INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
The White Mountain Log Collection
LOG SET FOR UNVENTED
GAS LOG HEATER
OR
VENTED DECORATIVE APPLIANCE
MODELS
LS-18H-1
LS-24H-1
LS-30H-1
EFFECTIVE DATE
MAY 2006
WARNINGS
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or
loss of life.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
– Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with
the appliance.
CONSUMER: Retain this manual for
future reference.
Log sets comply with ANSI Z21.11.2 Unvented
Heaters and also comply with ANSI Z21.60
Decorative Vented Appliances for Solid Fuel
Burning Fireplaces. State or local codes may only
allow operation of log sets in a vented configuration.
Check your state or local codes.
WARNING: If not installed, operated and maintained in accordance with the manufacturer's
instructions, this product could expose you to
substances in fuel or from fuel combustion which
can cause death or serious illness.
Page 120173-1-0506
TABLE OF CONTENTS
Section Page
Important Installation Guidelines ....................................................................................................................3
General Information ........................................................................................................................................3
Log Placement .................................................................................................................................................4
Ember Placement LS-18H-1 Photos ................................................................................................................5
Ember Placement LS-24H-1 Photos ................................................................................................................6
Ember Placement LS-30H-1 Photos ................................................................................................................7
Parts List & Parts View ....................................................................................................................................
How to Order Repair Parts ..............................................................................................................................8
8
Page 2 20173-1-0506
IMPORTANT INSTALLATION GUIDELINES
Proper Log Placement
Log placement is critical to proper burner performance. Logs
must be correctly positioned onto the burner. The photos in this
manual show the proper pinned position for logs on this set.
Owners need to be shown proper log placement and instructed
not to move the logs.
Logs must fit firmly onto the burner when positioned as shown
in the photos. Malformed logs or logs with sloppy pin holes must
be replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect.
It must be positioned only on the front portion of the burner. The
photos in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed
on the burner. These items are only for placement on the floor of
the fireplace or firebox.
Proper Primary Airflow into Burner
For proper burner operation and flame appearance, the flow of
primary air into the venturi tube, located on the rear of the burner,
must not be reduced. This flow of air is reduced if dirt, lint or other
obstructions build-up around or inside the venturi. Any obstruction
in the venturi tube area must be removed. The flow of air into the
venturi is also reduced if the gas orifice isn’t centered in the venturi
inlet and/or is not aligned with the venturi. Any misalignment of
the burner orifice may be corrected by bending the shutter cap
holding the orifice to the inlet of the venturi tube.
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
Ceiling fans or oscillating floor type fans need to be monitored
during the operation of vent-free logs. If the air blows directly
into the flame causing it to impinge on the log set, or firebox, it
should be turned off or redirected. Ceiling fans could be reversed
to possibly eliminate flame impingement, and the floor fan could
be redirected. Upon installation, be aware of any cold air returns
or vents in the proximity of the log set. Any draft created around
a vent-free log set can cause the flame to impinge on the log and
create a sooting situation.
WARNING: Do not allow fans to blow directly into the fireplace.
Avoid any drafts that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or
other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set
is in operation. Candles produce a residue in the air that creates a
soot like substance. Burning candles while the log set is operating
magnifies the problem. It should be noted that candles, in general,
produce soot. The amount of time burned and the quantity of
candles burned will determine the amount of soot produced and
deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit
soot on the logs. If users see soot appear on a log, call for service.
Do not continue to operate the log set.
Sunken Fireplace
If installing this unit into a sunken fireplace, you must raise the floor
to insure adequate airflow and guard against sooting. Raise fireplace
floor using a non-combustible material, which is secure.
Glass Doors
Make sure that glass doors are open during all operations of the
logset. The opening of the glass door frame should be the dimension
used for the minimum front opening of the firebox.
Woodburning Fireplaces
The interior of the firebox and the chimney should be cleaned and
free of all creosote before installing a gas burning log set. Creosote
will soften when heated and can drop on the logset causing odors
and possibly sooting.
WARNING: Before installing in a solid-fuel burning fireplace,
the chimney flue and firebox must be cleaned of soot, creosote,
ashes and loose paint by a qualified chimney cleaner.
GENERAL INFORMATION
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip
ment or accessories and repair and servicing of equipment shall
be performed only by a qualified agency. The term "qualified
agency" means any individual, firm, corporation, or company
that either in person or through a representative is engaged in and
is responsible for (a) the installation, testing, or replacement of
gas piping or (b) the connection, installation, testing, repair, or
servicing of equipment; that is experienced in such work; that is
familiar with all precautions required, and that has complied with
all the requirements of the authority having jurisdiction.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54
*Available from the American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10018.
.*
-
State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural
gas-fired space heaters shall be prohibited in bedrooms and
bathrooms.
Page 320173-1-0506