INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
The White Mountain Log Collection
LOG SET FOR UNVENTED
GAS LOG HEATER
OR
VENTED DECORATIVE APPLIANCE
MODELS
LS-18P-1
LS-24P-1
LS-30P-1
EFFECTIVE DATE
JANUARY 2007
WARNING: If the information in these instructions are not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
Log sets comply with ANSI Z21.11.2 Unvented
Heaters and also comply with ANSI Z21.60
Decorative Vented Appliances for Solid Fuel
Burning Fireplaces. State or local codes may only
allow operation of log sets in a vented configuration.
Check your state or local codes.
WARNING: If not installed, operated and maintained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
Page 120176-3-0107
TABLE OF CONTENTS
Section Page
Important Installation Guidelines ......................................................................... 3
General Information ............................................................................................. 3
Log Placement ...................................................................................................4-6
LS-18P-1 Photos ..................................................................................................7
LS-24P-1 Photos ..................................................................................................8
LS-30P-1 Photos ..................................................................................................9
Parts List & Parts View ...................................................................................... 10
How to Order Repair Parts ................................................................................. 11
Notes .................................................................................................................. 11
Page 2 20176-3-0107
IMPORTANT INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs
must be correctly positioned onto the burner. The photos in this
manual show the proper pinned position for logs on this set.
Owners need to be shown proper log placement and instructed
not to move the logs.
Logs must fit firmly onto the burner when positioned as shown
in the photos. Malformed logs or logs with sloppy pin holes must
be replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect.
It must be positioned only on the front portion of the burner. The
photos in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed
on the burner. These items are only for placement on the floor of
the fireplace or firebox.
Proper Primary Airflow into Burner
For proper burner operation and flame appearance, the flow of
primary air into the venturi tube, located on the rear of the burner,
must not be reduced. This flow of air is reduced if dirt, lint or other
obstructions build-up around or inside the venturi. Any obstruction
in the venturi tube area must be removed. The flow of air into the
venturi is also reduced if the gas orifice isn’t centered in the venturi
inlet and/or is not aligned with the venturi. Any misalignment of
the burner orifice may be corrected by bending the shutter cap
holding the orifice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
Ceiling fans or oscillating floor type fans need to be monitored
during the operation of vent-free logs. If the air blows directly
into the flame causing it to impinge on the log set, or firebox, it
should be turned off or redirected. Ceiling fans could be reversed
to possibly eliminate flame impingement, and the floor fan could
be redirected. Upon installation, be aware of any cold air returns
or vents in the proximity of the log set. Any draft created around
a vent-free log set can cause the flame to impinge on the log and
create a sooting situation.
WARNING: Do not allow fans to blow directly into the fireplace.
Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or
other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set
is in operation. Candles produce a residue in the air that creates a
soot like substance. Burning candles while the log set is operating
magnifies the problem. It should be noted that candles, in general,
produce soot. The amount of time burned and the quantity of
candles burned will determine the amount of soot produced and
deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit
soot on the logs. If users see soot appear on a log, call for service.
Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken fireplace, you must raise the floor
to insure adequate airflow and guard against sooting. Raise fireplace
floor using a non-combustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the
logset. The opening of the glass door frame should be the dimension
used for the minimum front opening of the firebox.
Woodburning Fireplaces
The interior of the firebox and the chimney should be cleaned and
free of all creosote before installing a gas burning log set. Creosote
will soften when heated and can drop on the logset causing odors
and possibly sooting.
WARNING: Before installing in a solid-fuel burning fireplace,
the chimney flue and firebox must be cleaned of soot, creosote,
ashes and loose paint by a qualified chimney cleaner.
GENERAL INFORMATION
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip
ment or accessories and repair and servicing of equipment shall
be performed only by a qualified agency. The term "qualified
agency" means any individual, firm, corporation, or company
that either in person or through a representative is engaged in and
is responsible for (a) the installation, testing, or replacement of
gas piping or (b) the connection, installation, testing, repair, or
servicing of equipment; that is experienced in such work; that is
familiar with all precautions required, and that has complied with
all the requirements of the authority having jurisdiction.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54
*Available from the American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10018.
.*
-
State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and
natural gas-fired space heaters shall be prohibited in
bedrooms and bathrooms.
Page 320176-3-0107
LOG PLACEMENT
Before you begin: Do not, handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs,
wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are
not properly and firmly positioned in the appliance.
Refer to Figure 1 for the following warning.
Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
PROPER INSTALLATION SEQUENCE:
LS-(18, 24, 30)P
(Figures 1 to 5)
1. Place front left (A) log onto burner pan pins.
2. Place rear left (B) log between rear log support and front left log (A)
3. Place rear right (C) log between rear log support and burner pan, resting on right side of burner pan.
4. Place right front (D) log onto pins on burner pan.
Figure 1
5. Place rear center (E) log onto left pin of rear log support.
6. Place boss on middle left (F) log into recess on rear left (B) log and left front (A) log.
7. Place middle right (G) log onto the right pin of rear log support and resting on rear right (C) log.
Page 4 20176-3-0107