Empire Comfort Systems DVCD36FP30P-4, DVCD32FP30N-4, DVCD42FP30N-4, DVCD42FP30P-4, DVCD32FP31N-4 Homeowner's Manual

...
HOMEOWNER’S MANUAL
39669
INSTALLER:
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
— Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
— Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
DIRECT VENT
ZERO CLEARANCE GAS
FIREPLACE HEATER SERIES:
MILLIVOLT (MV)
DVCD(32,36,42)FP3(0,1)(N,P)-4
INTERMITTENT PILOT (IP)
DVCD(32,36,42)FP7(0,1)(N,P)-4
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certied kit is used.
DANGER
HOT GLASS
CAUSE BURNS.
DO NOT TOUCH
UNTIL COOLED.
NEVER
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
ALLOW CHILDREN
TO TOUCH GLASS.
WILL
GLASS
GAS-FIRED
UL FILE NO. MH30033
This replace is design certied in accordance with American National Standard/CSA Standard ANSI Z21.88/CSA 2.33 and by Underwriters Laboratories as a Direct Vent Gas Fireplace Heater and shall be installed according to these instructions.
Page 1
TABLE OF CONTENTS
SECTION PAGE
Combustible Material .................................................................................................................................. 2
Homeowner Reference Information ............................................................................................................ 2
Millivolt Standing Pilot Lighting Instructions (30) Series ............................................................................. 3
Millivolt Operating Instructions (30 Series) ................................................................................................. 4
Intermittent Pilot Lighting Instructions (FP7 Series) ................................................................................... 5
IPI Electronic System Operating Instructions (70 Series) ........................................................................... 6
Seasonal Shutdown .................................................................................................................................... 7
Maintenance And Service ......................................................................................................................8 - 9
Important Safety Information .................................................................................................................... 10
Annual Fireplace Inspection Checklist .......................................................................................................11
Safety Information For Users Of Propane Gas ......................................................................................... 12
Requirements For Massachusetts ............................................................................................................ 13
Warranty ................................................................................................................................................... 14
Appliance Service History ......................................................................................................................... 15
COMBUSTIBLE MATERIAL
WARNING
Do not attach combustible material above your replace. This is a re hazard. No greeting card, stockings or ornamentation of any type should be placed on or attached to the replace. This is a heating appliance. The ow of heat can ignite combustibles.
Figure 1
GENERIC MODEL SHOWN
Installing a television above a replace has become increasingly popular; however, the areas above any replace gets hot and most TV manufacturers recommend against placing their products near a heat source.
If you install a television above this replace insert, Empire Comfort Systems accepts no responsibility for damage or injuries. Follow the television manufacturers installation instructions, including any recommendations regarding proximity to heat sources.
If your have a TV above your replace turn off the replace and let it cool completely before servicing or touching any buttons on the TV.
Television Considerations
HOMEOWNER REFERENCE INFORMATION
We recommend that you record the following information about your replace.
Model Number: _____________________________ Date purchased: ________________________
Serial Number: _____________________________ Location of replace: _____________________
Dealer Name: ______________________________ Dealer Phone: _________________________
Notes: ______________________________________________________________________________
39669-0-0618Page 2
THERMOCOUPLE
ELECTRODE
PILOT
THERMOPILE
MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS (30 SERIES)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a re or explosion may result causing
property damage, personal injury, or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. Before lighting smell all around the appliance area for
gas. Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor.
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the re department.
LIGHTING INSTRUCTIONS
1. Stop! Read the safety information above.
2. Set REMOTE/OFF/ON switch to OFF.
3. Turn off all electric power to the appliance (if applicable).
4. Remove barrier screen.
5. Push in gas control knob slightly and turn clockwise to "OFF."
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless
knob is pushed in slightly. Do not force.
6. Wait ten minutes to clear out any gas. Then smell for gas,
including near the oor. If you then smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.
7. Find pilot - Follow metal tube from gas control. The
pilot is behind the burner on the right side.
8. Turn gas control knob counterclockwise to
"PILOT."
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualied service technician. Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
9. Push in control knob all the way and hold in. Repeatedly push the piezo ignitor button until the pilot is lit. Continue to hold the control knob in the for about one minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
If the control knob does not pop up when released,
STOP and IMMEDIATELY call a qualied service technician or gas supplier.
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service technician or gas supplier.
10. Turn gas control knob counterclockwise to "ON."
11. Replace barrier screen.
12. Turn on all electric power to the appliance (if applicable).
13. Set REMOTE/OFF/ON switch to desired setting.
TO TURN OFF GAS TO FIREPLACE
1. Turn off all electric power to the appliance if service is to be performed (if applicable).
2. Remove barrier screen.
3. Set REMOTE/OFF/ON switch to OFF.
39669-0-0618 Page 3
4. Push in gas control knob slightly and turn clockwise to “OFF.” Do not force.
5. Replace barrier screen.
MILLIVOLT OPERATING INSTRUCTIONS (30 SERIES)
MILLIVOLT SYSTEM
The standing pilot burns continuously even when the main burner is OFF.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in the control area.
2. During the operating season, leave the control valve knob in the “ON” position. This will allow the pilot ame to remain lit. Turn the burner ame on or off with the replace REMOTE/ OFF/ON switch, wall switch or remote controls.
NOTE: The gas control valve allows you to increase or decrease the height of the main burner ame. The control valve has a pressure regulator with a knob as shown in Figure 2. Rotate the knob counterclockwise to “HI” to increase the ame height and clockwise to “LO” to decrease the ame height.
3. When the heating season ends, turn the REMOTE/OFF/ON switch to “OFF” and the control valve to “OFF”. The system, including the pilot light, will be shut down.
Figure 2
NOTE: If batteries fail in the remote, and immediate heat is
desired, turn the REMOTE/OFF/ON switch from the REMOTE position to the ON position.
39669-0-0618Page 4
INTERMITTENT PILOT LIGHTING INSTRUCTIONS (FP7 SERIES)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a re or explosion may result causing
property damage, personal injury, or loss of life.
A. This appliance has a pilot which can be lighted with the
manual on/off switch, a remote control, or by switching the receiver switch to the “ON” position. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you can not reach your gas supplier, call the re department.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Turn OFF electric power to the appliance.
3. Remove front surround panel assembly or bottom louver if included.
4. Turn gas shut-off counterclockwise to “On” position.
5. Wait ten minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.
6. Turn ON electric power to the appliance.
7. Find pilot - Follow metal tube from gas control. The pilot is behind the burner on the right side.
8. Turn main ame to on. If the pilot does not light within 60 seconds, stop and go to Step 5.
C. Use only the remote control or manual remote receiver
switch to operate the gas valve. Never use tools. If valve does not operate, don’t try to repair it, call a qualied ser­vice technician. Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
9. Refer to remote control instructions for detailed information, control features, and operation. Note: There is a CPI/IPI switch that allows for a continuous standing pilot mode or an intermittent pilot mode. See appliance manual for location of this switch. If the pilot or burner does not stay lit (in the standing pilot mode), stop and immediately call a qualied service technician or gas supplier.
10. If the burner or pilot does not operate properly after several tries, turn the gas shut-off clockwise to “OFF” and call your service technician or gas supplier.
11. Replace the front surround assembly or close bottom louver assembly.
12. Operation of the gas valve is controlled by a manual on/ off switch or a hand held remote control. Refer to remote instructions for detailed operation information.
TO TURN OFF GAS TO FIREPLACE
1. Turn off all electric power to the appliance if service is to be performed (if applicable).
2. Gain access to control compartment. Remove surround panel assembly if necessary.
39669-0-0618 Page 5
GAS SHUT-OFF VALVE
3. Locate On/Off gas shut-off and turn clockwise to “OFF”. Do not force.
4. Close bottom louver assembly, if included.