Empire Comfort Systems LS-16C-2, LS-30C2-1, LS-18C2S-1, LS-30C2S-1, LS-18C2-1 User Manual

...
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
The White Mountain Log Collection
LOG SET FOR UNVENTED
GAS LOG HEATER
OR
VENTED DECORATIVE APPLIANCE
MODELS
WARNING: If the information in these in­structions are not followed exactly, a fire or explosion may result causing property dam­age, personal injury or loss of life.
— Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup­plier’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
CHARRED
OAK
CHARRED OAK
SUPER SIZE
LS-16C-2 LS-18C2-1 LS-18C2S-1 LS-24C2-1 LS-24C2S-1 LS-30C2-1 LS-30C2S-1
EFFECTIVE DATE
OCTOBER 2006
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
Log sets comply with ANSI Z21.11.2 Unvented Heaters and also comply with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may only allow operation of log sets in a vented configuration. Check your state or local codes.
Page 120172-3-1006
TABLE OF CONTENTS
Section Page
Important Installation Guidelines ..................................................................................3
General Information ......................................................................................................4
Charred Oak Log Placement .........................................................................................5
Ember Placement LS-16C-2 Photos .............................................................................6
Ember Placement LS-18C2-1 Photos ...........................................................................7
Ember Placement LS-24C2-1 Photos ...........................................................................8
Ember Placement LS-30C2-1 Photos ...........................................................................9
Charred Oak Super Size Log Placement .....................................................................10
Ember Placement LS-18C2S Photos ...........................................................................11
Ember Placement LS-24C2S Photos ...........................................................................12
Ember Placement LS-30C2S Photos ...........................................................................13
Charred Oak Parts List and Parts View .......................................................................
Charred Oak Super Size Parts List and Parts View .....................................................
14 15
How to Order Repair Parts ..........................................................................................15
Page 2 20172-3-1006
IMPORTANT INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.
Logs must fit firmly onto the burner when positioned as shown in the photos. Malformed logs or logs with sloppy pin holes must be replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect. It must be positioned only on the front portion of the burner. The photos in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed on the burner. These items are only for placement on the floor of the fireplace or firebox.
Proper Primary Airflow into Burner
For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructions build-up around or inside the venturi. Any obstruction in the venturi tube area must be removed. The flow of air into the venturi is also reduced if the gas orifice isn’t centered in the venturi inlet and/or is not aligned with the venturi. Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns
Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent-free logs. If the air blows directly into the flame causing it to impinge on the log set, or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the flame to impinge on the log and create a sooting situation.
WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot like substance. Burning candles while the log set is operating magnifies the problem. It should be noted that candles, in general, produce soot. The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken fireplace, you must raise the floor to insure adequate airflow and guard against sooting. Raise fireplace floor using a non-combustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the log set. The opening of the glass door frame should be the dimension used for the minimum front opening of the firebox.
Woodburning Fireplaces
The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas burning log set. Creosote will soften when heated and can drop on the log set causing odors and possibly sooting.
WARNING: Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.
Page 320172-3-1006
GENERAL INFORMATION
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip­ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10018.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas­sachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.
Page 4 20172-3-1006
1
2
3
4
CHARRED OAK LOG PLACEMENT
Before you begin: Do not, handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance.
Refer to Figure 1 and Figure 1A for the following warning.
Warning: Failure to position the parts in accordance with
this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
PROPER INSTALLATION SEQUENCE: LS-(18,24,30)C2-1: (Figure 1)
1. Place rear (#1) log onto two (2) pins on rear log support.
2. Place left, front (#2) log onto two (2) left, front pins on burner
3. Place right, front (#3) log onto two (2) right, front pins on
4. Place Y Branch (#4) onto two (2) pins on rear log.
5. Compare the completed log installation with the appropriate
6. Log placement is completed.
PROPER INSTALLATION SEQUENCE: LS-16C-2 (Figure 1A)
1. Place rear (#4) log onto right, rear pin on rear log support.
2. Place middle (#1) log between rear log support and burner
3. Place left, front (#2) log onto two (2) left, front pins on burner
4. Place right, front (#3) log onto two (2) right, front pins on
5. Compare the completed log installation with the appropriate
6. Log placement is complete.
pan.
burner pan.
photo from pages 7 through 9. Review previous steps to make any necessary adjustments.
pan.
pan.
burner pan.
photo from page 6. Review previous steps to make any necessary adjustments.
Re p laceme nt Loose Ma terial (g lowing em bers) Pa r t Number
LS-16C and CHBR 15998
LS-18C 15999
LS-24C 15970
LS-30C 15970
Platinum Bright Embers PE-20-1
Note: A single layer of embers is to be used when applying Platinum Bright Embers (alone or in combination with production embers) to the burner.
Log Placement LS-(18,24,30)C2-1
Figure 1
Attention: Do not use Figure 1 or Figure 1A to order replacement
logs. Refer to Page 14 Parts List and Parts View to order logs for your appropriate model number.
Apply loose material (glowing embers) per appropriate Installation Instructions and Owner's Manual. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater.
WARNING: All previously applied loose material must be removed prior to reapplication.
Log Placement LS-16C-2 and CHBR
Figure 1A
The following WARNING applies when log set is installed onto an unvented gas burner assembly.
WARNING: This appliance is equipped for (natural or propane) gas. Field conversion is not permitted.
Page 520172-3-1006
Loading...