Press the Plastic Extender (A) into end of Spindle Shaft (B). The Shaft is properly aligned when the marking ‘TOP’ can be seen from an overhead view.
Step 2: Position the Outside Trim Plate Assembly through the bore hole.
Step 3: With the Outside Trim Plate Assembly ush to the door, REMOVE the Plastic
Extender.
Feed wire harness through the bore hole.
B
!
A
Fit Plastic Extender through latch.
ONCE POSITIONED, OUTSIDE TRIM PLATE ASSEMBLY REQUIRES SUPPORT.
THIS SIDE ON TOP.
!
Page 6
6
4. Install Inside Chassis
CAM LINK MUST REMAIN IN THE CORRECT POSITION DURING INSTALLATION.
!
Step 1: Conrm the position of Cam Link.
For Left Hand Locks:
Turn to left position.
For Right Hand Locks:
Turn to right position.
Step 2: Feed the Wire Harness through Inside Chassis.
Page 7
7
CHECK ALIGNMENT BEFORE FULLY TIGHTENING SCREWS.
!
Step 4: Connect Wire Harness (A) and tuck Connectors as shown (B).
A
B
Step 5: Install Battery.
For optimal performance, always use a good quality battery.
9V Battery
Step 3: Fasten Inside Chassis using two #8-32 x 1½” Flat Head Machine Screw (item #5).
Page 8
8
5. Install Inside Trim Plate
Screws (item #4c)
Fasten Inside Trim Plate using two #8-32 x ⁄” Flat Head Machine Screws (item #4c).
*Neutral position is required for installation and removal of the Inside Trim Plate Assembly.
(Does not apply to Keypad Storeroom/Gate product)
!
USER CODES ARE LOCATED ON THE INSIDE TRIM PLATE & ON PAGE 11.
Inside
Correct position for installation.Thumbcam must be positioned as shown (Neutral Position)*
!
Scan QR code for
installation video
Page 9
9
Your Emtek lock is shipped with two 4-digit user codes and a 6-digit programming code. These codes are randomly generated at the factory.
(Turn to next page for Programming Instructions.)
To Unlock:
1. Press EMTEK key or touch
3 ngers across screen.
2. Enter 4-digit user codes.
(See sticker located on the inside
trim plate or on page 11).
3. Turn Handle.
To Lock:
1. Rotate Thumbturn from inside.
Passage feature
(Does not apply to Keypad Storeroom/Gate product)
Activate by turning the inside thumbturn to the unlocked position. This will engage the outside lever so a code is not required to enter.
Your Lock is Ready to Use
How to Use
Locked Unlocked
1
2
3
Page 10
10
In order to perform each of the following six functions, the lock must rst be placed in Programming Mode:
*If no input within 20 seconds, Yellow LED goes out, Red LED ashes and lock exits Programming Mode.
1. Press and hold EMTEK button for 3 seconds
2. Yellow LED ashes, then remains solid*, number keys also illuminate
3. Enter Programming Code
4. Yellow LED ashes, then 2 beeps
5. Yellow LED remains solid (awaiting button press; see following Table)
If you wIsh to Press
Button
ActIons IndIcAtors
Change
Programming
Code
(6 digits)
1
Enter New
Programming
Code
(6 digits)
Re-Enter
New
Programming
Code
(6 digits)
1 Green LED ash
1 beep
1 Green LED ash
1 beep
2 Green LED ashes
2 beeps
Add User Code
(4 digits)
(Store up to 20
User Codes)
2
Enter New User Code
(4 digits)
Re-Enter
New User
Code
(4 digits)
1 Green LED ash
1 beep
1 Green LED ash
1 beep
2 Green LED ashes
2 beeps
Delete User Code 3
Enter User
Code to be
Deleted
Re-Enter
User Code to
be Deleted
1 Green LED ash
1 beep
1 Green LED ash
1 beep
2 Green LED ashes
2 beeps
**
Enable/Disable
All User Codes
4
Entering ‘4’ disables all Users
(enables all if disabled)
2 Green LED ashes
2 beeps
Delete All User
Codes
5
Re-Enter Programming Code
1 Green LED ash
1 beep
2 Green LED ashes
2 beeps
Turn Beeper On/
Off
6
Entering ‘6’ turns OFF (or ON)
1 Green LED ash
1 beep
2 Green LED ashes
2 beeps
**Also referred to as “vacation mode”. This command temporarily disables all user codes (metal key override will still work).
How to Program
Programming Your Lock
Page 11
11
IN8-EMTOUCHLL 10/22/2012
Restoring the Lock to Factory Default Setting
Press and hold EMTEK button for 3 seconds.
Enter
000000
After 2 beeps and 2 Green LED Flash, remove power (disconnect 9V battery)
from Lock.
After 5 seconds, restore power (reconnect 9V battery)
Conrm by 2 beeps and 2 Green LED Flash.
This procedure clears the lock of all users and restores the Programming Code and
2 User Codes shipped with the lock.
Function Indicators
Valid Code • 1 short beep, EMTEK button ashes
Green.
Invalid Code/Access Denied* • 1 Red LED ash
2 short beeps
Lock-Out Mode Error 2 short beeps
1 short beep per second for duration
Access Accepted 1 short beep
1 Green LED ash
Low Battery 4 Red LED ashes
4 short beeps
Blackout Battery
**
• 1 long Red LED ash
• 4 long beeps
Button Press Accepted 1 Yellow LED ash
1 Short Beep
Outside Thumb Turn Enabled 2 Green LED ashes
* If 3 consecutive incorrect codes are entered, the lock emits 4 short beeps and a ashing Red EMTEK
button. The lock will not accept additional input for 20 seconds (20 beeps). When the next valid code is entered the lock will beep quickly 3 times to alert of the incorrect codes.
**
Battery voltage has dropped too low; keypad will be disabled but metal key override will still work.
Keypad Operation - Beeper & LED Indicators
Place Sticker Here
U.S. patent: 8,176,761 International patents pending.
Page 12
ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
Copyright © 2012, Emtek Products, Inc. an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Emtek Products, Inc. is prohibited.
Scan QR code for installation video
Loading...