Empire Comfort Systems ROK-1, FAW-40SPP, FAW-40IP Installation Instructions Manual

R-3159
INSTALLATION INSTRUCTIONS
REAR OUTLET, KIT NUMBER ROK-1
MODELS
FAW-40SPP AND FAW-40IP VENTED WALL FURNACES
INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installing Optional Rear Outlet Rear outlet kit, 10" boot assembly with register, ROK-1 for warm air discharge into an adjoining room.
Attention: Before furnace is attached to the wall, the wall opening for the rear outlet must be cut, in addition to removal of the outer and inner casing knockouts on furnace.
1. The wall opening measurements for the rear outlet are the fol­lowing. A. From floor to bottom of wall opening is 10 11/16". B. From bottom of wall opening to top of wall opening is 8
1/2".
C. Wall opening width is 12 1/8".
2. Scribe a line between the four dimples on the outer casing back to form a square. Drill a pilot hole within the scribed square on the outer casing back. Remove the sheet metal within the scribed square with a tin snips or comparable tool.
3. Remove the (4) #8 x 3/8" screws that attach the inner casing close off plate to the inner casing.
4. Insert the privacy shield through the outer casing back and the
inner casing back. The privacy shield will be in front of the inner casing back and behind the combustion chamber tubes. Align clearance holes on privacy shield with screw holes on inner casing back. Attach privacy shield to inner casing back with (2) #8 x 3/8" screws provided. Attention: The (2) #8 x 3/8" screws must be inserted from the front of the furnace.
5. Attach furnace to wall (refer to Installation Instructions and Owner's Manual).
6. Align clearance holes on 8" x 12" boot with screw holes on outer casing back and mark boot to be flush with wall surface. Remove boot and cut to proper length.
7. Attach 8" x 12" boot to outer casing back with (6) #8 x 3/8" screws provided.
8. Align clearance holes on 6" x 10" duct with screw holes on inner casing back and mark duct to be 2 1/4" shorter than 8" x 12" boot. Remove duct and cut to proper length.
9. Attach 6" x 10" duct to inner casing back with (4) #8 x 3/8" screws removed in Step 3, 2 on top and 2 on bottom.
10. Insert rear register into 8" x 12" boot. Attach rear register to wall with (2) #10 x 1" screws provided.
11. Installation of ROK-1 is completed.
R-3159 7/01
Page 1
R-3159
INSTALLATION INSTRUCTIONS
REAR OUTLET, KIT NUMBER ROK-1
MODELS
FAW-55SPP AND FAW-55IP VENTED WALL FURNACES
INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installing Optional Rear Outlet Rear outlet kit, 10" boot assembly with register, ROK-1 for warm air discharge into an adjoining room.
Attention: Before furnace is attached to the wall, the wall opening for the rear outlet must be cut, in addition to removal of the outer and inner casing knockouts on furnace.
Note: The privacy shield is not used on the FAW-55(SPP, IP) furnaces and can be discarded.
1. The wall opening measurements for the rear outlet are the following. A. From floor to bottom of wall opening is 14 3/4". B. From bottom of wall opening to top of wall opening is 8
1/2".
C. Wall opening width is 12 1/8".
2. Remove outer casing knockout from outer casing back.
3. Remove inner casing knockout from inner casing.
4. Attach furnace to wall (Refer to Installation Instructions and Owner's Manual).
5. Align clearance holes on 8" x 12" boot with screw holes on outer casing back and mark boot to be flush with wall surface. Remove boot and cut to proper length.
6. Attach 8" x 12" boot to outer casing back with (6) #8x 3/8" screws provided.
7. Align clearance holes on 6" x 10" duct with screw holes on inner casing and mark duct to be 2 1/4" shorter than 8" x 12" boot. Remove duct and cut to proper length.
8. Attach 6" x 10" duct to inner casing back with (4) #8x 3/8" screws provided.
9. Insert rear register into 8" x 12" boot. Attach rear register to wall with (2) #10 x 1" screws provided.
10. Installation of ROK-1 is completed.