Empire Comfort Systems LS18CD-1, LS30CD-1, LS24CD-1 Installation Instructions And Owner's Manual

INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
DRIFTWOOD
LS24CD Shown
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
FIRE OR EXPLOSION HAZARD If the information in these instructions is
not followed exactly, a re or explosion
may result causing property damage, personal injury or loss of life.
LOG SET FOR UNVENTED
GAS LOG HEATER OR VENTED
DECORATIVE APPLIANCE
MODELS
LS18CD-1 LS24CD-1 LS30CD-1
GAS-FIRED
If not installed, operated and maintained in accordance with the manufacturer's instruc-
tions, this product could expose you to sub­stances in fuel or from fuel combustion which
can cause death or serious illness.
Log sets comply with ANSI Z21.11.2 Unvented Heaters and also comply with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may only allow operation of log sets in a
vented conguration. Check your state or local codes.
— Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
— Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
Please See Our Website For Log Assembly Videos.
Page 1
TABLE OF CONTENTS
Section Page
Important Installation Guidelines .................................................................................................................................. 3
General Information .....................................................................................................................................................3
Requirements for Canada ............................................................................................................................................ 4
LS(18,24,30)CD Log Sets ............................................................................................................................................ 5
Log Identication LS18CD ...........................................................................................................................................6
Log Placement LS18CD........................................................................................................................................7 - 16
Log Identication LS24CD .........................................................................................................................................17
Log Identication LS30CD .........................................................................................................................................18
Log Placement LS(24,30)CD ..............................................................................................................................19 - 30
Ember Placement LS(18,24,30)CD............................................................................................................................31
Valve Operation LS(18,24,30)CD ...............................................................................................................................32
Appliance Service History ...................................................................................................................................33 - 34
Master Parts Distributor List ....................................................................................................................................... 35
How To Order Repair Parts ........................................................................................................................................ 35
38616-0-0218Page 2
IMPORTANT INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.
Logs must t rmly onto the burner when positioned as shown in the photos. Malformed logs or logs with sloppy pin holes must be replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect. Place on the front portion of the burner only. The photos in this manual show the proper placement of rock wool.
Never place decorative lava rock or small wood pieces on the burner. Place them on the oor of the replace or rebox only.
Proper Primary Airow into Burner
For proper burner operation and ame appearance, the ow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. Air ow may be reduced if dirt, lint or other obstructions build-up around or inside the venturi. Any obstruction must be removed. Air ow into the venturi is also reduced if the gas orice isn’t centered in the venturi inlet or is not aligned with the venturi. Correct any misalignment of the burner orice by bending the shutter cap holding the orice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns
Ceiling fans or oscillating fans need to be monitored during the operation of this vent-free burner. If air blows directly into the ame causing it to impinge on the log set, or rebox, turn off or redirect the fan. Ceiling fans may be reversed to eliminate ame impingement. Upon installation, be aware of any cold-air returns or vents in the proximity of the burner. Any draft created around a vent-free burner can cause ame impingement and create soot.
WARNING
Do not allow fans to blow directly into the replace. Avoid any drafts that alter burner ame patterns.
WARNING
Do not use a blower insert, heat exchanger insert or other
accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot-like substance. Burning candles while the burner is operating magnies the problem. Candles in general produce soot. The amount of time burned and the quantity of candles will determine the amount of soot produced.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot on a log, they should call for service. Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken replace, raise the oor to ensure adequate airow and guard against sooting. Raise replace oor using a non-combustible material, which is secure.
Glass Doors
Keep glass doors open during all operations of the logset. The opening of the glass door frame should be the dimension used for the minimum front opening of the rebox.
Wood-Burning Fireplaces
The interior of the rebox and the chimney must be cleaned and free of all creosote before installing a gas log set. Creosote will soften when heated and can drop onto the logset causing odors and soot.
WARNING
Before installing in a solid-fuel burning replace, the chimney ue and rebox must be cleaned of soot, creosote, ashes and loose paint by a qualied chimney cleaner.
Initial Operation
Once the installation is complete and the logs and embers are in place, light the burner and operate it on high for a minimum of three continuous hours. This will burn off any foreign materials, such as dust or paint overspray, that might cause odors during normal operation. Open windows or doors as needed to allow odors and excess heat to escape.
GENERAL INFORMATION
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization equip­ment or accessories and repair and servicing of equipment shall be performed only by a qualied agency. The term "qualied agency" means any individual, rm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018.
38616-0-0218 Page 3
Commonwealth of Massachusetts: The installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the Commonwealth of Massachusetts, unvented propane and natural gas-red space heaters shall be prohibited in bedrooms and bathrooms.
REQUIREMENTS FOR CANADA
This unit cannot be installed in a UNVENTED application, this unit can only be installed as a VENTED application with these requirements.
IMPORTANT SAFETY INFORMATION
This unit complies with ANSI Z21.60and CGA 2.26 Decora­tive Gas Appliances For Installation In Solid Fuel Burning Fireplaces. Do not burn wood or solid fuels in a replace where a decorative gas log set is installed. This appliance is for installation only in a solid fuel burning replace, masonry replace or manufactured replace.
Warning: Any modication to this gas log set can be dan­gerous. Improper installation or use of the gas log set can cause serious injury or death from re, burns, explosion or carbon monoxide poisoning.
1. Please follow all local codes regarding installation, combustion and ventilation air or in the absence of local codes follow the National Fuel Gas Code ANSI Z223.1(U.S. installation), or CAN/CGA-B149, Installa-
tion Code (Canada installation).
2. Proper installation, burner location and log placement is important to achieve optimum look and performance of your gas log set. The logs have been designed for easy location and placement on the grate and must be followed for proper operation.
3. Do not operate the burner with glass doors in the closed position. A replace screen must be in place when the burner is burning. Adequate combustion air must be provided for proper venting. All ames should go up and out the top of the rebox into the ue vent. If any ames oat or curl forward into the room do not operate appli­ance. Check for an open ue and adequate combustion air into the room. A damper clamp must be installed on the rebox damper to maintain an open ue vent condi­tion. Refer to replace owners manual INSTALLING DAMPER CLAMP section.
4. Young children must be carefully supervised when they are in the same room as an operating vent-free burner. Do not place stockings, clothing or any ammable ma­terial above or near the replace.
5. Do not substitute or use materials other than those sup­plied for use with the log set.
6. Also refer to IMPORTANT SAFETY INFORMATION in the replace Owner's Manual.
WARNING; DO NOT OPERATE THIS GAS LOG SET WITH GLASS DOORS CLOSED
Clothing or other ammable material should not be placed on or near the appliance.
Do not place debris or other articles on the log set dur-
ing operation.
A window should be opened during the initial bake out
period.
Installation and repair should be done by a qualied service person. The appliance should be inspected before use and at least annually by a qualied service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
Do not use this appliance if any part has been under water. Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un­der water.
Never burn solid fuels in replace where a gas log set is
installed.
This unit complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may only allow operation of this appliance in a vented conguration. Check your state or local codes.
38616-0-0218Page 4
LS(18,24,30)CD - LOG SETS
LS18CD - LOG SET
38616-0-0218 Page 5
LS24CD - LOG SET
LS30CD - LOG SET
LOG IDENTIFICATION - LS18CD
PART NUMBER
& DESCRIPTION
R12544
Rear Left
(Log A)
R12545
Rear Right
(Log B)
R12546
Front Left
(Log C)
TOP VIEW FRONT VIEW
R12547
Center
(Log D)
R12548
Front Right
(Log E)
R12549
Side Left
(Log F)
R12550
Top Left
(Log G)
R12551
Side Right
(Log H)
38616-0-0218Page 6
LOG PLACEMENT LS18CD
Before you begin: Do not, handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and rmly positioned in the appliance.
Refer to Figure 1 for the following warning.
WARNING
Failure to position the parts in accordance with this diagram
or failure to use only parts specically approved with this
appliance may result in property damage or personal injury.
LS18CD
The following WARNING applies when log set is installed onto an unvented gas burner assembly.
WARNING
This appliance is equipped for natural or propane gas. Field
conversion is not permitted.
Apply glowing embers per the ember placement section of this manual on page 30. Replace glowing embers with appropriate part number from the table below from Empire Comfort Systems, Inc. Application of excess glowing embers may adversely affect perfor­mance of the heater.
WARNING
All previously applied loose material must be removed prior
to reapplication.
Replacement Loose
Material (Glowing Embers)
LS18CD 15999
Platinum Bright Embers PE-20-1
NOTE: A single layer of embers is to be used when applying Platinum Bright Embers (alone or in combination with production embers) to the burner. As you add platinum embers, remove a like amount of standard embers. The total amount of embers must not exceed the amount provided with the burner. Tear the embers into dime-size pieces and pull them open to reveal as much surface
area as possible.
Part Number
Figure 1
ATTENTION: Do not use Figure 1 to order replacement logs. Refer
to Log Identication LS18CD on Page 5 log to order logs for your
appropriate model number.
Please See Our Website For Log Assembly Videos.
38616-0-0218 Page 7
LOG PLACEMENT LS18CD (CONT'D)
1. Place Log (B) onto right rear pin on rear log support.
TOP VIEW
FRONT VIEW
38616-0-0218Page 8
LOG PLACEMENT LS18CD (CONT'D)
2. Place Log (A) onto left rear pin on rear log support.
TOP VIEW
38616-0-0218 Page 9
FRONT VIEW
LOG PLACEMENT LS18CD (CONT'D)
3. Place Log (C) onto two (2) left front pins on burner pan.
TOP VIEW
FRONT VIEW
38616-0-0218Page 10
LOG PLACEMENT LS18CD (CONT'D)
4. Place the "T" shaped end of Log (D) onto the recess on Log (B), matching and covering the red dots and the other end of Log (D) onto the recess on Log (C) matching and covering the red dots.
TOP VIEW
38616-0-0218 Page 11
FRONT VIEW
Loading...