Empire Comfort Systems LS38DF-1, LS48DF-1 Installation Instructions And Owner's Manual

INSTALLATION INSTRUCTIONS
EMPIRE
EMPIRE
Comfort Systems
AND OWNER'S MANUAL
BLUE BAY
LOG SET MODELS
LS38DF-1
LS48DF-1
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WARNINGS
If the information in this manual is not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other ammable
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re de­partment.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
vapors
GAS-FIRED
Log sets comply with ANSI Z21.11.2 Unvented Heaters and also comply with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may
only allow operation of log sets in a vented conguration.
Check your state or local codes.
WARNING: If not installed, operated and maintained in ac­cordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combus­tion which can cause death or serious illness.
Page 1
IMPORTANT INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.
Logs must t rmly onto the burner when positioned as shown in
the photos. Misformed logs or logs with sloppy pin holes must be replaced.
Proper Primary Airow into Burner
For proper burner operation and ame appearance, the ow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This ow of air is reduced if dirt, lint or other
obstructions build-up around or inside the venturi. Any obstruction
in the venturi tube area must be removed. The ow of air into the venturi is also reduced if the gas orice isn’t centered in the venturi
inlet and/or is not aligned with the venturi. Any misalignment of the
burner orice may be corrected by bending the shutter cap holding the orice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns
Ceiling fans or oscillating oor type fans need to be monitored
during the operation of vent-free logs. If the air blows directly into
the ame causing it to impinge on the log set, or rebox, it should be
turned off or redirected. Ceiling fans could be reversed to possibly
eliminate ame impingement, and the oor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the ame to impinge on the log and create a sooting
situation.
WARNING: Do not allow fans to blow directly into the replace. Avoid any drafts that alter burner ame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or
other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot like substance. Burning candles while the log set is operating
magnies the problem. It should be noted that candles, in general,
produce soot. The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit
soot on the logs. If users see soot appear on a log, call for service.
Do not continue to operate the log set.
GENERAL INFORMATION
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equip-
ment shall be performed only by a qualied agency. The term "qualied agency" means any individual, rm, corporation,
or company that either in person or through a representa-
tive is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of
the authority having jurisdiction.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018.
State of Massachusetts: The installation must be made
by a licensed plumber or gas tter in the Commonwealth
of Massachusetts.
Sellers of unvented propane or natural gas-red supple­mental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
32819-0-0913Page 2
LOG IDENTIFICATION
DESCRIPTION
REAR LOG 30901 32823
RIGHT FRONT LOG 30904 30904
LEFT FRONT LOG 30902 32824
PART NUMBER
LS38DF LS48DF
LOG IMAGE
LEFT BRANCH 30903 30903
32819-0-0913 Page 3
Before you begin: Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After
handling logs, wash your hands gently with soap and water.
All Logs
Properly positioning the logs is critical to the safe and clean operation of this heater. Sooting and other problems may
result if the logs are not properly and rmly positioned in the
appliance.
WARNING
Failure to position the parts in accordance with the dia­grams and instructions below or failure to use only parts
specically approved for use with this heater may result in
property damage or personal injury.
Index Letter Description
A Rear Log 30901 32823
B Right Front Log 30904 30904
C Left Front Log 30902 32824
D Left Branch 30903 30903
E Log Plate 30437 32821
Part Number
LS38DF LS48DF
32819-0-0913Page 4
Loading...
+ 8 hidden pages