Empire Comfort Systems R11006 Operating Instructions Manual

Premium Multifunction Remote R11006
Operation Instructions
P1
P1
CONTINUOUS
PILOT
FLAME MAIN
FLAME
REAR
U
TIME
ROOM
P
PROG
REAR
FAN
MAIN
LIGHTS
TIMER
SET
FRI
AM PM
MODE
D
O
W
SATTHUWEDTUEMONSUN
P2
P2
ON
OFF
THERMO
SET
Display Description
P1
P1
PROGRAM 1 - ON
PROGRAM 1 - OFF
COUNTDOWN TIMER
P2
P2
PROGRAM 2 - ON
PROGRAM 2 - OFF
BATTERY LOW
CONTINUOUS
PILOT
CONTINUOUS PILOT CHOICE
ROOM TEMPERATURE
ROOM
THERMOSTAT SETTING
SET
ON
OFF
DISPOSITION OF HEATER
THERMO
Button Description
MODE
MODE
U
P
UP
D
O
W
N
DOWN
FLAME MAIN
FLAME
REAR
FAN
TIMER
SET
PROG
TIME
FLAME MAIN
FAN
TIMER
SET
FLAME REAR
PROG/TIME
FAN
REAR
MAIN
REAR AND MAIN FLAME MODULATION
LIGHTS
IMPORTANT
Notice: Please retain these instructions for future reference to program and operate this remote control.
Notice: It is recommended that batteries in the hand held remote and the back up batteries (located near
the gas control compartment) be replaced on a yearly basis to ensure sufcient power require­ments.
28641-1-0512 Page 1
Initial Remote Setup
Installation of (2) AAA-size batteries will activate the setup mode. Setup mode can also be activated by pressing the FLAME REAR
and PROG/TIME buttons simultaneously for 5 seconds. The con-
trol will exit setup mode if no button is pressed for 20 seconds. Appropriate icon on LCD will ash when ready for setup.
1. Press the UP or Down button in setup mode to change the temperature scale. Press SET button to skip or advance to
Fuel Type setup.
2. To switch between the NG and LP step motor settings, press
and hold the learn button for 20 seconds. The module should emit a short beep (less than 1 second) to indicate that the
control was switched from NG (default setting) to LP. When switching back from LP to NG, the control should emit a long
beep (3 seconds).
Note: When installing or replacing batteries, the Remote Control
handset should be reset to the appropriate NG or LP icon
depending on the appliance gas type specied on the rating
plate.
3. Press the UP or Down Button to set the hour. Press SET to advance to minutes.
4. Press the UP or Down button to set minutes. Press SET to advance to AM or PM.
5. Press the UP or Down button to set AM or PM. Press the SET button to advance to the day of week.
6. Use UP or Down button to select the day of the week.
7. The control will exit setup mode in 20 seconds.
Learn Function
1. To program the system to a transmitter, press the LEARN but­ton on the Main Module. A single audible beep will be heard.
2. Press the MODE button on the transmitter to learn the trans-
mitter to the system. A series of beeps will be heard.
3. Up to two additional (NON-THERMOSTATIC) transmitters can be used simultaneously. To learn additional transmitters, press and release the learn button again, and press the on
button on the additional transmitters.
4. To clear all transmitters and start over, press and hold the LEARN button for 10 seconds. A series of three beeps will be heard, and the system is clear.
Child Lock-Out
The Child Lock-out feature can be activated by pressing the PROG/Time and UP buttons simultaneously for ve seconds. CP will appear on the LCD in the ROOM box on the screen, and no
signals can be sent from the transmitter.
To take the control out of Child Lock-out mode, repeat the above step. CP will disappear from the screen.
Thermal Safety
When the internal components of the Main Module reach 170°F, the unit will automatically shut off, and send a repetitive audible signal. The unit can be turned back on when the module cools below 160°
Communication Safety
When in the Thermostat or Program Mode, the transmitter will send a silent signal to the module every 15 minutes. If a signal is not received within 2 hours due to dead batteries, lost transmitter, or transmitter out of range, the unit will automatically shut down, and the module will send a repetitive audible signal.
Low Battery Indicator
A low battery icon will appear on LCD screen when transmitter batteries reach low voltage level. When the batteries are replaced, Initial Remote Setup, Learn Function and any programing will
need to be redone.
MODE Button
The MODE button cycles the unit through the basic operational modes.
1. When off, press and release the MODE button to turn the unit
on in Manual mode.
2. Press and release the MODE button again, and the unit will
operate in the Thermostat mode.
3. Press and release the MODE button again, and the unit will
turn off.
Program Mode
The Program function is controlled by the PROG/TIME button.
The control may be programmed for up to two settings for week­days and two settings for weekends. The control is preset to fac-
tory settings.
When the Program Mode is activated, the unit will automatically be operating in the Thermostat Mode. The unit will turn on or off
based upon room and set temperature.
To activate the Program mode, press and release the PROG/TIME
button.
1. To change the settings for the Program mode, press and hold
the PROG/TIME button for 5 seconds. The program feature
will ash at the top of the screen.
For Weekday Settings
2. Press the UP or DOWN button to change the setting of the weekday (Mon,Tues,Wed,Thurs,Fri) P1 ON. Press and re­lease the SET button.
3. Press the UP or DOWN button to change the setting of P1 OFF. Press and release the SET button.
4. Press the UP or DOWN button to change the setting of P2 ON. Press and release the SET button.
5. Press the UP or DOWN button to change the setting of P2 OFF. Press and release the SET button.
For Weekend Settings
6. Press the UP or DOWN button to change the setting of the weekend (Sat, Sun) P1 ON. Press and release the SET but­ton.
7. Press the UP or DOWN button to change the setting of P1 OFF. Press and release the SET button.
8. Press the UP or DOWN button to change the setting of P2 ON. Press and release the SET button.
9. Press the UP or DOWN button to change the setting of P2 OFF. Press and release the SET button.
10. The Program Mode has been re-programmed.
28641-1-0512Page 2
Loading...
+ 2 hidden pages