WARNING: If not installed, operated and maintained in
accordance with the manufacturer’s instructions, this
product could expose you to substances in fuel or from fuel
combustion which can cause death or serious illness.
Attention: Check local codes for venting requirements.
Attention: This appliance may be installed in the U.S. and
Canada.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
AND
OWNER’S MANUAL
POWER-VENT
HIGH-EFFICIENCY
FIREPLACE WITH
BAY WINDOW MODELS
BF28(B,C,G)M(N,P)-3
BI28(B,C,G)M(N,P)-3
BP28(B,C,G)M(N,P)-3
FLAT FRONT MODELS
FF28BM(N,P)-1
FI28BM(N,P)-1
WARNING: If the information in these instructions
arenotfollowed exactly,a re orexplosionmay result
causing property damage, personal injury or loss of life.
Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are
atriskindividualsinthehouse.Torestrictaccesstoareplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of
the room and away from hot surfaces.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only) or
mobile home, where not prohibited by state or local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
withothergases,unlessacertiedkitisused.
Page 1
Page 2
TABLE OF CONTENTS
SECTION PAGE
Important Safety Information ....................................................................................................................................................................... 3
Safety Information for Users of LP-Gas ....................................................................................................................................................... 4
Requirements for Massachusetts ................................................................................................................................................................... 5
Gas Supply .................................................................................................................................................................................................... 6
Installation Instructions – General Safety Information ................................................................................................................................. 8
Clearances for Single Flue ............................................................................................................................................................................. 9
Heater Installation for Single Flue ................................................................................................................................................................. 9
Clearances for Direct Vent ........................................................................................................................................................................... 10
Heater Installation for Direct Vent ............................................................................................................................................................... 10
Bay Window Specications .................................................................................................................................................................. 11 - 12
Flat Front Specications .............................................................................................................................................................................. 13
Bay Window Clearance to Combustibles .................................................................................................................................................... 14
Flat Front Clearance to Combustibles .......................................................................................................................................................... 15
Insert Into Masonry Fireplace ...................................................................................................................................................................... 16
Bay Window Wall Clearances ...................................................................................................................................................................... 17
Flat Front Wall Clearances ........................................................................................................................................................................... 17
Bay Window Log Set Installation Instructions ............................................................................................................................................ 18
Flat Front Log Set Installation Instructions .......................................................................................................................................... 19 - 20
Vent Examples for Single Flue ............................................................................................................................................................. 20 - 22
Horizontal Examples for Colinear Direct Vent ............................................................................................................................................ 25
Vertical Examples for Colinear Direct Vent .......................................................................................................................................... 26 - 27
Horizontal Colinear Direct Vent Adaptor..................................................................................................................................................... 28
Termination Cap Vent .................................................................................................................................................................................. 29
Bay Window Gas Connection Installation Instructions ............................................................................................................................... 34
Flat Front Gas Connection Installation Instructions .................................................................................................................................... 35
F(F,I,W)K28(BL, CM, HP, SS)Surround Installation Instructions .............................................................................................................. 36
Fan Operation ............................................................................................................................................................................................... 41
General Information ..................................................................................................................................................................................... 45
Bay Window Maintenance .................................................................................................................................................................... 45 - 46
Flat Front Maintenance ......................................................................................................................................................................... 47 - 49
Unit Operating Faults ................................................................................................................................................................................... 50
Resetting the Heater ..................................................................................................................................................................................... 50
Main Convection Fan ................................................................................................................................................................................... 51
Bay Window Surround Installation Instructions .......................................................................................................................................... 51
Pedestal Installation Instructions - Bay Window Only ................................................................................................................................ 52
Master Parts Distributor List ........................................................................................................................................................................ 53
How To Order Repair Parts .......................................................................................................................................................................... 53
Bay Window Parts List ......................................................................................................................................................................... 54 - 55
Bay Window Exploded View ................................................................................................................................................................ 56 - 57
Flat Front Parts List ..................................................................................................................................................................................... 58
Flat Front Parts View ................................................................................................................................................................................... 59
Appliance Service History .................................................................................................................................................................... 61- 63
27020-3-0410Page 2
Page 3
IMPORTANT SAFETY INFORMATION
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.
they are in the same room as the appliance. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict
or residential installation convertible for use with
natural gas and liqueed petroleum gases when
provision is made for the simple conversion from one
gas to the other.
•Installation and repair should be done by a
QUALIFIED SERVICE PERSON. The appliance
should be inspected before use and at least annually
may be required due to excessive lint from carpeting,
bedding materials, etc. It is imperative that control
compartments, burners and circulating air passageways
of the appliance be kept clean.
to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
27020-3-0410Page 3
Page 4
SAFETY INFORMATION FOR USERS OF LP-GAS
Propane (LP-Gas) is a ammable gas which can cause res and
explosions. In its natural state, propane is odorless and colorless.
You may not know all the following safety precautions which can
protect both you and your family from an accident. Read them
carefully now, then review them point by point with the mem-
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
That’s your signal to go into immediate action!
• Do not operate electric switches, light matches, use your
phone. Do not do anything that could ignite the gas.
• Get everyone out of the building, vehicle, trailer, or area. Do
that IMMEDIATELY.
• Close all gas tank or cylinder supply valves.
• LP-Gas is heavier than air and may settle in low areas such
as basements. When you have reason to suspect a gas leak,
keep out of basements and other low areas. Stay out until
reghters declare them to be safe.
NO ODOR DETECTED - ODOR FADE
Some people cannot smell well. Some people cannot smell the
odor of the chemical put into the gas. You must nd out if you
can smell the odorant in propane. Smoking can decrease your
ability to smell. Being around an odor for a time can affect your
sensitivity or ability to detect that odor. Sometimes other odors
in the area mask the gas odor. People may not smell the gas odor
or their minds are on something else. Thinking about smelling a
gas odor can make it easier to smell.
The odorant in LP-gas is colorless, and it can fade under some
circumstances. For example, if there is an underground leak, the
movement of the gas through soil can lter the odorant. Odorants
bers of your household. Someday, there may not be a minute to
lose, everyone’s safety will depend on knowing exactly what to
do. If, after reading the following information, you feel you still
need more information, please contact your gas supplier.
• Use your neighbor’s phone and call a trained LP-Gas
service person and the re department. Even though you
may not continue to smell gas, do not turn on the gas again.
Do not re-enter the building, vehicle, trailer, or area.
• Finally, let the service man and reghters check for
escaped gas. Have them air out the area before you return.
Properly trained LP-Gas service people should repair the
leak, then check and relight the gas appliance for you.
in LP-Gas also are subject to oxidation. This fading can occur if
there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That
will take some of the odorant out of the gas, reducing its odor
intensity.
LP-Gas may stratify in a closed area, and the odor intensity
could vary at different levels. Since it is heavier than air, there
may be more odor at lower levels. Always be sensitive to the
slightest gas odor. If you detect any odor, treat it as a serious leak.
Immediately go into action as instructed earlier.
• Learn to recognize the odor of LP-gas. Your local LP-Gas
Dealer can give you a “Scratch and Sniff” pamphlet. Use it
to nd out what the propane odor smells like. If you suspect
that your LP-Gas has a weak or abnormal odor, call your
LP-Gas Dealer.
• If you are not qualied, do not light pilot lights, perform
service, or make adjustments to appliances on the LP-Gas
system. If you are qualied, consciously think about the
odor of LP-Gas prior to and while lighting pilot lights or
performing service or making adjustments.
• Sometimes a basement or a closed-up house has a musty
smell that can cover up the LP-Gas odor. Do not try to light
pilot lights, perform service, or make adjustments in an area
where the conditions are such that you may not detect the
odor if there has been a leak of LP-Gas.
• Odor fade, due to oxidation by rust or adsorption on walls
of new cylinders and tanks, is possible. Therefore, people
should be particularly alert and careful when new tanks or
cylinders are placed in service. Odor fade can occur in new
tanks, or reinstalled old tanks, if they are lled and allowed
to set too long before relling. Cylinders and tanks which
SOME POINTS TO REMEMBER
have been out of service for a time may develop internal
rust which will cause odor fade. If such conditions are
suspected to exist, a periodic sniff test of the gas is
advisable. If you have any question about the gas odor, call
your LP-gas dealer. A periodic sniff test of the LP-gas is a
good safety measure under any condition.
• If, at any time, you do not smell the LP-Gas odorant and
you think you should, assume you have a leak. Then take
the same immediate action recommended above for the
occasion when you do detect the odorized LP-Gas.
• If you experience a complete “gas out,” (the container
is under no vapor pressure), turn the tank valve off
immediately. If the container valve is left on, the container
may draw in some air through openings such as pilot light
orices. If this occurs, some new internal rusting could
occur. If the valve is left open, then treat the container as
a new tank. Always be sure your container is under vapor
pressure by turning it off at the container before it goes com-
pletely empty or having it relled before it is completely
empty.
27020-3-0410Page 4
Page 5
REQUIREMENTS FOR MASSACHUSETTS
For all side wall horizontally vented gas fueled equipment installed
in every dwelling, building or structure used in whole or in part
for residential purposes, including those owned or operated by the
Commonwealth and where the side wall exhaust vent termination
is less than seven (7) feet above nished grade in the area of
the venting, including but not limited to decks and porches, the
following requirements shall be satised:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS.
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gastter shall
observe that a hard wired carbon monoxide detector with an
alarm and battery back-up is installed on the oor level where
the gas equipment is to be installed. In addition, the installing
plumber or gastter shall observe that a battery operated
or hard wired carbon monoxide detector with an alarm is
installed on each additional level of the dwelling, building or
structure served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property owner
to secure the services of qualied licensed professionals for
the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
oor level.
b. In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that
during said thirty (30) day period, a battery operated
carbon monoxide detector with an alarm shall be
installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each
carbon monoxide detector as required in accordance with the
above provisions shall comply with NFPA 720 and be ANSI/
UL 2034 listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be
permanently mounted to the exterior of the building at a
minimum height of eight (8) feet above grade directly in line
with the exhaust vent terminal for the horizontally vented gas
fueled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side
wall horizontally vented gas fueled equipment shall not
approve the installation unless, upon inspection, the inspector
observes carbon monoxide detectors and signage installed in
accordance with the provisions of 248 CMR 5.08(2)(a) 1
through 4.
(b) EXEMPTIONS: The following equipment is exempt
from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled
“Equipment Not Required To Be Vented” in the
most current edition of NFPA 54 as adopted by the
Board; and
2. Product Approved side wall horizontally vented gas
fueled equipment installed in a room or structure
separate from the dwelling, building or structure
used in whole or in part for residential purposes.
(d) MANUFACTURER REQUIREMENTS - GAS
EQUIPMENT VENTING SYSTEM NOT PROVIDED.
When the manufacturer of a Product Approved side
wall horizontally vented gas fueled equipment does not
provide the parts for venting the ue gases, but identies
“special venting systems”, the following requirements
shall be satised by the manufacturer:
1. The referenced “special venting system” instructions
shall be included with the appliance or equipment
installation instructions; and
2. The “special venting systems” shall be Product
Approved by the Board, and the instructions for
that system shal include a parts list and detailed
installation instruction.
(e) A copy of all installation instructions for all Product
Approved side wall horizontally vented gas fueled
equipment, all venting instructions, all parts lists for
venting instructions, and/or all venting design instructions
shall remain with the appliance or equipment at the
completion of the installation.
27020-3-0410Page 5
Page 6
GAS SUPPLY
FLEX TUBING
3/8 NPT
NIPPLE
FLARE FITTING
GAS VA L V E
SOLENOID
FLARE SHUT OFF VA LV E
Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/
CGA-B149 (.1 or .2) installation code.
Recommended Gas Pipe Diameter
Pipe LengthSchedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Nat.L.P.Nat.L.P.
0-10 feet
0-3 meters
10-40 feet
4-12 meters
40-100 feet
13-30 meters
100-150 feet
31-46 meters
1/2”
12.7mm
1/2”
12.7mm
1/2”
12.7mm
3/4”
19mm
3/8”
9.5 mm
1/2”
12.7mm
1/2”
12.7mm
1/2”
12.7mm
1/2”
12.7mm
5/8”
15.9 mm
3/4”
19mm
7/8”
22.2 mm
3/8”
9.5 mm
1/2”
12.7mm
1/2”
12.7mm
3/4”
19mm
Note: Never use plastic pipe. Check to conrm whether your local
codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is
always best to consult your local authority and installation code.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings
— ANS Z21.45 Assembled Flexible Appliance Connectors of
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority
having jurisdiction. The state of Massachusetts requires that a exible
appliance connector cannot exceed three feet in length.
Figure 1
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of
the unit. Where none exists, or where its size or location is not
adequate, contact your local authorized installer for installation
or relocation.
Compounds used on threaded joints of gas piping shall be resistant
to the action of liqueed petroleum gases. The gas lines must be
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made.
A gas valve and ground joint union should be installed in the gas
line upstream of the gas control to aid in servicing. It is required
by the National Fuel Gas Code that a drip line be installed near
the gas inlet. This should consist of a vertical length of pipe tee
connected into the gas line that is capped on the bottom in which
condensation and foreign particles may collect.
Pressure Testing of the Gas Supply System
1. To check the inlet pressure to the gas valve, a 1/8" (3 mm) N.P.T.
plugged tapping, accessible for test gauge connection, must be
placed immediately upstream of the gas supply connection to
the appliance.
2. The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psig (3.5 kPa).
3. The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).
Attention! If one of the procedures results in pressures in excess
Both Propane and Natural gas valves have a built-in pressure
regulator in the gas valve. Natural gas models will have a manifold
pressure of approximately 3.5" w.c. (.872 kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 5.0" w.c.
(1.245 kPa) for the purpose of input adjustment to a maximum of
10.5" w.c. (2.614 kPa) Propane gas models will have a manifold
pressure approximately 7.0" w.c. (2.49 kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 11.0" w.c.
(2.739 kPa) for the purpose of input adjustment to a maximum of
13.0" w.c. (3.237 kPa).
A 1/8" (3 mm) N.P.T. plugged tapping, accessible for test gauge
connection, is located on the outlet side of the gas control.
27020-3-0410Page 6
Page 7
INTRODUCTION
Introduction
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
a direct vent wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner ll out and mail warranty card
supplied with furnace.
3. Installer should show owner how to start and operate furnace
and thermostat.
4. Installer must locate unit near a grounded wall receptacle for
115VAC power and must provide gas supply and vent the
unit properly for safe operation.
Warning:
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
General Information
This series is designed certied in accordance with American
National Standard/CSA Standard Z21.88 and CSA 2.33 by the
Canadian Standards Association as a Gas Fireplace Heater to be
installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown
on the rating plate is the responsibility of the person and
company making the change.
Important
All Correspondence should refer to complete Model Number,
Serial Number and type of gas.
Notice: During initial ring of this unit, oil from the heat
exchanger may bake out and smoke may occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is
installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18” (457 mm) above the oor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
QualiedInstallingAgency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equipment
shall be performed only by a qualied agency. The term “qualied agency” mean any individual, rm, corporation or company
which either in person or through a representative is engaged in
and is responsible for (a) the installation or replacement of gas
piping or (b) the connection, installation, repair or servicing of
equipment, who is experienced in such work, familiar with all
precautions required and has complied with all the requirements
of the authority having jurisdiction.
The installation must conform with local codes, or in the absence
of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA
54 or Natural Gas and Propane Installation Code, CSA B149.1.
* Available from the American National Standards Institute, Inc.,
11 West 42nd St., New York, NY 10036.
A manufactured home (USA only) or mobile home OEM
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or,
when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSIZ225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.0.
Sate of Massachusetts: The installation must be made by a
licensed plumber or gas tter in the Commonwealth of Massachusetts.
High Altitudes
For altitudes/elevations above 2,000 feet (610 m), input ratings
should be reduced at the rate of 4 percent for each 1,000 feet
(305 m) above sea level, this may be accomplished by reducing
manifold pressure. The maximum allowable reduction in manifold
pressure for Natural gas shall be from 3.5” w.c. (.872 kPa) to 2.8”
w.c. (.697 kPa). The maximum allowable reduction in manifold
pressure for Propane (LP) gas shall be from 10.0” w.c. (2.49 kPa)
to 8.0” w.c. (1.99 kPa). For Canadian high altitude applications,
this appliance is suitable for installation at elevations between
0 feet (0 m) and 4,500 feet (1,372 m) without change.
Canada:
This appliance may be installed in Canada.
27020-3-0410Page 7
Page 8
INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION
1. This installation must conform with local codes or, in the
absence of local codes with NFPA54.
2. Provide adequate clearances around the product for servicing
and ensure there are no obstructions to the combustion air
intake situated at the back of the heater. Refer to Pages 14 and
15.
3. The appliance must be installed on a at, solid continuous
surface (i.e. wood, metal, concrete). Please Note: Rough
or uneven surfaces can cause vibration or humming in the
heater.
4. The Mantis Power-Vent High-Effeciency Fireplace can be
installed in a wide variety of ways and will t nearly any
room layout. For installation options refer to Pages 14 and
15.
5. This appliance (Insert and Freestanding Models) needs to be
installed in such a way that the heater can be removed at all
times to service the heater exchanger and ue fan located in
the rear section of the heater.
SPECIFICATIONS
Note: Under no circumstances should the appliance be
installed under conditions which would not allow for
easy removal of the appliance to carry out routine
inspection and service to the appliance, to do so will
void the warranty.
Note: On Single Wall ue pipe installations (imitation
zero clearance replace) a minimum of 2” (50.8 cm)
clearance must be provided at the rear of the heater to
enable the heater to get sufcient combustion air to the
air inlet located at the rear of heater. Refer to installation
instructions on Pages 14 and 15.
Note:Where a mantel surround is being used on insert
installations and zero clearance replace installations,
the combustion air intake slot located in the top mantel
surround must have no obstructions to allow combustion
air to enter through the slot to the combustion air inlet
located at the back of the heater.
Bay Window Models B(F,I,P)28(B,C,G)M
Input BTU/HR (KW/H)19,000 Rear - 9,000 Front
Height25 1/8”
Width28 3/16”
Depth17 5/8”
Gas Inlet (Pipe)3/8” Flair
Electrical - Unit has a 5’ (1.5 m) 3 pronged cordset for con-
nection to an approved 115 VAC 60 Hz maximum
AMPs - 5A wall receptacle.
Flat Front ModelsF(F,I,W)28BM(N,P)
Input BTU/HR (KW/H)15,000 Rear - 13,000 Front
Height24 9/16”
Width28”
Depth17 3/16”
Gas Inlet (Pipe)3/8” Flair
Electrical - Unit has a 5’ (1.5 m) 3 pronged cordset for con-
nection to an approved 115 VAC 60 Hz maximum
AMPs - 5A wall receptacle.
Accessories
Common
Part NumberDescription
FRBTCBattery Operated Remote with Thermostat
FRBTP
PVCAColinear Adapter
PVCTColinear Transition
PVVK24HDirect Vent 24” Vent Kit
PVVK48HDirect Vent 48” Vent Kit
PVVK-CFAFlex Vent Kit
PVVK-SHSingle Flue Horizontal Vent Kit
PVVK-SVSingle Flue Vertical Vent Kit
PVVTCVertical Termination Cap - 1.5”
T24V24 Volt Thermostat
TMV2Two-Stage Thermostats
TRWWall Thermostat - Wireless Remote
TDV1Wall Thermostat - Wireless Remote
CIFPB-1CCorner Floor Pad Kit
CIPFP-1Floor Pad Kit
PV-2HTop Cover - Slim Assembly
PV-4HTop Cover - Short Assembly
PVE-16” Surround Assembly
PVPKPedestal Kit
PVSHRear Shroud
TRWWall Thermostat - Wireless Remote
Battery Operated Remote with Programmable
Thermostat
Bay Window
27020-3-0410Page 8
Page 9
CLEARANCES FOR SINGLE FLUE
1. Pick a location on a wall with a clear space in the room.
In selecting a location for installation, it is necessary to
provide adequate accessibility clearances for servicing and
proper installation. Be sure to locate the unit close enough to a
115 VAC wall receptacle to properly power appliance.
2. When facing the front of the furnace, the minimum clearances
from casing to combustible construction are 0” (0 mm) on top,
0” (0 mm) on each side, recommend 4” (102 mm) for servicing
and 0” (0 mm) from the oor and 2” (51 mm) to rear wall for
servicing and installation.
3. The minimum distance from the center of the vent cap to the
nearest outside corner or obstruction is 12” (305 mm).
HEATER INSTALLATION FOR SINGLE FLUE
The bottom of the exhaust vent terminal and the air intake shall
be located at least 12” (305 mm) above grade and must be vented
outside.
WARNING: The nearest point of the vent cap should be a
If this appliance is to be installed directly on carpeting, tile, or other
combustible material, other than wood ooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the re-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that can discolor.
Locating Wall Opening
The recommended location for this heater is on an outside wall
(the unit can be located on an inside wall but must not exceed 40’
(12.19 m) in exhaust vent length). Locate wall studs so that wall
vent opening will be located between wall studs. The wall opening
required for venting is a 1 7/8” (48 mm) minimum diameter
opening.
Refer to Pages 11 to 17 for positioning the heater on wall and for
locating gas line connection and vent opening. Heater can sit on
the oor.
27020-3-0410Page 9
Page 10
CLEARANCES FOR DIRECT VENT
1 9/16”
4 3/32”
1. Pick a location on a wall with a clear space in the room.
In selecting a location for installation, it is necessary to
provide adequate accessibility clearances for servicing and
proper installation. Be sure to locate the unit close enough to a
110 VAC wall receptacle to properly power appliance.
2. When facing the front of the furnace the minimum clearances
from casing to combustible construction are 0” (0 mm) on top,
0” (0 mm) on each side, recommend 4” (102 mm) on sides
for servicing and 0” (0 mm) from the oor, 0” (0 mm) to rear
wall and 40” (1,016 mm) from Mantis top to ceiling.
3. The minimum distance from the center of the vent cap to the
nearest outside corner or obstruction is 12” (305 mm).
4. The minimum wall depth is 4” (102 mm) and the maximum
is 48” (121.92 cm).
The vent terminal of a direct vent appliance, with an input of
50,000 BTU (14.6KW) per hour or less shall be located at least
9” (229 mm) from any opening through which ue gases could
enter a building.
The bottom of the exhaust vent terminal and the air intake shall
be located at least 12” (305 mm) above grade and must be vented
outside.
WARNING: The nearest point of the vent cap should be
If this appliance is to be installed directly on carpeting, tile, or other
combustible material, other than wood ooring, the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the re-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that can discolor.
HEATER INSTALLATION FOR DIRECT VENT
Locating Wall Opening
The recommended location for this furnace is on an outside wall.
Locate wall studs so that wall vent opening will be located between
wall studs. The wall opening required for venting is a 3 1/2”
(89 mm) minimum diameter opening.
Refer to Pages 11 to 17 for positioning the heater on wall and for
locating gas line connection and vent opening. Furnace can sit on
the oor.
Figure 2
27020-3-0410Page 10
Page 11
BAY WINDOW SPECIFICATIONS
28 3/16”
(71.6cm)
33 3/4”
(85.7cm)
8 5/8”
(21.9cm)
17 5/8”
(44.8cm)
5 - SINGLE FLUE ADAPTOR
12 1/4”
(31.1cm)
1 - FLUE OUTLET
28 3/16”
(71.6cm)
25 1/8”
(63.8cm)
27 3/4”
(70.5cm)
17 5/8”
(44.8cm)
3 9/16” (9.0cm)
16 15/16”
(43.0cm)
1 - FLUE OUTLET
5 - SINGLE FLUE ADAPTOR
Index No.Description
1Flue Outlet 1 1/2” PVC Pipe
2Air Inlet
3Electric Cord
43/8” Flare Connection (Inside)
5Single Flue Adaptor Model (Required)
6Surround
PVE1-1 Used on openings less than 35”
PVE2-1 Used on openings less than 37 1/2” openings
7Top Cover Kit, Slim Model #PV2H
8Top Cover Kit, Short
27020-3-0410Page 11
Heater with Pedestal and Single Flue Adaptor
Heater without pedestal
Page 12
35 7/16”
(90.0cm)
29 3/4”
(75.6cm)
5 15/16” (15.1cm)
23 13/16”
(60.5cm)
10 1/8”
(25.7cm)
6 3/16”
(15.7cm)
3 9/16” (9.0cm)
16 15/16”
(43.0cm)
8 -TOP COVER KIT,
SHORT
1 - FLUE OUTLET
5 - SINGLE FLUE
ADAPTOR
LOUVER
BAY WINDOW SPECIFICATIONS - (continued)
35 7/16”
(90.0cm)
29 3/4”
(75.6cm)
5 15/16”(15.1cm)
23 13/16”
(60.5cm)
10 1/8”
(25.7cm)
6 3/16”
(15.7cm)
3 9/16”(9.0cm)
16 15/16”
(43.0cm)
6 - SURROUND
ASSEMBLY
1 - FLUE
OUTLET
13/16” (2.1cm)
2 - AIR INLET
7 9/16”
(19.2cm)
2 13/16”
(7.1cm)
1 7/16”
(3.7cm)
4 - ½” FLARE
CONNECTION
INSIDE
6 1/8”
(15.6cm)
1 ½”
(3.8cm)
3 9/16”
(9.0cm)
1”
(2.5cm)
3 - ELECTRIC
CORD
8-TOPCOVER KIT,
SHORT
1- FLUE OUTLET
5- SINGLE FLUE
ADAPTOR
LOUVER
Fireplace Insert with Mantel Surround with Slim Top Panel
Fireplace Insert with Mantel Surround with Short Top Panel
Rear View (Same with or without pedestal and all tops)
27020-3-0410Page 12
Page 13
FLAT FRONT SPECIFICATIONS
35”
(88.9cm)
33 7/16”
(84.9cm)
35”
(88.9cm)
29 3/8”
(74.6cm)
38”
(96.5cm)
30 7/8”
(78.4cm)
1 - FLUE
OUTLET
2 - AIR INLET
3 - ELECTRIC
CORD
4 - FLEX HOSE
OPENING
1 1/8” (2.8cm)
7 5/16”
(18.6cm)
4 3/16”
(10.6cm)
2 5/8”
(6.7cm)
6 1/8”
(15.6cm)
3 9/16”
(9.0cm)
13/16”
(2.1cm)
1” (2.5cm)
17”
(43.2cm)
3 9/16” (9.0cm)
1 - FLUE OUTLET
5 - SINGLE FLUE ADAPTOR
MODEL #PVVK-SH
6 1/2” (16.5cm) MIN.
WITH 90° STREET ELBOW
24 3/4” MIN
(62.8cm)
Heater In Wall - 35” Picture Frame Surround
FWK28(BL,CM,HP,SS) - Contains surround, hood, and lower
front
Heater-35”SurroundKit
FFK28(BL,CM,HP,SS) - Contains surround, hood, & lower front
Heater - 38” Surround
FIK28(BL,CM,HP,SS) - Contains surround, hood, & lower front
27020-3-0410Page 13
Index
Description
No.
1Flue Outlet 1 1/2” PVC Pipe
2Air Inlet
3Electric Cord
43/8” Flare Connection (Inside)
5Single Flue Adaptor Model #PVVK-SH (required)
Page 14
BAY WINDOW CLEARANCE TO COMBUSTIBLES
C
C
A
BB
33 1/4”
(84.5cm)
29 3/4”
(75.6cm)
12”
(30.5cm)
26 ½”
(67.3cm)
35 7/16”
(90.0cm)
WALL OPENING
D
LOUVER
12”
18”
24”
8”
6”
4”
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
40”
CEILING
Freestanding Models
Figure 3Figure 4
Freestanding Units
ARear Wall to Heater0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability)
BSide Wall to Heater0” (4” recommended for serviceability)
CCorner Installation0”
DMantel ClearanceSee Figure 7
Fireplace Insert
Requires surround for combustion air.
Single Flue
Do not cover surround louver.
Figure 5
Single Flue requires surround for combustion air.
Direct Vent Installation Shown
Figure6
Note: The Mantis Power-Vent High-Efciency Fireplace has been tested and approved for zero clearance to combustible materials.
Empire Comfort Systems, Inc. recommends that clearances as listed above should be maintained to allow for removal of the
product for servicing.
Mantel and Ceiling Clearances
Figure 7
27020-3-0410Page 14
Page 15
FLAT FRONT CLEARANCE TO COMBUSTIBLES
37”
(93.98 cm)
30 7/8”
(78.4cm)
12”
(30.5cm)
26 ½”
(67.3cm)
38”
(96.5cm)
WALL OPENING
D
A
A
BB
6 1/4”
MIN
C
C
12”
18”
24”
8”
6”
4”
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
44 3/4”
CEILING
4 3/4”
Insert Models
Figure 8Figure 10
Figure 9
Freestanding Units
ARear Wall to Heater0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability)
BSide Wall to Heater0”
CCorner Installation0”
DMantel ClearanceSee Figure 12
Fireplace Insert
Requires surround for combustion air.
Note: The Mantis Power-Vent High-Efciency Fireplace has been tested and approved for zero clearance to combustible materials.
Empire Comfort Systems, Inc. recommends that clearances as listed above should be maintained to allow for removal of the
27020-3-0410Page 15
product for servicing.
Do not cover surround louver.
Single Flue
Figure 11
Mantel and Ceiling Clearances
Figure 12
Page 16
ROUGH FRAMING DIMENSIONS
A
B
C
ACCESS
PANELS
ACCESS
PANELS
1.5”
BAY WINDOW
A - 13 /34” MIN. CO-LINEAR
8 1/2” WHEN USING DIRECT VENTING
NOTE: DIMENSIONS FOR USE WITH SHORT TOP.
THIS IS RECOMMENDED FOR UNIT SERVICEABILITY.
B - 25 1/8”
C - 28”
NOTE: IF TRIM AROUND HEATER IS NECESSARY, THE
SURROUND KIT PVE1-1 OR PVE2-1 MUST BE
USED, AND SUBTRACT 1” FROM (A) DIMEN-
Figure 13
FLAT FRONT
A - 23 1/2” MIN. WITH 90° STREET ELBOW
B - 24 3/4”
C - 28 3/16” MIN., 31” RECOMMENDED FOR
NOTE: HEATER WILL BE 0” CLEARANCE ON RIGHT
D - 4” - 6”
NOTE: ONLY ONE ACCESS PANEL (FIGURE 14) IS NEED-
Figure 14
SION.
27 3/4” IF FGK SURROUND IS USED
SERVICEABILITY.
AND 3” ON LEFT FOR SERVICEABILITY.
ED. INSTALLER TO DETERMINE BEST OPTION.
INSERT INTO MASONRY FIREPLACE
BAY WINDOW
A - 12 3/4” MIN. SHORT TOP
17 13/16” MIN. SLIM TOP
USING SURROUND KIT
B - 25 1/8” MIN. DIRECT VENT
26 1/2” MIN. SINGLE FLUE
29” MAX
C - 28” MIN. NO SURROUND
33” MIN. WITH PVE-1 SURROUND
35” MAX. WITH PVE-1 SURROUND
37” MAX. WITH PVE2-1 SURROUND
FLAT FRONT
A - 23 1/2” WHEN USING FI28(BL,CM,HP,SS) SUR-
ROUND
Figure 15
B - 24 3/4” MIN. DIRECT
29” MAX
C - 28 3/16” MIN. WITH SURROUND
37” MAX. WITH 38” SURROUND
D - 4”
27020-3-0410Page 16
Page 17
BAY WINDOW WALL CLEARANCES
12 23/32”
6”
11 3/32”
17 13/16”
PVVK-CFA
PVVK-SH
PVE-1
6 ½”
6 ½”
23 1/2”
(59.7cm)
6 ½”
(16.5cm)
24 3/4”
(62.8cm)
MIN.
Figure16
FLAT FRONT WALL CLEARANCES
27020-3-0410Page 17
Figure 17
Page 18
BAY WINDOW LOG SET INSTALLATION INSTRUCTIONS
A
B
C
D
E
PLATE - LOG SUPPORT
FRONT HOT SURFACE IGNITOR
REAR HOT SURFACE IGNITORREAR FLAME SENSOR
FRONT FLAME SENSOR
REAR BURNER
FRONT BURNER
F
G
Log Installation
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the
logs are not properly and rmly positioned in the appliance.
Note:Before you begin: Do not handle these logs with your
bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with
soap and water.
1. To access the log set parcel, lift off top panel.
2. Pivot left and right panels open.
3. Unlatch main door latches located on right and left side of the
heater, remove door.
4. Connect Rear Left Log (A) and Rear Right Log (B) at pins on
sides of each log and place in rear of burner. Logs should be
all the way to the back of the rebox.
5. Place Front Left Log (C) into groove on (A) Log and into left
corner of rebox.
6. Place Middle Log (D) over ame sensors in middle of re-
box.
7. Place Front Right Log (E) into right front corner of rebox.
8. Place Top Left Log (F) onto pin on (A) Log. The “legs” of (F)
Log will rest on (D) Log
9. Place Top Right Log (G) onto pin on (B) Log. The “legs” of
(G) Log will rest on (E) Log.
10. Place Door Assembly onto front of heater and latch main
door latches located on right and left sides of the heater.
11. Close left and right panels.
12. Installation of log set is complete.
Log Placement
Figure 17a
Log Placement
Figure 17b
Firebox Layout
Figure 18
Log Placement
Figure 17c
27020-3-0410Page 18
Page 19
FLAT FRONT LOG SET INSTALLATION INSTRUCTIONS
REAR LOG SUPPORT
FRONT LOG SUPPORT
FIREBOX BOTTOM
REAR HOT SURFACE IGNITOR
REAR FLAME SENSOR
REAR BURNER
RIGHT REAR
LOG SUPPORT
SHELF
FRONT BURNER
FRONT FLAME SENSOR
FRONT HOT SURFACE IGNITOR
LEFT REAR
LOG SUPPORT
SHELF
B
F
D
A
H
C
G
E
Log Installation
The positioning of the logs is critical to the safe and clean
operation of this heater. Sooting and other problems may result if
the logs are not properly and rmly positioned in the appliance.
Note:Before you begin: Do not handle these logs with your bare
hands! Always wear gloves to prevent skin irritation.
After handling logs, wash your hands gently with soap and
water.
Note:See Page 47 for Glass Assembly removal and
replacement.
Log Placement
1. Place Rear Log (A) onto rear log support. The notch in the
Rear Log ts over the rear Hot Surface Ignitor.
2. Place Left Log (B) on left rear log support shelf. The charred
portion of the log must face inward.
3. Place Middle Log (D) on front log support between the front
and back burners.
4. Place Front Right Log (F) on right side of Firebox bottom.
Notch in bottom of Front Right Log ts over the front Flame
sensor. See Figure 20A.
5. Place Front Left Log (E) on left side of Firebox bottom.
Notch in bottom of Front Left Log ts over front Hot Surface
Ignitor. See Figure 20B.
6. Place Right Log (C) on right rear log support shelf. Top of
log rests on Rear Log (A) and bottom of log rests on Firebox
bottom. Charred portion of log must face inward.
7. Place Left Top Long Log (G) on the pin on Left Log (B). The
upper left leg of Left Top Log will rest on Rear Log (A). The
upper right leg of Left Top Log will rest on Middle Log (D).
8. Place Right Top Long Log (H) on the pin on the Right Log
(C). The bottom left leg of the Right Top Log will rest in the
indent on the right side of the Middle Log (D). The bottom
right leg of the Right Top Log will rest in the indent in the
Front Right Log (F).
Figure 20A
Figure 20B
27020-3-0410Page 19
Figure 21
Page 20
FLAT FRONT LOG SET INSTALLATION INSTRUCTIONS
A- Rear Log
B-Left Log
C-Right Log
D-Middle Log
E-Front Left Log
F-Front Right Log
G-Left Top Log
H-Right Top Log
EXTERIOR GRADE
12” MIN.
6” MIN.
MIN. 2”
12” MIN.
SINGLE FLUE ADAPTOR
LOG SET DIAGRAM - A
The Gas Log Kit contains the following:
Index LetterLog Description
ARear Log
BLeft Log
CRight Log
DMiddle Log
EFront Left Log
FFront Right Log
GLeft Top Log
HRight Top Log
Figure 22
VENT EXAMPLES FOR SINGLE FLUE
Max Vent Run - 40 ft. Equivalent With Three (3) 90° Elbows
Note: On horizontal runs, a P.V.C. support clamp needs to be in-
stalled every 3 feet. No “sags” in horizontal vent runs; water will
settle in the pipe.
When installing a single ue horizontal, the minimum vent length
protruding from the outside wall is 6” (15.2 cm). See Figure 23.
Minimum vent from the rear of the unit is 12”.
Note: Horizontal discharge 90° elbow must be pointed downward. See Figure 23. All horizontal runs require either a 1/4” per
foot rise to run condensation back to the heater, or a 1/4” per foot
downward slope to run condensation away from the heater.
Note: All PVC vent run piping can be purchased at a local hardware store. Schedule 40 PVC pipe should be used and cemented.
Flex Kit and Horizontal Vent Adaptor Kit are available from Empire Comfort Systems, Inc.
Figure 23
Single Flue - Straight Out Back
Min6”OutsideWall
Min 2” From Unit to Wall for Intake Air
Min vent length 12”
Figure 24
SingleFlue-VentingwithShroudKitInstalled
27020-3-0410Page 20
Page 21
90
ELBOW°
2’
(61.0cm)
27’
(8.2m)
5’
(1.5m)
VENT TERMINAL
90° ELBOW
(NOT COUNTED)
3 FEET
FIRST 90
DOES NOT GET COUNTED
WHEN WITHIN 6” (15.2cm)
OFF BACK OF HEATER
° ELBOW
VENT EXAMPLES FOR SINGLE FLUE (cont.)
90 ELBOW°
36’
(11m)
1’
(30.5cm)
SINGLE FLUE ADAPTOR
90° ELBOW
EXTERIOR GRADE
FLUE CENTER
6”
(15.2cm)
MIN.
12” (30.5cm) MIN.
1/4” DOWNWARD SLOPE
PER FOOT TO OUTSIDE
H = 5’ + 2’ = 7’
V = 27’
(2) - 90° = 6’
Total = 40’
WARNING: Major U.S. building codes specify minimum chim-
ney and/or vent height above the rooftop. These minimum heights
are necessary in the interest of safety. These specications are
summarized in Figure 28.
Determining Minimum Vent Height Above the Roof
ROOF PITCHH (Min.)
Flat to 6/1212” (305 mm)
6/12 to 7/1215” (381 mm)
Over 7/12 to 8/1218” (457 mm)
Over 8/12 to 16/1224” (610 mm)
Over 16/12 to 21/1236” (914 mm)
Figure 28
Single Flue - Vertical Vent Run
with 45 degree elbows
Flat Front Top View
A - 23 1/2” (597 mm) Min. with 90° Street Elbow
B - 28 3/16” (716 mm)
C - 31 3/16” (792 mm) Min., 31” Recommended for
serviceability.
Note:Heater will be 0” clearance on right and 3” on left for
serviceability.
Figure 29
27020-3-0410Page 22
Page 23
FLEXVENTKIT
Cement PVC Joints
Cut End
Cement PVC Joints
FLEXIBLE VENT KIT
WITH 1 1/2” COUPLING
ON EACH END
FLEXIBLE GAS
LINE
PVC PIPE SWV
(SUPPLIED BY INSTALLER)
(2) - 45 DEG. PVC BENDS
(SUPPLIED BY INSTALLER
IF NECCESSARY)
GALV. SHEET FLASHING
TO SEAL CHIMNEY
(SUPPLIED BY INSTALLER)
VENT CAP (SUPPLIED
WITH VENT KIT)
SURROUND KIT
MODEL #PVE1-1
OR PVE2-1
42”
(1.2m)
SINGLE FLUE ADAPTOR
40”
Available from Empire Comfort Systems, Inc.
The ex vent kit is a exible vent hose that is 42” in length. The ex vent kit will be used when installing a Mantis into an existing
replace. The ex vent kit can be cut down, but can only be cut from one end.
Once length is determined, install two (2) 10 x 1/2” screws into the adaptor assembly to secure the adaptor assembly to the ex hose.
Using PVC cement, cement all PVC joints of the ex vent kit to the remaining PVC vent run.
Determining Minimum Vent Height Above the Roof
WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are
necessary in the interest of safety.
V = 40’
Total = 40’
ROOF PITCHH (Min.)
Flat to 6/1212” (305 mm)
6/12 to 7/1215” (381 mm)
Over 7/12 to 8/1218” (457 mm)
Over 8/12 to 16/1224” (610 mm)
Over 16/12 to 21/1236” (914 mm)
Venting for Existing Fireplace Installation
Figure 30
27020-3-0410Page 23
Page 24
INSTALL FOAM GASKET
FLUE ADAPTOR
PLASTIC GASKET
THREADED CONNECTOR
HORIZONTALVENTADAPTORKIT
Available from Empire Comfort Systems, Inc.
8 x 1/2” Phillips Truss Head Screw
Attach ue adaptor to back of heater with four (4) screws.
Note: No PVC cement is needed
Install plastic gasket and screw threaded connector to the ue adaptor.
When these connections are made, continue with your vent run.
Cement all PVC joints on vent run.
to install ue adaptor kit.
27020-3-0410Page 24
Page 25
HORIZONTAL EXAMPLES FOR COLINEAR DIRECT VENT
EXTERIOR GRADE
REAR SHROUD
12” MIN.
MODEL PVCT
SINGLE FLUE ADAPTER
CO-LINEAR DIRECT VENT ADAPTER
6” MIN.
9” MIN.
OUTDOOR SEALANT
REQUIRED
TOP VIEW
EXHAUST
EXHAUST
12” MIN.
EXTERIOR GRADE
3” MIN.
2.5”
AIR INTAKE
AIR INTAKE
TRANSITION PLATE
EXTERIOR GRADE
12” MIN.
9” MIN.
MIN. 2”
6” MIN.
3” MIN.
Max Vent Run - 40 ft. Equivalent With Three (3) 90° Elbows
Note: On horizontal runs, a P.V.C. support clamp needs to be
installed every 3 feet. No “sags” in horizontal vent runs; water
will settle in the pipe.
When installing a colinear horizontal, the minimum vent length
protruding from the outside wall is 6” (15.2 cm) for air intake and
9” for exhaust. See Figure 34.
Note: Horizontal discharge 90° elbow must be pointed
downward. See Figure 32. All horizontal runs require either a 1/4”
per foot rise to run condensation back to the heater, or a 1/4” per
foot downward slope to run condensation away from the heater.
Note: All PVC vent run piping can be purchased at a local
hardware store. Schedule 40 PVC pipe should be used and cemented.
Horizontal Colinear Direct Vent Adaptor, Cap, Flex Kit and PVVK-SH Horizontal Vent Adaptor Kit are available from Empire
Comfort Systems, Inc.
Figure 31
In both vertical and horizontal colinear direct vent applications,
a colinear transition plate can be used to minimize clearances between intake and exhaust pipes.
For horizontal colinear direct venting, exhaust and intake air, cap
pipes with 90º elbows, pointed downward.
Note: If transition plate is used, the measurement for center to
center of the pipes will be 2.5”. If the transition plate is not used,
the measurement for center to center of the pipes can be 3” to 24”
maximum.
Figure 32
Figure 33
Note: Must maintain a minimum 3” between
exhaust outlet and air intake.
27020-3-0410Page 25
Figure 34
Enhanced top view of Figure 33
Page 26
6’
5’
10’
10’
SINGLE FLUE ADAPTER
CO-LINEAR DIRECT VENT ADAPTER
FIRST 90
DOES NOT GET COUNTED
WHEN WITHIN 6” (15.2cm)
OFF BACK OF HEATER
Note: Exhaust must be a minimum of 3”
above air intake inlet.
Determining Minimum Vent Height Above the Roof
WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are
necessary in the interest of safety.
Figure 35
Calculation example of vent run maximum 40’
27020-3-0410Page 26
Page 27
VERTICAL EXAMPLES FOR COLINEAR DIRECT VENT
3” MIN.
EXHAUST: VERTICAL TERMINATION
CAP 1.5”, PTRAP OR 2 90° ELBOWS
AIR INTAKE
PTRAP OR 2 90° ELBOWS
(SUPPLIED BY INSTALLER)
SINGLE FLUE
EXHAUST
AIR INTAKE
CO-LINEAR
DIRECT VENT ADAPTER
AT TACH OPTIONAL VENT KIT
MODEL PVCT PLATE TO GALV.
SHEET FLASHING (CHASE)
WITH (4) SCREWS.
USE OUTDOOR SEALER
BETWEEN PLATE AND CHASE.
45° ELBOW
45° ELBOW
FLEX PVC PIPE
WITH 1.5” COUPLING
ON EACH END
FLAT ROOFFLAT ROOF
2.5”- 24”
SINGLE FLUE
CO-LINEAR
DIRECT VENT ADAPTER
12
X
HEIGHT
FLASHING
REQUIRED
HEIGHT
AIR INTAKE
PTRAP, 2 90° ELBOWS (SUPPLIED
BY INSTALLER) OR TERMINATION CAP.
PTRAP TO FACE AWAY FROM ROOF.
EXHAUST
TERMINATION CAP, PTRAP
OR 2 90° ELBOWS
OPTION
3” - 24”
Note: Exhaust must be a minimum
of 3” above air intake inlet.
Determining Minimum Vent Height Above the Roof
WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are
necessary in the interest of safety. These specications are summarized in Figure 37.
In both vertical and horizontal colinear direct vent applications, a colinear transition plate can be used to minimize clearances between
intake and exhaust pipes.
For exhaust and intake air, cap pipes with any of the following: Vertical termination cap, PTrap, or two 90º elbows. When transition
plate is used, two termination caps may NOT be used.
Colinear Direct Vent - Insert Installation
See Figure 31, Page 25.
Note: If transition plate (model PVCT) is used, the measurement for center to center of the pipes will be 2.5”. If the transition plate
(model PVCT) is not used, the measurement for center to center of the pipes can be 3” to 24” maximum.
Figure36
ROOF PITCHH (Min.)
Flat to 6/1212” (305 mm)
6/12 to 7/1215” (381 mm)
Over 7/12 to 8/1218” (457 mm)
Over 8/12 to 16/1224” (610 mm)
Over 16/12 to 21/1236” (914 mm)
Colinear Direct Vent - Pitched Roof Installation
Figure 37
27020-3-0410Page 27
Page 28
HORIZONTAL COLINEAR DIRECT VENT ADAPTOR
COLINEAR ADAPTER
SINGLE FLUE HORIZONTAL
4 13/16”
3 15/16”
6 1/8”
7 9/16”
Colinear adaptor to be used in conjunction with single ue horizontal vent kit. The two attachments are used for colinear direct vent
installation.
Colinear adaptor
1. Attach colinear adaptor to back of heater with two (2)
screws.
8 x 1/2” Phillips Truss Head Screw
2. When adapter is connected, continue with your vent run.
Cementing PVC joint is recommended, but not required on
colinear fresh air intake adaptor.
27020-3-0410Page 28
Page 29
TERMINATIONCAPVENTKIT
PVC CEMENT
Available from Empire Comfort Systems, Inc.
Termination Cap
Vertical exhaust cap used with 1 1/2” PVC pipe installation.
Termination cap also used with colinear transition plate.
27020-3-0410Page 29
Refer to instruction manual for venting examples.
Page 30
COLINEARTRANSITIONVENTKIT
AIR INTAKE
PTRAP OR290° ELBOWS
SUPPLIED BY INSTALLER
TRANSITION PLATE
PVC CEMENT
PVC CEMENT
OUTDOOR SEALER REQUIRED
OPTIONALCAP
ORDER SEPARATE
EXHAUST
3” MIN.
HEIGHT (MIN.12”)
AIR INTAKE
PTRAP OR290° ELBOWS
SUPPLIED BY INSTALLER
TRANSITION PLATE
PVC CEMENT
PVC CEMENT
OUTDOOR SEALER REQUIRED
3” MIN.
HEIGHT (MIN.12”)
EXHAUST
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
Available from Empire Comfort Systems, Inc.
Colinear Transition Plate
Note: Exhaust must be a minimum of 3” above air intake inlet.
Flat Roof or Chimney Application
1. Attach plate to chimney chase or at roof with four (4) screws. Use outdoor sealant to seal transition plate to the roof or chimney
chase.
2. Check local codes to determine air intake height from roof. The minimum height for this application is 12”.
3. Cut 1 1/2” PVC pipe to correct height. Attach pipe, PTrap, and exhaust cap to plate. Glue all joints with PVC cement.
See Figure 31, Page 25.
HorizontalApplication
1. Attach plate to outside wall with four (4) screws. Use outdoor sealant to seal transition plate to the wall.
2. Cut 1 1/2” PVC pipe to correct length. The minimum length for this application is 9” for the exhaust and 6” for the air intake. Glue
all joints with PVC cement.
27020-3-0410Page 30
Page 31
DIRECT VENT INSTALLATION INSTRUCTIONS
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)
MIN.
FLOOR PROTECTION
FLOOR PROTECTION
NO HEARTH REQUIRED
EXTERIOR GRADE
FLUE CENTER
1 1/4”
(3.2cm)
MIN.
12”
(30.5cm)
MIN.
EXTERIOR GRADE
FLUE CENTER
12”
(30.5cm)
MIN.
Installation on Rugs and Tile
If this appliance is to be installed directly
on carpeting, tile, or other combustible
material, other than wood ooring, the
appliance shall be installed on a metal or
wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean
the re-proof base as used on wood stoves.
The protection is primarily for rugs that may
be extremely thick and light-color tile that
can discolor.
Minimum Exterior Grade Dimension - Unit Without Pedestal
Figure 38
Minimum Exterior Grade Dimension - Unit With Pedestal (Bay Window Models Only)
elbow. 45° elbow can be purchased from a local hard-
ware store.
Figure 44
27020-3-0410Page 33
Page 34
BAY WINDOW GAS CONNECTION INSTALLATION INSTRUCTIONS
FLEXIBLE GAS
LINE
GAS CONNECTION (Line Supply)
A 3/8” Flair gas line connection is supplied in the heater
GAS SUPPLY LINE TO HEATER
a. Remove rubber grommet from back panel and pull out ex line through back panel.
b. Connect gas supply line to exible gas hose. Ensure that exible gas hose is not kinked after tting gas supply line.
c. After gas supply line has been brought through from rear of heater, place rubber grommet supplied over gas line.
Note: The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its
location for servicing of the heater. For replace insert installations, incorporate either a copper loop into the supply line or exible hose
being used for the gas supply to the heater to allow for easy removal of the appliance.
Note: Under no circumstances should the gas supply line to the appliance be installed under conditions, which would not allow for
easy removal of the appliance to carry out routine inspection and service to the appliance.
Figure 45
27020-3-0410Page 34
Page 35
GAS CONNECTION INSTALLATION INSTRUCTIONS
PUSH IN PLUG
ACCESS PLATE
GAS CONNECTION (Line Supply)
A 3/8” Flair gas line connection is supplied in the heater
GAS SUPPLY LINE TO HEATER
1. Pull ex line through top hole in back panel.
2. Connect gas supply line to exible gas hose. Ensure that
exible gas hose is not kinked after tting gas supply
line.
3. Push excess ex line back into heater and place rubber
grommet (supplied in hardware packet) over gas line at
hole to prevent movement.
Note: The gas supply line to the heater must be installed under
conditions which will allow for easy removal of the heater from
its location for servicing of the heater. For replace insert installations, incorporate either a copper loop into the supply line or
exible hose being used for the gas supply to the heater to allow
for easy removal of the appliance.
Note: Under no circumstances should the gas supply line to the
appliance be installed under conditions, which would not allow
for easy removal of the appliance to carry out routine inspection
and service to the appliance.
Shown with side removed for clarication.
Figure46
GAS CONNECTION INSTALLATION INSTRUCTIONS - IN-WALL UNITS
1. Remove access plate on the left side by removing three
screws as shown in Figure 47.
2. Ppush gas line from back of unit through the access cut out on
the side.
3. Remove the knockout from the access plate and insert gas
line through the hole.
4. Place access plate and secure with three screws removed in
Step 1.
5. Use the plastic plug supplied in the hardware package to plug
the hole in the back of the unit.
Note: The gas supply line to the heater must be installed under
conditions which will allow for easy removal of the heater from
its location for servicing of the heater. For replace insert installations, incorporate either a copper loop into the supply line or
exible hose being used for the gas supply to the heater to allow
for easy removal of the appliance.
Note: Under no circumstances should the gas supply line to the
appliance be installed under conditions, which would not allow
for easy removal of the appliance to carry out routine inspection
and service to the appliance.
Place the hood in the surround as shown in Figure 48 and fasten
with the ve screws and nuts supplied.
Fitting of Surround
Place the surround as shown in Figure 48 on the at front heater
as shown in Figure 49 and fasten to the heater with the four screws
provided at points A, B, C and D.
Note: See page 47 “General Glass Information” for removing and
replacing glass assembly and lower louver.
Figure 49
Figure 48
FGKSURROUNDINSTALLATIONINSTRUCTIONS
Note: If applicable, remove plastic covering from surround.
See Page 16, Figure 14 for rough framing dimensions.
1. Pull Mantis unit out from the wall.
2. Remove three (3) screws from rebox. See Figure 50.
3. Place shield on top of rebox and secure with three (3) screws
removed in step 1.
4. Assemble the surround with eight (8) #10 x 1/2 screws (four
on each side) as shown in Figure 51.
5. Remove two (2) screws from Mantis Control Panel Circuit
Plate. See Figure 52.
6. Use needle nose pliers to remove the six (6) red capped plugs
one at a time from the connectors on the circuit board plate
rocker switch. See Figure 53. After each cable is removed
from the circuit board plate, attach the matching colored cable on the new wiring harnesses included with the surround
kit. See Figure 54.
7. Using the two (2) screws removed in Step 5, reattach the
Mantis Control Panel Circuit Plate. See Figure 52.
8. Install bushing on left or right side of surround. See Figure
51.
9. Move the surround close to the rebox and thread cable harnesses through the bushing on the surround towards the rocker switch. See Figure 55.
10. Attach caps to rocker switch. See Rocker Switch Wiring Dia-
gram. See Figure 56. Tuck wires into the rebox.
11. Install rocker switch on same side of surround as bushing.
The switch will be easily accessible from the outside of the
surround. See Figure 51.
12. Attach surround to at front replace by lining up the hooks
on the surround with the cutouts on the at front replace
and then pushing down on surround until it locks in place.
See Figure 50. If cutouts are not in the replace top, use the
template included with the kit to create the cutouts.
13. Replace unit into wall.
Figure 50
27020-3-0410Page 36
Page 37
FGKSURROUNDINSTALLATIONINSTRUCTIONS
RED
RED
GREEN
BLUE
YELLOW
BROWN
PURPLE
GREEN
BLUE
PURPLE
BROWN
YELLOW
RED
GREEN
BLUE
PURPLE
BROWN
YELLOW
NEW WIRING HARNESS
FROM SURROUND KIT
HARNESSES COMING
FROM MANTIS
BUSHING
ROCKER SWITCH
LINE UP SIDE HOLE
WITH BOTTOM SURROUND
ON BOTH SIDES
RED
RED
GREEN
BLUE
YELLOW
BROWN
PURPLE
GREEN
BLUE
PURPLE
BROWN
YELLOW
ROCKER SWITCH
IN SURROUND BOTTOM
Figure 51
Figure 52
Figure 54
Figure 55
27020-3-0410Page 37
Figure 53
Figure56
Page 38
OPERATINGINSTRUCTIONSCHECKLIST
BEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING
CHECKLIST
1. Read and understand these instructions before installing or
operating this appliance.
2. This appliance is should be installed and repaired by a
fully qualied service person who must be familiar with the
installation of the Mantis Power-Vent High-Efciency
Fireplace.
3. Installers who are not familiar with the installation of this
appliance should contact Empire Comfort Systems, Inc.
prior to installing the appliance to avoid creating hazardous
operating conditions.
4. Check and inspect the appliance for gas leaks. In the event
of gas leaks, cut off the gas supply to the heater immediately
and call your gas supplier or installer.
5. Check and verify that all ue venting combustion air intakes
and ue outlets are unobstructed.
6. Refer to Pages 20 to 22 for Single Flue pipe and Page 31 for
Co-axial Flue installations. Check that correct ue pipe and
cap has been tted in line with the manufacturer’s specica-
tions as illustrated in this manual Pages 11 to 30.
7. Do not use alternative Flue or cap on installation other
than that specied in this manual - otherwise heater will
malfunction and cause hazardous operating conditions and
will void the manufacturer’s warranty.
8. Check and verify that ue pipe connection to the appliance
when using single 1 1/2” ue pipe installation is correctly
installed and secured in line with instruction in this manual,
Pages 20 to 22.
9. Prior to operating the appliance, check for dust or debris on
the burners. Refer to Page 46, Figure 69 and Page 48, Figure
71.
10. Check and verify that logs are place correctly as per
instructions on Pages 18 to 20 of this manual. If logs are incorrectly positioned, it can create a hazardous situation, and
in most instances, the heater will not operate correctly.
11. Do not light heater without logs installed, as heater will not
operate properly.
12. Check and verify prior to starting the appliance, that all panels
are secured in place and that the main door has been locked in
position.
13. After verifying and checking all the above points, proceed to
lighting instructions. Refer to Pages 39 to 40.
27020-3-0410Page 38
Page 39
LIGHTING INSTRUCTIONS
A
B
C D
E
F
G
H
FRONT
BURNER
SWITCH
REAR
BURNER
SWITCH
THERMOSTAT
DISPLAY MODE
BUTTON
1. Main Electrical power supply must always be switched on to
the unit with the two burner switches in the off position (up)
before lighting the heater.
2. Turn on main gas supply.
3. Verify that main electrical supply is switched on by
checking the 115V AC power status display (Figure 57)
indicator is on.
4. Burner selection: select low burn (front burner), medium
burn (rear burner), or high burn (both burners). Low burn
switch (Figure 59) controls the front burner only. Medium
burn switch (Figure 58) controls the rear burner only. When
both switches are down, they will activate both the low and
medium burners, which is the high setting.
5. Heater operating LED sequence (Front Display Panel).
Before starting ensure that the power L.E.D (Figure 60A)
is on and burner switches are off. Switch on the heater by
engaging the low and medium burner switch, this will activate the pressure switch and the exhaust fan L.E.D
(Figure 60E) will be on. Also the two burner L.E.D’s
(Figure 60C and 60D) will start ashing for 35 seconds
L.E.D’s will remain on. If you can’t see ame on the rear
burner, but the burner L.E.D is on, then there will be ame
there which will become more visible as the heater warms up.
Once the heater warms up the low speed L.E.D (Figure 60F)
will light and the convection fan will blow warm air from
the heater. As the heater becomes warmer, the medium L.E.D
(Figure 60G) will come on. When the heater has reached its
highest operating temperature, all three L.E.D’s will light up
and the convection fan will now be running at its high speed.
Refer to Page 41 - Fan Operation. When the heater has been
running for some time, the water pump L.E.D (Figure 60B) may
come on to signal that the pump has been activated. Refer to
Page 41 - Automatic Humidier Operation.
Note: Three heat settings are available for operating your Mantis
b. Medium setting (rear burner only) - engage medium
burner switch only (Figure 59)
c. High setting (front and rear burners).
prior to ignition. Once both burners have ignited, the burner
Caution: When switching from the front burner to the rear burner, be sure to activate the rear burner rst, then turn off the front
burner. When switching from rear burner to the front burner, be sure to activate the front burner rst. Simple rule - always
activate the desired burner rst, then switch the other burner off. If it is switched the wrong way, the burner(s) will go out
and the heater may need to be reset. Refer to Page 50 - Resetting the Heater.
Figure 57
Figure 59
Figure 58
27020-3-0410Page 39
Figure60
Page 40
LIGHTING INSTRUCTIONS
OFF
ON
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS
OF LIFE.
A. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the oor because some gas
is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you can not reach your gas supplier, call the re
department.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat, if used, to the lowest setting.
3. Turn off all electric power to the appliance. Turn off elec-
trical control switches to “O.”
4. This appliance is equipped with an ignition device that au-
tomatically lights the burner. Do not try to light the burner
by hand.
5. Remove the front access panel below the glass door by
pulling both sides forward simultaneously.
6. Turn gas line valve to “ON.”
7. Wait ve (5) minutes to clear out any gas. Then smell for
gas, including near the oor. If you smell gas, STOP! Fol-
B. Use on the wall switch or remote control switch to turn the
gas control on/off. Any attempted repairs or adjustments
should be performed by a qualied service technician.
Applying force or attempted repair may result in a re or
explosion.
C. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
low “A” in the safety information above. If you do not
smell gas, go to the next step.
8. Replace the front access panel, press both sides of the panel
until both lock position.
9. Turn on electric power to the appliance. Turn on electric
control switches to “I.”
10. Set thermostat to desired setting (if available).
11. If the appliance will not operate, follow the instructions
“TO TURN OFF GAS TO APPLIANCE,” and call your
service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. STOP! Read the safety information above.
2. Set the thermostat, if used, to the lowest setting.
3. Turn off electric power to the appliance.
4. Remove front access panel.
5. Turn gas line valve to “OFF.”
6. Replace front access panel.
27020-3-0410Page 40
Page 41
FAN OPERATION
The 3-speed main convection fan will automatically start approximately 3 to 5 minutes after the heater has warmed up.
Note: The 3-speed main convection fan is automatically controlled by heat build-up in the rebox and will operate on three preset
speeds. Depending on the temperature, the L.E.D lights (Page 39, Figure 60) for the fan will light up. The bottom L.E.D light (Figure
60F) is low speed setting, and middle L.E.D lights (Figure 60G) is the medium speed setting, the bottom, middle and top L.E.D lights
(Figure 60H) is the high-speed setting.
Note: The fan will operate totally independent of burner setting - it is controlled by temperature only.
HEATER SHUT DOWN INSTRUCTIONS
Turn medium burner switch (Figure 58) and low burner switch (Figure 59) to the “OFF” position.
Note:Do not cut main electrical supply to the heater after the heater has been switched off to stop main fan operating. Main fan will
stop operating automatically after the heater has cooled down sufciently.
AUTOMATIC HUMIDIFIER OPERATION
Figure61
Most gas heaters dry out the air in the room. The Mantis has
ingeniously solved this problem with an Automatic Humidier.
Gas contains moisture which is normally expelled out the ue or
chimney after combustion. But the Mantis is so efcient by taking
92% of the heat out of the burnt gases that the moisture drops out
and condenses in the back of the heater. This water is collected
in a tank which is then pumped up to a stainless steel condensate
tray, where it evaporates in the stream of hot air which is blowing
into your home. Air humidity is automatically restored!
27020-3-0410Page 41
1. The amount of condensate build up in the water sump is de-
pendent on outside temperature, length and height of the ue
pipe. The automatic humidier can operate from approxi-
mately 10 minute to 6 hour intervals, depending on ambient
temperature, style and type of ue. Long single vertical ues
can cause the humidier to come on more often depending on
heater settings.
2. When the automatic humidier is engaged and is transferring
the condensate into the holding tank, a hissing sound may be
noticeable. This occurs when the condensate enters the holding tank and is quite normal. The duration of the sound may
vary from 3 to 30 seconds until the holding tank has been
lled with the condensate.
3. When the automatic humidier pump comes on to pump con-
densate into the stainless steal tray (located on the top of the
heater), the L.E.D. light (Page 39, Figure 60B) on the front
panel will light up and ash while the condensate pump is
operating, and then extinguish after the pump has stopped
operating. This means water has been pumped into the tank,
See your Mantis dealer for correct controller type.
INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installation Instructions for FRBTP, FRBTC, and TRW
Remote Controls FRBTP, FRBTC and TRW are all battery operated devices. Begin installation by unplugging the unit and removing
the front louver panel.
Remove wire nut from black and white wire from junction box.
Black or white wire can be inserted in either remote control receiver connection hole or connected to T24V thermostat screws. There is
no polarity at this connection.
Replace front louver panel and plug unit into outlet. Turn both burner switches to the ON position. Burner switches must remain in the
ON position for remote to function. Set remote from the instructions provided with the remote control. Set T24V thermostat to desired
temperature.
Note: When the heater will not be used for long periods, the burner switches should be in the OFF position, and the heater should be
turned off at the power point.
Installation Instruction for TMV2 - Two Stage Thermostat Model:
Begin installation by unplugging the unit and removing the front louver panel.
Determine mounting location of thermostat. Using standard 18 AWG wire, run four (4) strands of wire into rear of Mantis
(See Figure 62) to junction block. Cut wire to correct length.
Figure62
Figure63
27020-3-0410Page 42
Page 43
OPTIONAL CONTROLLERS
BLACK
WHITE
RED
TO
TRANSFORMER
BLUE
TO “T2” (REAR BURNER)
TO “T1” (FRONT BURNER)
REMOTE WIRE HORNESS
(TOBE REMOVED)
WHITE,
WHITE/
BLACK
W1 RW2C
BLUE
TO “T1”
TO “T2”
C
TO
THERMOSTAT
W2
W1
R
JUNCTION
BLOCK
FRONT
BURNER
SWITCH
REAR
BURNER
SWITCH
THERMOSTAT
DISPLAY MODE
BUTTON
R: 24 Volt Hot
W1: Heat Relay Stage 1 (Front burner)
W2: Heat Relay Stage 2 (Rear burner)
C: 24 Volt Common
Figure64
Replace front louver panel and plug unit into outlet. Turn both burner switches to ON position. Burner switches must remain in the ON
position for thermostat to function. Set thermostat using the instructions provided with the thermostat.
Note: When the heater or the Remote Control will not be used for long periods the burner switches should be in the OFF position,
also in summer the heater should be turned off at the power point.
Economy Display Mode
Economy Display Mode (Red Button Operation): The red button above the two burner switches (Figure 65) is called the economy
display mode and will only function when a Controller has been installed in the heater. The most common way to use this button is to
set the controller to Thermo mode with a desired temperature set for the heater to turn on and off, which is dependant on the ambient
temperature, location and the area the appliance is positioned. When using a controller both burner switches need to be in the ON
position. When the red button is pressed with both burner switches on, the front burner only will ignite or if already alight, it will now
remain on regardless of what function or temperature is set on the Remote Control. The red button acts as an override switch for the
front burner only.
In this situation only the back burner will turn on and off according to the setting on the Remote Control. By running the heater this way
you will use less gas and still have the aesthetic effect of the front burner. However, if the appliance is in a small area, this setting may
get to warm for you. To change the setting, press the red button so that it is not illuminated and the heater will revert back to its normal
operation.
Note: When the heater or the Remote Control will not be used for long periods the burner switches should be in the OFF position,
also in summer the heater should be turned off at the power point.
27020-3-0410Page 43
Figure65
Page 44
WIRING
(1)(2) BLACK
BLACK (3)(4) RED
YELLOW (5)(6) RED
BLUE (7)(8) BROWN
GREY (9)(10) RED
RED (11)(12) BLACK
BLACK (13)(14) RED
RED (15)(16) FRONT H.S.I.
FRONT H.S.I. (17)(18) REAR H.S.I.
REAR H.S.I. (19)(20) BROWN
WHITE (3-5-7)(1) BLUE
BLACK (8)(2) BLACK
(15) ORANGE
(13) RED
(11) BLACK
(9) BROWN
(7) PURPLE
(5) BLUE
(3) WHITE
(1) YELLOW
GREEN/YELLOW (16)
BLACK (14)
BLACK (12)
GREEN (10)
RED (8)
RED (6)
BLACK (4)
RED (2)
(5) YELLOW
(3) BLACK
(1) GREY
ORANGE (6)
WHITE (4)
RED (2)
WATER LEVEL
SWITCH
TRANSFORMER
14 WAY RIBBON TO
FRONT PANEL DISPLAY
FRONT BURNER
SWITCH
REAR BURNER
SWITCH
THERMISTOR
P1 TO
DISPLAY
P1 TO
DISPLAY
AIR PRESSURE
SWITCH
PIN 5
(NC)
(NO)
(COM)
TRANSFORMER
120V BLACK
PINS4OR 6
CONV. FAN
PIN 13
GAS VALVE
80 C
VALVE /
INDP
FLUE FAN
PIN 3
PIN 6
PIN 4
120V WHITE
HSI
PIN 18
PIN 16
PIN 20
PIN 5
CONDENSATE
PUMP
WIRING DIAGRAM
WHITE
BLACK
ORANGE
ORANGE
BLACKBLACK
ORANGE
YELLOW
TRANSFORMER
TO JUNCTION BLOCK
YELLOW
BLUE
BLUE
BROWN
BROWN
F
R
GREY
4µF
3µF
14 WAY RIBBON TO
CONTROL MODULE
P1
T1
T2
P2
OPTIONAL
CONTROL
WIRING
RECEIVER
OR
T-STAT
BLACK
WHITE
PURPLE
YELLOW
WHITE
WHITE
BLACK
RED
R. BRN. THERM (4)
L. BRN. THERM (3)
BLACK
BLUE
WHITE
RED
BLUE
JUNCTION
BLOCK
TO
TRANSFORMER
BLUE
INDICATOR
SWITCH
BLACK
WHITE
WHITE
+ -
W1
W2
CR
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70 or Canadian
Electrical Code, CSA C22.1, if an external electrical source is
utilized. This appliance is equipped with a three-prong
and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the grounding
prong from this plug. For an ungrounded receptacle, an adapter,
which has two prongs and a wire for grounding, can be purchased,
plugged into the ungrounded receptacle and its wire connected
to the receptacle mounting screw. With this wire completing the
ground, the appliance cord plug can be plugged into the adapter
and be electrically grounded.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
WARNING:Potentialriskofre,electricshock,
and personal injury. Take precautions to reduce
such risks.
Note: For testing ame sensor circuit use a micro-amp meter
in series with sensor. Minimum current should be 1 micro-amp
during operation. Be careful as ame sensor is in the 115VAC
circuit. If current is below 1 micro-amp, remove sensor, clean
with light sandpaper and retest.
Figure66
Figure67
27020-3-0410Page 44
Page 45
GENERAL INFORMATION
Over Temperature Cut Out
The Mantis Power-Vent High-Efciency Fireplace is protected
against overheating with a high temperature 80°C (176°F) cut off
switch to protect the heat exchanger, plastic sump and ue fan.
The high temperature cut off switch will automatically switch off
the gas supply to the heater, if the temperature in the room where
the heater is located reaches approximately 28°C (82.4°F). The
heater will go into lock out mode. An allowance of 15 minutes
minimum must be made to allow for the main fan to cool down
the heater prior to restarting the appliance.
Note: In most instances, overheating of the heater is a direct
result of too much lint and dust having accumulated in the main
convection fan. This makes the fan unable to supply sufcient
air to cool down the heat exchanger. It is recommended that you
inspect your main convection fan prior to the start of the heating
season and if necessary have it serviced by a qualied service
technician (refer to Pages 45 and 49 - Maintenance).
Paint Curing - First Firing
The rst re in your heater is part of the paint curing process.
Your Mantis Power-Vent High-Efciency Fireplace has been
painted with the highest quality heat resistant silicon paint
available in the world.
To ensure that the paint is properly cured, light the unit and leave
it burning on high burn for approximately 1 hour.
1. During initial ring of this unit, its paint will bake out, and
smoke will occur. To prevent triggering of smoke alarms,
ventilate the room in which the unit is installed. During initial
ring of logs, you will detect an odor as the logs are cured.
Also, during the curing process the logs will burn with a
yellow ame.
2. Don’t touch the surface of the heater. It will be soft during
this paint-curing phase. Once cured it will not be soft again.
3. The paint nish of the heater should not be cleaned with any
caustic or abrasive cleaning solutions.
4. Any damage to painted surface should be repaired with
special touch paint available from your Mantis Dealer.
BAY WINDOW MAINTENANCE
Note: Your appliance should be inspected, serviced and checked
annually by a qualied service person to ensure that
your appliance is operating safe and efciently. Should
you detect any abnormality in the operation of your
appliance call a qualied service person who has
been trained and approved to inspect and service the
appliance. This may be your installer or dealer (routine
service is not covered under warranty).
27020-3-0410Page 45
Page 46
BAY WINDOW MAINTENANCE
LOG SUPPORT PLATE
BURNER PLATE
REAR BURNER
FRONT BURNER
IGNITOR ASSEMBLY
FLAME SENSOR
Figure68
Front door removal drawing
Glass Cleaning
It will be necessary to clean the glass periodically. During
start-up, condensation, which is normal, forms on the inside of
the glass and causes lint, dust and other airborne particles to cling
to the glass surface. Also, initial paint curing may deposit a slight
lm on the glass. It is therefore recommended that the glass be
cleaned two or three times with a non-abrasive household cleaner
and warm water (we recommend gas replace glass cleaner) after
the initial burn. We do not recommend using packaged spray type
household glass cleaner. After that, the glass should be cleaned
two or three times during each heating season depending on the
circumstances present.
General Glass Information
Only glass approved for use in Empire Comfort Systems, Inc.
replace may be used for replacement. The glass replacement
must be done by a licensed or qualied service person.
WARNING:
1. The use of substitute glass will void all product warranties.
2. Care must be taken to avoid breakage of the glass.
3. Under no circumstances should this appliance be
operated without the glass front or with a broken glass front.
Replacement of the glass (with gasket) as supplied by the
manufacturer must be done by a qualied service person.
4. Do not abuse the glass by striking or hitting the glass.
WARNING: Do not use abrasive cleaners on glass. Do not
attempt to clean glass when glass is hot.
Glass Assembly Replacement
1. Remove cabinet top.
2. Pivot left and right front panels open.
3. Release two door latches on left and right of rebox.
4. Grasp glass frame and carefully pull toward you.
5. Place glass frame assembly on non-abrasive surface. The
exterior of the glass frame assembly should be facing the
nonabrasive surface.
6. Insert a putty knife between glass and bottom corners on
frame. Carefully separate glass from frame.
7. Use putty knife to remove silicone and gasket material from
frame. Surface of frame must be clean and dry.
8. At each corner of frame apply two (2) three inch beads of
high temperate (orange) silicone.
9. With thin gasket on glass facing silicone on frame, insert
glass into frame. Carefully press the glass onto frame in order
to have contact between glass and silicone.
10. Allow silicone to set-up for an adequate time.
11. Gently place glass frame back into rebox.
12. Close the 2 door latches on left and right of rebox.
13. Pivot left and right front panels closed.
14. Replace cabinet top.
Figure69
Main Burner Drawing
Cleaning Main Burner
Remove main burner and apply air pressure inside the throat and
ports of the main burner.
RemovingHSIFlameSensor,BlowerandOrice
1. Remove front door assembly. See Figure 68.
2. Remove logs from rebox.
3. Remove installation bracket and gasket from underside of
rebox (1 screw).
4. Disconnect ame sensor and HSI connector from wiring
harness.
5. Remove log support from inside rebox (13 screws).
6. Remove HSI from log support (13 screws).
7. Remove ame sensor from log support (1 screw).
8. Remove burners from rebox (1 screw).
9. Once burners are removed, orices are exposed.
27020-3-0410Page 46
Page 47
FLAT FRONT MAINTENANCE
Note: Your appliance should be inspected, serviced and
checked annually by a qualied service person to
ensure that your appliance is operating safe and
efciently. Should you detect any abnormality in the
operation of your appliance call a qualied service
person who has been trained and approved to inspect
and service the appliance. This may be your installer or
dealer (routine service is not covered under warranty).
Glass Cleaning
It will be necessary to clean the glass periodically. During
start-up, condensation, which is normal, forms on the inside of
the glass and causes lint, dust and other airborne particles to cling
to the glass surface. Also, initial paint curing may deposit a slight
lm on the glass. It is therefore recommended that the glass be
cleaned two or three times with a non-abrasive household cleaner
and warm water (we recommend gas replace glass cleaner) after
the initial burn. We do not recommend using packaged spray type
household glass cleaner. After that, the glass should be cleaned
two or three times during each heating season depending on the
circumstances present.
General Glass Information
Only glass approved for use in Empire Comfort Systems, Inc.
replace may be used for replacement. The glass replacement
must be done by a licensed or qualied service person.
WARNING:
1. The use of substitute glass will void all product warranties.
2. Care must be taken to avoid breakage of the glass.
3. Under no circumstances should this appliance be
operated without the glass front or with a broken glass front.
Replacement of the glass (with gasket) as supplied by the
manufacturer must be done by a qualied service person.
4. Do not abuse the glass by striking or hitting the glass.
Figure 70
Front door removal drawing
WARNING: Do not use abrasive cleaners on glass. Do not
attempt to clean glass when glass is hot.
Glass Assembly Replacement
Removal
1. Remove lower louver panel by lifting up and pulling out.
2. Release two (2) hinge clips on underside of rebox.
3. Angle bottom of glass assembly approximately 60 degrees
out from rebox. Gently pull glass assembly away from
rebox.
Replacement
4. Insert the tabs on top of new glass assembly into the slots on
top of the rebox and gently lower the glass assembly down.
5. Attach and tighten the two (2) hinge clips on underside of
rebox.
6. Replace lower louver panel.
27020-3-0410Page 47
Page 48
FLAT FRONT MAINTENANCE
REAR LOG SUPPORT
FRONT LOG SUPPORT
FIREBOX BOTTOM
REAR HOT SURFACE IGNITOR
REAR FLAME SENSOR
REAR BURNER
FRONT BURNER
FRONT FLAME SENSOR
FRONT HOT SURFACE IGNITOR
Figure 71
Removal and replacement of Front Hot Surface Ignitor
(HSI)
1. Unplug power cord from electricity.
2. Remove lower louver door.
3. Remove glass assembly. See Page 47.
4. Carefully remove logs from unit.
5. Remove one (1) screw with 5/16 socket from bracket
securing HSI to rebox bottom and set aside.
6. Disconnect two (2) white caps connecting HSI to wire
harness.
7. Cut wires at HSI and pull through the rebox bottom and
discard.
8. Remove (1) screw securing bracket to HSI with a 1/4” socket.
Set aside screw and bracket. Discard old HSI.
9. Place bracket removed in Step 7 around new HSI and secure
with screw removed in Step 7.
10. Secure bracket to rebox bottom with screw removed in Step
3.
11. Carefully feed HSI wires through hole in bottom of rebox
from the topside to underneath.
12. Place caps included with kit on each HSI wire.
13. Connect caps to plugs disconnected in Step 5.
14. Use clear high temp silicone (not supplied) to fully plug wire
hole in rebox bottom. Allow appropriate time to dry.
15. Replace logs into unit. See Pages 18 to 20.
16. Replace glass assembly. See Page 47.
17. Replace lower louver door.
18. Reconnect power cord to electricity.
Removal and replacement of Rear Hot Surface Ignitor (HSI)
1. Unplug power cord from electricity.
2. Remove lower louver door.
3. Remove glass assembly. See Page 47.
4. Carefully remove logs from unit.
5. Carefully remove front log support by lifting out. Use caution
to not damage front HSI or to bend or break support.
6. Remove one (1) screw with 5/16 socket from bracket
securing HSI to rear log support and set aside.
7. Disconnect two (2) white caps connecting HSI to wire
harness.
8. Cut wires at HSI and pull through the rear log support and
discard.
9. Remove (1) screw securing bracket to HSI with a 1/4” socket.
Set aside screw and bracket. Discard old HSI.
10. Place bracket removed in Step 8 around new HSI and secure
with screw removed in Step 8.
11. Secure bracket to rebox bottom with screw removed in
Step 5.
12. Thread HSI wires through hole in rear log support down
and then through the hole in rebox bottom and behind rear
burner tube.
13. Place caps included with kit on each HSI wire.
14. Connect caps to plugs disconnect in Step 6.
15. Use clear high temperature silicone (not supplied) to fully
plug wire hole in rear log support. Allow appropriate time to
dry.
16. Replace front log support.
17. Replace logs. See Pages 18 to 20.
18. Replace glass assembly. See Page 47.
19. Replace lower louver door.
20. Reconnect power cord to electricity.
27020-3-0410Page 48
Page 49
FLAT FRONT MAINTENANCE
Removal and Replacement of Front or Rear Flame Sensors
1. Unplug power cord from electricity.
2. Remove lower louver door.
3. Remove glass assembly. See Page 47.
4. Carefully remove logs from unit.
5. Unplug ame sensor from wire harness.
6. Remove screw with 1/4” socket securing ame sensor to
rebox bottom (front ame sensor or rear log support (rear
ame sensor).
7. Gently pull ame sensor and wires out of unit and discard.
8. Carefully thread ame sensor wires through rebox bottom
(front ame sensor) or rear log support (rear ame sensor).
9. Reconnect ame sensor wire to wire harness.
10. Use clear high temperature silicone (not supplied) to fully
plug wire hole in rebox bottom. Allow appropriate time to
dry.
11. Replace logs. See Pages 18 to 20.
12. Replace glass assembly. See Page 47.
13. Replace lower louver door.
14. Reconnect power cord to unit.
Remove and Replace or Clean the Circulating Air Blower
1. Unplug power cord from unit.
2. Remove lower louver door.
3. Remove lower louver door.
4 Remove two (2) 5/16” screws securing control assembly to
Mantis bottom and set control assembly and screws aside.
Caution: Do not disconnect wires from unit.
5. Remove one (1) 5/16” screw securing junction block to
blower. Set screw and junction block aside. Caution: Do not
disconnect wires from unit.
6. Remove one (1) 5/16” screw securing pressure switch to
blower housing and set pressure switch and screw aside.
Caution: Do not disconnect wires or hoses from unit.
7. Remove two (2) 5/16” screws securing blower housing to
Mantis bottom. Set screws and ground wire aside.
8. Disconnect 3-prong cap and plug from wire harness to
remove blower from replace. Blower can be cleaned with
compressed air or replaced at this point.
9. Secure blower housing and ground wire to Mantis bottom
with two (2) 5/16” screws removed in Step 6.
10. Secure pressure switch to blower housing with one (1) 5/16”
screw removed in Step 5.
11. Secure junction block to blower with one (1) 5/16” screw
removed in Step 4.
12. Secure control assembly to Mantis bottom with two (2) 5/16”
screws removed in Step 3.
13. Close lower louver door.
14. Replace lower louver door.
15. Reconnect power cord to electricity.
Cleaning Burners
Remove main burner and apply air pressure inside the throat and
ports of the main burner.
Removing and Replacing Front Burner
1. Unplug power cord from electricity.
2. Remove lower louver door.
3. Remove glass assembly. See Page 47.
4. Carefully remove logs from unit.
5. Carefully remove front log support by lifting out. Use caution
to not damage front HSI or to bend or break support.
6. Remove two (2) screws securing front burner to rebox
bottom with Phillips screwdriver and set aside.
7. Slide burner to the right and lift out.
8. Burner can be cleaned at this point
9. Place burner onto right side of rebox bottom. Slide left and
secure in place with two (2) screws removed in step 5.
10. Replace front log support.
11. Replace logs. See Pages 18 to 20.
12. Replace glass assembly. See Page 47.
13. Replace lower louver door.
14. Reconnect power cord to electricity.
Removing and Replacing Rear Burner
1. Unplug power cord from electricity.
2. Remove lower louver door.
3. Remove glass assembly. See Page 47.
4. Carefully remove logs from unit.
5. Carefully remove front log support by lifting out. Use caution
to not damage front HSI or to bend or break support.
6. Remove two (2) 5/16” screws securing rear log support to
rebox side (one each side). Lift up rear log support, but do
not remove from rebox.
7. Remove two (2) screws securing burner to rebox bottom
with Phillips screwdriver.
8. Slide burner to right and lift out.
9. Burner can be cleaned at this point.
10. Place burner on right side and slide left into rebox and
secure with screws removed in step 6.
11. Lower rear log support and secure to rebox sides with
screws removed in Step 5.
12. Replace front log support.
13. Replace logs. See Pages 18 to 20.
14. Replace glass assembly. See Page 47.
15. Replace lower louver door.
16. Reconnect power cord to electricity.
27020-3-0410Page 49
Page 50
UNIT OPERATING FAULTS
SERVICE AND INSTALLATION OF THE APPLIANCE
SHOULD BE CARRIED OUT BY AUTHORIZED PERSONNEL ONLY.
THE MAJOR CAUSE OF OPERATING PROBLEMS
WITH GAS FIREPLACE HEATERS IS IMPROPER
GAS PRESSURE, INCORRECT LOG PLACEMENT,
IMPROPER INSTALLATION, INCORRECT FLUE
INSTALLATION, INCORRECT SWITCHING OF
BURNERS, DIPS/SPIKES IN THE INCOMING POWER
OR REVERSE POLARITIES.
RESETTING THE HEATER
There are a number of reasons why sometimes the heater will
switch itself off and is the correct thing for the heater to do in
certain situations (i.e. overheating, power failure or dips, windy
conditions, pump failure, partial or full blockage of ue pipe or no
gas. All of these operations are monitored by the electronic control box inside the heater, which is heat sensitive, pressure switch
sensitive, ame sensitive and water sensitive. If one of these items
is not correct, the heater will shut itself down.
To reset, turn both burner switches to the OFF position, ensure the
red button above the two burner switches is not illuminated (if a
Remote Control is tted, have it in the off mode). Then turn the
power off at the power point for approximately 10 seconds. Then
turn the power point back on and the power L.E.D. should be illu-
This situations can cause such problems as changes in ame color
or conguration, intermittent operations, changes in heat output,
carbon build up or sooting, bad odors, rattles or other sounds,
start up failures and burner(s) switching themselves off. These
are nearly always the result of improper installation or incorrect
operation and it may take sometime for these problems to show
themselves. Before calling out a technician you must be able to
repeat the fault, try resetting the heater. Read below.
Note: Incorrect installation of the unit, logs, ue pipe, gas
pressure or operation, which cause the above mentioned faults, are
not covered under warranty and a service call fee will be charged
to correct such problems.
minated. If you have a Remote burner switch and the rear burner
L.E.D. should start ashing, with the ue fan L.E.D. remaining
steady. Wait approximately 60 seconds for the rear burner to ig-
nite. You can tell when it has lit, even if you can’t see any ames,
by looking at the rear burner L.E.D. which should remain steady.
Repeat the same process with the front burner. Turn on the front
burner switch and wait approximately 60 seconds and the front
burner L.E.D. will remain steady.
In approximately 5 minutes the convection fan should start and
the heater has been successfully reset.
Note: if the heater is still warm when reset the convection fan
may already be running when the unit is powered up.
If for any reason a log should need replacement, you must use the
proper replacement log. Consult your Mantis dealer for correct
replacement logs.
LOG PLACEMENT
Replacement logs must be installed and positioned as outlined on
Pages 18 to 20 under Log Installation.
Note:Improper positioning of logs can create carbon build up
and will alter the unit’s performance and operation.
27020-3-0410Page 50
Page 51
MAIN CONVECTION FAN
COMBUSTION AIR
INTAKE SLOT
COMBUSTION AIR
DEFLECTOR
SURROUND TOP
SURROUND SIDE
4 SCREWS
The main convection fan in the heater should be checked,
serviced and cleaned annually by a qualied service person to
ensure that your appliance is operating efciently.
HEAT EXCHANGER
The heat exchanger of the unit is located at the rear of the heater.
The heat exchanger should be inspected annually by a qualied
service person for lint and dust build up. Excessive dust and lint
build-up in the heat exchanger can alter the unit’s performance
and operation.
BAY WINDOW SURROUND INSTALLATION INSTRUCTIONS
Note: If the main convection fan becomes clogged with lint and
dust an over-temperature situation will occur through the
heater exchange system and the over-temperature safety
switch will stop the heater from operating.
Note: This appliance (Insert and Freestanding Models) needs
to be installed in such a way that the heater (especially
with models built into a replace) can be removed at all
times to service the heat exchanger and ue fan, which
are located at the rear section of the heater.
Under no circumstances should the appliance be
installed under conditions that would not allow for easy
removal of the appliance to carry out routine inspection and
service work on the appliance.
DISCONNECT MAIN POWER PRIOR TO STARTING
ANY WORK ON THE APPLIANCE.
1. Remove Fireplace Insert Surround assembly from carton,
handle insert surround with care to avoid paint damage.
2. Assembly Fireplace Insert Surround as per diagram with four
(4) 10 x 1/2” screws supplied.
Figure 72
Part NumberDescriptionQuantity Supplied
22754Top, Surround Assembly1
21859Side, Surround 6”2
24839Top, Surround Assembly1
24835Side, Surround 6”2
Replacement 10 x 1/2” screws can be purchased from a local hardware store.
PARTS LIST
PVE1-1
PVE2-1
3. Install surround assembly around replace.
4. Install either slim or short top. Note: Top will hold surround
in place.
Figure 73
27020-3-0410Page 51
Page 52
PEDESTAL INSTALLATION INSTRUCTIONS - BAY WINDOW ONLY
SCREW
HOLE
SCREW
HOLE
LOCATOR
SLOT
LOCATOR
SLOT
Optional Pedestal Assembly Installation
1. Remove pedestal assembly from carton. Handle pedestal
with care to avoid paint damage.
2. Place pedestal assembly into position where heater is to be
located.
3. Lift and place main body of heater on top of pedestal
assembly and align main body of heater with locating tabs
provided on pedestal assembly (refer to diagram).
NOTE: To avoid accidents and damage to main heater body and
paint-work, it is recommended that main body of heater should be located on top of pedestal assembly by 2
people.
4. Secure pedestal assembly to main body of heater with three
(3) 1/2”- 10 x 24 screws supplied (refer to diagram).
Note: Use the three (3) 1/2”- 10 x 24 screws and washers provided to secure pedestal assembly to base of heater.
Figure 74
27020-3-0410Page 52
Page 53
MASTER PARTS DISTRIBUTOR LIST
To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide
warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the
unit.
To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below. This list grows
from time to time. For the current list, please click on the Master Parts button at www.empirecomfort.com.
Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts
for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc.
Parts can be ordered through your Service Person, Dealer, or a Master Parts Distributor. See this page for the Master Parts Distributors list. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the
service person/dealer.
Warranty Parts
Warranty parts will need a proof of purchase and can be ordered by your Service Person or Dealer. Proof of purchase is required for
warranty parts.
All parts listed in the Parts List have a Part Number. When ordering parts, rst obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate
illustration and list. Be sure to give all this information . . .
Appliance Number Part Description
Appliance Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, res and all causes beyond our control.
27020-3-0410Page 53
Page 54
BAY WINDOW - PARTS LIST
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
INDEX
NO.
126751REAR PANEL
221654BRACKET, PIPE ASSEMBLY
324831REAR HEAT SHIELD ASSEMBLY
4A21664
4B22933SLIM TOP ASSEMBLY
5R8854BALL STUD
622693TOP HEAT SHIELD ASSEMBLY
721637FIREBOX ASSEMBLY
826089
9R10337GASKET, END PLATE
10R9987FLEX LINE - 24”
1126087
1222863
13R10299SWITCH, BIMETALIC
14R8795GASKET, SUMP
1526090FIN TUBE ASSEMBLY
16R8811GASKET, INLET HEADER
1721650TUBING (SUMP TO PUMP)
1821652
1921627SHIELD, REAR INNER
2025227ELECTRIC PARTS PLACE
2121667LEFT SIDE DOOR ASSEMBLY
2222642TUBE, CONDENSATE
2321647
2421605COVER, INLET AIR DUCT
2522780INLET AIR DUCT ASSEMBLY
PART
NO.
DESCRIPTION
TOP COVER ASSEMBLY
(INCLUDES #5)
HEAT EXCHANGER TUBE ASSEMBLY
SUMP ASSEMBLY
(INCLUDES #12 & #14)
BLOWER ASSEMBLY (INCLUDES
#14)
TUBING (SUMP TO PRESSURE
SWITCH)
CONNECTOR TUBING ASSEMBLY
(PUMP TO CONDENSATE TUBE)
SMALL BURNER ASSEMBLY LP
(INCLUDES R10675 AND #44)
SMALL BURNER ASSEMBLY NAT
(INCLUDES #43 AND #44)
LARGE BURNER ASSEMBLY - LP
(INCLUDES #44 AND R10676)
LARGE BURNER ASSEMBLY - NAT
(INCLUDES #44 AND R10675)
BUSHING, AIR SHUTTER
(NAT ONLY)
27020-3-0410Page 54
Page 55
BAY WINDOW - PARTS LIST
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
INDEX
NO.
48R7572JAMB NUT
4927071GAS LINE - REAR
5026128GAS LINE - FRONT
51M174GASKET
5211269GAS LINE BRACKET
53R8886COMPRESSION FITTING
54R8812VALVE, NAT
54R8869VALVE, LPG
55R8898PIPE NIPPLE
56R8825SOLENOID
57R3312CONNECTOR, MALE 3/8 X 3/8
58R9487REMOTE WIRE HARNESS
59R10072SHUT-OFF VALVE
6021643FIREBOX BASE ASSEMBLY
61R10074CONTROL BOX ASSEMBLY
62R8889TRANSFORMER 12-24V
63R8804TRANSFORMER 24V
64R10591LOG SET
65R8817TERMINAL STRIP
6722778AIR CIRCULATOR ASSEMBLY
6821663DOOR ASSEMBLY, BLACK
6822758DOOR ASSEMBLY, CHROME
6822759DOOR ASSEMBLY, GOLD
6926582FRONT PANEL ASSEMBLY
70R8840
71R8809SWITCH, DOUBLE ROCKER
72R8904CIRCUIT BOARD
7325226CIRCUIT BOARD PLATE
PART
NO.
DESCRIPTION
WIRE HARNESS
(WITH RED BUTTON SWITCH)
INDEX
NO.
74R8905RIBBON CABLE
75R8872CIRCUIT BOARD WIRE HARNESS
76R10182WIRE HARNESS, 120V
77R10183WIRE HARNESS 12V
78R10190WIRE HARNESS 12V
7926075PUMP ASSEMBLY
80R10489AIR PRESSURE SWITCH
81R8881CAPACITOR 3uF
82R8880CAPACITOR 4uF
83R8911TRANSFORMER WIRE ASSEMBLY
84R10485LOG, LEFT REAR
85R8822LOG, TOP LEFT
86R10487LOG, TOP RIGHT
87R10486LOG, RIGHT
88R8820LOG, CENTER
89R8821LOG, FRONT RIGHT
90R8819LOG, FRONT LEFT
NOT
SHOWN
NOT
SHOWN
NOT
SHOWN
PART
NO.
25325CONDENSATE PUMP COVER
R10675
R10676
BUSHING, AIR SHUTTER
BUSHING, AIR SHUTTER
DESCRIPTION
27020-3-0410Page 55
Page 56
BAY WINDOW - PARTS VIEW
1
31
4A
5
6
9
7
30
28
5
21
27
24
28
19
11
12
9
34
16
14
26
25
22
17
8
3
2
13
36
18
35
23
4B
15
27020-3-0410Page 56
Page 57
BAY WINDOW - PARTS VIEW
69
67
32
61
50
47
48
53
54
53
51
60
20
56
55
48
47
80
52
65
39
40
41
42
38
45
46
89
85
86
87
88
81
84
78
77
83
76
90
44
43
49
37
82
70
71
64
79
63
62
57
59
30
10
74
75
68
29
58
72
73
27020-3-0410Page 57
Page 58
FLAT FRONT PARTS LIST
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
INDEX
NO.
125207PANEL - TOP
221595CONDENSATE TRAY
325223LOUVER - TOP
425212REAR BURNER TRAY
5R9987FLEX LINE
626081FRONT BURNER TRAY ASSEMBLY
725205PANEL - LEFT SIDE
821605INLET AIR DUCT COVER
921604INLET AIR DUCT
10R8810INLET AIR DUCT GASKET
11R8825SOLENOID
12R10072GAS SHUT OFF VALVE
13R8812VALVE - NAT
1426071GLASS ASSEMBLY
1525208BOTTOM PAN
1622778AIR CIRCULATOR ASSEMBLY
17R8817TERMINAL STRIP
18R10338PRESSURE SWITCH
1925227ELECTRICAL PARTS PLATE
20R10074CONTROL BOX
21R8889TRANSFORMER 12-24V
22R8881CAPACITOR 3uF
23R8880CAPACITOR 4uF
24R8804TRANSFORMER - 24V
25R10079CONDENSATE PUMP BOX
26R8832CONDENSATE PUMP
27R10080CONDENSATE PUMP LID
2825226CIRCUIT BOARD PLATE
29R8809DOUBLE ROCKER SWITCH
30R8876LOCK OUT SWITCH
31R8904CIRCUIT BOARD
3226083FRONT BURNER ASSEMBLY
3326082BACK BURNER ASSEMBLY
34R10082ORIFICE HOLDER
3522865
36R8807FLAME SENSOR (2 REQUIRED)
3725210AIR DUCT CHANNEL
3825214PANEL - RIGHT SIDE
3925221FIREBOX BASE
4025222DOOR BRACKET (2 REQUIRED)
41R4053DOOR CLAMP (2 REQUIRED)
4225225LATCH BRACKET (2 REQUIRED)
PART
NO.
DESCRIPTION
HOT SURFACE IGNITOR
(2 REQUIRED)
INDEX
NO.
4325215BAFFLE
4426080FIREBOX ASSEMBLY
4526087SUMP ASSEMBLY
46R8799INDUCER WHEEL
47R8798INDUCER MOTOR
4826089FLEX PIPE ASSEMBLY
4926090FIN TUBE ASSEMBLY
50R8811INLET HEADER GASKET
5125204PANEL - BACK
52R8793ORIFICE HOLDER
53R10182WIRE HARNESS - 120V
54R10190WIRE HARNESS - 12V SMALL
55R10183WIRE HARNESS - 12V LARGE
56R8814THERMISTER
57R9487REMOTE WIRE ASSEMBLY
58R8872WIRE HARNESS
59R8905RIBBON CABLE
6024831REAR HEAT SHIELD ASSEMBLY
6122642CONDENSATE PUMP TUBE
6225325CONDENSATE PUMP COVER
63R8874INDUCER, TOP SCROLL
64R10077LOG SET
64R10376REAR LOG
65R10381LEFT LOG
66R10380RIGHT LOG
67R10379MIDDLE LOG
68R10378FRONT LEFT LOG
69R10377FRONT RIGHT LOG
70R10383LEFT TOP LONG LOG
71R10382RIGHT TOP SHORT LOG
7225216BRACKET, STANDOFF (2 REQUIRED)
NOT
SHOWN
NOT
SHOWN
NOT
SHOWN
NOT
SHOWN
NOT
SHOWN
NOT
SHOWN
PART
NO.
R10093ORIFICE #47 - NAT
R10094ORIFICE #49 - NAT
R10095ORIFICE #1.2MM - LP
R10096ORIFICE #55 - LP
26117
R10299SWITCH, BIMETALIC
DESCRIPTION
AIR DUCT CHANNEL COVER PLATE NAT ONLY
USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.
27020-3-0410Page 58
Page 59
1
2
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
19
61
20
21
22
23
24
25
54
55
56
57
59
58
53
26
27
28
29
30
31
32
62
33
37
38
39
60
40
43
44
49
45
46
47
48
63
51
50
41
42
42
41
40
36
10
35
35
34
52
64
71
66
67
70
69
72
FLAT FRONT PARTS VIEW
27020-3-0410Page 59
Page 60
WARRANTY TERMS
Purchase Date:
Dealer Name/Phone:
Installer - Place Serial Number
Empire Comfort Systems Inc. warrants this hearth product to be free from defects
at the time of manufacture and for the periods specied below. Hearth products
must be installed by a qualied technician and must be maintained and operated
safely, in accordance with the instructions in the owner’s manual. This warranty
applies to the original purchaser only and is not transferable. All warranty repairs
must be accomplished by a qualied gas appliance technician.
Limited Ten-Year Heat Exchanger Warranty
Empire promises to the owner that if the heat exchanger (see parts list) fails because of defective workmanship or material within ten
years from the date of purchase, Empire will repair, or at Empire’s option, replace the defective heat exchanger.
Sticker Here and Leave this Manual
with the Consumer.
Limited Five-Year Parts Warranty
Should any part fail because of defective workmanship or material within ve years from the date of purchase, Empire will repair or
replace it, at Empire’s option.
Limited Two-Year Labor Warranty
Within two years from the date of purchase, Empire will pay reasonable labor to have that defect repaired or replaced at Empire’s option.
All labor must be accomplished by a qualied gas appliance technician.
Duties Of The Owner
The appliance must be installed by a qualied installer and operated in accordance with the written instructions furnished with the appliance.
Ready access to the appliance for service is the responsibility of the owner.
Travel, diagnostic costs and freight charges on warranted parts to and from the factory is the responsibility of the owner.
A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty period.
What Is Not Covered
This warranty does not cover damages that might result from the use, misuse, or improper installation of this appliance.
This warranty does not cover claims that do not involve defective workmanship or materials.
This warranty does not cover unauthorized service or parts replacements will not be covered.
How To Get Service
To make a claim under this warranty, please have your receipt available and contact your installing dealer. Provide the dealer with the
model number, serial number, type of gas and purchase verication. The installing dealer is responsible for providing service and will
contact the factory to initiate any warranted parts replacements. Empire will make replacement parts available at the factory. Shipping
expenses are not covered.
If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations Department, Empire
Comfort Systems Inc., P.O. Box 529, Belleville, Illinois 62222, or send an e-mail to info@empirecomfort.com with “Consumer Relations” in the subject line.
Your Rights Under State Law
This warranty gives you specic legal rights, and you may also have other rights, which vary from state to state.
Empire Comfort Systems Inc.
918 Freeburg Ave. Belleville, IL 62220
If you have a general question about our products, please e-mail us at
info@empirecomfort.com.
If you have a service or repair question, please contact your dealer.
www.empirecomfort.com
27020-3-0410Page 64